JWK10 Series DC-DC Converter 10 Watts xxx Series * Regulated Single & Dual Output * Wide 4:1 Input Range * 1" x 1" Package * 1500 VDC Isolation * Operating Temperature -40 C to +100 C * ITE Safety Approvals * Remote On/Off * Optional Heatsink * Six Sided Metal Case Dimensions: * 3 Year Warranty JWK10: 1.00 x 1.00 x 0.40" (25.4 x 25.4 x 10.16 mm) Models & Ratings Input voltage Output current Min Max Output voltage 3.3 V 5V 5.1 V 12 V 15 V 24 V 5 V 12V 15V 3.3 V 5V 5.1 V 12 V 15 V 24 V 5 V 12 V 15 V 9-36 V 18-75 V 330 300 300 125 100 62 150 62 50 330 300 300 125 100 62 150 62 50 mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA 2.20 2.00 2.00 0.83 0.66 0.41 1.00 0.41 0.33 2.20 2.00 2.00 0.83 0.66 0.41 1.00 0.41 0.33 Input current(3) No load Full load A A A A A A A A A A A A A A A A A A 30 mA 20 mA 350 mA 495 mA 505 mA 485 mA 475 mA 475 mA 495 mA 475 mA 475 mA 180 mA 250 mA 255 mA 240 mA 235 mA 240 mA 250 mA 240 mA 235 mA Maximum capacitive load(2) Efficiency Model number 560 F 560 F 560 F 150 F 150 F 68 F 220 F 100 F 100 F 560 F 560 F 560 F 150 F 150 F 68 F 220 F 100 F 100 F 86% 84% 84% 86% 87% 86% 84% 86% 87% 85% 84% 84% 86% 87% 86% 84% 86% 87% JWK1024S3V3 JWK1024S05 JWK1024S5V1 JWK1024S12 JWK1024S15 JWK1024S24 JWK1024D05 JWK1024D12 JWK1024D15 JWK1048S3V3 JWK1048S05 JWK1048S5V1 JWK1048S12 JWK1048S15 JWK1048S24 JWK1048D05 JWK1048D12 JWK1048D15 Notes 1. Input currents measured at nominal input voltage. 2. Input current is typically 10 mA at nominal input voltage when output is turned off using remote on/off. 3. Maximum capacitive load is per output. 4. Add suffix "-HK" for optional heatsink. Mechanical Details Pin Connections Optional Heatsink (-HK) 1.00 (25.4) 0.40 (10.16) 0.40 (10.16) 4 2 0.20 (5.08) 1 0.24 (6.0) 0.40 0.02 (10.16 0.5) 1.00 (25.4) 5 Bottom View 1 0.10 (2.54) 0.80 (20.3) 3 0.64 (16.3) Max. 1.22 (31.0) Max. 0.10 (2.54) Single +Vin -Vin +Vout No Pin -Vout Remote On/Off Dual +Vin -Vin +Vout Common -Vout Remote On/Off 0.77 (19.50) Max. Heat-Sink 6 0.30 (7.62) 0.69 (17.46) Max. o 0.04 (1.00) Pin 1 2 3 4 5 6 Thermal Pad Clamp Converter Notes 1. All dimensions are in inches (mm) 2. Weight: 0.03 lbs (15.0g) approx. 3. Tolerance: X.XX0.01 (X.X0.25) X.XXX0.005 (X.XX0.13) 4. Pin Tolerance: 0.002 (0.05) www.xppower.com JWK10 Series DC-DC Converter Input Characteristic Input Voltage Range Input Filter Minimum Typical Units 36 VDC 24 V nominal 18.0 75 VDC 48 V nominal Internal Pi type 50 Input Surge Undervoltage Lockout Remote On/Off Notes & Conditions Maximum 9.0 100 VDC for 1 s 24 V models 48 V models ON at >8.5 V, OFF at <9 V 24 V models ON at >18 V, OFF at <17 V 48 V models ON: Logic high (2.5-50 V) or open circuit OFF: Logic low (<1.0 V) or short pin 2 to pin 6 Output Characteristic Minimum Output Voltage 3.3 Typical Initial Set Accuracy Output Voltage Balance 1.0 Maximum Units Notes & Conditions 30 VDC See Models and Ratings table 2.0 % 2.0 % For dual output with balanced laods A No minimum load required Minimum Load At full load Line Regulation 1.0 % From minimum to maximum input at full load Load Regulation 0.5/1.0 % Single / Dual output, from 0 to full load Cross Regulation 5.0 % On dual output models when one load is varied between 25% and 100% and other is fixed at 100% 6 % deviation Transient Response 3 Ripple & Noise 100 mV pk-pk Overload Protection 150 % Short Circuit Protection Recovery within 1% in less than 600 s for a 25% load change. 20 MHz bandwidth. Measured using 0.47 F ceramic capacitor. Continuous Trip & Restart (Hiccup mode), with auto recovery Maximum Capacitive Load See Models and Ratings table Temperature Coefficient 0.02 %/ C Maximum Units General Characteristic Minimum Efficiency Isolation: Input to Output Isolation Resistance Typical 86 % 60 s/1 s pF kHz At 500 VDC 1500 50.8 W/in3 109 Switching Frequency 450 Power Density Mean Time Between Failure Weight See Models and Ratings table VDC 1500/1800 Isolation Capacitance Notes & Conditions 350 kHrs 0.03 (15.0) lb (g) MIL-HDBK-217F, +25 C GB Environmental Characteristic Minimum Operating Temperature -40 Storage Temperature -50 Case Temperature Humidity Typical Maximum Units Notes & Conditions +100 C See Derating Curve. +125 C +100 C 95 %RH Cooling Non-condensing Natural convection www.xppower.com 2 JWK10 Series DC-DC Converter Safety Approvals Safety Agency Safety Standard Notes & Conditions CB IEC60950-1 ITE UL UL/cUL60950-1 ITE EMC: Emissions Phenomenon Standard Test Level Conducted EN55022 Class A Notes & Conditions EMC: Immunity Test Level Criteria ESD EN61000-4-2 8 kV air discharge, 6 kV contact A Radiated EN61000-4-3 10 V/m A EFT/Burst EN61000-4-4 2 kV A With external capacitor, suggested part is CHEMI-CON KY 330F/100V Surge EN61000-4-5 1 kV A With external capacitor, suggested part is CHEMI-CON KY 330F/100V Conducted EN61000-4-6 10 V rms A Phenomenon Standard Notes & Conditions Mechanical Details Optional Heatsink (-HK) 1.00 (25.4) 0.40 (10.16) 0.40 (10.16) 4 0.80 (20.3) Bottom View 1 0.24 (6.0) 0.40 0.02 (10.16 0.5) 5 2 0.20 (5.08) 1.00 (25.4) 3 0.64 (16.3) Max. 0.10 (2.54) 0.69 (17.46) Max. o 0.04 (1.00) 1.22 (31.0) Max. 0.77 (19.50) Max. Heat-Sink 6 0.30 (7.62) Thermal Pad Clamp Converter 0.10 (2.54) Pin 1 2 3 4 5 6 Notes 1. All dimensions are in inches (mm) 2. Weight: 0.03 lbs (15.0g) approx. 3. Tolerance: X.XX0.01 (X.X0.25) X.XXX0.005 (X.XX0.13) 4. Pin Tolerance: 0.002 (0.05) Application Notes Derating Curve Pin Connections Single +Vin -Vin +Vout No Pin -Vout Remote On/Off Dual +Vin -Vin +Vout Common -Vout Remote On/Off Output Power (%) 100 With optional heatsink (-HK) 0 -40 60 70 100 Ambient Temperature (C) 3 www.xppower.com 11 Feb 16