| latte COMPONENTS 230-OL5 Multitunction Digital Timer 1/16 DIN Timer with Easy-to-use Functions @ Nine output modes accommodate a wide variety of applications. mM AIl parameters set by scroll-through menus accessed from the front panel. Field-selectable time ranges from 0.001 second to 9999 hours. @ High visibility alphanumeric LCD display with built-in backlight. Precision control possible to 0.001 second. MH Four levels of key protection provided. Ordering Information Selectable elapsed time (UP) and time remaining (Down) display. Model H5CR-S only 64 mm deep. Functions 9 field selectable Contact type SPDT relay Solid-state open collector Unit Depth Basic (78 mm) | Standard (100 | Short body (64 | Basic (78mm) | Standard (100 | Short body (64 . mm) mm) mm) mm) Display | Backlit + H5CR-8 H5CR-S -- HS5CR-BS HSCR-SS Non backlit |} HSCR-L Sate HSCR-LS _ Supply AC 24/100 to 240 24/100 to 240 o- 24/100 to 240 24/100 to 240 -- voltages V, 50/60 Hz V, 50/60 Hz V, 50/60 Hz V, 50/60 Hz DC 12 to 24V -- 12 to 24V 12 to 24V -- 12to24V Note: Note: HSCR - LIC L Add the supply voltage to the part number when ordering. = Model Legend 2. Output type classifier Blank: Relay output S: Solid-state output 1. Type classifier e.g., H7CR-B-500 (100 to 240 VDC, 50/60 Hz) L: Basic B: Standard S: Short body Models with a shock prevention cover can be ordered by adding -500 to the end of the model number.H5CR OomRON H5CR m Accessories (Order Separately) Soft cover Y92A-48F 1 Track mounted socket P2CF-08 Rear surface connection socket P3G-08 Shock prevention cover Y92A-48T Mounting Adapter Y92F-30* *Standard with unit Soft cover Shock prevention Adapter cover Y92A-48F1 Y92A-48T Y92F-30 Specifications Model H5CR-L (Basic type) | H5CR-B (Standard type) H5CR-S (Short body type) Classification Digital timer Mounting Panel or Surface mounting Panel mounting External connections 8P socket Screw terminals Enclosure ratings IP40 IP54 (panel surface) Approvals UL CSA File no. 41515 File no. LR22310 Display modes Elapsed time (UP), time remaining (Down) Output modes A, A-1, A-2, A-3, b, b-1, d, E, F Reset system Power reset (except A-3, b-1, and F modes), External, manual, automatic resets (internal according to A-1, b, b-1, d, and E mode operation) Input signals Start, reset inputs | Start, reset, gate, key protect inputs Input method No-voltage input: Via opening and closing of contact Control outputs SPDT contact output and transistor output (NPN open collector) Dispiay LCD without backlight | LCD with backlight Digits 4 digits Max. time settings 9.999 s (0.001 s units), 99.99 s (0.01 s units), 999.9 s (0.1 s unit), 9999 s (1 s unit), 99 min 59's (15 unit), 999.9 min (0.1 min unit), 9999 min (1 min unit), 99 hr 59 min (1 min unit), 999.9 hr (0.1 hr unit), 9999 hr (1 hr unit) Memory backup Backup time for power interruption: Approx. 10 years at 20CHSCR omRON H5CR = Ratings Mode! H5CR-L (Basic type) H5CR-B (Standard type) H5CR-S (Short body type) Rated supply voltage 100 to 240 VAC (50/60 Hz) 100 to 240 VAC (50/60 Hz) 12 to 24 VDC (permissible ripple: 24 VAC (50/60 Hz) 12 to 24 VDC (permissible ripple: 20% max.) 24 VAC (50/60 Hz) 20% max.) Operating voltage range 85% to 110% of rated voltage Power consumption Approx. 3 VA at 50 Hz, 240 VAC; approx. 1 W at 24 VDC Approx. 5 VA at 50 Hz, 240 VAC Approx. 2 W at 24 VDC Reset and control signals Min. pulse width 1 ms/20ms selectable Gate Min. pulse width: Approx. 20 ms Key protect Response time: 1s One-shot time 0.1 to 20 s (select from 7 kinds) or hold Power reset (except A-3, b-1, and F mode) Min. power opening time: 0.5 s Signal, reset, gate inputs No-voltage input ON impedance: ON residual voltage: 2 V max. OFF impedance: 100 kQ min. 1 kQ max. (Approx. 2 MA when 0 Q) Key protect input No-voltage input ON impedance: ON residual voitage: 1 V max. OFF impedance: 100 kQ min. 1 kQ max. (Approx. 2 mA when 0 2) Control outputs Contacts: 5 A at 250 VAC, resistance load (cos = 1) Transistor output: Open collector 100mA at 30 VDC max. residual voltage 2 V max. (Approx. 1 V) Ambient temperature -10 to 55C (with no icing) Storage temperature -25 to 65C (with no icing) Ambient humidity 35% to 85% Case Light gray = Characteristics voltage effects) Repeat accuracy (including temperature and Power start: +0.01% +0.05 s max. Control signal start: 0.005% =0.03 s max. *(rate for set value) Insulation resistance 100 MQ min. (at 500 VDC) (between current-carrying terminal and exposed non-current-carrying metal parts, and between non-continuous contacts) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min (between current-carrying terminal and exposed non-current-carrying metal parts) for 100 to 240 VAC type 1,000 VAC for 24VAC/12 to 24 VDC type Surge voltage 3 kV (between power terminals) for 100 to 240 VAC type, 1 kV for 24 VAC/12 to 24 VDC type 4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) for 100 to 240 VAC type, 1.5 kV for 24 VAC/12 to 24 VDC type Noise immunity +2 kV (between power terminals)(=480 V for 12 to 24 VDC) and =600 V (between input terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 us, 1-ns rise) Static immunity Malfunction: 8 kV; destruction: 15 kV Vibration Destruction 10 to 55 Hz with 0.75-mm single amplitude each in three directions Malfunction 10 to 55 Hz with 0.5-mm single amplitude each in three directions Shock Destruction 300 m/s? (Approx. 30G) each in three directions Malfunction 100 m/s? (Approx. 10G) each in three directions Life expectancy Mechanical 10 million operations min. Electrical 100,000 operations min. (5 A at 250 VAC in load resistance) Weight HSCR-L: Approx. 105 g, HSCR-B: Approx. 160 g, HSCR-S: Approx: 120gomRON H5CR . Nomenclature Display Power indicator Signal input indicator Reset indicator Gate indicator (not included in the HSCR-L) Key protection indicator (not included in the HSCR-L) 6. Gontrol output indicator 7. Present value (character height: 8mm)(Non significant zeroes suppressed) Ponsa mn 8. Set value (character height: 4 mm) Operation key 11. Increment keys (1 to 4) (Used to change the corresponding digit of the set value. Used to change data in the set mode.) 1 6 12. Display key (Switches to the present value 7 display.) a 13. Mode key (Switches from run mode to set mode. Changes items in the " set mode. 14. Reset key (Resets timing and outputs.) (Indicates value in set function mode) 9. Mode indicator 10. Timing indicator = Factory Settings The following table shows the timer settings when it is shipped. Please change the settings as necessary to suit the system before operation. Settings and the display receive power from the internal battery and are therefore unaffected by external power interruptions. Model HSCR-B (Standard)/HSCR-S (Short body) HSCR-L (Basic) Time range --.5 Present value 0.00 s Presets 0.00 s UP/DOWN mode UP Output mode A: Signal on delay (I) Output time Hold Input signal time 20 ms Key protect level KP-1 | o- Note: out a power supply. With the initial settings, there will be no output even if the power supply is connected. External inputs and outputs cannot be used with-H5CR Operation omRON H5CR = Block Diagram LCDs LCD drive System clock LCD reference clock generator|| generator voltage generator 1 1 Set circuit ROM RAM LCD driver Key switch circuits Control One-chip circuits microcom- Input circuits (Re- puter set, control signal, | key protect, gate) Power outage Battery detector Output circuits (OUT) , Power circuits * ' DC input only for HSCR-S .* Power supply is not insulated from 1/O. a I/O Functions Inputs Start signal Stops timing in A-2 and A-3 (power on delay) modes. Starts timing in other modes. Reset Resets present value. (to zero in UP modes, to preset in DOWN mode. Count inputs are not accepted while reset input is ON. Reset indicator lit while reset input is ON. Gate inhibits timer operation. Key protect Makes keys inoperative according to key protect level. Key protected indicator lit while key protect input is ON. Effective when power supply is turned off. Effective when protect terminals are shorted. Outputs Control output (OUT) | Outputs made according to designated output mode when corresponding preset is reached.H5CR omron H5CR = Operational Overview This flowchart shows operation common to all HSCR models. Refer to the following Setting Item Table for details on the operation of specific models. Run mode Press the Setting mode MODE key +> Present vaiue, set value Press the > Timing range DISPLAY key Press the MODE key UP/DOWN mode Press the MODE key Output mode Press the Press the MODE key MODE key Output time Prass the MODE key Note: 1. Set values are changed using the increment keys Input signai time {1 to 4). 2. The large arrows indicate the parameter displayed first Mowe when the mode is changed with the MODE or DISPLAY y key. Key protect level 3. "The key protection is not included in the HSCR-L. |H5CR omRon H5CR & Setting Item Table Mode Setting item Discription Setting procedure Run mode Set value Compared to the present value. Sequence when changing a digit using the increment Determines the timing of the keys (1 to 4). control output according ta the output mode. Oe ied Ged ) Setting mode {| Time range Determines the timing range. Change the timing range with the increment keys (1 to 4). UP/DOWN mode Selects Select UP/DOWN with the increment keys (1 to 4). (UP) Ui~~d (DOWN) Output mode Determines the form of the control | Sequence when changing the mode using the increment output. (Refer to the present value | keys (1 to 4). vs. Output diagrams on page 9 to 11) CR -w Re le RO A-d eb be be de Eo Output time Determines the duration of the Change the output time with the increment keys (1 to 4) control output. Will be displayed when the output -, mode is A, A-1,A-2,A-3.b, or |= = Hol he b-1. Will not be displayed when 2 ise G Gs ly = Sg = Os > Sg > els the output mode is d, E, or F. Input signal time Changes the duration of the Change the duration with the increment keys (1 to 4). control and reset input signals. (1ms) } 29 (20ms) Key protect level Locks certain keys to prevent Sequence when changing the key protect level using the accidental operation. The key Increment keys (1 to 4). protection level, KP-1 to kP-4, determines which keys are Jocked C KP- j= RP-Om KP- Fe kP- y when the key protection input is ON. The locked keys are crossed out in the diagram on the right. 7. 3S 2. 2S =) PRs oe =) SS Note: 1. Changes made in setting mode become effective when run mode is entered. 2. The time range setting appears first when setting mode is entered. 3. *The key protection function is not included in the HSCR-L.HSCR = Examples Run Mode Changing the Set Value To change the set value from 3hr5 min to 4 hrS min, press the 3 key so that the number 4 appears in the hours place. @ Pressing keys 1 through 4 increments the corresponding column by 1. @ The columns can be changed in any order, but the output will be turned ON if the set value is less than the present value. Nonsignificant zeros are suppressed on the set value display. omrRon H5CR TIMER Note: Read Changing Set Values in the Precautions section, pg. 15, before changing the Timer set value during operation. Setting Mode Changing Settings in the Set Mode 1. Press the MODE key to switch from run mode to set mode. The Timer will continue operation if switched from run mode to set mode during operation. @ The MODE key will be locked if the key protection function is enabled. Settings changed in the set mode are not effective until run mode is entered. As the operating conditions will change in this case, always reset operation with the RESET key ora reset input. 2. Press the MODE key to scroll successively through the items that can be set. TIMER TIMER we seme es | | a | [ome eo ie: | | 3. Changing the selected item * Press the MODE key until the desired item appears TIMER cut wax A ries S=) Ce | | Change the item setting by pressing keys 1 through 4. (Press the DISPLAY key to switch back from set mode to run mode.) TIMERomRON H5CR H5CR = Timing Charts The gate input is not included in the HSCR-L. Output mode A: Signal ON delay 1 (Timer resets when power comes on.) Power [ |] if Timing begins at the leading edge of oe tt the start signal. The contro} output will Start signal P J eC ee | be energized when the present value ' ' i ti equals the preset time. The output can Gate ! jal D4 _' fi be sustained until a reset signal is ' ' at rhl gy, applied or power interrupted or for a Reset . fu Fy oe programmable one-shot time period. ' to. topo tyes Pyor thee raf vo 1! ut Control output ' A t aot fl . oI Setvalue -7 77% - re aennetgth 4 - - -th Timing UP 0 diagram Set value DOWN 0 Output mode A-1: Signal ON delay 2 (Timer resets when power comes on.) Power i _| f if Timing begins at the leading edge of 4 ' the start signal. The control output will Start signal J LJ l { r be energized if the start signal is g tot tg \ sustained for a amount of time equal Gate ' fhe fl: ' ' , to the preset time. The output can be ' yt et : ' ! sustained until a reset signal is applied Reset ge TL " : _M ' ' or power interrupted or fora ' toe tt vatyos ' yy programmable one-shot time period. My teeta ' ' fe Control output r trot r t aa Setvalue "7 clr 5 yoacte ine ats Timing YP 0 * * diagram Set value TT - tot tag = 77 ri DOWN 0 Output mode A-2: Power ON delay 1 (Timer resets when power comes on.) Power | _| f Lf Timing begins when power is applied. ' my a Start signals act as a gate input Start signal ! r wan I | wt causing the present value to ???. The i chon mt control output will be energized when Gate . 1t A t,o ! the present value equals the preset ' as ts ' ' 1? time. The output can be sustained Reset ' Owe ES 7, ! until a reset signal is applied or power 1 ait fs vy 1, t, 4 , interrupted or for a programmable Control output 1 fo mot ta Z one-shot time period. 1 ' wa . a 7 T T Set value 1- aot i ely tein tae a Timing UP 0 f : : diagram Set value DOWN 0 Output mode A-3: Power ON delay 2 (Timer does not reset when power comes on.) Power { {ft Lf Timing begins when power is applied. t oo te to Start signals act as a gate input Start signal ' Cl ou as wet causing the present value to ?7?. The . ty oo mt contral output will be energized when Gate mo an the present value equals the preset ' \ ' , ' reo it time. The output can be sustained Reset ' mit m: ,it vifys io until a reset signal is applied or power ot v ' i t reo ft ta tt 7 cr interrupted or for a programmable Control output fo , Peay to f fi nq one-shot time period. r + pt , + Setvalue -- | ed mas ' v Timing UP Oo fap he diagram Setvalue =A - + - pea - DOWN 0 One-shot | Sustained output One-shot outputs can be set to 0.18,0.55,15,55, 105, 20s.OMRON H5CR H5CR Output mode b: Repeat cycle 1 (Timer resets when power comes on.) p [ ml 1 The OFF/ON cycle is initiated at the ower . leading edge of the start signal. The . Oo 00 OY OO 1. output relay will be OFF for the preset Start signal TT ce time, then ON for the preset time. The Gate \ oo Oo nm tts cycle will be repeated until a reset 1 my "oo, ett input is applied or power is at 4 ' i ' Mite pti et interrupted. Reset ' arr r , ' T Y } 1 | ] a ' 1 Control output 1 A - +t TT rT c 7 [ Setvalue ----4+4 m4 deere : rede - ' 1 Timing UP 0 : diagram Set value DOWN 0 p { lf LOTT fT sC{ The OFF/ON cycle is initiated at the ower rt oo. leading edge of the start signal. The . mo | oO os Pes control output will be OFF for the first Start signal ms es cycle. In subsequent cycles the output at os sf i ' 'O of ta will be ON for the programmabie Gate 7 btak 1, PP)! 4 : one-shot time period, then OFF for the ' ii if | Oe remained of the preset time. The cycle Reset ; i t Trt ot ye will be repeated until a reset input is Control output ee ee att d re) applied or power is interrupted. Set value 1-4 pacdares . + preaeee- t ' toa Timing UP 0 ins Tt diagram Set value ~ -ber -R m3 Lhe ~ DOWN 0 Output mode b-1: Repeat cycle 2 (Timer does not reset when power comes on.) Power ( 1f Lf Lf The OFF/ON cycle is initiated at the 4 ' 4 leading edge of the start signal. The . nq eT a mM 1. output relay will be OFF for the preset Start signal TT ; mT time, then ON for the preset time. The Gate ' to '| tf. 7 yh, cycle will be repeated until a reset ' ty, rs input is applied or power is ' ' j ' Thos TW toa, tat interrupted. Reset on - tet Controi output : : : _ - | Set value 1 Timing UP 0 diagram Set value DOWN 0 The OFF/ON cyele is initiated at the Power i 4 [ leading edge of the start signal. The . oe] control output will be OFF for the first Start signal Hd ; O Di ; i H cycle. in subsequent cycles the output 4 ' reheat will be ON for the programmable Gate : A q QO. 4 a one-shot time period, then OFF for the tu ' pore ta tl remained of the preset time. The cycle Reset 7 A TT, : [I . : . r+ * will be repeated until a reset input is Control output ' " soe A applied or power is interrupted. Set value 4 . vi Timing YP 0 diagram Set value DOWN 0 [of Sustained output | One-shot 10 One-shot outputs can be set to 0.1s5,0.55,15,58,105, 15so0r20s.HSCR H5CR omRON Output mode d: Signal OFF delay (Timer resets when power comes on.) Power L _ | i t 1 t ' Start signal np f 1 Py vena ' 1 ' ' yes Gate rts f] t Moi, ' ' oo? ' ryt ' 4 1 Reset pees ft ry Hl Control output fr TT 1 : | Fl r ; rm Setvalue ----- Va ein dem eee Pen t-te e - Timing UP 0 4 | < ; 14 diagram Set value a DOWN 0 The control output is energized at the leading edge of the start signal. Timing begins at the trailing edge of the start signal. The control output is de-energized when the present vatue equals the preset time. Output mode E: Interval (Timer resets when power comes on.) Power I LI are oO Start signal * 1 Gate Reset Contro} output Set value Timing UP 0 diagram Set value DOWN 0 ~-bP--J]--h Timing begins on the leading edge of the start signal. The control output is only energized during timing. The timer is reset when power is interrupted or a reset signal is applied. Output mode F: Cumulative (Timer does not reset when power comes on.) Power L Lt Start signai Gate Reset | foe bf = ole Control output Set value Timing UP 0 diagram Set value DOWN 0 Timing begins on the leading edge of the start signal. The control output is energized when the cumulative elapsed time of the start signal is equal to the preset time. The output is sustained until! power is interrupted or a reset signal applied.H5CR Dimensions omRON H5CR Note: All units are in millimeters uniess otherwise indicated. HSCR-L Panel Mounting/Surface Mounting HSCR-B Panel Mounting H5CR-S Panel Mounting 84.0 143 63.7 6 0.7 r 48 Mm - 44.8 Bees) int = Es Be M3.5 terminal screw 48 16 100 (effective length: 6 mm) L f al V : a a q == g M3.5 terminal screw 6 _ (effective length: 6 mm) - 48 | 64 / f 48 a af 44.8 Bae] q a Se) qH5SCR H5CR-L Panel Mounting Adapter omRrRonNn P3G-08 Rear surface Panel y92F-30 { adapter / f qi Poe ayy Panel yg2F-30 / Panel mounting connection socket H5CR Surface Mounting P2CF-08 f Panel mounting adapter c= | = = 44.8 Panel Y92F-30 Panel mounting adapter Lo M1 44.8 = | + Panel Cutouts Panel cutouts are as shown below. (according to DIN43700). [--60 min.! | 453 | i ] | | 4st +p Pi | 60 min fae + | Note 1. The mounting panel thickness should be 1 to 4mm. 2. itis possible to mount timers side by side, but only horizontally. A , = {nx 45 + (n-1) x 3.5} 285H5CR OomRON H5CR Installation = Terminal Arrangement H5CA-L (Basic) H5CR-B (Standard) H5CR-S (Short body) Contact output Contact output Contact output . Stan signal input Start signal input Start signal \ Reset input (Gate input | [Resetinput_| | [Gate input | Reset Input use 0 V Key protect input Input use 0 V Key protect input | 4 r ty j ! 3 e|7 [8 is | 10 6|7 {8 |s [10 or ioe ov | / \ Unused | 1 12 | Unused Unused | 11 12 | Unused ~ OUT OUT a 100 to 240 VAC/ 24 VAC t i | () 1f2fafe fs 1f2[3]4]s F 12 to 24 VDC 100 to 240 VAC/24 VAC wt ay 121024 VOC Transistor output Transistor output Transistor output Stan signal input (Stan signal input_] Start signal ant signal input 7 [Reset input_| j [Gate input (_Resetinput_| | [Gate input | \ - Fogo mput use + Levpoetpa| Input use 0 V Key protect input t i preset 6 | ? | 8 | 9 [10 4 6 | 7 cE | [ 10 ov / Unused | 1 12 | Unused OUT Unused | 11 out 12 | Unused (Dy 100 to 280 VAC! 24 VAC o\ C1, oH f2ya fs [s Tele Te 12 to 24 VDC 100 to 240 VAC/24 VAC 12 to 24 VDC {+} Note: Do not connect unused terminals. = Connections The inputs of the HSCR are no-voltage (short circuit or open) inputs. No-contact Input Contact Input No-contact input (NPN Transistor) Sensor -- Sensor Timer Timer ' +V_ 1(30 V max.} t2 VDC Start signal, reset, etc. 12 VOC Start signal, reset, etc. Start signal. reset. etc. Input use 0 V O Input use 0 V input use 0 V ____] __-l High: transistor ON High: contact ON High: transistor ON No-voltage Input Signal Levels 1. High level Transistor ON No-contact | Residual voltage: 2 V max. input Impedence when ON: 1 kQ max. 2. Low level Transistor OFF impedence when OFF: 100 k2 min. Contact Use contacts which can adequately input switch 2 mA at5VH5CR Precautions omrRon H5CR Power Supplies The input circuit is not insulated from the power supply circuit. The internal circuit might be damaged by a surrounding AC Circuit, SO use an insulated AC power supply with equipment connected to the input circuit. If power is interrupted for less than 10 ms, operation will continue normally. If power is interrupted for between 10 and 500 ms, operation will be inconsistent, and timing may stop or reset, depending on the made. Connect the power supply voitage through a relay or switch in such a way that the voltage reaches a fixed value immediately. Depending on switching frequency, current surges may degrade relay contacts; relays with a capacity greater than 10 A are recommended. Input and Output Do not use external sources to increase the voltage of input signals (control signal, reset, gate, and key protection). Be sure that the load of the contro output (contact, transistor) is fess than the maximum values indicated in the specifications. if the output load exceeds the recommended value, the lifespan of the contact output type will be shortened dramaticaily, and the transistor of the transistor output type will be damaged. The transistor output is insulated from the internal circuitry by a photocoupler, so either NPN or PNP transistors can be used. = Self-diagnostic Function The following displays will appear if an error occurs. The present value and output enter the same status as after pressing the RESET key. Display Error Output Correction Set status E} CPU OFF Press No RESET key | change E2 Memory Set at the factory m Changing Set Values The Timer set value can be changed while the timer is operating, so a high value can be set temporarily to inactivate the timer, or a low value can be set to activate the timer more quickly. (If the set value is changed accidentally during operation, the timer might be activated. Therefore, turn the key protection input ON unless the set value is being changed.) * To avoid changing the output when changing the set vaiue, it is recommended to begin changing the set value by entering a large number in the higher digit. = Operating Environment When using the Timer in an area with much electronic noise, separate the Timer, wiring, and the equipment which generates the input signals as far as possible from the noise sources. It is also recommended to shied the input signal wiring to prevent electronic interference. Organic solvents (such as paint thinner), as well as very acidic or basic solutions might damage the outer casing of the Timer. = Other e When the timer is installed in a control box and tests are conducted which may damage the Timers internal circuitry (for example, a test measuring the maximum voltage difference between the control circuit and metal components), remove the Timer from the control box or short circuit the terminals. Caution This product contains a lithiurn battery. Lithium batteries ex- plode if incinerated. Dispose of the Digital Timer as anon-com- bustible item.