SPECIFICATION SHEET
SKYFR-001076: 1480—1526 MHz Single Junc%on Robust
Lead Isolator
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
Revision 1 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • April 2013
1
Applica%ons
Wireless infrastructure
Power amplifiers
Features
Operang frequency range: 1480 to 1526 MHz
BeO free
RoHS compliant
1 2
CW
Figure 1. Block Diagram
Parameter Symbol Test Condition Min Max Units
Input power P
70 140 W
Reverse power P
The device will handle reverse power up to 70W 70 W
Operating temperature range T
OP
-25 +90 °C
Storage temperature range T
STOR
-40 +125 °C
Peak power P
PK
200 500 W
Table 1. Absolute Maximum Ratings
Note: The power rating and reliability of the device will not degrade with an operating temperature of up to +100°C. Exceeding any of the other limits listed here
may result in permanent damage to the device or may reduce device reliability.
SPECIFICATION SHEET • SKYFR-001076
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • April 2013
2
Parameter Symbol Test Condition Min Typical Max Units
Frequency range f 1480 1526 MHz
Impedance 50
Insertion loss IL 1495.9 MHz—
1510.9 MHz 0.20 dB
Insertion loss IL 1480MHz—1526MHz 0.25 dB
Insertion loss ripple IL Peak to peak 0.10 dB
Isolation ISO 25 dB
Return loss RL 25 dB
Intermodulation distortion (Note 2) IMD 2 x 10W CW tones, 1MHz spacing 74 dBc
Phase flatness vs frequency Peak to peak 0.15 degree
Harmonic product generation With 30W CW tone at port 1 -55 dBc
Out of band attenuation @ 2nd harmonics 20 dB
Out of band attenuation 3rd harmonics TBC dB
Table 2. Electrical Specifications (Note 1)
Section Base Material Plating
Lead Bronze Gold
Housing Steel Silver
Table 3. Plating Specification
Manufacturing Part Number Evaluation Board Part Number
SKYFR-001076 MAFX-999999-000PPR
Table 4. Ordering Information
Note 1: Performance is guaranteed under the conditions listed in this table and over the operating temperature range.
Note 2: See Skyworks Application Note, Intermodulation Distortion Measurements of Ferrites, document number 201537 for further details.
SPECIFICATION SHEET • SKYFR-001076
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • April 2013
3
Figure 2. Package Dimensions
Copyright © 2011 Skyworks Solutions, Inc. All Rights Reserved.
Information in the document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a service
to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the information contained herein. Skyworks may
change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to update the materials or information and shall have no responsibility
whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or information provided hereunder,
including the sale, distribution, reproduction or use of any Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR
A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRIDGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EX-
PRESSLY DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS.
SKYWORKS SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENCIAL DAMAGES, INCLUDING WITHOUT
LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED
OF THE POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury, death, physical or environ-
mental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any damages resulting from such improper use or
sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of products outside of published
parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for applications assistance, customer product design, or
damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks, the Skyworks symbol, and “Breakthrough Simplicity” are trademarks or registered trademarks of Skyworks Solutions, Inc. in the United States and other countries. Third-party brands and names are for
identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com and incorporated by reference.
All dimensions in millimeters.
Tolerance: ±0.2mm unless otherwise specified.
Model number, lot code and port designation printed on top side of device.