VPT100-2800S Series
DS90210-2.0 3
SPECIFICATIONS (TCASE = -55°C to +100°C, VIN = +28V ± 5%, Full Load, Unless Otherwise Specified)
ABSOLUTE MAXIMUM RATINGS
Input Voltage (Continuous) 40 VDC Junction Temperature Rise to Case +17°C
Input Voltage (Transient, 1 second) 50 Volts Storage Temperature -55°C to +125°C
Output Power1 100 Watts Lead Solder Temperature (10 seconds) 300°C
Power Dissipation (Full Load, TCASE = +100°C) 18 Watts Weight (Maximum) 90 Grams
Parameter Conditions
VPT100-2812S VPT100-2815S
Units
Min Typ Max Min Typ Max
STATIC
INPUT
Voltage4
Continuous 16 28 40 16 28 40 V
Transient, 1 sec - - 50 - - 50 V
Current Inhibited - - 5 - - 5 mA
No Load - 100 200 - 100 200 mA
Ripple Current Full Load, 20Hz to 10MHz - - 200 - - 200 mAp-p
Inhibit Pin Input4 0 - 1.5 0 - 1.5 V
Inhibit Pin Open Circuit Voltage4 9.0 11.0 14.0 9.0 11.0 14.0 V
UVLO Turn On 14.5 - 15.8 14.5 - 15.8 V
UVLO Turn Off4 14.0 - 15.0 14.0 - 15.0 V
OUTPUT
Voltage
VOUT TCASE = 25°C 11.82 12.0 12.18 14.775 15.0 15.225 V
VOUT TCASE = -55°C to +100°C 11.70 12.0 12.30 14.625 15.0 15.375 V
Power3 0 - 100 0 - 100 W
Current3 VOUT 0 - 8.33 0 - 6.67 A
Ripple Voltage VOUT Full Load, 20Hz to 10MHz - - 150 - - 150 mVp-p
Line Regulation VOUT VIN = 16V to 40V - - 20 - - 20 mV
Load Regulation VOUT No Load to Full Load - - 100 - - 100 mV
EFFICIENCY 86 90 - 86 90 - %
LOAD FAULT POWER DISSIPATION Overload4 - - 24 - - 24 W
Short Circuit - - 24 - - 24 W
CAPACITIVE LOAD4 - - 500 - - 500
F
SWITCHING FREQUENCY 300 340 380 300 340 380 kHz
SYNC FREQUENCY RANGE VH-VL=5V 300 - 380 300 - 380 kHz
Duty Cycle = 50%
ISOLATION 500 VDC 100 - - 100 - - MΩ
MTBF (MIL-HDBK-217F) GM @ TC = 55°C - 344 - - 344 - kHrs
DYNAMIC
Load Step Output Transient VOUT Half Load to Full Load - - 500 - - 500 mVPK
Load Step Recovery2 - - 300 - - 300
Sec
Line Step Output Transient4 VOUT VIN = 16V to 40V - - 300 - - 300 mVPK
Line Step Recovery2, 4 - - 150 - - 150
Sec
Turn On Delay VOUT VIN = 0V to 28V - 6 10 - 6 10 mSec
Turn On Overshoot - 0 50 - 0 50 mVPK
Notes: 1. Dependant on output voltage. 2. Time for output voltage to settle within 1% of its nominal value.
3. Derate linearly to 0 at 110°C. 4. Verified by qualification testing.