ø30mm
Switches & Pilot Lights
2
ø30 ø30 Series Switches & Pilot Lights (Selection Guide)
Function XN Series Emergency Stop Switch HN Series Emergency
Stop Switch
Category Plastic Bezel Flush Bezel Padlockable
Pushlock Pull/Turn Reset
Pushlock Pull/Turn Reset
Pushlock Turn Reset Pushlock Turn Reset
Shape
ø60mm
Mushroom
Model XN1E-BV4
XN1E-LV4
XN1E-TV4 XN1E-BV5 XN5E-BV4
XN5E-LV4
XN5E-TV4
XN4E-BL4
XN4E-LL4
XN4E-TL4
HN1E-BV4
HN1E-LV4
Page 7 7 8 9 14
Function Pushbutton
Category Flush Extended
Extended with Half Shroud Extended with Full Shroud
Momentary/Maintained
Shape
Model ABN1
AON1
(Diecast)
ABD1
AOD1
ABN2
AON2
(Diecast)
ABD2
AOD2
ABN2G
AON2G
(Diecast)
ABGD2
AOGD2
ABN2F
AON2F
(Diecast)
ABFD2
AOFD2
Page 21 74 21 74 21 74 21 74
Function Pushbutton
Category Mushroom Mushroom with Full
Shroud Palm Mushroom Jumbo Mushroom with
Shallow Shroud Jumbo Mushroom with
Deep Shroud
Momentary/Maintained Momentary
Shape
Model ABN3
AON3
(Diecast)
ABD3
AOD3 ABN3G (Diecast)
ABGD3
AOGD3 ABN4 (Diecast)
ABD4 ABN4G (Diecast)
ABGD4 ABN4F (Diecast)
ABFD4
Page 22 75 22 75 22 75 22 75 22 75
Function Pushbutton
Category Mushroom Pushlock Turn
Reset Mushroom Push Turn
Lock Mushroom Pushlock Key
Reset
Shape
Model AVN3 (Diecast)
AVD3 AJN3 (Diecast)
AJD3 ABN3K
Page 23 76 23 76 23
3
ø30 Series Switches & Pilot Lights (Selection Guide) ø30
Function Pushbutton
Category Pin Lock Mushroom Pull Mushroom Push-Pull Square Flush
Momentary
Shape
Model (Diecast)
ABD8P ATN23 (Diecast)
AZD3 ATN21
ATN22 (Diecast)
AYD31 UBQN1
Page 76 24 76 24 76 22
Function Pushbutton Twin Maintained Pushbutton
Category Square Extended Square Twin Square Twin Flush Twin Maintained Mushroom Twin Main-
tained
Momentary Momentary Maintained
Shape
Model UBQN2 UWQN1 UWQN2 ABBN11 ABBN33
Page 22 25 25 25 25
Function Pilot Light (LED)
Category Dome Square Rectangular (Marking)
Shape
Model APN1
APNE1
(Diecast)
APD1
APDE1 UPQN3B UPQN4
UPQNE4
Page 26 77 27 27
4
ø30 ø30 Series Switches & Pilot Lights (Selection Guide)
Function Illuminated Pushbutton (LED)
Category Extended Extended with
Half Shroud Extended with
Full Shroud Mushroom Mushroom Pushlock
Turn Reset
Momentary/Maintained
Shape
Model
ALN2
ALNE2
AOLN2
AOLNE2
(Diecast)
ALD2
AOLD2
ALGN2
ALGNE2
AOLGN2
AOLGNE2
ALFN2
ALFNE2
AOLFN2
AOLFNE2
(Diecast)
ALFD2
AOLFD2
ALN3
ALNE3
AOLN3
AOLNE3
(Diecast)
ALD3
AOLD3
AVLN3
AVLNE3
(Diecast)
AVLD3
AVLDE3
Page 29 78 30 31 79 32 80 33 81
Function Illuminated Pushbutton
(LED)
Category Mushroom Push
Turn Lock
Shape
Model AJLN3
Page 33
Function Selector Switch
Illuminated Selector Switch
Category Knob Lever Key Knob
Shape
Model ASN
ASTN (Diecast)
ASD ASNL
ASTNL
(Diecast)
ASDLASNK
ASTN
K
(Diecast)
ASDKASLN (Diecast)
ASLD
Page 34, 41 82 36, 42 83 38, 43 84 44 85
5
ø30 Series Switches & Pilot Lights (Selection Guide) ø30
Function Selector Pushbutton Mono-Lever Switch
Category Ring Lever Standard Interlocking
Shape
Model ABN (Diecast)
ASBD2 ABNL(Diecast)
ASBD2L ARN
ARNS ARNL
Page 46 87 46 87 48 48
Function Cam Switch
Category Knob Key Enclosed Spring Return
Enclosed
Shape
(ACSNO only) (ACSNK only)
Model ACSNO
ACSSO ACSNK
ACSSK UCSQO UCSQM
Page 51 51 51 51
6
ø30 mm, 4-contact Emergency Stop Switch.
Padlockable and flush bezel are available.
Direct Opening Action
•
Padlockable, ush bezel, ø60mm jumbo mushroom,
illuminated, LED push-on are available.
•
IDEC’s original “Safe break action” and reverse energy
structure ensure the highest level of safety.
•
Safety lock mechanism (IEC 60947-5-5, 6.2)
•
Direct opening action mechanism (IEC 60947-5-5, 5.2,
IEC60947-5-1, Annex K)
•
Short depth behind the panel – only 47.7 mm for 4-con-
tact, illumi nated (ush bezel: 60.4 mm, padlockable: 61.4
mm)
•
Padlockable can be locked using padlocks when latched
(main contact: OFF). The rugged aluminum diecast
shroud allows for installing a maximum of 20 padlocks
using a hasp (total weight: 1500g maximum).
•
Gold-plated silver contacts.
•
Red (Munsell 5R4/12) or bright red (Munsell 7.5R4.5/14)
colors are available.
Standards
Applicable Stan-
dards Mark File No. or Organization
UL508
CSA C22.2 No. 14
UL/c-UL File No. E68961
(padlockable only)
IEC60947-5-5
UL991
NFPA79 UL Listing File No. E305148
EN60947-5-5
TÜV SÜD
EU Low Voltage Directive
GB14048.5 CCC No. 2008010305290010
Contact Ratings
NC main contacts (black)/NO monitor contacts (blue)
Rated Insulation Voltage (Ui) 250V
Rated Thermal Current (Ith) 5A
Rated Operating Voltage (Ue) 30V 125V 250V
Rated Operating Current
Main
Contacts
AC
50/60 Hz
Resistive Load
(AC-12) 5A 3A
Inductive Load
(AC-15) 3A 1.5A
DC
Resistive Load
(DC-12) 2A 0.4A 0.2A
Inductive Load
(DC-13) 1A 0.22A 0.1A
Monitor
Contacts
AC
50/60 Hz
Resistive Load
(AC-12) 1.2A 0.6A
Inductive Load
(AC-14) 0.6A 0.3A
DC
Resistive Load
(DC-12) 2A 0.4A 0.2A
Inductive Load
(DC-13) 1A 0.22A 0.1A
Contact Material Gold-plated Silver
•
Minimum applicable load: 5V AC/DC, 1 mA (reference value)
(May vary depending on the operating conditions and load types.)
•
The rated operating currents are measured at resistive/inductive load
types specied in IEC 60947-5-1.
Illumination Ratings (LED)
Rated Voltage Operating Voltage Rated Current
24V AC/DC 24V AC/DC ±10% 15 mA
Specifications
Applicable Standards
IEC60947-5-1, EN60947-5-1
IEC60947-5-5, EN60947-5-5
JIS C8201-5-1, UL508, UL991, NFPA79
CSA C22.2 No. 14, GB14048.5
Operating Temperature Non-illuminated: –25 to +60°C (no freezing)
Illuminated: –25 to +55°C (no freezing)
Storage Temperature –45 to +80°C
Operating Humidity 45 to 85% RH (no condensation)
Minimum Force Required for
Direct Opening Action 80N
Minimum Operator Stroke
Required for Direct
Opening Action
4.0 mm
Maximum Operator Stroke 4.5 mm
Contact Resistance 50 mΩ maximum (initial value)
Insulation Resistance 100 MΩ minimum (500V DC megger)
Overvoltage Category II
Impulse Withstand Voltage 2.5 kV
Pollution Degree 3
Operating Frequency 900 operations/hour
Shock Resistance Operating extremes: 150 m/s2
Damage limits: 1000 m/s2
Vibration Resistance
Operating extremes:
10 to 500 Hz, amplitude 0.35 mm, acceleration 50 m/s2
Damage limits:
10 to 500 Hz, amplitude 0.35 mm, acceleration 50 m/s2
Durability
(at 900 operations/h,
on-duration 40%)
Mechanical: 250,000 operations minimum
Electrical: 100,000 operations minimum
250,000 operations minimum
(24V AC/DC, 100 mA)
Degree of Protection Operator: IP65 (IEC60529)
Terminal: IP20 (when XW9Z-VL2MF is installed)
Short-circuit Protection 250V/10A fuse (Type aM, IEC60269-1/IEC60269-2)
Conditional Short-circuit
Current 1000A
Terminal Style M3 screw terminal
Recommended Tighten ing
Torque for Terminal Screw 0.6 to 1.0 N·m
Recommended Tighten ing
Torque for Locking Ring 2.5 N·m
Applicable Wire Size 0.75 to 1.25 mm2 (AWG18 to 16)
Total Weight of a Hasp and
Padlocks 1500g maximum (padlockable)
Reinforced Insulation
(IEC 60664-1)
Between live part and metal bezel
(ush bezel, padlockable)
Weight
83g (XN1E-LV404Q4MR)
93g (XN1E-BV504MR)
89g (XN5E-LV404Q4MR)
120g (XN4E-LL404Q4MR)
XN Series Emergency Stop Switches
ø30
XN Series Emergency Stop Switches ø30
7
XN
Plastic Bezel
Non-illuminated Pushlock Pull/Turn Reset (Solder Terminal)
Shape NC Main
Contact NO Monitor
Contact
Part No. Operator
Color Code
IP20 Fingersafe Terminal w/Terminal Cover
ø40mm Mushroom 1NC XN1E-BV401MFXN1E-BV401M
R: Red
RH: Bright red
2NC XN1E-BV402MFXN1E-BV402M
3NC XN1E-BV403MFXN1E-BV403M
4NC XN1E-BV404MFXN1E-BV404M
1NC 1NO XN1E-BV411MFXN1E-BV411M
2NC 1NO XN1E-BV412MFXN1E-BV412M
3NC 1NO XN1E-BV413MFXN1E-BV413M
2NC 2NO XN1E-BV422MFXN1E-BV422M
ø60mm Jumbo Mushroom 1NC XN1E-BV501MFXN1E-BV501M
2NC XN1E-BV502MFXN1E-BV502M
3NC XN1E-BV503MFXN1E-BV503M
4NC XN1E-BV504MFXN1E-BV504M
1NC 1NO XN1E-BV511MFXN1E-BV511M
2NC 1NO XN1E-BV512MFXN1E-BV512M
3NC 1NO XN1E-BV513MFXN1E-BV513M
2NC 2NO XN1E-BV522MFXN1E-BV522M
•Specify a color code in place of in the Part No.
•Only solid wires can be used on the IP20 ngersafe terminal switches.
Illuminated Pushlock Pull/Turn Reset (Solder Terminal)
Shape
Illumination
Rated
Voltage NC Main
Contact NO Monitor
Contact
Part No. Operator
Color
IP20 Fingersafe
Terminal w/Terminal Cover
ø40mm Mushroom
LED 24V
AC/DC
1NC XN1E-LV401Q4MFR XN1E-LV401Q4MR
Red only
2NC XN1E-LV402Q4MFR XN1E-LV402Q4MR
3NC XN1E-LV403Q4MFR XN1E-LV403Q4MR
4NC XN1E-LV404Q4MFR XN1E-LV404Q4MR
1NC 1NO XN1E-LV411Q4MFR XN1E-LV411Q4MR
2NC 1NO XN1E-LV412Q4MFR XN1E-LV412Q4MR
3NC 1NO XN1E-LV413Q4MFR XN1E-LV413Q4MR
2NC 2NO XN1E-LV422Q4MFR XN1E-LV422Q4MR
•Only solid wires can be used on the IP20 ngersafe terminal switches.
Illuminated Push-ON Pushlock Pull/Turn Reset (Solder Terminal)
Shape
Illumination
Rated
Voltage NC Main
Contact NO Monitor
Contact
Part No. Operator
Color
IP20 Fingersafe
Terminal w/Terminal Cover
ø40mm Mushroom
LED 24V
AC/DC
2NC XN1E-TV402Q4MFR XN1E-TV402Q4MR
Red only3NC XN1E-TV403Q4MFR XN1E-TV403Q4MR
2NC 1NO XN1E-TV412Q4MFR XN1E-TV412Q4MR
•Push-ON is illuminated when the operator is latched, and turns off when reset.
•Only solid wires can be used on the IP20 ngersafe terminal switches.
ø30 XN Series Emergency Stop Switches
8
Flush Bezel
Non-illuminated Pushlock Pull/Turn Reset (Solder Terminal)
Shape NC Main
Contact NO Monitor
Contact
Part No. Operator
Color Code
IP20 Fingersafe Terminal w/Terminal Cover
ø40mm Mushroom 1NC XN5E-BV401MFXN5E-BV401M
R: Red
RH: Bright red
2NC XN5E-BV402MFXN5E-BV402M
3NC XN5E-BV403MFXN5E-BV403M
4NC XN5E-BV404MFXN5E-BV404M
1NC 1NO XN5E-BV411MFXN5E-BV411M
2NC 1NO XN5E-BV412MFXN5E-BV412M
3NC 1NO XN5E-BV413MFXN5E-BV413M
2NC 2NO XN5E-BV422MFXN5E-BV422M
•Specify a color code in place of in the Part No.
•Only solid wires can be used on the IP20 ngersafe terminal switches.
Illuminated Pushlock Pull/Turn Reset (Solder Terminal)
Shape
Illumination
Rated
Voltage NC Main
Contact NO Monitor
Contact
Part No. Operator
Color
IP20 Fingersafe
Terminal w/Terminal Cover
ø40mm Mushroom
LED 24V
AC/DC
1NC XN5E-LV401Q4MFR XN5E-LV401Q4MR
Red only
2NC XN5E-LV402Q4MFR XN5E-LV402Q4MR
3NC XN5E-LV403Q4MFR XN5E-LV403Q4MR
4NC XN5E-LV404Q4MFR XN5E-LV404Q4MR
1NC 1NO XN5E-LV411Q4MFR XN5E-LV411Q4MR
2NC 1NO XN5E-LV412Q4MFR XN5E-LV412Q4MR
3NC 1NO XN5E-LV413Q4MFR XN5E-LV413Q4MR
2NC 2NO XN5E-LV422Q4MFR XN5E-LV422Q4MR
•Only solid wires can be used on the IP20 ngersafe terminal switches.
Illuminated Push-ON Pushlock Pull/Turn Reset (Solder Terminal)
Shape
Illumination
Rated
Voltage NC Main
Contact NO Monitor
Contact
Part No. Operator
Color
IP20 Fingersafe
Terminal w/Terminal Cover
ø40mm Mushroom
LED 24V
AC/DC
2NC XN5E-TV402Q4MFR XN5E-TV402Q4MR
Red only3NC XN5E-TV403Q4MFR XN5E-TV403Q4MR
2NC 1NO XN5E-TV412Q4MFR XN5E-TV412Q4MR
•Push-ON is illuminated when the operator is latched, and turns off when reset.
•Only solid wires can be used on the IP20 ngersafe terminal switches.
XN Series Emergency Stop Switches ø30
9
XN
Padlockable
Non-illuminated Pushlock Pull/Turn Reset (Padlockable)
Shape NC Main
Contact NO Monitor
Contact
Part No. Operator
Color
IP20 Fingersafe Terminal w/Terminal Cover
ø44mm Mushroom 1NC XN4E-BL401MFRH XN4E-BL401MRH
Bright red only
2NC XN4E-BL402MFRH XN4E-BL402MRH
3NC XN4E-BL403MFRH XN4E-BL403MRH
4NC XN4E-BL404MFRH XN4E-BL404MRH
1NC 1NO XN4E-BL411MFRH XN4E-BL411MRH
2NC 1NO XN4E-BL412MFRH XN4E-BL412MRH
3NC 1NO XN4E-BL413MFRH XN4E-BL413MRH
2NC 2NO XN4E-BL422MFRH XN4E-BL422MRH
•Only solid wires can be used on the IP20 ngersafe terminal switches.
•Padlocks and hasps are not supplied with the emergency stop switches and must be ordered separately. See page 12.
Illuminated Pushlock Pull/Turn Reset (Padlockable)
Shape
Illumination
Rated
Voltage NC Main
Contact NO Monitor
Contact
Part No. Operator
Color
IP20 Fingersafe
Terminal w/Terminal Cover
ø44mm Mushroom
LED 24V
AC/DC
1NC XN4E-LL401Q4MFR XN4E-LL401Q4MR
Red only
2NC XN4E-LL402Q4MFR XN4E-LL402Q4MR
3NC XN4E-LL403Q4MFR XN4E-LL403Q4MR
4NC XN4E-LL404Q4MFR XN4E-LL404Q4MR
1NC 1NO XN4E-LL411Q4MFR XN4E-LL411Q4MR
2NC 1NO XN4E-LL412Q4MFR XN4E-LL412Q4MR
3NC 1NO XN4E-LL413Q4MFR XN4E-LL413Q4MR
2NC 2NO XN4E-LL422Q4MFR XN4E-LL422Q4MR
•Only solid wires can be used on the IP20 ngersafe terminal switches.
•Padlocks and hasps are not supplied with the emergency stop switches and must be ordered separately. See page 12.
LED Push-ON Pushlock Pull/Turn Reset (Padlockable)
Shape
Illumination
Rated
Voltage NC Main
Contact NO Monitor
Contact
Part No. Operator
Color
IP20 Fingersafe
Terminal w/Terminal Cover
ø44mm Mushroom
LED 24V
AC/DC
2NC XN4E-TL402Q4MFR XN4E-TL402Q4MR
Red only3NC XN4E-TL403Q4MFR XN4E-TL403Q4MR
2NC 1NO XN4E-TL412Q4MFR XN4E-TL412Q4MR
•Push-ON is illuminated when the operator is latched, and turns off when reset.
•Only solid wires can be used on the IP20 ngersafe terminal switches.
•Padlocks and hasps are not supplied with the emergency stop switches and must be ordered separately. See page 12.
ø30 XN Series Emergency Stop Switches
10
Dimensions
Non-illuminated
Illuminated/Push-ON
Plastic Bezel
IP20 Fingersafe
3347.7
20.1 18.5
37
ø40
33.0 +0.5
0
4.8
+0.2
0
ø30.5
R0.8max.
+0.5
0
Panel Cut-out
Panel Thickness 1 to 5
IP20 Cover
XW9Z-VL2MF
ø40 mm
Mushroom
ø60 mm
Jumbo Mushroom
33
ø
60
Rubber Gasket
Locking Ring
M3 Terminal
Screws
3347.7
20.1 18.5
ø40
Panel Thickness
1 to 5
37
Terminal Cover
XW9Z-VL2M
Rubber Gasket
Locking Ring
M3 Terminal
Screws
33.0
+0.5
0
4.8
+0.2
0
R0.8 max.
ø30.5
+0.5
0
Panel Cut-out
ø40 mm
Mushroom
ø60 mm
Jumbo Mushroom
33
ø60
Push-ONIlluminated
3347.7
20.1 18.5
37
33.0
+0.5
0
4.8
+0.2
0
R0.8 max.
ø30.5
+0.5
0
Panel Cut-out
Rubber Gasket
Locking Ring
M3 Terminal
Screws
IP20 Cover
XW9Z-VL2MF Panel Thickness 1 to 5
ø40
Push-ONIlluminated
3347.7
20.1 18.5
37
33.0
+0.5
0
4.8
+0.2
0
R0.8 max.
ø30.5+0.5
0
Panel Cut-out
Panel Thickness 1 to 5
Terminal Cover
XW9Z-VL2M
Rubber Gasket
Locking Ring
M3 Terminal
Screws
ø40
w/Terminal Cover
w/Terminal Cover
IP20 Fingersafe
Non-Illuminated
All dimensions in mm.
Flush Bezel
IP20 Fingersafe w/Terminal Cover
Illuminated/Push-ON
IP20 Fingersafe
w/Terminal Cover
ø40
33.0
+0.5
0
4.8+0.2
0
ø30.5
R0.8max.
+0.5
0
Panel Cut-out
ø41
2160.4
20.1 18.5
Panel Thickness 1 to 5
37
Rubber Gasket
Locking Ring
M3 Terminal
Screws
IP20 Cover
XW9Z-VL2MF
ø41
2160.4
20.1 18.5
37
ø40
33.0
+0.5
0
4.8
+0.2
0
ø30.5
R0.8 max.
+0.5
0
Panel Cut-out
Panel Thickness 1 to 5
Terminal Cover
XW9Z-VL2M
Rubber Gasket
Locking Ring
M3 Terminal Screws
Push-ONIlluminated
ø41
2160.4
20.1 18.5
37
Rubber Gasket
Locking Ring
M3 Terminal Screws
ø40
33.0 +0.5
0
4.8
+0.2
0
ø30.5
R0.8 max.
+0.5
0
Panel Cut-out
Panel Thickness 1 to 5
Terminal Cover
XW9Z-VL2M
Push-ONIlluminated
ø40
ø41
2160.4
20.1 18.5
37
33.0
+0.5
0
4.8
+0.2
0
ø30.5
R0.8 max.
+0.5
0
Panel Cut-out
Panel Thickness 1 to 5
IP20 Cover
XW9Z-VL2MF
Rubber Gasket
Locking Ring
M3 Terminal Screws
XN Series Emergency Stop Switches ø30
11
XN
Dimensions
Mounting Hole Layout LED Unit Internal Circuit
Terminal Arrangement (Bottom View)
37
Panel Thickness 1 to 6
IP20 Cover
XW9Z-VL2MF
ø44
33.0
+0.5
0
4.8
+0.2
0
R0.8 max.
ø30.5
+0.5
0
Panel Cut-out
61.4
59.9
20.1 18.5
43
Rubber Gasket
Locking Ring
M3 Terminal Screws
Push-ONIlluminated
61.4
59.9
20.1 18.5
43
37
ø44
33.0
+0.5
0
4.8
+0.2
0
R0.8 max.
ø30.5
+0.5
0
Panel Cut-out
Panel Thickness 1 to 6
Terminal Cover
XW9Z-VL2M
Rubber Gasket
Locking Ring
M3 Terminal Screws
Push-ONIlluminated
Non-illuminated
Illuminated/Push-ON
Padlockable
IP20 Fingersafe
w/Terminal Cover
w/Terminal CoverIP20 Fingersafe
ø30.5 +0.5
0
X
Y
X1
X2
R
LED
LED chip
Protection Diode
Resistor
X Y
Plastic Bezel 70 mm minimum
Flush Bezel
•The values shown above are the minimum dimen-
sions for mounting with other ø30 mm pushbuttons.
For other switches & pilot lights of different sizes
and styles, determine the values according to the
dimensions, operation, and wiring convenience.
•For padlockable, determine the values accord ing to
the size and number of padlocks and hasp.
TOP
Left Right
TOP
Left Right
TOP
Left Right
12
12
21
12
43
34
43
12
21
12
21
21
TOP
X2
LED
X1
Left Right
TOP
X2
LED
X1
Left Right
TOP
X1
LED
X2
Left Right
12
43
12
21
34
43
12
21
12
12
21
21
LED
TOP
X1 X2
Left Right
12
12
21
LED
TOP
X1 X2
Left Right
34
12
21
•Contact
•Contact Number (1-4)
TOP
(Example: 1NO-3NC contact)
Left Right
11 12
34 33
21 22
42 41
1-2: NC main contact (black)
3-4: NO monitor contact (blue)
Starting with the contact
of TOP side, in a counter-
clockwise direction.
ø3.2 min.
Wire
Insulation Tube
Crimping
Terminal
• Be sure to install an insulating tube on the crimping terminal.
Only solid wire can be
used for IP20.
Applicable Crimping Terminal
Ring Terminal Spade Terminal
Solid Wire
4.7 to 5.9
ø6.0 max.
4.7min. 6.2 max.
ø1.2 max.
3.0 max. 4.7 to 5.9
4.7 to 5.9
3.2 min.
6.0 max.
Crimping Terminal
Insulation Tube
Wire
With 1NO monitor
contact (blue)
NC main
contacts (black) only
1NC: Terminals on right
2NC: Terminals on right
and left
3NC: Terminals on right,
left, and top
1NC: Terminals on top
2NC: Terminals on right
and left
Non-illuminated
Illuminated
With 2NO monitor
contacts (blue)
With 1NO monitor
contact (blue)
NC main
contacts (black) only
With 2NO monitor
contacts (blue)
1NC: Terminals on right
2NC: Terminals on right
and left
3NC: Terminals on right,
left, and top
1NC: Terminals on top
2NC: Terminals on right
and left
Push-ON
With 1NO monitor
contact (blue)
NC main
contacts (black) only
2NC: T erminals on right
and left
3NC: Terminals on right,
left, and top
All dimensions in mm.
ø30 XN Series Emergency Stop Switches
12
Accessories and Replacement Parts
Name & Shape Material Part No. Ordering No. Package
Quantity Remarks
PPE XW9Z-VL2M XW9Z-VL2MPN02 2
•Black
•Used for screw terminals.
•Attached to IP20 protection cover units.
Polyamide
XW9Z-VL2MF XW9Z-VL2MF-
PN02 2
•Black
•Used to change terminal cover to IP20
ngersafe terminal.
•Only solid wires can be used. Once installed,
IP20 terminal cover cannot be removed.
Brass XN9Z-T1 XN9Z-T1 1
•Used to tighten the locking ring when installing
the XN emergency stop switch onto a panel.
Steel
Trivalent
chromate
plating
TWST-T1 TWST-T1 1
•Used to tighten the locking ring when installing
the XN emergency stop switch onto a panel.
•The XN series emergency stop switches are supplied with either terminal cover or IP20 ngersafe terminal cover.
•Padlocks and hasps are not supplied and must be ordered separately.
Nameplates (for ø30 Emergency Stop Switches)
Description & Shape Legend Part No. Package
Quantity Dimensions (mm)
(blank) HNAV-0
1
Polyamide
Mounting panel thickness
XN4E-L4: 1.0 to 4.5 mm
XNE-V4: 1.0 to3.5 mm
EMERGENCY STOP HNAV-27
Plate color: Yellow (Munsell 2.5Y 8/10 or equivalent),
Legend: Black
Terminal Cover
IP20 Fingersafe
Terminal Cover
Ring Wrench
90
ø38
Ring Wrench
49.5
52
20.5
23.777
1.0
1.5
ø60
ø30
Padlock and Hasp
Padlocks and hasps of the following specications can be used
with padlockable emergency stop switches.
Padlock Size
A B C D
7 mm maximum 19 mm minimum 39 mm minimum 15 mm minimum
(Note)
Note: When the padlock is installed from the side of the bezel, dimension D
requires a minimum of 6 mm. When the padlock is installed from the
front of the button, dimension D requires a minimum of 15 mm.
Use only padlocks or hasps that satisfy the specications shown
on the left. The maximum total weight for padlocks and hasps is
1500g.
Make sure that the total weight does not exceed 1500g, otherwise
the XN emergency stop switch may be damaged.
Make sure that locking and unlocking of the padlock and hasp do
not interfere with other devices.
Padlocks and hasps are available from the following manufacturers.
Manufacturer URL
PANDUIT CORP. http://www.panduit.com/
Master Lock® Company LLC http://www.masterlock.com/
B A
C
D
Manufacturer Part No.
PANDUIT CORP. PSL-HD3
PSL-1A
Master Lock 420
421
XN Series Emergency Stop Switches ø30
13
Operating Instructions
Removing the Contact Block
Grab
Grab
Latch
Bayonet Ring (yellow)
Pull
Turn counterclockwise
First unlock the operator button.
Grab the yellow bayonet ring
and pull back the bayonet ring
until the latch pin clicks , then
turn the contact block counter-
clockwise and pull out .
Notes for removing the contact block
1. Do not attempt to remove the contact block while the
oper ator is latched, otherwise the switch may be dam-
aged.
2. When the contact block is removed, the monitor contact
(NO contact) is closed.
3. While removing the contact block, do not use excessive
force, otherwise the switch may be damaged.
4. An LED lamp is built into the contact block for illumi-
nated pushbuttons. When removing the contact block,
pull the contact block straight to prevent damage to the
LED lamp. If excessive force is used, the LED lamp may
be damaged and fail to light.
Panel Mounting
Remove the locking ring from
the operator and check that
the rubber gasket is in place.
Insert the operator from
panel front into the panel
hole. Face the side without
thread on the operator with
TOP marking upward, and
tighten the lock ing ring using ring wrench XN9Z-T1 or
TWST-T1 to a torque of 2.5 N·m maximum.
When using a nameplate
When using a nameplate HNAV-, break
the projection from the nameplate using
pliers.
Installing the Contact Block
First unlock the operator but-
ton.
Align the small marking on
the edge of the operator with
the small marking on the
yellow bayonet ring. Hold the
contact block, not the bayonet
ring. Press the contact block
onto the operator and turn the
contact block clockwise until
the bayo net ring clicks.
Notes for installing the contact block
1. Do not attempt to install the contact block when the
opera tor is latched, otherwise the switch may be dam-
aged.
2. Make sure that the bayonet ring is in the locked position.
Installing & Removing Terminal Covers
To remove the terminal
cover, pull out the two
latches on the top side of the
terminal cover. Do not exert
excessive force to the latch-
es, otherwise the latches
may break.
IP20 Fingersafe Terminal
Cover XW9Z-VL2MF
To install the IP20 ngersafe
terminal
cover, align the TOP marking on
the cover with the TOP marking
on the contact block, and press
the cover toward the contact
block.
Notes:
1. Once installed, the XW9Z-VL2MF
cannot be removed.
2. With the XW9Z-VL2MF installed,
crimping terminals cannot be used.
Use solid wires.
3. The XW9Z-VL2MF cannot be in-
stalled after wiring.
4. Make sure that the XW9Z-VL2MF is
securely installed. IP20 cannot be
achieved when installed loosely, and
electric shocks may occur.
Notes for Operation
When using the XN emergency stop switches in safety-
related part of a control system, observe safety standards
and regulations of the relevant country or region. Also be
sure to perform a risk assessment before operation.
Wiring
Tighten the M3 terminal screws to a torque of 0.6 to 1.0
N·m.
Contact Bounce
When the button is reset by pulling or turning, the NC main
contacts will bounce. When pressing the button, the NO
monitor contacts will bounce.
When designing a control circuit, take the contact bounce
time into consideration (reference value: 20 ms).
LED Illuminated Switches
An LED lamp is built into the contact block and cannot be
replaced.
Handling
Do not expose the switch to excessive shocks and vibra-
tions, for example by operating the switch with tools.
Other wise the switch may be deformed or damaged, caus-
ing malfunction or operation failure.
XN
Projection
Marking
Marking
Push TOP Marking
Turn clockwise
(Press)
TOP Marking
TOP Marking
(Pull)
TOP Marking
TOP Marking
Projections
Place the projections
on the contact block.
TOP Markings
Press the
terminal cover
Projections Slots
Rubber Gasket Operator without
thread
TOP Marking
Anti-rotation
Projection Locking Ring
14
Emergency Stop Switches (Unibody) Specifications
Standards
Applicable Standards Mark File No. or Organization
UL508
CSA C22.2 No. 14 UL Listing File No. E55996
EN60947-5-5
TÜV SÜD
EU Low Voltage Directive
GB14048.5 CCC No. 2013010305610376
Contact Ratings
Rated Insulation Voltage (Ui) 250V
Rated Thermal Current (Ith) 10A
Rated Operational Voltage (Ue) 24V 110V 220V
Rated Op-
erational
Current
AC
50/60
Hz
Resistive Load (AC-12)
6A 3A 3A
Inductive Load (AC-15)
6A 3A 3A
DC
Resistive Load (DC-12)
6A 2A 1A
Inductive Load (DC-13)
1.5A 0.3A 0.15A
Note: The operational current represents the classication by
making and breaking currents (IEC 60947-5-1).
Minimum applicable load (reference value): 3V AC/DC,
5 mA (Applicable range may vary with operating condi-
tions and load types.)
LED Lamp Ratings
Rated Operating
Voltage of Unit
LED Lamp
Part No. Rated Voltage Rated Current
24V AC/DC LSTD-2R 24V AC/DC ±10% 10 mA
Specifications
Operating
Temperature –25 to +60°C (no freezing)
Illuminated units: –25 to +55°C
Storage Temperature –40 to +80°C
Operating Humidity 45 to 85% RH (no condensation)
Operating Force 50N
Minimum Force
Required for Direct
Opening Action 5.5 mm
Maximum Operator
Stroke 10 mm
Contact Resistance 50 mΩ maximum (initial value)
Insulation Resistance 100 MΩ minimum (500V DC megger)
Dielectric Strength Between live and dead metal parts
Contacts: 2,500V AC, 1 minute
Illuminated parts: 1,000V AC, 1 minute
Vibration
Resistance
Damage limits: 30 Hz, amplitude 1.5 mm
Operating extremes: 5 to 55 Hz, amplitude 0.5
mm
Shock Resistance Damage limits: 1,000 m/s2
Operating extremes: 100 m/s2
Operating Frequency 900 operations/h
Life Mechanical: 250,000 operations minimum
Electrical: 100,000 operations minimum
Degree of Protection IP65
Terminal Style M3.5 screw
Weight (approx.) 58g (HN1E-BV402R)
65g (HN1E-LV402Q4R)
Pushlock Turn Reset Switches (Unibody)
Shape Contact Part No. Button Color
1NO-1NC HN1E-BV411R
Red only
2NC HN1E-BV402R
•When pressed, the button is held depressed. The button is released by turning clockwise.
•Terminal cover HW-VL7 is supplied with the switch.
Illuminated Pushlock Turn Reset Switches (Unibody)
Shape Lamp Contact Part No. Lens Color
Without Lamp
1NO-1NC HN1E-LV411Q0R
Red only
2NC HN1E-LV402Q0R
•When pressed, the button is held depressed. The button is released by turning clockwise.
•Terminal cover HW-VL7 is supplied with the switch.
Maintenance Parts
Name Part No. Ordering No. Package Quantity
Terminal Cover for HW1E HW-VL7 HW-VL7PN10 10
HN Series Emergency Stop Switches
ø30
HN Series Emergency Stop Switches ø30
15
Dimensions Panel Cut-Out
HN1E-LV4
Accessory
Shape Material Part No. Package
Quantity Remarks
Ring Wrench
Metal
(zinc-
plated) TWST-T1 1
•Used for tightening the locking nut.
•Tighten the locking nut to a torque
of 2.0 to 2.5 N·m.
Ring Wrench
Brass XN9Z-T1 1
•Used to tighten the locking ring when installing the XN emer-
gency stop switch onto a panel.
Nameplates (for ø30 Emergency Stop Switches)
Shape Part No. Legend Package
Quantity Remarks
HNAV-0 (blank)
1
1.0
1.5
ø60
ø30
Background: Yellow
Legend: Black
Applicable panel thickness:
0.8 to 4.5 mm
Material: Polyamide
Legend “EMERGENCY STOP” is
indicated outside a ø44mm circle.
HNAV-27
EMERGENCY
STOP
Terminal Arrangement
(Bottom View)
TOP Marking Side
Locking Ring
63
61
23.5
32
ø40
M3.5 Terminal
Screw Gasket
0.5
Panel Thickness 0.8 to 6
R0.8 max.
33
0
+0.2
4.8
0
+0.5
ø30.5
HN1E-BV4
LAMP
X1
X2
0.5
63
61
23.5
32
M3.5 Terminal
Screw
M3.5 Terminal
Screw
Gasket Panel Thickness 0.8 to 6
ø40
Locking Ring
Lamp Terminal
Terminal Arrangement
(Bottom View)
TOP Marking Side
All dimensions in mm.
49.5
52
20.5
23.777
90
ø38
HN
16
ø30 Series Switches & Pilot Lights
Heavy duty switches & pilot lights offer both variety and reliability
Endures harsh environments
•Degree of protection: IP65
•UL, CSA approved, and EN compliant.
Applicable Standards Mark File No. or Organization
UL 508 UL Listing
File No. E68961
CSA C22.2 No.14 CSA File No. LR21451
EN60947-5-1 EU Low Voltage Directive
GB14048.5 CCC No. 200501030514658
Specifications and Ratings
Contact Ratings
Pushbuttons
Illuminated Pushbuttons
Selector Switches
Illuminated Selector Switches
Selector Pushbuttons
Contact Block BS/BST (ø30 series)
Rated Insulation Voltage 600V
Rated Continuous Current 10A
Contact Ratings by Utilization Category
IEC 60947-5-1 AC-15 (A600)
DC-13 (P600)
Characteristics
Contact Ratings by Utilization Category
Operational Voltage 24V 48V 50V 110V 220V 440V
Operational
Current
AC
50/60 Hz
AC-12 Control of resistive loads and solid state loads 10A 10A 10A 6A 2A
AC-15 Control of electromagnetic loads (> 72 VA) 10A 7A 5A 3A 1A
DC DC-12 Control of resistive loads and solid state loads 10A 5A 2.2A 1.1A
DC-13 Control of electromagnets 5A 2A 1.1A 0.6A
Note: The operational current represents the classication by making and breaking currents (IEC 60947-5-1).
Minimum applicable load: 3V AC/DC, 5 mA (applicable range may vary with operating conditions and load types)
For mono-levers and cam switches, see pages 47 and 50.
BS (BST) Contact Block
•Durable nylon 66 housing has a high resistance against alkalis.
•Silver contacts. Gold contact (gold-plated silver) also available.
•Up to four blocks in two layers can be mounted onto each operator.
Contact Blocks
Contact
Single-pole Contact Block
1NO 1NC 1EM (early make) 1LB (late break)
Part
No.
BS BS010E BS001E BS010SE BS001SE
BST BST010 BST001 BST010S BST001S
Push Rod Green Red Black White
BST contact blocks are used for the following switches and are not
interchangeable with BS contact blocks.
(The BS housing is dark gray and the BST housing is light gray.)
•Pushlock turn reset and push turn lock switches
•LED illuminated pushbuttons
•LED illuminated selector switches
•All models of diecast zinc housing swiches & pilot lights
Push Rod
M3.5 Terminal Screw
Inspection
Window
Interlock-
ing Groove
Mounting
Screw
17
ø30 Series Switches & Pilot Lights ø30
LED Illuminated Unit Specifications
Unit Color Code Input Operating Voltage LED Lamp
Lamp Base Part No. Voltage
Pilot Light
Illuminated Pushbutton
Illuminated Selector Switch
A: amber
G: green
PW: pure white
R: red
S: blue
W: white
Y: yellow
Full Voltage
6V AC/DC
BA9S/13
LSTD-66V AC/DC ±10%
12V AC/DC LSTD-112V AC/DC ±10%
24V AC/DC LSTD-224V AC/DC ±10%
Transformer
100/110V AC
120V AC
200/220V AC
240V AC
380V AC
400/440V AC
(50/60 Hz)
BA9S/13 LSTD-66V AC/DC ±10%
DC-DC Converter 110V DC BA9S/13 LSTD-66V AC/DC ±10%
Note: Use a pure white (PW) LED for yellow (Y) illumination.
LED Lamp Ratings (LSTD)
Part No. LSTD-6LSTD-1LSTD-2
Lamp Base BA9S/13
Rated Voltage 6V AC/DC 12V AC/DC 24V AC/DC
Voltage Range 6V AC/DC ±10% 12V AC/DC ±10% 24V AC/DC ±10%
Current
Draw
AC 8 mA 11 mA 11 mA
DC A, R, W: 7 mA
G, PW, S: 5.5 mA 10 mA 10 mA
Color Code A (amber), G (green), PW (pure white), R (red), S (blue), W (white)
Lamp Base Color Same as illumination color
Voltage Marking Die stamped on the base
Life (reference value) Approx. 50,000 hours
(The luminance is reduced to 50% the initial intensity when used on complete
DC.)
Internal Circuit
LED Chip
Resistor
Zener Diode
Protection Diode
X1
X
2
Note: Use a pure white (PW) LED for yellow (Y) illumination.
ø30
18
ø30 ø30 Series Switches & Pilot Lights
Specifications
Operating Temperature –25 to +50°C (no freezing)
Storage Temperature –40 to +80°C (no freezing)
Operating Humidity 45 to 85% RH (no condensation)
Contact Resistance 50 mΩ maximum (initial value)
Insulation Resistance 100 MΩ minimum (500V DC megger)
Dielectric Strength Between live and dead metal parts: 2,500V AC, 1 minute
(Full voltage and pilot lights: 2,000V AC, 1 minute)
Vibration Resistance Operating extremes: 5 to 55 Hz, amplitude 0.5 mm
Shock Resistance Damage limits: 1,000 m/s2
Operating extremes: 100 m/s2
Mechanical Life
(minimum operations)
Pushbuttons
Momentary: 5,000,000
Maintained: 500,000
Illuminated pushbuttons
Momentary: 2,500,000
Maintained: 500,000
Selector switches: 500,000
Key selector switches: 500,000
Illuminated selector switches: 500,000
Selector pushbuttons: 250,000
Mono-lever switches: 500,000
(Interlocking): 250,000
Pushlock turn reset 500,000
Mushroom push-pull switch
Two contact blocks: 500,000
Four contact blocks: 200,000
Electrical Life
(minimum operations)
Pushbuttons: 500,000
1
Illuminated pushbuttons: 500,000 1
Selector switches: 500,000 2
Key selector switches: 500,000 2
Illuminated selector switches: 500,000 2
Selector pushbuttons: 250,000 2
Mono-lever switches: 500,000 3
(Interlocking): 250,000 3
1Switching frequency 1,800 operations/h, duty ratio 40% 4
2Switching frequency 1,200 operations/h, duty ratio 40%
3Switching frequency 900 operations/h, duty ratio 40%
4 Switching frequency 900 operations/h for square twin or twin main-
tained
Degree of Protection
Part No. Unit IEC 60529
A∗∗∗∗
Pushbuttons, pilot lights, illuminated pushbuttons, selector switches, selector
pushbuttons, mono-lever switches, and cam switches (ACSNO/ACSSO)
IP65
Illuminated selector switches, key pushbuttons, key reset pushbuttons, key cam
switches, and key selector switches IP54
U∗∗∗∗ Square pushbuttons, square pilot lights, and cam switches (UC) IP40
Note: (3S) of NEMA ICS 6-110 applies to the pilot lights with round lens.
Mounting Hole Layout
∗The minimum mounting centers are applicable to switches with
one layer of contact blocks (two contact blocks). When two layers
of contact blocks (four contact blocks) are mounted, determine
the minimum mounting centers in consideration of convenience
for wiring.
•Mushroom with shroud: 50 mm minimum
•Jumbo mushroom: 67 mm minimum
•Jumbo mushroom with shroud: 76 mm minimum
•Square twin: 55 mm minimum
•Selector switch with lever: 50 mm minimum
The 4.8 mm recess is for preventing rotation and is not neces-
sary when the nameplate or anti-rotation ring is not used.
R0.8 max.
Square Unit: 55
0
+0.5
0
+0.5
+0.2
0
50
Round Unit: 42
33
ø30.5
4.8
R0.8 max.
0
0
+0.5
0
+0.5
+0.2
50
ø30.5
33
4.8
(Twin Maintained)
Note: For mounting hole layout of pushbuttons, mono-lever switches, and cam switches, see each section.
19
ø30 Series Switches & Pilot Lights (Ordering Information) ø30
Ordering Information
Standard Units
•Specify an operator or Lens/LED Color Code in the Part
No.
•Black, green, and red buttons are included with ush
push buttons.
•Terminal covers, nameplates, and accessories are or-
dered separately.
Terminal Cover
•When a terminal cover is required, order an applicable
terminal cover referring to page 59.
ø30 Series Pushbuttons
ABN2
11 R - MAU
Optional contact
MAU: Gold-plated silver contact
Button color code
Contact conguration
10: 1NO 01: 1NC
11: 1NO-1NC 20: 2NO
02: 2NC 22: 2NO-2NC
40: 4NO 04: 4NC
13: 1NO-3NC 31: 3NO-1NC
30: 3NO 03: 3NC
12: 1NO-2NC 21: 2NO-1NC
Note:
•Mushroom pull ATN23 can have a maximum of two contact
blocks.
•
Mushroom push-pull return ATN22 cannot have only NO or only
NC contacts.
•No other contact congurations are available for square twin
UWQN1 than those specied in this catalog.
ø30 Series Pilot Lights
APN1
116 D R
Note:
•LED lamps cannot be used on 480V AC transformers.
Lens/LED Color Code
Operating voltage code
ø30 Series Illuminated Pushbuttons
ALFN2
126 13 D N R - MAU
Note:
•Illuminated pushbuttons cannot have an odd number of contact
blocks, such as 1NO, 1NC, 3NO, 2NO-1NC, 1NO-2NC, and 3NC.
Optional contact
MAU: Gold-plated silver contact
Lens/LED Color Code
Contact conguration
11: 1NO-1NC 20: 2NO
02: 2NC 31: 3NO-1NC
22: 2NO-2NC 13: 1NO-3NC
40: 4NO 04: 4NC
Operating voltage code
The Part No. development charts shown below can be used to specify switches and pilot lights other than those listed on
the following pages. Gold-plated silver contacts are also available.
ø30
20
ø30 ø30 Series Switches & Pilot Lights (Ordering Information)
ø30 Series Selector Switch
ø30 Series Key Selector Switch
ø30 Series Illuminated Selector Switch
ASN
2 L 11 - MAU
Optional contact
MAU: Gold-plated silver contact
Contact conguration
Operator
(blank): Knob
L: Lever
Operator position code
ASN
2 K 11 D - MAU
Optional contact
MAU: Gold-plated silver contact
Key removable position code
2-position
•Maintained
(blank): Removable in all positions
B: Removable in left only
C: Removable in right only
•Spring return from right
(blank): Removable in left only
•Spring return from left
(blank): Removable in right only
3-position
•Maintained
(blank): Removable in all positions
B: Removable in left and center
C: Removable in right and center
D: Removable in center only
E: Removable in right and left
G: Removable in left only
H: Removable in right only
•Spring return from right
(blank): Removable in left and center
D: Removable in center only
G: Removable in left only
•Spring return from left
(blank): Removable in right and center
D: Removable in center only
H: Removable in right only
•Spring return two-way
(blank): Removable in center only
Contact conguration
Operator position code
Note:
•The key cannot be removed in the return position.
ASLN
2 16 22 D N R - MAU
Optional contact
MAU: Gold-plated silver contact
Lens/LED Color Code
Contact conguration
Operating voltage code
Number of positions
21
ø30 Series Pushbuttons ø30
Flush / Extended / Extended w/Half Shroud / Extended w/Full Shroud Pushbuttons
Package Quantity: 1
Shape Operation Contact Part No. Button Color
Code Dimensions (mm)
Flush
ABN1
Momentary
1NO ABN110
Black (B), green
(G), and red (R)
buttons are sup-
plied with each
unit.
Specify S, W, or
Y when a blue,
white, or yellow
button is required.
M3.5 Terminal Screw
623
46 (1 or
2 blocks)
69 (3 or 4 blocks)
9
Panel Thickness 0.8 to 7.5
ø35
36
40
1NC ABN101
1NO-1NC ABN111
2NO ABN120
2NC ABN102
2NO-2NC ABN122
Flush
AON1
Maintained
1NO AON110
M3.5 Terminal Screw
623
9
Panel Thickness 0.8 to 7.5
ø35
36
40
68 (1 to 2 blocks)
91 (3 to 4 blocks)
1NC AON101
1NO-1NC AON111
2NO AON120
2NC AON102
2NO-2NC AON122
Extended
ABN2
Momentary
1NO ABN210
Specify a but-
ton color code in
place of in the
Part No.
B: black
G: green
R: red
S: blue
W: white
Y: yellow
M3.5 Terminal Screw
623
46 (1 or
2 blocks)
69 (3 or 4 blocks)
9
Panel Thickness 0.8 to 7.5
ø35
36
40
ø25
15.5
1NC ABN201
1NO-1NC ABN211
2NO ABN220
2NC ABN202
2NO-2NC ABN222
Extended
AON2
Maintained
1NO AON210
M3.5 Terminal Screw
623
9
Panel Thickness 0.8 to 7.5
ø35
36
40
ø25
15.5
68 (1 to 2 blocks)
91 (3 to 4 blocks)
1NC AON201
1NO-1NC AON211
2NO AON220
2NC AON202
2NO-2NC AON222
Extended with Half Shroud
ABN2G
Momentary
1NO ABN2G10M3.5 Terminal Screw
623
ø35
40
ø25
Panel Thickness 0.8 to 4
20.5
ø27
42 (1 or
2 blocks)
65 (3 or 4 blocks)
36
1NC ABN2G01
1NO-1NC ABN2G11
2NO ABN2G20
2NC ABN2G02
2NO-2NC ABN2G22
Extended with Half Shroud
AON2G
Maintained
1NO AON2G10
M3.5 Terminal Screw
623
ø35
40
ø25
Panel Thickness 0.8 to 4
20.5
ø27
36
64 (1 or 2 blocks)
87 (3 or 4 blocks)
1NC AON2G01
1NO-1NC AON2G11
2NO AON2G20
2NC AON2G02
2NO-2NC AON2G22
Extended with Full Shroud
ABN2F
Momentary
1NO ABN2F10
M3.5 Terminal Screw
623
ø35
40
ø25
Panel Thickness 0.8 to 7.5
46 (1 or
2 blocks)
69 (3 or 4 blocks)
17
ø28.5
36
1NC ABN2F01
1NO-1NC ABN2F11
2NO ABN2F20
2NC ABN2F02
2NO-2NC ABN2F22
Extended with Full Shroud
AON2F
Maintained
1NO AON2F10
M3.5 Terminal Screw
623
ø35
40
ø25
Panel Thickness 0.8 to 7.5
17
ø28.5
36
68 (1 or 2 blocks)
91 (3 or 4 blocks)
1NC AON2F01
1NO-1NC AON2F11
2NO AON2F20
2NC AON2F02
2NO-2NC AON2F22
•Round bezel and shroud (metal): Chrome-plated
•Other contact congurations and gold-plated silver contacts are also available. See page 19.
(nameplate sold
separately)
(nameplate sold
separately)
(nameplate sold
separately)
(nameplate sold
separately)
(nameplate sold
separately)
(nameplate sold
separately)
(nameplate sold
separately)
(nameplate sold
separately)
ø30
22
ø30 ø30 Series Pushbuttons
Mushroom / Jumbo Mushroom / Square Flush / Square Extended Pushbuttons
Package Quantity: 1
Shape Operation Contact Part No. Button Color
Code Dimensions (mm)
Mushroom
ABN3
Momentary
1NO ABN310
B: black
G: green
R: red
S: blue
W: white
Y: yellow
M3.5 Terminal Screw
623 40
Panel Thickness 0.8 to 7.5
46 (1 or
2 blocks)
69 (3 or 4 blocks)
36
21
ø40
1NC ABN301
1NO-1NC ABN311
2NO ABN320
2NC ABN302
2NO-2NC ABN322
Mushroom
AON3
Maintained
1NO AON310M3.5 Terminal Screw
623 40
Panel Thickness 0.8 to 7.5
36
68 (1 or 2 blocks)
91 (3 or 4 blocks)21
ø40
1NC AON301
1NO-1NC AON311
2NO AON320
2NC AON302
2NO-2NC AON322
Mushroom with Full Shroud
ABN3G
Momentary
1NO ABN3G10M3.5 Terminal Screw
623
Panel Thickness 0.8 to 6.5
44 (1 or
2 blocks)
67 (3 or 4 blocks)
23
ø48
1NC ABN3G01
1NO-1NC ABN3G11
2NO ABN3G20
2NC ABN3G02
2NO-2NC ABN3G22
Palm Mushroom
ABN4
Momentary
1NO ABN410
B: black
G: green
R: red
M3.5 Terminal Screw
623
46 (1 or
2 blocks)
69 (3 or 4 blocks)
Panel Thickness 0.8 to 7.5
35
ø74
1NC ABN401
1NO-1NC ABN411
2NO ABN420
2NC ABN402
2NO-2NC ABN422
Jumbo Mushroom with
Shallow Shroud
ABN4G
Momentary
1NO ABN4G10M3.5 Terminal Screw
623
Panel Thickness 0.8 to 7.5
ø75
46 (1 or
2 blocks)
69 (3 or 4 blocks)
ø65
28
1NC ABN4G01
1NO-1NC ABN4G11
2NO ABN4G20
2NC ABN4G02
2NO-2NC ABN4G22
Jumbo Mushroom with Deep
Shroud
ABN4F
Momentary
1NO ABN4F10
M3.5 Terminal Screw
623
Panel Thickness 0.8 to 7.5
32.5
ø75
46 (1 or
2 blocks)
69 (3 or 4 blocks)
1NC ABN4F01
1NO-1NC ABN4F11
2NO ABN4F20
2NC ABN4F02
2NO-2NC ABN4F22
Square Flush
UBQN1
Momentary
1NO UBQN110
B: black
G: green
R: red
Y: yellow
M3.5 Terminal Screw
623
40
Panel Thickness 0.8 to 5.5
36
14
34
44
52.2
70.5 (3 or 4 blocks)
47.5 (1 or
2 blocks)
1NC UBQN101
1NO-1NC UBQN111
2NO UBQN120
2NC UBQN102
2NO-2NC UBQN122
Square Extended
UBQN2
Momentary
1NO UBQN210
M3.5 Terminal Screw
623
40
Panel Thickness 0.8 to 5.5
36
34
44
47.5 (1 or
2 blocks)
52.2
70.5 (3 or 4 blocks)
20
1NC UBQN201
1NO-1NC UBQN211
2NO UBQN220
2NC UBQN202
2NO-2NC UBQN222
•Specify a button color code in place of in the Part No.
•Round/square bezel and shroud (metal): Chrome-plated
•Other contact congurations and gold-plated silver contacts are also available. See page 19.
(nameplate sold
separately)
(nameplate sold
separately)
23
ø30 Series Pushbuttons ø30
Pushlock Turn Reset / Pushlock Key Reset / Push Turn Lock /
Key ON/OFF Lock / Toggle Lever Pushbuttons
Package Quantity: 1
Shape Contact Part No. Button Color
Code Dimensions (mm)
Mushroom Pushlock Turn Reset
AVN3 1NO AVN310N
R: red
Y: yellow
M3.5 Terminal Screw
40
53 (1 or
2 blocks)
76 (3 or 4 blocks)
ø40
Panel Thickness 0.8 to 7.5
24
36
5.5 23
1NC AVN301N
1NO-1NC AVN311N
2NO AVN320N
2NC AVN302N
2NO-2NC AVN322N
Mushroom Pushlock Key Reset
ABN3K 1NO ABN3K10
B: black
G: green
R: red
Y: yellow
M3.5 Terminal Screw
FREE
623 40
53 (1 or 2
blocks)
76 (3 or 4 blocks)
ø40
Panel Thickness 0.8 to 7.5
24 23.5
36
1NC ABN3K01
1NO-1NC ABN3K11
2NO ABN3K20
2NC ABN3K02
2NO-2NC ABN3K22
Pushlock Push Turn Lock
AJN3 1NO AJN310N
B: black
G: green
R: red
Y: yellow
M3.5 Terminal Screw
K
P
U
S
H
L
O
C
40
53 (1 or 2
blocks)
76 (3 or 4 blocks)
ø40
Panel Thickness 0.8 to 7.5
24
36
5.5 23
1NC AJN301N
1NO-1NC AJN311N
2NO AJN320N
2NC AJN302N
2NO-2NC AJN322N
•Specify a button color code in place of in the Part No.
•Round bezel (metal): Chrome-plated
•Cylinder (metal): Chrome-plated
•Other contact congurations and gold-plated silver contacts are also available. See page 19.
•Pushlock Turn Reset: Button is maintained when pressed and is reset when turned clockwise. Red buttons only.
Note: ø30 pushlock turn reset switches cannot be used as emergency stop switches. When emergency stop switches are required, use
XN or HN series emergency stop switches (ISO 13850 and IEC 60947-5-5 compliant).
•Pushlock Key Reset: Button is maintained when pressed and is reset with a key. Key is removable from both depressed and reset posi-
tions. Two keys are supplied.
Note: ø30 pushlock key reset switches cannot be used as emergency stop switches. When emergency stop switches are required, use
HW series emergency stop switches with a HW9Z-A30 ring adapter (ISO 13850 and IEC 60947-5-5 compliant).
•Push Turn Lock: Button is locked when turned clockwise in the depressed position and is reset when turned counterclockwise.
(nameplate sold
separately)
ø30
24
ø30 ø30 Series Pushbuttons
Pull / Push-Pull / Pin Lock Pushbuttons
Package Quantity: 1
Shape Contact Part No. Button Color
Code Dimensions (mm)
Mushroom Pull
ATN23
1NO ATN2310
B: black
G: green
R: red
Y: yellow
40
36
23
53 (1 or 2 blocks)
32.5
6 stroke
6
38.4
ø40
Panel Thickness 0.8 to 7.5
M3.5 Terminal Screw
1NO-1NC ATN2311
2NO ATN2320
2NC ATN2302
Mushroom Push-Pull
ATN21
1NO-1NC ATN2111
40
ø40
36
623
38.5
53 (1 or 2 blocks)
76 (3 or 4 blocks)
6 stroke
Panel Thickness 0.8 to 7.5
M3.5 Terminal Screw
2NO ATN2120
2NC ATN2102
2NO-2NC ATN2122
ATN22
Mushroom Push-Pull Return
1NO-1NC ATN2211
623
35.5
36
40
ø40
38.4
3 stroke3 stroke
Panel Thickness 0.8 to 7.5
M3.5 Terminal Screw
53 (1 or 2 blocks), 76 (3 or 4 blocks)
2NO-2NC ATN2222
•Specify a button color code in place of in the Part No.
•Round bezel and shroud (metal): Chrome-plated
•Square bezel (metal): Chrome-plated
•Other contact congurations and gold-plated silver contacts are also available. See page 19.
•Pull: Pulling the button operates the contacts, and releasing the button return the contacts. Suitable to prevent unintended operation
when an object touches the pushbutton. Up to 2 contact blocks (1 layer) can be mounted on pull switches.
•Push-Pull: 2-position pushbutton. Pushing or pulling operates the contacts. Button is maintained in both depressed and reset positions.
Note: ø30 push pull switches cannot be used as emergency stop switches. When emergency stop switches are required, use XN series
emergency stop switches (ISO 13850 and IEC 60947-5-5 compliant).
•Push-Pull Return:
3-position pushbutton. Pushing or pulling the button operates the contacts. Button is spring-returned to the center posi-
tion.
(nameplate sold
separately)
(nameplate sold
separately)
(nameplate
sold separately)
Pull Switch
Contact ATN23
Normal Pull
1NO
1NC
1NO-1NC
2NO
2NC
Push-Pull Switch
Contact ATN21
Push Pull
1NO-1NC
2NO
2NC
2NO-2NC
Push-Pull Return Switch
Contact ATN22
Push Normal Pull
1NO-1NC
2NO-2NC
Contact Operation
25
ø30 Series Pushbuttons ø30
Square Twin / Twin Maintained Pushbuttons
Package Quantity: 1
Shape Contact Part No. Button Color Dimensions (mm)
Square Twin (Momentary)
UWQN1 ON OFF
ON: Black
OFF: Red
O N
OFF
M3.5 Terminal Screw
623
Panel Thickness 0.8 to 13
47 (1 or
2 blocks)
70 (3 or 4 blocks)
15.5
53
42
36
1NO 1NO UWQN11010
1NO 1NC UWQN11001
2NO 2NC UWQN12002
Square Twin (Maintained)
UWQN2 ON OFF
ON: Black
OFF: Red
O N
OFF
M3.5 Terminal Screw
623
Panel Thickness 0.8 to 13
47 (1 block)
70 (2 blocks) 15.5
53
42
36
1NO UWQN21000
1NC UWQN20100
1NO-1NC UWQN21100
2NO UWQN22000
2NC UWQN20200
Flush Twin Maintained
ABBN11 Top Bottom
Black (B), green (G),
and red (R) buttons
are sup plied with
each unit.
0.8 to 7.5
M3.5 Terminal Screw
Panel
Thickness
57
80
40
ø35
50
86
9
1NO ABBN1110
1NC ABBN1101
1NO-1NC ABBN1111
2NO ABBN1120
2NC ABBN1102
2NO-2NC ABBN1122
Mushroom Twin Maintained
(Without buttons)
ABBN33
Top Bottom
M3.5 Terminal Screw
Panel
Thickness
0.8 to 7.5
57
80
40
50
86
ø40
21
1NO ABBN3310
1NC ABBN3301
1NO-1NC ABBN3311
2NO ABBN3320
2NC ABBN3302
2NO-2NC ABBN3322
•Round bezel (metal): Chrome-plated
•Other contact congurations and gold-plated silver contacts are also available. See page 19.
•Square Twin (Momentary): Two independent momentary switches are contained in one unit, each operated by ON or OFF button. With
the ø30 adapter removed from the sleeve, the unit can mount in a ø25.5mm mounting hole for the ø25 series.
•Square Twin (Maintained): The contact operates when ON button is pressed and is maintained in the depressed position. The button is
reset by pressing the OFF button.
•Twin Maintained: The contact operates when the top button is pressed and is maintained in the depressed position. The button is reset
by pressing the bottom button.
Different combinations of ush, extended HW9Z-A30 buttons, and colors are available (ABN1B-,ABN2B-). See page 65.
Mushroom buttons for the ABBN33 are ordered separately. Specify the color code (ABN3B-). See page 65.
(nameplate sold
separately)
(nameplate sold
separately)
(nameplate sold
separately)
(nameplate sold
separately)
ø30
26
ø30 ø30 Series Pilot Lights
Dome Pilot Lights
Package Quantity: 1
Shape Lamp Lamp Receptacle Part No. Lens/LED Color Code Applicable Lamp
Dome
APN1
APNE1
Without Lamp BA9S APN199
C: clear
DNA: amber
DNY: yellow
G: green
O: orange
R: red
S: blue
W: white
See pages 17 for
lamps.
LED BA9S APN1DN
A: amber
G: green
PW: pure white
R: red
S: blue
W: white
Y: yellow
A: amber
G: green
R: red
S: blue
W: white
Y: yellow
Operating Voltage Code
Specify an operating voltage code in place of in the Part No.
Operating Voltage Code Input
66: 6V AC/DC
11: 12V AC/DC
22: 24V AC/DC Full Voltage
16: 100/110V AC
126: 120V AC
26: 200/220V AC
246: 240V AC
386: 380V AC
46: 400/440V AC
Transformer
16D: 110V DC DC-DC Converter
•Specify a Lens/LED Color Code in place of in the Part No.
•Use a pure white (PW) LED for yellow (Y) illumination.
DC-DC converter types are not approved by UL and CSA, and not CE compliant (operating voltage 90 to 140V DC).
Dimensions
M3 Terminal Screw
40
ø35
Panel Thickness 0.8 to 7.5
21.5 23.5
36
M3.5 Terminal Screw
40
ø35
Panel Thickness 0.8 to 7.5
23.5
36
58.5 All dimensions in mm.
Full Voltage
Transformer
DC-DC Converter
27
ø30 Series Pilot Lights ø30
Square / Rectangular (Marking) Pilot Lights
Package Quantity: 1
Shape Lamp Lamp Receptacle Part No. Lens/LED Color Code Applicable Lamp
Square
UPQN3B
Without Lamp BA9S UPQN3B99
DA: amber
DY: yellow
C: clear
G: green
O: orange
R: red
S: blue
W: white
See pages 18 for
lamps.
LED BA9S UPQN3BD
A: amber
G: green
R: red
S: blue
W: white
Y: yellow
Rectangular (Marking)
UPQN4
Without Lamp BA9S UPQN499
DA: amber
DY: yellow
G: green
O: orange
R: red
S: blue
W: white
LED BA9S UPQN4D
A: amber
G: green
R: red
S: blue
W: white
Y: yellow
Operating Voltage Code
Specify an operating voltage code in place of in the Part No.
Operating Voltage Code Input Type
66: 6V AC/DC
11: 12V AC/DC
22: 24V AC/DC
Full Voltage
16: 100/110V AC
126: 120V AC
26: 200/220V AC
246: 240V AC
386: 380V AC
46: 400/440V AC
Transformer
16D: 110V DC DC-DC Converter
•Specify a Lens/LED Color Code in place of in the Part No.
•Use a pure white (PW) LED for yellow (Y) illumination.
•On the rectangular marking pilot light, a clear lens and a color marking plate are used for white illumination.
Marking plate: 24 × 30 mm, 2 mm thick
DC-DC converter types are not approved by UL and CSA, and not CE compliant (operating voltage 90 to 140V DC).
ø30
28
ø30 ø30 Series Pilot Lights
M3 Terminal
Screw
40
36
34
Panel Thickness 0.8 to 5.5
23 20
52.2
44
M3 Terminal
Screw
40
36
Panel Thickness 0.8 to 4.5
52.2
44
29.5 10.5
34 ¥ 40
M3.5 Terminal
Screw
40
36
34
Panel Thickness 0.8 to 5.5
20
52.2
44
25
60
M3.5 Terminal
Screw
40
36
Panel Thickness 0.8 to 4.5
52.2
44
10.5
34 ¥ 40
66
30 ¥ 36
Square Full Voltage
UPQN3B
Rectangular Full Voltage
UPQN4
Square Transformer
Square DC-DC Converter
UPQN3B
Rectangular Transformer
Rectangular DC-DC Converter
UPQN4
All dimensions in mm.
Reector
1. The lamp housing of the square LED illuminated pilot
lights has a built-in reector.
2. Make sure that the reector does not fall off when re-
moving the lens or marking plate.
3. When replacing the LED lamp of UPQNE4 (rectangular),
use a lamp holder tool (OR-55).
4. To remove the reector, insert a at screwdriver inside
the groove of the reector and lightly push out.
Panel Mounting
1. Tighten the square ring to the operator and position the
ring correctly.
2. Lightly tighten the screw to secure the pilot light onto the
panel.
Groove
Tighten the screw
lightly so that the panel
does not bend.
Screw
Recommended
tightening torque: 0.15 N·m
Dimensions
29
ø30 Series Illuminated Pushbuttons ø30
Round Extended Illuminated Pushbuttons
Package Quantity: 1
Shape Lamp
Receptacle Operation Lamp Contact Part No. Applicable Lamp
Round Extended
ALN2
AOLN2
ALNE2
AOLNE2
BA9S
Momentary
Without Lamp
1NO-1NC ALN29911DN
See pages 17 for
lamps.
2NO ALN29920DN
2NC ALN29902DN
LED
1NO-1NC ALN211DN
2NO ALN220DN
2NC ALN202DN
Maintained
Without Lamp
1NO-1NC AOLN29911DN
2NO AOLN29920DN
2NC AOLN29902DN
LED
1NO-1NC AOLN211DN
2NO AOLN220DN
2NC AOLN202DN
Color Code and Operating Voltage Code
Lens/LED Color Code Operating Voltage Code Input
Specify a Lens/LED Color Code in place of .
A: amber
G: green
PW: pure white
R: red
S: blue
W: white
Y: yellow
Use a pure white (PW) LED for yellow (Y) illumination.
66: 6V AC/DC
11: 12V AC/DC
22: 24V AC/DC Full voltage
16: 100/110V AC
126: 120V AC
26: 200/220V AC
246: 240V AC
386: 380V AC
46: 400/440V AC
Transformer
Dimensions
86 (4 blocks)
63 (2 blocks)
9
23.5
Panel Thickness 0.8 to 7.5
5.5 23
ø35
ø24
M3 Terminal
Screw
M3.5 Terminal
Screw
ø40
40
M3.5 Terminal
Screws
97.5 (2 blocks)
120.5 (4 blocks)
9
23
Panel Thickness 0.8 to 7.5
ø24
ø35
23.5
ø40
40
ALN2/AOLN2
BA9S/Full Voltage
ALN2/AOLN2
BA9S/Transformer
All dimensions in mm.
ø30ø30
30
ø30 ø30 Series Illuminated Pushbuttons
Round Extended with Half Shroud Illuminated Pushbuttons
Package Quantity: 1
Shape Lamp Receptacle Operation Lamp Contact Part No. Applicable Lamp
Round Extended
ALGN2
AOLGN2
ALGNE2
AOLGNE2
BA9S
Momentary
Without Lamp
1NO-1NC ALGN29911DN
See pages 17 for
lamps.
2NO ALGN29920DN
2NC ALGN29902DN
LED
1NO-1NC ALGN211DN
2NO ALGN220DN
2NC ALGN202DN
Maintained
Without Lamp
1NO-1NC AOLGN29911DN
2NO AOLGN29920DN
2NC AOLGN29902DN
LED
1NO-1NC AOLGN211DN
2NO AOLGN220DN
2NC AOLGN202DN
Color Code and Operating Voltage Code
Specify a code in place of or in the Part No.
Lens/LED Color Code Operating Voltage Code Input
Specify a Lens/LED Color Code in place of .
A: amber
G: green
PW: pure white
R: red
S: blue
W: white
Y: yellow
Use a pure white (PW) LED for yellow (Y) illumination.
66: 6V AC/DC
11: 12V AC/DC
22: 24V AC/DC Full voltage
16: 100/110V AC
126: 120V AC
26: 200/220V AC
246: 240V AC
386: 380V AC
46: 400/440V AC
Transformer
Dimensions
M3 Terminal
Screw
M3.5 Terminal Screw
84.5 (4 blocks)
61.5 (2 blocks) 25
Panel Thickness 0.8 to 5.5
5.5 23
ø35
ø29.5
ø40
40
M3.5 Terminal
Screws
96 (2 blocks)
119 (4 blocks)
23
Panel Thickness 0.8 to 5.5
ø29.5
ø35
25
ø40
40
ALFN2/AOLFN2
BA9S/Full Voltage
ALFN2/AOLFN2
BA9S/Transformer
All dimensions in mm.
31
ø30 Series Illuminated Pushbuttons ø30
Color Code and Operating Voltage Code
Specify a code in place of or in the Part No.
Lens/LED Color Code Operating Voltage Code Input
Specify a Lens/LED Color Code in place of .
A: amber
G: green
PW: pure white
R: red
S: blue
W: white
Y: yellow
Use a pure white (PW) LED for yellow (Y) illumination.
66: 6V AC/DC
11: 12V AC/DC
22: 24V AC/DC Full voltage
16: 100/110V AC
126: 120V AC
26: 200/220V AC
246: 240V AC
386: 380V AC
46: 400/440V AC
Transformer
Dimensions
M3 Terminal
Screw
M3.5 Terminal Screw
84.5 (4 blocks)
61.5 (2 blocks) 25
Panel Thickness 0.8 to 5.5
5.5 23
ø35
ø29.5
ø40
40
M3.5 Terminal
Screws
96 (2 blocks)
119 (4 blocks)
23
Panel Thickness 0.8 to 5.5
ø29.5
ø35
25
ø40
40
ALFN2/AOLFN2
BA9S/Full Voltage
ALFN2/AOLFN2
BA9S/Transformer
All dimensions in mm.
Round Extended with Half Shroud Illuminated Pushbuttons
Shape Lamp Receptacle Operation Lamp Contact Part No. Applicable Lamp
Round Extended
ALFN2
AOLFN2
ALFNE2
AOLFNE2
BA9S
Momentary
Without Lamp
1NO-1NC ALFN29911DN
See pages 17 for
lamps.
2NO ALFN29920DN
2NC ALFN29902DN
LED
1NO-1NC ALFN211DN
2NO ALFN220DN
2NC ALFN202DN
Maintained
Without Lamp
1NO-1NC AOLFN29911DN
2NO AOLFN29920DN
2NC AOLFN29902DN
LED
1NO-1NC AOLFN211DN
2NO AOLFN220DN
2NC AOLFN202DN
Package Quantity: 1
ø30ø30
32
ø30 ø30 Series Illuminated Pushbuttons
Package Quantity: 1
Shape Lamp Receptacle Operation Lamp Contact Part No. Applicable Lamp
ø40 Mushroom
ALN3
AOLN3
ALNE3
AOLNE3
BA9S
Momentary
Without Lamp
1NO-1NC ALN39911DN
See pages 17 for
lamps.
2NO ALN39920DN
2NC ALN39902DN
LED
1NO-1NC ALN311DN
2NO ALN320DN
2NC ALN302DN
Maintained
Without Lamp
1NO-1NC AOLN39911DN
2NO AOLN39920DN
2NC AOLN39902DN
LED
1NO-1NC AOLN311DN
2NO AOLN320DN
2NC AOLN302DN
Color Code and Operating Voltage Code
Specify a code in place of or in the Part No.
Lens/LED Color Code Operating Voltage Code Input
Specify a Lens/LED Color Code in place of .
A: amber
G: green
R: red
S: blue
W: white
Y: yellow
Use a pure white (PW) LED for yellow (Y) illumination.
66: 6V AC/DC
11: 12V AC/DC
22: 24V AC/DC Full voltage
16: 100/110V AC
126: 120V AC
26: 200/220V AC
246: 240V AC
386: 380V AC
46: 400/440V AC
Transformer
Dimensions
86 (4 blocks)
63 (2 blocks) 23.5
Panel Thickness 0.8 to 7.5
5.5 23
ø40
M3 Terminal Screw
M3.5 Terminal Screw
36
40
M3.5 Terminal
Screws
97.5 (2 blocks)
120.5 (4 blocks)
23
Panel Thickness 0.8 to 7.5
ø40
23.5
36
40
ALN3/AOLN3
BA9S/Full Voltage
ALN3/AOLN3
BA9S/Transformer
Mushroom (ø40) Illuminated Pushbuttons
33
ø30 Series Illuminated Pushbuttons ø30
Package Quantity: 1
Shape Lamp Receptacle Operation Lamp Contact Part No. Applicable Lamp
ø40 Mushroom
Pushlock Turn Reset
AVLN3
AVLNE3
BA9S Pushlock Turn
Reset
Without Lamp
1NO-1NC AVLN39911DNR
See pages 17 for
lamps.
2NO AVLN39920DNR
2NC AVLN39902DNR
LED
1NO-1NC AVLN311DNR
2NO AVLN320DNR
2NC AVLN302DNR
ø40 Mushroom
Push Turn Lock
AJLN3
BA9S Push Turn Lock
Without Lamp
1NO-1NC AJLN39911DN
2NO AJLN39920DN
2NC AJLN39902DN
LED
1NO-1NC AJLN311DN
2NO AJLN320DN
2NC AJLN302DN
Color Code and Operating Voltage Code
Specify a code in place of or in the Part No.
Lens/LED Color Code Operating Voltage Code Input
Specify a Lens/LED Color Code in place of .
A: amber
G: green
R: red
W: white
Y: yellow
66: 6V AC/DC
11: 12V AC/DC
22: 24V AC/DC Full voltage
16: 100/110V AC
126: 120V AC
26: 200/220V AC
246: 240V AC
386: 380V AC
46: 400/440V AC
Transformer
•Pushlock Turn Reset: Lens is maintained when pressed and is reset when turned clockwise. Red lens only.
Note: AVNL3 and AVNLE3 pushlock turn reset switches cannot be used as emergency stop switches. When emergency stop switches
are required, use XN or HN series emergency stop switches (ISO 13850 and IEC 60947-5-5 compliant).
•Push Turn Lock: Lens is maintained when turned clockwise in the depressed position and is reset when turned counterclockwise.
Dimensions
86 (4 blocks)
63 (2 blocks) 23.5
5.5 23
Panel Thickness
0.8 to 7.5
ø40
M3 Terminal
Screw
M3.5 Terminal
Screw
86 (4 blocks)
63 (2 blocks) 23.5
Panel Thickness
0.8 to 7.5
5.5 23
ø40
M3 Terminal
Screw
M3.5 Terminal
Screw
AVLN3
BA9S/Full Voltage
AVLN3
BA9S/Transformer
AJLN3
BA9S/Full Voltage
P
U
H
S
K
O
L
C
M3.5 Terminal
Screws
97.5 (2 blocks)
120.5 (4 blocks)
23
Panel Thickness 0.8 to 7.5
ø40
36
40
23.5
M3.5 Terminal
Screws
97.5 (2 blocks)
120.5 (4 blocks)
23
Panel Thickness
0.8 to 7.5
ø40
23.5
AJLN3
BA9S/Transformer
All dimensions in mm.
Pushlock Turn Reset/Push Turn Lock Illuminated Pushbuttons
ø30ø30
34
ø30 ø30 Series Selector Switches
ASN Selector Switches (Knob Operator)
Package Quantity: 1
90° 2-position
Contact
Conguration
Contact Block Operator Position Maintained Spring Return
from Right Maintained Spring Return
from Left
Mounting
Position Contact L R
L R LRL R LR
1NO 1NO ASN310 ASN410
2
1NO-1NC 1NO ASN311 ASN411
2NC
2NO 1NO ASN320 ASN420
2NO
2NO-2NC
1NO
ASN322 ASN422
2NC
3NO
4NC
1EM-1LB 1EM ASN37S (Note) ASN47S (Note)
2LB
1NO 1NO ASN3010 ASN4010
2
1NO-1NC 1NO ASN3011 ASN4011
2NC
2NO 1NO ASN3020 ASN4020
2NO
2NO-2NC
1NO
ASN3022 ASN4022
2NC
3NO
4NC
1EM-1LB 1EM ASN307S (Note) ASN407S (Note)
2LB
45° 3-position
Contact
Conguration
Contact Block Operator Position Maintained Spring Return
from Left Maintained Spring Return
from Right
Mounting
Position Contact L C R
C
LR
C
LR
C
LR
C
LR
1NO-1NC 1NO ASN111 ASN211
2NC
2NO-2NC
1NO
ASN122 ASN222
2NC
3NO
4NC
2NO-2NC
1NO
ASN15S ASN25S
2NO
3NC
4NC
2NC 1NC ASN17S ASN27S
2NC
4NC
1NC
ASN18S ASN28S
2NC
3NC
4NC
1NO-1NC 1NO ASN1011 ASN2011
2NC
2NO-2NC
1NO
ASN1022 ASN2022
2NC
3NO
4NC
2NO-2NC
1NO
ASN105S
ASN205S
2NO
3NC
4NC
2NC 1NC
ASN107S
ASN207S
2NC
4NC
1NC
ASN108S
ASN208S
2NC
3NC
4NC
Note: The overlapping time is shorter for left to right than right to left. Take overlapping time into consideration.
•Knob: Black
•Round bezel (metal): Chrome-plated
•Units marked with differ in shape. See page40 for dimensions.
•When a terminal cover is required, order an applicable terminal cover referring to page 59.
•Nameplates are ordered separately.
1
3
2
4ASN
35
ø30 Series Selector Switches ø30
ASN-T Selector Switches (Knob Operator) [Twin Rod Type]
Package Quantity: 1
45° 3-position
Contact
Conguration
Contact Block Operator Position Maintained Spring Return
from Left Maintained Spring Return
from Right
Mounting
Position Contact L C R
C
L R
C
L R
C
L R
C
L R
2NO 1NO ASN120-T ASN220-T
2NO
4NO
1NO
ASN140-T ASN240-T
2NO
3NO
4NO
2NO 1NO ASN2020-T
2NO
4NO
1NO
ASN2040-T
2NO
3NO
4NO
ASN-T are twin-rod units.
•Knob: Black
•Round bezel (metal): Chrome-plated
•When a terminal cover is required, order an applicable terminal cover referring to page 31.
•Nameplates are ordered separately.
ASN-T
1
3
2
4
ø30ø30
36
ø30 ø30 Series Selector Switches
ASNL Selector Switches (Lever Operator)
Package Quantity: 1
90° 2-position
Contact
Conguration
Contact Block Operator Position Maintained Spring Return
from Right Maintained Spring Return
from Left
Mounting
Position Contact L R
L R LRL R LR
1NO 1NO ASN3L10 ASN4L10
2
1NO-1NC 1NO ASN3L11 ASN4L11
2NC
2NO 1NO ASN3L20 ASN4L20
2NO
2NO-2NC
1NO
ASN3L22 ASN4L22
2NC
3NO
4NC
1EM-1LB 1EM ASN3L7S (Note) ASN4L7S (Note)
2LB
1NO 1NO ASN30L10 ASN40L10
2
1NO-1NC 1NO ASN30L11 ASN40L11
2NC
2NO 1NO ASN30L20 ASN40L20
2NO
2NO-2NC
1NO
ASN30L22 ASN40L22
2NC
3NO
4NC
1EM-1LB 1EM ASN30L7S (Note) ASN40L7S (Note)
2LB
45° 3-position
Contact
Conguration
Contact Block Operator Position Maintained Spring Return
from Left Maintained Spring Return
from Right
Mounting
Position Contact L C R
C
L R
C
L R
C
L R
C
L R
1NO-1NC 1NO ASN1L11 ASN2L11
2NC
2NO-2NC
1NO
ASN1L22 ASN2L22
2NC
3NO
4NC
2NO-2NC
1NO
ASN1L5S ASN2L5S
2NO
3NC
4NC
2NC 1NC ASN1L7S ASN2L7S
2NC
4NC
1NC
ASN1L8S ASN2L8S
2NC
3NC
4NC
1NO-1NC 1NO ASN10L11 ASN20L11
2NC
2NO-2NC
1NO
ASN10L22 ASN20L22
2NC
3NO
4NC
2NO-2NC
1NO
ASN10L5S ASN20L5S
2NO
3NC
4NC
2NC 1NC ASN10L7S ASN20L7S
2NC
4NC
1NC
ASN10L8S ASN20L8S
2NC
3NC
4NC
Note: The overlapping time is shorter for left to right than right to left. Take overlapping time into consideration.
•Lever: Black
•Round bezel (metal): Chrome-plated
•Units marked with differ in shape. See page40 for dimensions.
•When a terminal cover is required, order an applicable terminal cover referring to page 59.
•Nameplates are ordered separately.
ASNL
1
3
2
4
37
ø30 Series Selector Switches ø30
ASNL-T Selector Switches (Lever Operator) [Twin Rod Type]
Package Quantity: 1
45° 3-position
Contact
Conguration
Contact Block Operator Position Maintained Spring Return
from Left Maintained Spring Return
from Right
Mounting
Position Contact L C R
C
L R
C
L R
C
L R
C
L R
2NO 1NO ASN1L20-T ASN2L20-T
2NO
4NO
1NO
ASN1L40-T ASN2L40-T
2NO
3NO
4NO
2NO 1NO ASN20L20-T
2NO
4NO
1NO
ASN20L40-T
2NO
3NO
4NO
ASN-T are twin-rod units.
•Lever: Black
•Round bezel (metal): Chrome-plated
•When a terminal cover is required, order an applicable terminal cover referring to page 59.
•Nameplates are ordered separately.
ASNL-T
1
2
4
3
ø30ø30
38
ø30 ø30 Series Selector Switches
ASNK Key Selector Switches
Package Quantity: 1
90° 2-position
Contact
Conguration
Contact Block Operator Position Maintained Spring Return
from Right Maintained Spring Return
from Left
Mounting
Position Contact L R L R LR L R LR
1NO 1NO ASN3K10 ASN4K10
2
1NO-1NC 1NO ASN3K11 ASN4K11
2NC
2NO 1NO ASN3K20 ASN4K20
2NO
2NO-2NC
1NO
ASN3K22 ASN4K22
2NC
3NO
4NC
1EM-1LB 1EM ASN3K7S (Note) ASN4K7S (Note)
2LB
1NO 1NO ASN30K10 ASN40K10
2
1NO-1NC 1NO ASN30K11 ASN40K11
2NC
2NO 1NO ASN30K20 ASN40K20
2NO
2NO-2NC
1NO
ASN30K22 ASN40K22
2NC
3NO
4NC
1EM-1LB 1EM ASN30K7S (Note) ASN40K7S (Note)
2LB
45° 3-position
Contact
Conguration
Contact Block Operator Position Maintained Spring Return
from Left Maintained Spring Return
from Right
Mounting
Position Contact L C R
C
LR
C
LR
C
LR
C
LR
1NO-1NC 1NO ASN1K11 ASN2K11
2NC
2NO-2NC
1NO
ASN1K22 ASN2K22
2NC
3NO
4NC
1NO-1NC
1EM-1LB
1NO
ASN1K5S ASN2K5S
2NC
3EM
4LB
1EM-1LB 1EM ASN1K7S ASN2K7S
2LB
2EM-2LB
1EM
ASN1K8S ASN2K8S
2LB
3EM
4LB
1NO-1NC 1NO ASN10K11 ASN20K11
2NC
2NO-2NC
1NO
ASN10K22 ASN20K22
2NC
3NO
4NC
1NO-1NC
1EM-1LB
1NO
ASN10K5S ASN20K5S
2NC
3EM
4LB
1EM-1LB 1EM ASN10K7S ASN20K7S
2LB
2EM-2LB
1EM
ASN10K8S ASN20K8S
2LB
3EM
4LB
Note: The overlapping time is shorter for left to right than right to left. Take overlapping time into consideration.
•Cylinder: Chrome-plated
•Round bezel (metal): Chrome-plated
•On spring-returned types, the keys can be released only from the maintained position.
On maintained types, the key can be released from every position.
Key retained positions are also available. See page 20.
•Key selector switch is supplied with two standard keys.
Two different keys are available upon request.
•When a terminal cover is required, order an applicable terminal cover referring to page 59.
•Nameplates are ordered separately.
ASNK
1
2
3
4
39
ø30 Series Selector Switches ø30
ASNK-T Key Selector Switches [Twin Rod Type]
Package Quantity: 1
90° 2-position
Contact
Conguration
Contact Block Operator Position Maintained Spring Return
from Right Maintained Spring Return
from Left
Mounting
Position Contact L R L R LRL R LR
1NO 1NO ASN3K10-T ASN4K10-T
2
1NO-1NC 1NO ASN3K11-T ASN4K11-T
2NC
2NO 1NO ASN3K20-T ASN4K20-T
2NO
2NO-2NC
1NO
ASN3K22-T ASN4K22-T
2NC
3NO
4NC
1EM-1LB 1EM ASN3K7S-T ASN4K7S-T
2LB
1NO 1NO ASN40K10-T
2
1NO-1NC 1NO ASN40K11-T
2NC
2NO 1NO ASN40K20-T
2NO
2NO-2NC
1NO
ASN40K22-T
2NC
3NO
4NC
1EM-1LB 1EM ASN40K7S-T
2LB
45° 3-position
Contact
Conguration
Contact Block Operator Position Maintained Spring Return
from Left Maintained Spring Return
from Right
Mounting
Position Contact L C R
C
L R
C
LR
C
L R
C
LR
2NO 1NO ASN1K20-T ASN2K20-T
2NO
4NO
1NO
ASN1K40-T ASN2K40-T
2NO
3NO
4NO
2NO-2NC
1NO
ASN1K5S-T ASN2K5S-T
2NO
3NC
4NC
2NC 1NC ASN1K7S-T ASN2K7S-T
2NC
4NC
1NC
ASN1K8S-T ASN2K8S-T
2NC
3NC
4NC
2NO 1NO ASN20K20-T
2NO
4NO
1NO
ASN20K40-T
2NO
3NO
4NO
2NO-2NC
1NO
ASN20K5S-T
2NO
3NC
4NC
2NC 1NC ASN20K7S-T
2NC
4NC
1NC
ASN20K8S-T
2NC
3NC
4NC
ASN-T are twin-rod units.
•Cylinder: Chrome-plated
•Round bezel (metal): Chrome-plated
•On spring-returned types, the keys can be released only from the maintained position.
On maintained types, the key can be released from every position.
Key retained positions are also available. See page 20.
•Key selector switch is supplied with two standard keys.
Two different keys are available upon request.
•When a terminal cover is required, order an applicable terminal cover referring to page 59.
•Nameplates are ordered separately.
42
3
1
ASNK-T
ø30ø30
40
ø30 ø30 Series Selector Switches
Dimensions
Knob Operator
Lever Operator
Key Selector
40
36
23
54 (1 or 2
blocks)
77 (3 or 4 blocks)
ø35
6
22 22
24.5
M3.5 Terminal Screw
Panel Thickness
0.8 to 7.5
90
°
45°
45°
All dimensions in mm.
M3.5 Terminal Screw
80 (3 or 4 blocks)
57 (1 or 2
blocks)
623
Panel Thickness
0.8 to 7.5
ø35
38
16.5 40
40
45°
45°
Dimensions of key selector switches marked with "-T" in the Part No.
Contact Block Mounting Position and Contact Conguration Chart
40
36
623
54 (1 or 2
blocks)
77 (3 or 4 blocks)
22
ø35
45°
45°
90°
M3.5 Terminal Screw
Panel Thickness
0.8 to 7.5
40
36
623
22
ø35
58 (1 or 2
blocks)
81 (3 or 4 blocks)
45°
45°
M3.5 Terminal Screw
Panel Thickness
0.8 to 7.5
Dimensions of knob operator marked with or "-T" in the Part No.
M3.5 Terminal Screw
40
36
23
54 (1 or 2
blocks)
77 (3 or 4 blocks)
Panel Thickness
0.8 to 7.5
6
27
45°
45°
90°
ø35
25.0
40
36
623
58 (1 or 2
blocks)
81 (3 or 4 blocks)
ø35
25.0
26.5
45°
45°
M3.5 Terminal Screw
Panel Thickness
0.8 to 7.5
Dimensions of lever operator marked with or "-T" in the Part No.
L C R
1NO
2NO
3NC
4NC
Operator
position
RightCenterLeft
42
1
3
41
ø30 Series Selector Switches ø30
ASTN Selector Switches (Knob Operator)
Package Quantity: 1
No. of Positions
ASTN
•Knob operator: Black
•Round bezel (metal): Chrome-plated
90° 2-position
Contact
Congura-
tion
Contact Block Operator Position Maintained Spring Return
from Right
Mounting
Position
Contact
L R L R LR
1NO-1NC 1NO ASTN3211 ASTN4211
2NC
2NO-2NC
1NO
ASTN3222 ASTN4222
2NO
3NC
4NC
45° 3-position
Contact
Congu-
ration
Contact Block Operator Position Maintained Spring Return
from Left Spring Return
from Right Spring Return
Two-way
Mounting
Position
Contact
L C R
C
L R
C
LRC
LRC
LR
2NO 1NO ———ASTN5120
2NO
2NO-2NC
1NO
ASTN1122 ASTN2122 ASTN20122 ASTN5122
2NO
3NC
4NC
2NO-2NC
1NO
ASTN1222 ASTN2222 ASTN20222 ASTN5222
2NO
3NC
4NC
4NO
1NO
ASTN1340
2NO
3NO
4NO
2NO-2NC
1NO
ASTN1422 ASTN20422
2NC
3NC
4NO
2NO 1NO ASTN1520 ASTN20520
2NO
4NO
1NO
ASTN1540 ASTN20540
2NO
3NO
4NO
1NO-1NC 1NC ASTN1611
2NO
2NO-2NC
1NC
ASTN1622
2NO
3NC
4NO
1NO-1NC 1NO ———ASTN5111
2NC
Notes:
1. The operator of the 2-way spring return unit may slightly deviate from the center position.
2. Turn the operator to each position accurately.
40
ø35
27
623
36
M3.5 Terminal Screw
Panel Thickness
0.8 to 7.5
81 (4 blocks)
58 (2 blocks)
90
°
45
°
45°
L C R
1NO
2NO
3NC
4NC
Center RightLeft
Operator
Position
1
2
3
4
Contact Block Mounting Position and
Contact Conguration Chart
Dimensions
ø30ø30
42
ø30 ø30 Series Selector Switches
ASTNL Selector Switches (Lever Operator)
Package Quantity: 1
No. of Positions
ASTNL•Lever operator: Black
•Round bezel (metal): Chrome-plated
90° 2-position
Contact
Congura-
tion
Contact Block Operator Position Maintained Spring Return
from Right
Mounting
Position Contact L R L R LR
1NO-1NC 1NO ASTN32L11 ASTN42L11
2NC
2NO-2NC
1NO
ASTN32L22 ASTN42L22
2NO
3NC
4NC
45° 3-position
Contact
Congura-
tion
Contact Block Operator Position Maintained Spring Return
from Left Spring Return
from Right Spring Return
Two-way
Mounting
Position Contact L C R
C
LR
C
LR
C
L R
C
L R
2NO 1NO ———ASTN51L20
2NO
2NO-2NC
1NO
ASTN11L22 ASTN21L22 ASTN201L22 ASTN51L22
2NO
3NC
4NC
2NO-2NC
1NO
ASTN12L22 ASTN22L22 ASTN202L22 ASTN52L22
2NO
3NC
4NC
4NO
1NO
ASTN13L40
2NO
3NO
4NO
2NO-2NC
1NO
ASTN14L22 ASTN204L22
2NC
3NC
4NO
2NO 1NO ASTN15L20 ASTN205L20
2NO
4NO
1NO
ASTN15L40 ASTN205L40
2NO
3NO
4NO
1NO-1NC 1NC ASTN16L11
2NO
2NO-2NC
1NC
ASTN16L22
2NO
3NC
4NO
1NO-1NC 1NO ———ASTN51L11
2NC
Notes:
1. The operator of the 2-way spring return unit may slightly deviate from the center position.
2. Turn the operator to each position accurately.
L C R
1NO
2NO
3NC
4NC
Center RightLeft
Operator
Position
1
2
3
4
Contact Block Mounting Position and
Contact Conguration Chart
Dimensions
40
623
ø35
29
36
25.0
M3.5 Terminal Screw
Panel Thickness
0.8 to 7.5
58 (1 or 2
blocks)
81 (4 blocks)
90°
45°
45°
43
ø30 Series Selector Switches ø30
ASTNK Key Selector Switches
Package Quantity: 1
No. of Positions90° 2-position
Contact
Congura-
tion
Contact Block Operator Position Maintained Spring Return
from Right
Mounting
Position Contact L R L R LR
1NO-1NC 1NO ASTN32K11 ASTN42K11
2NC
2NO-2NC
1NO
ASTN32K22 ASTN42K22
2NO
3NC
4NC
45° 3-position
Contact
Congura-
tion
Contact Block Operator Position Maintained Spring Return
from Left Spring Return
from Right Spring Return
Two-way
Mounting
Position Contact L C R
C
L R
C
LR
C
L R
C
L R
2NO 1NO ———ASTN51K20
2NO
2NO-2NC
1NO
ASTN11K22 ASTN21K22 ASTN201K22 ASTN51K22
2NO
3NC
4NC
2NO-2NC
1NO
ASTN12K22 ASTN22K22 ASTN202K22 ASTN52K22
2NO
3NC
4NC
4NO
1NO
ASTN13K40
2NO
3NO
4NO
2NO-2NC
1NO
ASTN14K22 ASTN204K22
2NC
3NC
4NO
2NO 1NO ASTN15K20 ASTN205K20
2NO
4NO
1NO
ASTN15K40 ASTN205K40
2NO
3NO
4NO
1NO-1NC 1NC ASTN16K11
2NO
2NO-2NC
1NC
ASTN16K22
2NO
3NC
4NO
1NO-1NC 1NO ———ASTN51K11
2NC
Notes:
1. The operator of the 2-way spring return unit may slightly deviate from the center position.
2. Turn the operator to each position accurately.
80 (4 blocks)
57 (1 or 2
blocks)
623
ø35
38
16.5 40
40
M3.5 Terminal Screw
Panel Thickness
0.8 to 7.5
45°
45°
L C R
1NO
2NO
3NC
4NC
Center RightLeft
Operator
Position
1
2
3
4
Contact Block Mounting Position and
Contact Conguration Chart
Dimensions
ASTN
K•Cylinder: Chrome-plated
•Round bezel (metal): Chrome-plated
•On the spring-returned, the keys can be released
only from the maintained position.
•On the maintained, the key can be released from
every position. Key retained positions are also
available. See page 20.
ø30ø30
44
ø30 ø30 Series Illuminated Selector Switches
ASLN Illuminated Selector Switches
90° 2-position Package Quantity: 1
ASLN (Base BA9S)
Contact
Congu-
ration
Contact Block Operator
Position Lamp
Maintained
L R
Spring Return
from Right
L R
Spring Return
from Left
L R
Mounting
Position
Con-
tact L R
1NO-1NC
1NO Without Lamp ASLN29911NASLN219911NASLN229911N
2NC LED ASLN211DNASLN2111DNASLN2211DN
2NO
1NO Without Lamp ASLN29920NASLN219920NASLN229920N∗
2NO LED ASLN220DNASLN2120DN
ASLN2220DN∗
2NO-2NC
1NO Without Lamp ASLN29922NASLN219922NASLN229922N
2NC
3NO LED ASLN222DNASLN2122DN
ASLN2222DN
4NC
Color Code and Operating Voltage Code
Specify a code in place of or in the Part No.
Lens/LED Color Code Operating Voltage Code Input
A: amber
G: green
R: red
S: blue
W: white
Y: yellow
Use a pure white (PW)
LED for yellow (Y) illumi-
nation.
66: 6V AC/DC
11: 12V AC/DC
22: 24V AC/DC Full voltage
16: 100/110V AC
136: 120V AC
26: 200/220V AC
256: 240V AC
386: 380V AC
46: 400/440V AC
Transformer
On the 2-position selector switches marked with above, the contact operation is reversed as follows.
[Example]
1
2
3
4
L R
1NO
2NC
3NO
4NC
RightLeft
Operator
Position
40
ø40
235.5
28
9
ø35
ø25
M3.5 Terminal Screws
M3 Terminal Screw
63 (2 blocks)
A: 86 (4 blocks)
B: 97.5 (2 blocks), 120.5 (4 blocks)
Panel Thickness
0.8 to 7.5
(including nameplate)
90°
45°
45°
Contact Block Mounting Position
and Contact Conguration Chart
Dimensions
A: Full voltage
B: Transformer
45
ø30 Series Illuminated Selector Switches ø30
ASLN Illuminated Selector Switches
45° 3-position Package Quantity: 1
Contact
Congu-
ration
Contact Block Operator
Position Lamp
Maintained
C
L R
Spring Return
from Right
C
L R
Spring Return
from left
C
L R
Spring Return
Two-way
C
L R
Mounting
Position
Con-
tact L C R
2NO
1NO Without Lamp ASLN39920NASLN319920NASLN329920NASLN339920N
2NO LED ASLN320DNASLN3120DNASLN3220DNASLN3320DN
2NC
1NC Without Lamp ASLN39902NASLN319902NASLN329902NASLN339902N
2NC LED ASLN302DNASLN3102DNASLN3202DNASLN3302DN
2NO-2NC
1NO Without Lamp ASLN39922NASLN319922NASLN329922NASLN339922N
2NO
3NC LED ASLN322DNASLN3122DNASLN3222DNASLN3322DN
4NC
4NO
1NO Without Lamp ASLN39940NASLN319940NASLN329940NASLN339940N
2NO
3NO LED ASLN340DNASLN3140DNASLN3240DNASLN3340DN
4NO
4NC
1NC Without Lamp ASLN39904NASLN319904NASLN329904NASLN339904N
2NC
3NC LED ASLN304DNASLN3104DNASLN3204DNASLN3304DN
4NC
Color Code and Operating Voltage Code
Specify a code in place of or in the Part No.
Lens/LED Color Code Operating Voltage Code Input
A: amber
G: green
R: red
S: blue
W: white
Y: yellow
Use a pure white (PW)
LED for yellow (Y) illumi-
nation.
66: 6V AC/DC
11: 12V AC/DC
22: 24V AC/DC Full voltage
16: 100/110V AC
136: 120V AC
26: 200/220V AC
256: 240V AC
386: 380V AC
46: 400/440V AC
Transformer
1
2
3
4
L C R
1NO
2NO
3NC
4NC
Center RightLeft
Operator
Position
40
ø40
235.5
28
9
ø35
ø25
M3.5 Terminal Screws
M3 Terminal Screw
63 (2 blocks)
A: 86 (4 blocks)
B: 97.5 (2 blocks), 120.5 (4 blocks)
Panel Thickness
0.8 to 7.5
(including nameplate)
90°
45°
45°
Contact Block Mounting Position
and Contact Conguration Chart
Dimensions
A: Full Voltage
B: Transformer
ø30
46
ø30 ø30 Series Selector Pushbuttons
ABN Ring Operator / ABNL Lever Operator Selector Pushbuttons
Package Quantity: 1
Shape Contact
Cogura-
tion
Circuit
Code
Contact
Block
Ring/Lever
Ring
Operator Lever
Operator Button
Color
Code
Pushbutton Part No. Part No.
Mounting
Position Con-
tact Normal Push Normal Push
ABN
M3.5 Terminal Screw
623 41 25 40
ø28
ø35
40
Panel Thickness 0.8 to 7.5
(including nameplate)
M3.5 Terminal Screw
623 41 25 40
ø28
ø35
40
23
Panel Thickness 0.8 to 7.5
(including nameplate)
ABNL
62341 40
ø35
40
26
50
M3.5 Terminal Screw Panel Thickness 0.8 to 7.5
(including nameplate)
41 40
ø35
40
26
50
623 23
M3.5 Terminal Screw
Panel Thickness 0.8 to 7.5
(including nameplate)
Ring Operator (90° 2-position)
Lever Operator (90° 2-position)
1NO-1NC
A1NO
ABN6111ABN6L111
B: black
G: green
R: red
Y: yellow
2NC
I1NC
ABN6411ABN6L411
2NO
G1NO Blocked
ABN9111ABN9L111
2NC
2NO D 1NO
ABN7120
2NO
2NO-2NC
B
1NC
ABN6122ABN6L122
2NC
3NO
4NO
C
1NC
ABN6222ABN6L222
2NC
3NO
4NO
I
1NC
ABN6422ABN6L422
2NC
3NO
4NO
D
1NC
ABN7122ABN7L122
2NC
3NO
4NO
E
1NC
ABN7222ABN7L222
2NC
3NO
4NO
F
1NC
ABN7322ABN7L322
2NC
3NO
4NO
H
1NC
Blocked
ABN9122ABN9L122
2NC
3NO
4NO
•Specify a button color code in place of in the Part No.
•Ring/Lever (metal): Chrome-plated
Notes
1. Circuit Codes A, B, C, and I: When the ring or lever operator is turned, the button is pushed in.
2. Circuit Codes E and F: The right and left NC contact blocks on circuit code E or F may overlap each other while turning the ring or lever
operator. The NO and NC contact blocks on circuit code F may overlap each other while pressing the button.
3. Circuit Codes G and H: The pushbutton does not operate when the ring or lever operator is turned to the left position.
4. When using the selector pushbutton, do not turn the ring or lever operator with the pushbutton depressed. Otherwise, damage or failure
may be caused.
50
50
80
80
1
3
2
4
Contact Block Mounting Position Mounting Hole Layout
Ring Operator
Lever Operator
47
Single lever offers up to four directions of control
Mono-lever switches operate in four directions using a single
lever. Switch contacts are actuated in the direction in which
the lever is pushed, enabling quick and accurate control in
any desired direction. Ideal for machine tools and industrial
machines. The lever action can be maintained or spring-
returned in any combination.
Also available with interlock mechanism to prevent inadvertent
actuation.
Applicable Standards Mark File No. or Organization
UL 508 UL Listing
File No. E68961
CSA C22.2 No.14 CSA File No. LR21451
GB14048.5 CCC
No.2013010305661112
Specifications and Ratings
Contact Ratings
Contact Block BR
Rated Insulation Voltage 600V
Rated Continuous Current 10A
Contact Ratings by Utilization Category
IEC 60947-5-1
AC-15 (A600)
DC-13 (P600)
Characteristics
Contact Ratings by Utilization Category
Operational Voltage 24V 48V 50V 110V 220V 440V
Operational
Current
AC
50/60 Hz
AC-12 Control of resistive loads and solid state loads 10A 10A 10A 6A 2A
AC-15 Control of electromagnetic loads (> 72 VA) 10A 7A 5A 3A 1A
DC DC-12 Control of resistive loads and solid state loads 10A 5A 2.2A 1.1A
DC-13 Control of electromagnets 4A 2A 1.1A 0.6A
Note: The operational current represents the classication by making and breaking currents (IEC 60947-5-1).
Specifications
Contact Conguration
Double-break slow action
Each contact block contains two independent contacts (2NO, 1NO-1NC, 2NC)
Up to four contact blocks can be mounted
Operating Temperature –25 to +50°C (no freezing)
Storage Temperature –35 to +80°C (no freezing)
Operating Humidity 45 to 85% RH (no condensation)
Insulation Resistance 100 MΩ minimum (500V DC megger)
Dielectric Strength Between live and dead parts: 2,500V AC, 1 minute
Mechanical Life 500,000 operations minimum
(Interlocking: 250,000 operations minimum)
Electrical Life
Lever Knob Black
Weight (approx.) 276g (ARN4-1111-20202020)
BR Contact Block
The contact block is made of nylon resin. Each contact
block contains two pairs of double-break silver contacts.
There are three types as shown in the diagram below and
up to four contact blocks can be mounted in any direction.
A wide vari ety of circuits allows diverse combinations of
control.
Control Mechanism
When the operator lever is pushed to about 30° in each
direction from the neutral position, the contact in that
direc tion activates. The lever can operate in two, three, or
four directions, and combinations of maintained or spring-
return from any position are possible.
ARN/ARNS Series Mono-lever Switches
ø30
ø30
48
ø30 ARN/ARNS Series Mono-lever Switches
Mono-lever Switches
Operator Position Lever Action Part No. Dimensions (mm)
ARN (Long Lever)
2-position
(Up-Down)
Maintained ARN2-1010-B
Minimum horizontal/vertical mounting centers: 110
30
M3.5 Terminal
Screw
623
1 block: 47, 2 blocks: 70
3 blocks: 93, 4 blocks: 116
Panel Thickness 0.8 to 6
51
51
ø42
30
ø22
83
Spring return ARN2-2020-B
2-position
(Left-Right)
Maintained ARN2-0101-B
Spring return ARN2-0202-B
4-position
(Up-Down-Left-
Right)
Maintained ARN4-1111-B
Spring return ARN4-2222-B
ARNS (Short Lever)
2-position
(Up-Down)
Maintained ARNS2-1010-B
Minimum horizontal/vertical mounting centers: 70
30
623
63 51
51
ø42
30
M3.5 Terminal
Screw
Panel Thickness
0.8 to 6
ø22
1 block: 47, 2 blocks: 70
3 blocks: 93, 4 blocks: 116
Spring return ARNS2-2020-B
2-position
(Left-Right)
Maintained ARNS2-0101-B
Spring return ARNS2-0202-B
4-position
(Up-Down-Left-
Right)
Maintained ARNS4-1111-B
Spring return ARNS4-2222-B
ARNL (Interlocking)
The operator lever is locked only
in the center position.
2-position
(Up-Down)
Maintained ARNL2-1010-B
Minimum horizontal/vertical mounting centers: 110
30
623
51
51
ø42
30
ø22
83
M3.5 Terminal
Screw Panel Thickness 0.8 to 6
1 block: 47, 2 blocks: 70
3 blocks: 93, 4 blocks: 116
Spring return ARNL2-2020-B
2-position
(Left-Right)
Maintained ARNL2-0101-B
Spring return ARNL2-0202-B
4-position
(Up-Down-Left-
Right)
Maintained ARNL4-1111-B
Spring return ARNL4-2222-B
Specify Contact Conguration from the table below in place of .
Terminal covers are ordered separately.
Ordering Information
When ordering, specify items to according to the following
example.
[Example] ARN 4 – 1012 – 2 0 0 0 0 2 1 1 B
Left
Right
Up Down
Model
No. of
Contact
Blocks
Lever Action Contact
Arrangement
Lever
Knob
Color
ARN
ARNS
ARNL
1: 1 block
2: 2 blocks
3: 3 blocks
4: 4 blocks
Order of Entry:
UpRight
DownLeft
1: Maintained
2: Spring return
0: Blocked
Order of Entry:
UpRight
DownLeft
10: 1NO
01: 1NC
11: 1NO-1NC
20: 2NO
02: 2NC
00: Blocked
B: black
in the center
position.
R0.8 max.
0
+0.5
0
+0.2
+0.5
0
4.8
33
ø30.5
68
0
31
68
31 23 64
Panel Cut-Out Mono-Lever with Terminal Cover
Lever Operator Position
Right
Up
Left
Down
Contact Block Position
Terminal No.
Direction of Lever Operation
Terminal No.
Contact
Block
Type
Lever Operation Mode
1: Maintained
2: Spring return
0: Blocked
1012
1 1 NO 2 BR-2E
3 NC 4
2 5 NO 6 BR-1E
7 NO 8
3 9 NO 10 BR-2E
11 NC 12
413 NC 14 BR-3E
15 NC 16
:Contacts marked with do not operate.
•To calculate the number of contact blocks required, add the number of
NO and NC contacts on each pair of adjoining positions (up + right, right
+ down, down + left, and left + up). The largest of the four sums is the
number of contact blocks required. Up to four contact blocks can be
mounted.
•Specify the same number of contacts for the contact blocks of opposing
corner (up-down, right-left), except for the blocked direction.
•When UL and CSA markings are required on the mono-lever switch,
specify as shown below.
[Example] ARN4-1012-20000211B-
U
49
ARN/ARNS Series Accessories and Replacement Parts ø30
Accessories and Maintenance Parts
Shape Specication Part No. Ordering No. Package Quantity Description
Nameplate MLO
MLO 1
Chrome-plated brass
(matte surface)
MLOPN10 10
Terminal Cover ARN-VL2 ARN-VL2 1
Terminal covers are ordered
separately. When ordering,
specify the Part No. and the
required quantity.
Order 2 pieces for each
contact block.
Contact Block
(BR)
BR-1E BR-1E 1 2NO contact
BR-2E BR-2E 1 1NO-1NC contact
BR-3E BR-3E 1 2NC contact
Bellows ARN-BL ARN-BL 1For ARN/ARNS
(Locking ring not included)
Bellows
(Interlocking) ARNL-BL ARNL-BL 1For ARNL
(Locking ring not included)
Knob ARNB-ARNB-1
Specify a color code in
place of .
B (black), G (green), R (red)
For ARN/ARNS
70
70
ø30.5
ø30
50
71 standard circuits to choose from
•Wide variety of heavy-duty oiltight cam switches
•Operators available up to 12 positions
•Contact blocks rated at 600V, 10A
•Ideal for ammeter/voltmeter applications
•UL listed and CSA approved
Applicable Standards Mark File No. or Organization
GB14048.5
CCC
No.2012010305525956
(ACSNO, ACSNK)
No.2013010305604910
(ACSSO, ACSSK)
No.2013010305600565
(UCSQO, UCSQM)
Specifications and Ratings
Contact Ratings
Rated Insulation Voltage 600V
Rated Continuous Current 10A
Contact Ratings by Utilization Category
IEC 60947-5-1
AC-15 (A600)
DC-13 (P600)
Characteristics
Contact Ratings by Utilization Category
Operational Voltage 24V 110V 220V 440V
Operational
Current
AC
50/60 Hz
AC-12 Control of resistive loads and solid state loads 10A 6A 2A
AC-15 Control of electromagnetic loads (> 72 VA) 5A 3A 1A
DC DC-12 Control of resistive loads and solid state loads 8A 3A 1A 0.4A
DC-13 Control of electromagnets 5A 1.2A 0.45A 0.2A
Note: The operational current represents the classication by making and breaking currents (IEC 60947-5-1).
Specifications
Contact Conguration
Double-break slow action contacts
Two contacts in one deck
Up to 6 decks available (Spring-return: Up to 3 decks)
Operation Maintained Spring return
Angle 30°, 45°, 60°, 90° 45°
Operator Positions 2 to 12 2, 3, 4
Operating Temperature –20 to +50°C (no freezing)
Storage Temperature –40 to +80°C (no freezing)
Operating Humidity 45 to +85% RH (no condensation)
Insulation Resistance 100 MΩ (500V DC megger)
Dielectric Strength 2500V AC, 1 minute (between live and dead parts)
Mechanical Life 1 to 3 decks: 500,000 operations
4 to 6 decks: 200,000 operations
Electrical Life 200,000 operations minimum
Degree of Protection
ACSNO, ACSSO: IP65 (IEC 60529)
ACSNK, ACSSK: IP54 (IEC 60529)
UCS: IP40 (IEC 60529)
Weight (approx.) 319g (ACSNO-663-S2B)
CSB Contact Block
The CSB contact block contains two poles of double-break contacts.
The contacts are operated by a cam designed to perform a required
contact operation. Up to six contact blocks can be mounted on a
maintained-action operator base, and up to three contact blocks on
a spring return operator base.
(except ACSSO and ACSSK)
M3.5 Screw Terminal
CS Series Cam Switches
ø30/ø25
51
CS Series Cam Switches ø30/ø25
Cam Switches
Model Contact
Block Decks Positions Angle Spring
Return Handle
Contact
Arrange-
ment
Name-
plate
ø30 Series ø25 Series
ACSNO ACSSO
Maintained:
1 to 6 decks
Spring return:
1 to 3 decks
Maintained:
2 to 12 positions
Spring return:
2 to 4 positions
Maintained:
30°, 45°, 60°,
90°
Spring return:
45° only
Spring return
from right
Spring return
from left
Spring return
two-way
Y2, S2, P2,
F2, 25S2
(25S2 is for
ACSSO only)
(one speci-
ed handle
supplied)
See page
55 to 57.
See
page
61.
(ordered
sepa-
rately)
ACSNK ACSSK
Maintained:
1 to 6 decks
Spring return:
1 to 3 decks
Maintained:
2 to 8 positions
Spring return:
2 to 4 positions
Maintained:
45°, 90°
Spring return:
45° only
Spring return
from right
Spring return
from left
Spring return
two-way
Two standard
keys are
supplied.
When the H2
key handle
is required,
specify H2.
UCSQO (Enclosed)
Maintained:
1 to 6 decks
Spring return:
1 to 3 decks
Maintained:
2 to 12 positions
Spring return:
2 to 4 positions
Maintained:
30°, 45°, 60°,
90°
Spring return:
45° only
Spring return
from right
Spring return
from left
Spring return
two-way
Y2, S2, F2,
P2
(one speci-
ed handle
supplied)
Type CQ
See
page
60.
UCSQM (Enclosed)
Spring return:
1 to 3 decks
Spring return:
3 positions
Spring return:
45° only
Spring return
two-way
C1007
C1008
C1009
C1010
C1018
C2006
C2007
C2021
See page
55 to 57.
Type
CQM
See
page
60.
For handles and accessories, see page52 and 53.
Dimensions
(Photo: ACSNO with Y2 handle)
Standard Key (2 keys supplied)
H2 Handle Key
58
24
(black)
(Photo: With Y2 handle)
Spring Return 2-way
Left Righ
t
Indicator
Left: Green
Right: Red
M3.5 Terminal
Screw
(P2 Handle)
4-M4 Screw
2912
12N+9
52
770
64
50
Panel Thickness 7.0 max.
31 43
48
N: Number of Contact Blocks
46.4
ACSNO/ACSSO ACSNK/ACSSK Panel Cut-out
47 47
2912
12N+9
52
52
35
30
M3.5 Terminal Screw Panel Thickness 0.8 to 6
* Spring Return: 44
Maintained: 42
N: Number of Contact Blocks
M3.5 Terminal
Screw
(Y2 Handle)
4-M4 Screw
2912
52
12N+9 725
70
64
41
Panel Thickness
7.0 max.
48
46.4
Spring Return: 31
Maintained: 29
N: Number of Contact Blocks
R0.8 max.
ø25.5
(ACSSO/ACSSK)
ø30.5
(ACSNO/ACSNK)
ø5
+0.5
0
0
+0.2
0
+0.5
+0.5
0
4.8
33
4-ø4.5
48
48
ø13
•Minimum horizontal/vertical mounting centers
With P2 handle: 125
With other handles: 70
Panel Cut-out
•Minimum horizontal/vertical mounting centers
With P2 handle: 125
With other handles: 70
UCSQO UCSQM
All dimensions in mm.
* Spring Return: 44
Maintained: 42
N: Number of Contact Blocks
M3.5 Terminal Screw
47 47
52
(S2 Handle)
Panel Thickness 0.8 to 6
29
12
12N+9 30.7
52
50
ø30
52
ø30/ø25 CS Series Cam Switches
Ordering Information
When ordering, specify items through as the designation example below.
Model Contact
Block Decks Positions Angle Spring
Return Handle Key irremovable
position Circuit No.
Decks
Code
Positions Code Angle
Code
Return
Code
ACSNO
ACSNK
ACSSO
ACSSK
UCSQO
UCSQM
1 deck
2 decks
3 decks
4 decks
5 decks
6 decks
1
2
3
4
5
6
2 positions
3 positions
4 positions
5 positions
6 positions
7 positions
8 positions
9 positions
10 positions
11 positions
12 positions
2
3
4
5
6
7
8
9
10
11
12
30°
45°
60°
90°
3
4
6
9
Spring return
from left
Spring return
from right
Spring return
two-way
RO
OR
RR
(Code)
Y2, S2, P2,
F2, H2, 25S2
(Color)
B: Black
See table
below.
For ACSNK/
ACSSK,
specify the
code(s) of
irremovable
position(s)
in numerical
order.
For standard
contact
congurations, use
des ignation code
on pages 55 to 57.
For custom contact
congurations,
use the Custom
Contact
Conguration
Specica tion Sheet
on page 58.
Spring return:
1 to 3 decks
only
Spring return:
2 to 4 positions only
ACSNK/
ACSSK:
45° and 90°
only
Spring return:
45° only
Spring return code
is required only for
spring return.
25S2 is for
ACSSO only.
Standard
ACSNK/
ACSSK: no
specication
required
Designation Example
UCSQO - 2 3 4 RR - S2B - C2006
1. When a special contact conguration is required, specify
the contact conguration using the Custom Contact
Conguration Specication Sheet on page58.
2. A specied handle is attached.
3. Accessories such as nameplates and jumpers are sepa-
rately ordered.
4. The key of the key operated cam switch is removable
at every position unless otherwise specied. The key is
irremovable at return position. The return and irremovable
positions must be specied in Part No. Positions at 180°
from irremovable positions are also irremovable.
Example: 4-positions, spring return from right, irremovable
at positions 3 and 4
ACSNK-344OR-134-C3012
Handle Designation Code
Shape Code Color Applicable
Cam Switch
30
22
19
20
ø25, ø30 Y Handle
Y2
B: black
ACSNO
ACSSO
UCSQO
UCSQM
30
20
30
20
ø25, ø30 S Handle
S2
25.6
20
30
20
ø25, ø25 S Handle
25S2 ACSSO
30
50
40
ø30 S Handle
ø25, ø30 P Handle
P2
ACSNO
ACSSO
UCSQO
UCSQM
30 ø50
40
ø25, ø30 F Handle
F2
18
40
24
Key Handle
H2 ACSNK
ACSSK
Spring Return Operation
Available combinations of operator positions, angles, and return directions are listed in the table below.
Positions 2-position 3-position 4-position 3-position
Return Direction
From Left From Right From Left From Right Two-way From Left From Right Two-way
2
1
1
2
2
31
2
13
2
31
2
3
4
1
3
2
1
4
2
31
➂ ➃ ➄ Codes 24RO 24OR 34RO 34OR 34RR 44RO 44OR 34RR
Applicable Cam Switches
ACSNO, ACSSO, ACSNK, ACSSK, UCSQO UCSQM
Contact Block Decks 1 to 3 decks
Note: Maintained do not require spring return code .
ACSNO - 2 3 4 RR - Y2B - MAU-C2006-ZT2
53
CS Series Accessories and Replacement Parts ø30/ø25
Accessories and Replacement Parts
Shape Material Part No. Ordering No. Package
Quantity Remarks
Jumper
Metal
(copper)
CJ-1 CJ-1PN10 10 For connecting terminals of
adjoining contact blocks
CJ-2 CJ-2PN10 10 For connecting terminals of the
same contact block
Rubber Boot
Nitril
rubber CR-1 CR-1 1
For preventing ingress of dust
into the contact blocks
Not applicable for the UCSQO
and UCSQM
Terminal Cover
Plastic
(PPE)
CS-VL2-13S CS-VL2-13S 1For 1 to 3 decks of contact
blocks
CS-VL2-46S CS-VL2-46S 1For 4 to 6 decks of contact
blocks
Shape Material (Color) Part No. Ordering No. Package Quantity
ø25, ø30
Y Handle 30
22
19
20
Polybutylene terephthalate
(Black) CSH-YB CSH-YB 1
ø25, ø30
S Handle 30
20
30
20
Polybutylene terephthalate
(Black) CSH-SB CSH-SB 1
ø25
S Handle 25.6
20
30
20
Phenol resin (Black) CSH-25SB CSH-25SB 1
ø25, ø30
P Handle 30
50
40
ø30 S Handle
Phenol resin (Black) CSH-PB CSH-PB 1
ø25, ø30
F Handle 30 ø50
40
Bakelite (Black) CSH-FB CSH-FB 1
Key Handle 18
40
24
Phenol resin (Black) CSH-H2B CSH-H2B 1
Spare Keys Metal
(brass nickel-plated) CSH-K301 CSH-K301PN02 2
Handle Shaft
Polyamide CS-HF2C CS-HF2CPN05 5
Handle Screw For Y, ø30 S, and ø25 S handles
M3 × 12 CS-SCW-M3-12 CS-SCW-M3-12PN10 10
Handle Screw
For P and F handles
M3 × 25 CS-SCW-M3-25 CS-SCW-M3-25PN10 10
CJ-1
CJ-2
CS-VL2-13S
Supplied with 2 self-
tapping screws
for mounting
CS-VL2-46S
ø30
54
ø30/ø25 CS Series Instructions
Terminal Cover Dimensions
Installing the Terminal Cover for the CS
series Cam Switches
•
Complete wiring before installing the terminal cover on
the bottom plate of the contact block.
•
The terminal cover has six holes. Of the four round holes
at four corners, use two diagonal pair of holes to install
the terminal cover. Either pair can be used.
•
Insert the attached self-tapping screws into the pair of
holes and tighten the screws to a torque of 0.8 to 1.0
N·m.
•
For 1 through 3 decks of contact blocks, use terminal
cover CS-VL2-13S.
•
For 4 through 6 decks of contact blocks, use terminal
cover CS-VL2-46S.
•
The CS-VL2-46S consists of the CS-VL2-13S and a
termi nal cover for the fourth through sixth decks. Com-
bine the two parts together as shown. Note that once
combined, the two parts cannot be separated.
CS-VL2-13S
Mounting Hole
Mounting Hole
Bottom Plate
Self-tapping Screw (attached)
Insert the screws into
a diagonal pair of holes.
Minimum Mounting Centers for Installing
the Terminal Cover
100 mm min.
(P2 handle: 125 mm)
(P2 handle: 125 mm)
70 mm min.
•Although the minimum mounting centers are 100 mm
hori zontally and 70 mm vertically, determine the mounting
cen ters in consideration of convenience of wiring. For the
P2 handle, the minimum mounting centers are 125 mm
hori zontally and vertically.
CS-VL2-13S
For 4 through 6 decks of contact blocks (CS-VL2-46S)
47
91.4 (CS-VL2-13S)
94.4 (CS-VL2-46S) 7.5
12
9
52
2 40.5
(N: Number of Contact Blocks)
66.1 (CS-VL2-46S)
64.6 (CS-VL2-13S)
34.5 (CS-VL2-46S)
33 (CS-VL2-13S)
12N+9
All dimensions in mm.
Instructions
55
CS Series Instructions ø30/ø25
Standard Contact Configurations
•The following table lists 76 standard contact congura-
tions for easy designation of required cam switch opera-
tion.
•When other contact congurations are required, specify
the number of contact block decks, operator positions,
angles, and contact operation using the Custom Contact
Conguration Specication Sheet on page58.
Symbol Contact Operation
Contacts closed.
Contacts remain closed between two operator
posi tions.
Overlapping Contacts
Contacts of different decks are both closed at one
point while the handle is turned to the next position.
Residual Contacts
When the handle is returned to the center, the con-
tacts remain closed. The contacts are opened when
the handle is turned to the opposite direction.
Listing Order of the Table
The 76 standard contact congurations are listed in the
order of the circuit number.
Same Circuits
Shown in the following examples, circuits of Fig. 1 and Fig.
2 have the same functions. When ordering, examine the
standard contact congurations. Your requirements may
be satised simply by changing external wiring of the stan-
dard contact congurations.
7
3
5
1
7
3
5
1
7
3
5
1
7
3
5
1
8
4
6
2
8
4
6
2
8
4
6
2
8
4
6
2
1 2 31 2 31 2 3 41 2 3 4
Example 1
Fig. 1 Fig. 2
Example 2
Fig. 1 Fig. 2
Terminal Numbers
•The terminal numbers on the contact blocks correspond
with the numbers shown in the chart as shown below.
2 3 4 RR C2006
7
5
3
1
8
6
4
2
1
2
3
Circuit No.
No. of Decks: 2
Position: 3-position
Angle: 45°
Spring Return:
2-way
Terminal No.
Operator Position
The arrow shows the
spring return direction.
7
5
3
1
8
6
4
2
1 2
Operator Position
Terminal No.
Terminal No.
Standard Contact Conguration Chart
1 2 9 C1001 1 2 9 C1002 1 2 4 OR C1003 1 2 4 OR C1004 1 3 4 C1005
3
1
4
2
1 2
3
1
4
2
1 2
3
1
4
2
1 2
3
1
1
4
2
2
3
1
4
2
123
1 3 4 C1006 1 3 4 RR C1007 1 3 4 RR C1008 1 3 4 RR C1009 1 3 4 RR C1010
3
1
4
2
1 2 3
3
1
4
2
1 2 3
3
1
4
2
1 2 3
3
1
4
2
1 2 3
3
1
4
2
1 2 3
1 4 4 C1011 1 2 9 C1013 1 2 9 C1014 1 2 4 OR C1015 1 3 4 C1016
3
1
4
2
1 2 3 4
3
1
4
2
1 2
3
1
4
2
1 2
3
1
4
2
1 2
3
1
4
2
123
1 2 4 C1017 1 3 4 RR C1018 1 2 6 C1019
3
1
4
2
1 2
3
1
4
2
1 2 3
3
1
4
2
1 2
2 2 9 C2001 2 2 9 C2002 2 3 4 C2003 2 3 4 C2004 2 3 4 C2005
7
5
3
1
8
6
4
2
1 2
7
5
3
1
8
6
4
2
1 2
7
5
3
1
8
6
4
2
1 2 3
7
5
3
1
8
6
4
2
1 2 3
7
5
3
1
8
6
4
2
1 2 3
ø30
56
ø30/ø25 CS Series Instructions
2 3 4 RR C2006 2 3 4 RR C2007 2 4 4 C2008 2 4 4 C2009 2 4 9 C2011
7
5
3
1
8
6
4
2
1 2 3
7
5
3
1
8
6
4
2
1 2 3
7
5
3
1
8
6
4
2
1234
7
5
3
1
8
6
4
2
1234
7
5
3
1
8
6
4
2
1234
(O)(R) (S) (T)
2 2 9 C2014 2 2 9 C2015 2 3 4 C2016 2 3 4 C2017
7
5
3
1
8
6
4
2
1 2
7
5
3
1
8
6
4
2
1 2
7
5
3
1
8
6
4
2
123
7
5
3
1
8
6
4
2
1 2 3
2 3 4 C2019 2 3 4 C2020 2 3 4 RR C2021 2 4 4 C2022
7
5
3
1
8
6
4
2
1 2 3
7
5
3
1
8
6
4
2
1 2 3
7
5
3
1
8
6
4
2
1 2 3
7
5
3
1
8
6
4
2
1234
2 5 3 C2027 2 3 6 C2028 2 3 6 C2029
7
5
3
1
8
6
4
2
12345
7
5
3
1
8
6
4
2
1 2 3
7
5
3
1
8
6
4
2
1 2 3
(R)(S) (T)
3 2 9 C3001 3 3 4 C3002 3 5 4 C3003 3 6 4 C3004 3 3 4 C3005
11
9
7
5
3
1
1 2
12
10
8
6
4
2
11
9
7
5
3
1
1 2 3
12
10
8
6
4
2
11
9
7
5
3
1
12
10
8
6
4
2
12345
11
9
7
5
3
1
123456
12
10
8
6
4
2
11
9
7
5
3
1
1 2 3
12
10
8
6
4
2
3 4 9 C3008 3 4 9 C3009 3 2 9 C3010 3 3 4 C3011 3 4 4 C3012
11
9
7
5
3
1
1234
12
10
8
6
4
2
(O)(RS) (ST) (TR)
11
9
7
5
3
1
1 2 3 4
12
10
8
6
4
2
11
9
7
5
3
1
1 2
12
10
8
6
4
2
11
9
7
5
3
1
1 2 3
12
10
8
6
4
2
11
9
7
5
3
1
1 2 3 4
12
10
8
6
4
2
3 6 3 C3013 3 3 6 C3014 3 6 6 C3015 3 5 3 C3016 3 4 4 C3017
11
9
7
5
3
1
12
10
8
6
4
2
123456
11
9
7
5
3
1
1 2 3
12
10
8
6
4
2
11
9
7
5
3
1
12
10
8
6
4
2
123456
11
9
7
5
3
1
12
10
8
6
4
2
12345
11
9
7
5
3
1
12
10
8
6
4
2
1234
3 3 6 C3018 4 4 4 C4001 4 8 4 C4002 4 4 9 C4003
11
9
7
5
3
1
12
10
8
6
4
2
123
15
13
11
9
7
5
3
1
16
14
12
10
8
6
4
2
1234
15
13
11
9
7
5
3
1
16
14
12
10
8
6
4
2
12345678
15
13
11
9
7
5
3
1
16
14
12
10
8
6
4
2
(O)(R) (S) (T)
1234
4 2 4 C4004 4 2 9 C4005 4 2 9 C4006 4 4 9 C4007 4 3 4 C4008
15
13
11
9
7
5
3
1
16
14
12
10
8
6
4
2
12
15
13
11
9
7
5
3
1
16
14
12
10
8
6
4
2
12
15
13
11
9
7
5
3
1
16
14
12
10
8
6
4
2
12
15
13
11
9
7
5
3
1
16
14
12
10
8
6
4
2
1234
(O)(R) (S) (T)
15
13
11
9
7
5
3
1
16
14
12
10
8
6
4
2
123
57
CS Series Instructions ø30/ø25
4 5 4 C4009 5 3 4 C5001 6 4 4 C6001 6 12 3 C6002
15
13
11
9
7
5
3
1
16
14
12
10
8
6
4
2
12345
19
17
15
13
11
9
7
5
3
1
20
18
16
14
12
10
8
6
4
2
123
23
21
19
17
15
13
11
9
7
5
3
1
24
22
20
18
16
14
12
10
8
6
4
2
1234
23
21
19
17
15
13
11
9
7
5
3
1
24
22
20
18
16
14
12
10
8
6
4
2
123456789101112
6 4 9 C6003 6 9 3 C6004 6 6 6 C6005 6 6 4 C6006
23
21
19
17
15
13
11
9
7
5
3
1
24
22
20
18
16
14
12
10
8
6
4
2
1234
(O)(R) (S) (T)
23
21
19
17
15
13
11
9
7
5
3
1
24
22
20
18
16
14
12
10
8
6
4
2
1234
43210
23
21
19
17
15
13
11
9
7
5
3
1
24
22
20
18
16
14
12
10
8
6
4
2
123456
23
21
19
17
15
13
11
9
7
5
3
1
24
22
20
18
16
14
12
10
8
6
4
2
(RS) (ST) (RT) (RE) (SE) (TE)
123456
Application Examples (Voltmeter and Ammeter Circuits)
1 2 6 C1019 (ammeter switching, 1CT circuit) 2 3 6 C2029 (ammeter switching, 2CT circuit) 2 4 9 C2011 (ammeter switching, 2CT circuit)
CT
E
3
1
4
2
A
CS
7
5
3
1
8
6
4
2
RST
RST
CT
CS
A
E
RST
CT
ORST
7
5
3
1
8
6
2
A
CS
E
4
2 4 4 C2022 (voltmeter switching, 3PT circuit) 3 4 9 C3008 (voltmeter switching, 2PT circuit) 3 4 9 C3009 (voltmeter switching, 3PT circuit)
RSTEPT 7
5
3
1
8
6
4
2
3ø-4W
V
CS
O
PT
ST TR
11
9
7
5
3
1
12
10
8
6
4
2
RST
CS
RS
V
RSTE
PT
11
9
7
5
3
1
12
10
8
6
4
2
V
CS
3ø-4W
6 4 9 C6003 (ammeter switching, 3CT circuit) 4 4 9 C4003 (ammeter switching, 3CT circuit) 4 4 9 C4007 (ammeter switching, 2CT circuit)
CT
ORST
23
21
19
17
15
13
11
9
7
5
3
1
24
22
20
18
16
14
12
10
8
6
4
2
RST
A
CS
E
RST
CT
ORST
15
13
11
9
7
5
3
1
16
14
12
10
8
6
4
2
A
CS
E
RST
CT
ORST
15
13
11
9
7
5
3
1
16
14
12
10
8
6
4
2
CS
E
A
ø30
58
ø30/ø25 CS Series Instructions
Custom Contact Configurations Specification Sheet
•
The preceding pages provide 68 standard contact cong-
urations. When other contact congurations are required,
specify the number of contact block decks, operator
posi tions, angles, and contact operation using the Cus-
tom Contact Conguration Specication Sheet shown
below.
•
For available number of contact blocks and operator
posi tions, see the Ordering Information on page52.
1. Specify operator positions
Indicate the operator positions starting at the rst
position. When spring return operation is required, mark
an arrow between two operator positions to indicate the
spring return direction.
Deck 2
7
5
Deck 1
3
1
Angle
Positions 1 2 3 4 5
Spring Return
2. Specify contact operation at each operator position
Indicate the required operation of all contacts at each
operator position using the following symbols.
Symbol Contact Operation
Contacts closed.
Contacts remain closed between two operator
posi tions.
Overlapping Contacts
Contacts of different decks are both closed at
one point while the handle is turned to the next
position.
Overlapping contacts are not available for handle
angles of 30° and 45°.
Residual Contacts
When the handle is returned to the center, the
con tacts remain closed. The contacts are opened
when the handle is turned to the opposite direction.
•One deck of contact block contains two poles of con-
tacts and four terminals. When the handle is made to turn
180° or more, special attention is needed. Since one cam
oper ates the two poles of contacts on opposite positions,
the same contact operation repeats on the other pole of
con tacts when the handle is turned 180°. When different
con tact operation is needed for handle angles of 180° or
more, use another deck of contact block.
CS Series Cam Switch Custom Contact Conguration Specication Sheet
Part No.: Quantity:
Deck Terminal No. Contact Conguration Chart Terminal No.
Deck 6
23 24
21 22
Deck 5
19 20
17 18
Deck 4
15 16
13 14
Deck 3
11 12
9 10
Deck 2
7 8
5 6
Deck 1
3 4
1 2
Angle
Positions 1 2 3 4 5 6 7 8 9 10 11 12
Spring Return
Model Positions Spring Return Decks Angle Handle
59
ø30 Series Accessories and Replacement Parts ø30
Terminal Covers
Terminal Cover
ø30 Series Switches & Pilot Lights
N-VL2 N-VL3 N-VL4 APN-PVL APD-PVL Use of termi-
nal covers
increases the
depth by the
dimensions
below.
Terminal Cover
Pilot Light
APN, APNE, UPQN, UPQNE
Full Voltage
X +5.0 mm
Pilot Light
APD, APDE X +5.2 mm
Pilot Light
APN, APNE, APD, APDE,
UPQN, UPQNE
Transformer
DC-DC Converter X +2.7 mm
Pushbutton
ABN, ABD, AON, AOD, AVN,
ABGD, AJN, ABFD, ATN,
AOFD, UBQN, AVD, UOQN,
AJD, UWQN, AZD, ABBN,
AYD, ABBS (ø25)
Selector Switch
ASN, ASD, ASTN
Selector Pushbutton
ABN, ASBD
1 contact block
X
+0 mm
2 contact blocks
X
2 pieces
3 contact blocks
X
2 pieces
4 contact blocks
X
2 pieces
Illuminated Pushbutton
ALN, ALD, ALNE, ALDE,
AOLN, AOLD, AOLNE,
AOLDE, ALGN, ALGD,
ALGNE, ALGDE, AOLGN,
AOLGDE, ALFN, ALFD,
ALFNE, ALFDE, AOLFN,
AOLFD, AOLFNE, AOLFDE,
AVLN, AVLD, AVLNE, AVLDE,
AJLN, AJLD, AJLNE, AJLDE,
ULQN, UOLQN
Illuminated Selector Switch
ASLN, ASLD
Push-to-Check Pilot Light
APN1∗∗P
Full Voltage X
2 pieces +4.5 mm
Transformer
DC-DC Converter X +1.5 mm
Ordering Terminal Covers
•When ordering terminal covers, specify the Part No. and the quantity.
38.4H × 22W 38H × 30.4W 38.4H × 24W 38H × 46W 37H × 44W
Terminal Cove
r
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
Terminal Cover
(N-VL2)
T
erminal Cover
(N-VL2)
ø30
60
ø30 ø30 Series Accessories and Replacement Parts
Nameplates
Model Legend Material Part No. Ordering No. Package
Quantity Dimensions (mm) Applicable Unit
NA
Blank
Aluminium
1.2mm thick
White letters on
black background
NA-0
NA-0 1
ø30.5
24.5
40
R17.5
ø30.5
24.5
40
R17.5
ø30 switches &
pilot lights
NA-0PN10 10
With Legend NA-
NA-1
NA-PN10 10
NALO Blank
Aluminium
1.2 mm thick
Black
NALO
NALO 1
ø30.5
40
30
47.5
R17.5
NALOPN10 10
MLO Blank
Brass
(chrome-plated)
1.0 mm thick
Matte
MLO
MLO 1
29.3
4
70
ø30.5
ø43
Letters should not be
engraved within this line
ARN/ARNS
Mono-Lever
MLOPN10 10
CQ
Blank
Aluminium
0.5 mm thick
White letters on
black background
CQ-0
CQ-0 1
• With adhesive tapes on
the back
UCSQO
Cam Switch
CQ-0PN10 10
With Legend
(Legend
Codes 31
and 53 only)
CQ-
CQ-1
CQ-PN10 10
CQM
Blank
Aluminium
0.5 mm thick
White letters on
black background
CQM-0
CQM-0 1
• With adhesive tapes on
the back
UCSQM
Cam Switch
CQM-0PN10 10
With Legend
(Legend
Code 31
only)
CQM-
CQM-1
CQM-PN10 10
•Specify a legend code in place of in the Ordering No.
20
ø13
2-ø3.5
64
40
5
12
2-ø3.5
ø13
64
61
ø30 Series Accessories and Replacement Parts ø30
Nameplates
Model Legend Material Part No. Ordering No. Package
Quantity Dimensions (mm) Applicable Unit
CQN
Blank
Aluminium
0.5 mm thick
White letters
on black
background
CQN-0
CQN-0 1
• With adhesive tapes on
the back
ACSNO, ACSNK
Cam Switches
ø30 mm Selector
Switches
CQN-0PN10 10
With Legend
(Legend
Codes 31, 35,
and 53 only)
CQN-
CQN-1
CQN-PN10 10
CQS
Blank
Aluminium
0.5 mm thick
White letters
on black
background
CQS-0
CQS-0 1
• With adhesive tapes on
the back
ACSSO, ACSSK
Cam Switches
ø25 mm Selector
Switches
CQS-0PN10 10
With Legend
(Legend Code
53 only) CQS-
CQS-1
CQS-PN10 10
•Specify a legend code in place of in the Ordering No.
ø30.5
64
ø25.5
64
Legends
Code Legend
0 (blank)
1 ON
2 OFF
3 START
4 STOP
31 OFF-ON
35 HAND-AUTO
53 HAND-OFF-AUTO
5
18.5
36 22
10
18.5
36 22
Shape and Engraving Area
Standard Large
Type NA Type NALO
Example
Shape
Engraving Area Max. No.
of Lines
No. of
Letters
on 1 Line
Height Width
Standard 5 36 1 14
Large 10 36 2 14
The above example is when the letter is 4 mm tall.
ø30
62
ø30 ø30 Series Accessories and Replacement Parts
Accessories
Shape Material Part No. Ordering No. Package
Quantity Dimensions (mm)
Locking Ring Wrench
Nitril rubber OR-12 OR-12 1
•Used to tighten the locking ring when installing
the ø30 or ø25 switch onto a panel.
ø37
ø45
ø46
90
ø34
ø
30
ø29
ø26
ø
22
ø30 Series
ø25 Series
Lamp Holder Tool
Nitril rubber OR-55 OR-55 1
•Used to install and remove the LED lamps.
See page 67.
Contact Rubber Boot
For momentary 1 layer of contact
blocks (2 contact blocks)
Nitril rubber
(black) OC-99 OC-99 1
•Rubber boot used to prevent oil and dirt from
entering into the contact block.
•Temperature range: –5 to +60°C
•Cannot be used for zinc diecast switches & pilot
lights.
18 42
44
52
Contact Rubber Boot For 1 layer
of contact
blocks
(2 contact
blocks)
Silicone rubber
(translucent)
OC-90 OC-90 1
•Applicable to AVN3 and AJN3.
•Applicable to ø30 diecast zinc pushbuttons and
selector switches.
(65.4)
38.8
42.8 42.4
For 2 layers
of contact
blocks
(4 contact
blocks)
OC-290 OC-290 1
Anti-rotation Ring
Metal
(diecast)
(zinc-plated)
OGL-11 OGL-11PN10 10
•Used to prevent the operator from turning.
Generally used when using no nameplates on
selector switches and selector pushbuttons.
ø30.5
ø39
2.80.8
Rubber Mounting Hole Plug
Nitril rubber
(black) OB-13B OB-13BPN05 5
•Used to plug unused
ø30mm mounting holes.
•Gray also available.
Ordering No.:
OB-13PN05
ø30
ø34
ø40
55
10
•Used to plug unused
ø30mm mounting holes.
•Gray also available.
Ordering Type No.:
OB-13PN05
Plastic Mounting Hole Plug
Plastic (gray)
Plug: ABS
Gasket:
Chloroprene
rubber
OBP-11 OBP-11 1
•Tightening torque: 1.2 N· m.
•Degree of protection: IP65
M30
P1.5
Screw
Locking Ring
Gasket
4
ø36
5
24
Metallic Mounting Hole Plug
Metal
(diecast)
(zinc-plated)
OB-11 OB-11 1
•Tightening torque: 1.2 N· m.
•Degree of protection: IP65
ø36
45
24
M30
P1.5
Screw
Locking Ring
Gasket
59
14
ø11.6
OR-55
63
ø30 Series Accessories and Replacement Parts ø30
Accessories
Shape Material Part No. Ordering
No.
Package
Quantity Dimensions (mm)
Button Cover for
Extended Pushbuttons
Nitril rubber
Color Part No.
M30
P1.5
ø38
ø28
11
19
•Metallic bezels
cov ered with a
rubber boot to
enhance waterproof
characteristics.
•
Button is not included.
Applicable to extended
pushbuttons only.
Black OC-11B OC-11B
1
Green OC-11R OC-11R
Red OC-11G OC-11G
Yellow OC-11Y OC-11Y
Button
Clear Boot
For ush
pushbuttons
EPDM rubber
OC-121 OC-121 1
•Used to cover and
pro tect pushbuttons
where units are subject
to water splash. Not
suit able for outdoor use
or where the units are
sub ject to oil splash.
A
B
A B
OC-121 37 16
OC-122 37 16
For extended
pushbuttons
OC-122 OC-122 1
Dust-proof Rubber Cover
for Jumbo Mushrooms
Nitril rubber
(black) OC-4GN OC-4GN 1
32
ø80
Panel Thickness
1.2 to 5.5
•Used for ABN4G
pushbuttons.
Padlock Cover
Polyarylate
(gasket: nitryl
rubber)
OL-KL1 OL-KL1 1
•Used to protect pushbuttons, illuminated push-
buttons, and selector switches (knob operator)
.
Metal Protector
Metal
(zinc-plated
brass)
OL-C OL-C 1
•Used to protect ush pushbuttons from
inadvert ent operation.
•Can be easily attached using the locking ring.
Mounting Centers
50 min.
25 5
ø30.5
16
11.5
1.6
42.5
Locking Attachmentt
Metal
(zinc-plated
brass)
OL-H OL-H 1
•Used to lock an extended pushbutton in the
depressed position.
•Can be easily attached using the locking ring.
ø6 hole
Locking Plate
Mounting Plate
30
16.5
9.5
Waterproof Rubbe
r
Gasket 0.5t
24
Key Hole ø8
30
70
ø50
ø30.2
93
29.5
30
R66.5
Panel Thickness
0.8 to 3.2
82.5
ø30
64
ø30 ø30 Series Accessories and Replacement Parts
Maintenance Parts
Shape Specication Part No. Ordering No. Package
Quantity Remarks
Metallic Bezel
Metal
(zinc diecast: chrome-
plated)
OG-11 OG-11PN02 2
• Cannot be used with pin lock,
selector pushbuttons, and mono-
lever units.
Plastic Bezel
Polycarbonate OGP-11OGP-11PN02 2
Specify a color code in place of .
B (black), G (green), R (red), W
(white),
Y (yellow)
• Cannot be used with pin lock,
selector pushbuttons, and mono-
lever units.
Clear Plastic Bezel for Flush
Pushbuttons
Acrylic (clear)
OGP-13 OGP-13PN02 2
• Clear plastic bezel and full
shroud.
• OGP-1411 cannot be used with
LED illumination units and diecast
units.
Clear Plastic Bezel for
Extended Pushbuttons
OGP-14 OGP-14PN02 2
Clear Plastic Bezel for
Illuminated Pushbuttons
OGP-1411 OGP-1411 1
Metal Bezel for Illuminated
Pushbuttons
Metal
(zinc diecast) OL-11 OL-11PN05 5
Clear Button Cover
Polycarbonate (clear) ABN1B-C ABN1B-CPN05 5
• Used on ush and extended
pushbut tons to indicate a mark or
a symbol engraved on the mark-
ing plate. The clear button cover
holds the marking plate. The ø30
series marking chip can only be
used on the ABN1 and AON1.
• Specify a color code in place of .
B (black), G (green), R (red), W
(white), Y (yellow)
Marking Plate
Polyacetal TN-0TN-0PN10 10
65
ø30 Series Accessories and Replacement Parts ø30
Maintenance Parts
Shape Description Mate rial Part No. Ordering No.
Package
Quantity
Color
Contact Block
(BS: Dark gray) NO contact BS010E BS010E 1•Push rod color: Green
•-MAU has gold contacts
BS010E-MAU BS010E-MAU
NC contact BS001E BS001E 1•Push rod color: Red
•-MAU has gold contacts
BS001E-MAU BS001E-MAU
EM contact
(early make)
BS010SE BS010SE 1•Push rod color: Black
•-MAU has gold contacts
BS010SE-MAU BS010SE-MAU
LB contact
(late break)
BS001SE BS001SE 1•Push rod color: White
•-MAU has gold contacts
BS001SE-MAU BS001SE-MAU
Contact Block
(BST: Light gray) NO contact BST010 BST010 1•Push rod
color: Green •-MAU has gold
contacts
Applicable Units:
•Pushlock Turn Reset
•Push Turn Lock
•LED Illuminated
Pushbutton
•LED Illuminated
Selector Switch
BST010-MAU BST010-MAU
NC contact BST001 BST001 1•Push rod
color: Red
BST001-MAU BST001-MAU
EM contact
(early make) BST010S BST010S 1•Push rod
color: Black
LB contact
(late break) BST001S BST001S 1•Push rod
color: White
Lens
Used for
APN(E)1
AS resin
APN106LN-APN106LN-PN05 5
A (amber), C (clear), G (green),
R (red), S (blue), W (white), Y (yellow)
•Use the white (W) lens for pure white
(PW) illumination
Used for
UPQNE4
U(O)LQNB
UPQN406L-UPQN406L-PN05
5
C (clear), G (green), R (red), S (blue)
•Use the clear (C) lens for white
illumi nation.
UPQN406LD-
UPQN406LD-PN05
A (amber), Y (yellow)
•Use the amber (A) lens for orange
illu mination.
Used for
UPQN3B
U(O)LQN
ULQN06L-ULQN06L-PN05
5
C (clear), G (green), R (red), S (blue)
UPQN06LD-UPQN06LD-PN05
A (amber), W (white), Y (yellow)
•Use the amber (A) lens for orange
illu mination.
Lens
Used for
ALN, AOLN
(LED)
AS resin
ALN2L-ALN2L-PN05 5C (clear), G (green), R (red), S (blue)
ALN2LD-ALN2LD-PN05 5A (amber), W (white), Y (yellow)
•Use the white (W) lens for pure white
(PW) illumination
Button Flush
Polyacetal
ABN1B-ABN1B-PN05 5G (green), R (red), Y (yellow)
Above colors are used for ø30 switches
& pilot lights (dark colored operator
units).
For black, use black buttons from light
colored operator units.
Extended ABN2B-ABN2B-PN05 5
Mushroom ABN3B-ABN3B-PN02 2
Button Flush ABN1BN-ABN1BN-PN05 5B (black), G (green), R (red), S (blue),
Y (yellow), W (white)
Above colors are used for ø30 diecast
zinc switches & pilot lights (light
colored operator units).
Extended ABN2BN-ABN2BN-PN05 5
Mushroom ABN3BN-ABN3BN-PN02 2
Button Mushroom
(ABN4)
Urea-
formaldehyde
resin
ABN4B-ABN4B-1
B (black), G (green), R (red), Y (yellow)
Mushroom
(ABN4G/
ABN4F)
ABN4GB-ABN4GB-1
Square Flush
(UBQN1)
Polyacetal
UBQN1B-UBQN1B-PN02 2
Square
Extended
(UBQN2)
UBQN2B-UBQN2B-PN02 2
Note: Specify a button color code or Lens/LED Color Code in place of or in the Ordering No.
ø30
66
ø30 ø30 Series Accessories and Replacement Parts
Maintenance Parts
Shape Description Material Part No. Ordering No.
Package
Quantity
Remarks
Button For ø40 pushlock
turn reset
pushbuttons
(for AVN3)
AS resin AVN3B-AVN3B-1 R (red), Y (yellow)
Lens For ø40 pushlock
turn reset
pushbuttons
(for AVLN3,
AVLNE3)
AS resin AVLN3L-R AVLN3L-RPN02 2 Red only
Lens For ø40 pushlock
turn reset
pushbuttons
(for AJN3)
AS resin AJN3B-AJN3B-1B (black), G (green),
R (red), Y (yellow)
Lens For ø40 pushlock
turn reset
pushbuttons
(for AJLN3)
AS resin AJLN3L-AJLN3L-1
-G (green),
-R (red), L-Y (yellow),
L-A (amber), L-W (white)
Marking Plate
For UPQN4 Acrylic UPQN406N-W UPQN406N-WPN05 5
Rubber Washer (3.0mm thick)
Synthetic
soft vinyl
OW-12 OW-12PN10 10
Rubber Washer (1.5mm thick)
OW-11 OW-11PN10 10
Shroud
Half shroud
(for pushbuttons)
Metal
(zinc
diecast)
ABN2G ABN2G 1
Full shroud
(for pushbuttons) ABN2F ABN2F 1
Full shroud
(for mushroom
pushbuttons)
ABN3G ABN3G 1
Shallow shroud
(for jumbo mush-
rooms)
ABN4G ABN4G 1
Deep shroud
(for jumbo mush-
rooms)
ABN4F ABN4F 1
Half shroud
(for illuminated
pushbuttons)
ALN2GL ALN2GL 1•For LED illuminated
pushbuttons (BA9S base)
Full shroud
(for illuminated
pushbuttons)
ALN2FL ALN2FL 1•For LED illuminated push-
buttons (BA9S base)
Selector Knob
Knob for
Illuminated
selector switch
AS resin
ASLNH ASLNH-
1
G (green), R (red),
S (blue)
ASLNHD ASLNHD-A (amber), W (white),
Y (yellow)
67
ø30 Series Accessories and Replacement Parts ø30
Maintenance Parts
Shape Description Material Part No. Ordering No.
Package
Quantity
Remarks
Spare Key
ASN3K/4K,ABN5
Metal
(nickel
plated
brass)
ASN-T1SK-24401 ASN-T1SK-24401PN02
2
•Applicable to
ABN3K, ABN4K,
ABN5
ASNKASN-SK-24401 ASN-SK-24401PN02
Spare Key ASNK-T
ASNKTW-SK-0 TW-SK-0PN02 2
Transformer
100/110V AC
(for LED lamps) TWR-016N TWR-016N 1
Mounting screws are
not included.
200/220V AC
(for LED lamps) TWR-026N TWR-026N 1
Pin/Chain
For ABN8P
pinloock Metal ABN8P-PIN ABN8P-PIN 1Pin, chain, and plate
for ABN8P
LED Lamps
Dimensions Operating
Voltage
Current Draw Part No. Ordering No. Illumination
Color Code
Package
Quantity Base
AC DC
6V AC/DC ±10% 8 mA
7 mA
(A, R, W)
5.5 mA
(G, PW, S)
LSTD-6
LSTD-6A: amber
G: green
PW: pure white
R: red
S: blue
W: white
Use a pure white
(PW) LED lamp
for yellow (Y)
illumination.
1
BA9S/13
LSTD-6PN10 10
12V AC/DC
±10% 11 mA 10 mA LSTD-1
LSTD-11
LSTD-1PN10 10
24V AC/DC
±10% 11 mA 10 mA LSTD-2
LSTD-21
LSTD-2PN10 10
Base BA9S/13
20.8
ø30
68
ø30 ø30 Series Accessories and Replacement Parts
Transformer
DIN Rail Mount Primary Voltage Secondary Voltage Part No. Applicable Load
For 6V 100/110V AC
5.5V
TWR516
One full voltage pilot light or illuminated
switch containing LSTD-6
200/220V AC TWR526
400/440V AC TWR546
For 24V LED 100/110V AC
23V
TWR512
One full voltage pilot light or illuminated
switch containing LSTD-2)
200/220V AC TWR522
400/440V AC TWR542
Specifications
Part No. TWR56 TWR52
Operating Voltage
100/110V AC, 200/220V AC, 400/440V AC (50/60Hz)
Current Draw 2.4 VA
Rated Insulation
Voltage 600V
Insulation Resistance 100 MΩ minimum (500V DC megger)
Operating Temperature –30 to +60°C (no freezing)
Storage Temperature –40 to +80°C (no freezing)
Operating Humidity 35 to 85% RH (no condensation)
Vibration Resistance Damage Limits: 30 Hz, amplitude 1.5 mm
Operating extremes: 5 to 55 Hz, amplitude 0.5 mm
Shock Resistance Damage limits, Operating Extremes: 1,000 m/s2
Dielectric Strength 2,500V AC, 1 minute
Terminal Screw M3.5
Applicable Wire 2 mm2 maximum, 2 wires maximum
Weight (approx.) 87g
Accessories
DIN Rail
Part No. Ordering No. Length Weight (approx.) Material Package Quantity
BAA1000 BAA1000PN10 1000 mm 200g Aluminum 10
BAP1000 BAP1000PN10 1000 mm 320g Steel 10
End Clip
Part No. Ordering No. Applicable DIN Rail Weight (approx.) Material Package Quantity Dimensions
BNL6 BNL6PN10 BAA1000
BAP1000 15g Steel
(Zinc-plated) 10
(24)
45 9
Dimensions
45.5
52
41
40
48
40
22
30
BAA1000
1
3 4
JAPAN
2
PRI.
SEC.
M3.5 Terminal Screw
Terminal Cover
Secondary Side Primary Side
2–ø3.3
Mounting Hole
69
ø30 Series Instructions ø30
Safety Precautions
•Turn off the power to the ø30 series switches & pilot lights
before starting installation, removal, wiring, maintenance,
and inspection of the products. Failure to turn power off
may cause electrical shocks or re hazard.
•To avoid a burn on your hand, use the lamp holder tool
when replacing lamps.
•For wiring, use wires of a proper size to meet the volt-
age and current requirements. Tighten the M3.5 terminal
screws to a tightening torque of 1.0 to 1.3 N·m. Failure to
tighten terminal screws may cause overheat and re.
Instructions
Panel Mounting for Square Pushbuttons
and Pilot Lights
1. Tighten the square ring to the operator and position the
ring correctly.
2. Lightly tighten the screw to secure the pilot light onto the
panel.
Tightening Torque for Terminal Screws
Tighten the terminal screws to a torque of 1.0 to 1.3 N·m.
Replacement of Lamps
Lamps can be replaced by using the lamp holder tool (OR-
55) from the front of the panel.
How to Remove
To remove, slip the lamp holder tool onto the lamp head
lightly. Then push slightly, and turn the lamp holder tool
counterclockwise.
How to Install
To install, insert the lamp head into the lamp holder tool.
Place the pins on the lamp base to the grooves in the
lamp socket. Inset the lamp and turn it clockwise.
Installing the Anti-rotation Ring
Panel Thickness and Rubber Washer
Adjust the thickness of the rubber washers according
to the panel thickness. Also, make sure to include the
nameplate thickness when using a nameplate.
Recommended tightening
torque: 0.15 N·m
OR-55
Rubber Washer
Panel OGL11
Anti-rotation rings are used
on selector switches or
pushbuttons which rotate
and used when using no
nameplates.
Insert a 1.5mm thick rubber
washer between the panel
and the anti-rotation ring as
shown on the right.
Applicable Models
•Extended Illuminated Pushbuttons
with Half Shroud (LED)
•Extended Pushbuttons with Half
Shroud (Diecast)
•Extended Illuminated Pushbuttons
with Half Shroud (Diecast)
Panel
Thickness
(mm)
Rubber Washer
1.5mm 3.0mm
Supplied 1 piece 1 piece
0.8 to 1.8 1 piece
1.8 to 3.5 1 piece
Applicable Models
•Extended Illuminated Pushbuttons
with Full Shroud (LED)
•Extended Illuminated Pushbuttons
with Full Shroud (Diecast)
•Mushroom Pushbuttons with Full
Shroud
Panel Thickness
(mm)
Rubber Washer
1.5mm 3.0mm
Supplied
2 pieces
1 piece
0.8 to 2.0 1 piece 1 piece
2.0 to 3.5 1 piece 1 piece
3.5 to 5.0 1 piece
5.0 to 6.0 (6.5) 1 piece
The number in brackets is for mush-
room pushbuttons with full shroud.
Applicable Models
•Toggle Lever
•Knob Push Turn Lock Illuminated
Pushbuttons
Panel Thickness
(mm)
Rubber Washer
1.5mm 3.0mm
Supplied 1 piece 1 piece
0.8 to 2.0 1 piece 1 piece
2.0 to 3.5 1 piece
3.5 to 5.5 (5.0) 1 piece
The number in brackets is for knob
push turn lock illuminated pushbut-
tons.
Applicable Models
•Extended Pushbuttons with Half
Shroud
Panel
Thickness
(mm)
Rubber Washer
1.5mm 3.0mm
Supplied 1 piece 1 piece
0.8 1 piece 1 piece
0.8 to 2.3 1 piece
2.3 to 4.0 1 piece
Applicable Models
•Extended Pushbuttons with Full
Shroud
Panel
Thickness
(mm)
Rubber Washer
1.5mm 3.0mm
Supplied 3 pieces 1 piece
0.8 to 1.5 3 pieces 1 piece
1.5 to 3.0 2 pieces 1 piece
3.0 to 4.5 1 piece 1 piece
4.5 to 6.0 1 piece
6.0 to 7.5 1 piece
Applicable Models
•Extended Pushbuttons with Full
Shroud (Diecast)
Panel
Thickness
(mm)
Rubber Washer
1.5mm 3.0mm
Supplied 2 pieces 1 piece
0.8 to 2.5 2 pieces 1 piece
2.5 to 4.0 1 pieces 1 piece
4.0 to 5.5 1 piece
5.5 to 6.0 1 piece
Applicable Models
•Other Models (Excluding Square)
Panel
Thickness
(mm)
Rubber Washer
1.5mm 3.0mm
Supplied 2 pieces 1 piece
0.8 to 3.5 2 pieces 1 piece
3.5 to 5.0 1 piece 1 piece
5.0 to 6.5 1 piece
6.5 to 7.5 1 piece
ø30
70
ø30 ø30 Series Instructions
Installation of LED Illuminated Units
1. Note the polarity for wiring when connecting to DC-DC
converter unit.
Terminal No. Polarity
X1 Positive
X2 Negative
2. Transformer units are recommended for use in areas
subjected to noise.
3. Notes for Pure White LED Lamps
•Do not use the pure white LED outdoors, otherwise it will
lead to the degradation of brightness and color. Do not
remove or apply shock to the cap on the pure white LED
lamp, otherwise it may break or damage the cap.
•For the pure white LED, use a white lens. The illumination
color will be dull if a different color is used.
Notes on LED Illuminated Units
LED lamps consist of semiconductors. If the applied
voltage exceeds the rated voltage, LED elements may
deteriorate due to overheat, resulting in signicant
decrease in lumi nance, hue change, or failure of lighting.
Also, if an extrane ous noise, transient voltage, or transient
current is applied to the circuit, similar effects may occur.
When using LED lamps, observe the following instructions.
Rated Voltage
The LED lamps are rated at 6V, 12V, or 24V AC/DC, and
can be used within ±10% the rated voltage of either AC or
DC.
DC Power
1. Switching power supply
Regulated voltage from switching power supply is best
suited. Make sure to use within the rated voltage of the
LED lamp.
2. Rechargeable battery
Note that the battery voltage may exceed the rated volt-
age of the LED lamp while the battery is being charged
and immediately after the charging is complete. Be sure
to use the LED lamp on a voltage of ±10% the rated
volt age.
3. Full-wave rectication
Since the LED lamp is AC/DC compatible, a diode
bridge for rectication is not necessary. If the LED lamp
is used on a full-wave rectication current through a
diode bridge, the rectier diodes will reduce the voltage,
result ing in lower luminance.
4. Single-phase half-wave rectication
This is not suitable for the power source of LED lamps.
Use constant-voltage DC power.
Noise
LED elements deteriorate due to extraneous noise, result-
ing in signicant decrease in luminance, hue change, or
fail ure of lighting. When such effects are anticipated, take a
protection measure shown below, such as RC elements or
a surge absorber.
[Protection Example 1] For AC circuit
LED with
transformer LED R
C
LED
Ry
Relay
coil or
solenoid R
C
LED with
transformer
(Reference values) R: 120Ω
C: 0.1 μF
[Protection Example 2] For DC circuit
Ry LED Diode
Relay
coil or
solenoid
+
(Reference values of the diode)
Forward current: More than the Ry coil current
Reverse withstand voltage: Ry coil current ¥ 10
Countermeasures against Dim Lighting
1. Leakage currents through the transistors or a contact
protection circuit may cause the LED lamp to illuminate
dimly even when the output is off.
2. When the LED lamp is illuminated by a transistor output,
take the following measure.
[Circuit Example]
Connect shunt resistor R in parallel with the LED lamp.
R
Io
Io: Leakage current when the output is off
R: Shunt resistor
LED
71
ø30 Series Diecast Zinc Switches & Pilot Lights
Heavy duty switches for tough industrial usage
•Degree of protection: IP65 (IEC 60529)
•UL, CSA approved, and EN compliant
Applicable Stan-
dards Mark File No. or Organization
UL 508 UL Listing
File No. E68961
CSA C22.2 No.14 CSA File No. LR21451
EN60947-5-1 EU Low Voltage Directive
GB14048.5 CCC No. 200501030514650
Specifications and Ratings
Contact Ratings Weight (Examples)
Pushbuttons
Illuminated Pushbuttons
Selector Switches
Illuminated Selector Switches
Selector Pushbuttons
Contact Block BST (ø30 series)
Rated Insulation Voltage 600V
Rated Continuous Current 10A
Contact Ratings by Utilization Category
IEC 60947-5-1
AC-15 (A600)
DC-13 (P600)
Characteristics
Contact Ratings by Utilization Category
Operational Voltage 24V 48V 50V 110V 220V 440V
Operational
Current
AC
50/60 Hz
AC-12 Control of resistive loads and solid state loads 10A 10A 10A 6A 2A
AC-15 Control of electromagnetic loads (> 72 VA) 10A 7A 5A 3A 1A
DC DC-12 Control of resistive loads and solid state loads 10A 5A 2.2A 1.1A
DC-13 Control of electromagnets 5A 2A 1.1A 0.6A
Note: The operational current represents the classication by making and breaking currents (IEC 60947-5-1).
Minimum applicable load: 3V AC/DC, 5 mA (applicable range may vary with operating conditions and load types)
BST Contact Block (Light Gray)
Specications, ratings, and mounting hole layouts are the same as ø30 switches & pilot lights.
See “ø30 Series Switches & Pilot Lights” on page16.
Weight
(approx.)
135g (ABD 122N)
71g (APD122DN)
116g (ALD22211DN)
125g (ASD222N)
168g (ASD2K22N)
147g (ASLD22222DN)
116g (ASBD211N-A03)
Push Rod
M3.5 Terminal Screw
Inspection
Window
Interlock-
ing Groove
Mounting
Screw
Contact Blocks
Contact
Single-pole Contact Block
1NO 1NC
1EM (early make)
1LB (late break)
Part
No. BST BST010 BST001 BST010S BST001S
Push Rod Green Red Black White
Note: BST contact blocks are not interchangeable with dark gray BS con-
tact blocks used for ø30 switches & pilot lights.
ø30
72
ø30 ø30 Series Diecast Zinc Switches & Pilot Lights
Ordering Information
The Part No. development charts shown below can be used to specify switches & pilot lights other than those listed on the
following pages.
Standard Units
•Specify an operator or Lens/LED Color Code in the Part
No.
•Black, green, and red colored buttons are included with
ush pushbuttons.
•Terminal covers, nameplates, and accessories are or-
dered separately.
Terminal Cover
•When a terminal cover is required, order an applicable
terminal cover referring to page 59.
ø30 Series Diecast Zinc Pushbuttons
ABD2
11 N R
Button color code
Contact Conguration
10: 1NO 01: 1NC
11: 1NO-1NC 20: 2NO
02: 2NO 22: 2NO-2NC
40: 4NO 04: 4NO
13: 1NO-3NC 31: 3NO-1NC
30: 3NO 03: 3NC
12: 1NO-2NC 21: 2NO-1NC
Note:
•Mushroom pull AZD3 can have a maximum of two contact
blocks.
•Mushroom push pull AYD31 can have a maximum of two
contact blocks.
ø30 Series Diecast Zinc Pilot Lights
APD
E 1 99 D N R
ø30 Series Diecast Zinc Illuminated
Pushbuttons
ALD
E 2 16 11 D N R
Lens/LED Color Code
Contact conguration
11: 1NO-1NC 20: 2NO
02: 2NC 31: 3NO-1NC
22: 2NO-2NC 13: 1NO-3NC
40: 4NO 04: 4NC
Operating voltage code
Lamp receptacle
(blank): BA9S (LSTD-6 LED)
Note:
•Illuminated pushbuttons cannot have an odd number of con-
tact blocks, such as 1NO, 1NC, 3NO, 2NO-1NC, 1NO-2NC,
and 3NC.
Lens/LED Color Code
Operating voltage code
Lamp receptacle:
(blank): BA9S (LSTD-6 LED)
73
ø30 Series Diecast Zinc Switches & Pilot Lights ø30
ø30 Series Diecast Zinc Selector Switch
ø30 Series Diecast Zinc
Key Selector Switch
ø30 Series Diecast Zinc
Illuminated Selector Switch
ASD
2 L 11 N
Contact conguration
Operator
(blank): Knob
L: Lever
Number of positions
ASD
2 K 20 N B
Key removable position code
2-position
•Maintained
(blank): Removable in all positions
B: Removable in left only
C: Removable in right only
•Spring return from right
(blank): Removable in left only
•Spring return from left
(blank): Removable in right only
3-position
•Maintained
(blank): Removable in all positions
B: Removable in left and center
C: Removable in right and center
D: Removable in center only
E: Removable in right and left
G: Removable in left only
H: Removable in right only
•Spring return from right
(blank): Removable in left and center
D: Removable in center only
G: Removable in left only
•Spring return from left
(blank): Removable in right and center
D: Removable in center only
H: Removable in right only
•Spring return two-way
(blank): Removable in center only
Contact conguraion
Number of positions
Note:
•The key cannot be removed in the return position.
ASLD
2 16 22 D N R
Lens/LED Color Code
Contact conguration
Operating voltage code
Number of positions
ø30
74
ø30 ø30 Diecast Zinc Series Pushbuttons
Flush / Extended / Extended with Half Shroud / Extended with Full Shroud
Shape Operation Contact Part No. Button Color
Code Dimensions (mm)
Flush
ABD1
Momentary
1NO ABD110N
Black (B), green
(G), and red
(R) buttons are
sup plied with
each unit.
Specify S, Y,
or W when a
blue, yellow, or
white button is
required.
1NC ABD101N
1NO-1NC ABD111N
2NO ABD120N
2NC ABD102N
2NO-2NC ABD122N
Flush
AOD1
Maintained
1NO AOD110N
1NC AOD101N
1NO-1NC AOD111N
2NO AOD120N
2NC AOD102N
2NO-2NC AOD122N
Extended
ABD2
Momentary
1NO ABD210N
Specify a button
color code in
place of in
the Part No.
B: black
G: green
R: red
S: blue
W: white
Y: yellow
1NC ABD201N
1NO-1NC ABD211N
2NO ABD220N
2NC ABD202N
2NO-2NC ABD222N
Extended
AOD2
Maintained
1NO AOD210N
1NC AOD201N
1NO-1NC AOD211N
2NO AOD220N
2NC AOD202N
2NO-2NC AOD222N
Extended with Half Shroud
ABGD2
Momentary
1NO ABGD210N
1NC ABGD201N
1NO-1NC ABGD211N
2NO ABGD220N
2NC ABGD202N
2NO-2NC ABGD222N
Extended with Half Shroud
AOGD2
Maintained
1NO AOGD210N
1NC AOGD201N
1NO-1NC AOGD211N
2NO AOGD220N
2NC AOGD202N
2NO-2NC AOGD222N
Extended with Full Shroud
ABFD2
Momentary
1NO ABFD210N
1NC ABFD201N
1NO-1NC ABFD211N
2NO ABFD220N
2NC ABFD202N
2NO-2NC ABFD222N
Extended with Full Shroud
AOFD2
Maintained
1NO AOFD210N
1NC AOFD201N
1NO-1NC AOFD211N
2NO AOFD220N
2NC AOFD202N
2NO-2NC AOFD222N
•Round bezel and shroud (metal): Chrome-plated
•Pushbuttons with one or three contact blocks contain a dummy block
•Other contact congurations are also available. See page 72.
M3.5 Terminal Screw
623
9
Panel Thickness 0.8 to 7.5
ø35
36
40
68 (1 to 2 blocks)
91 (3 to 4 blocks)
5.5 23
9
Panel Thickness 0.8 to 7.5
ø35
40
ø25
ø40
14.5
53 (1 or 2
blocks)
76 (3 or 4 blocks)
M3.5 Terminal Screw
5.5 23
ø35
40
ø25
ø40
Panel Thickness 0.8 to 3.5
49.5 (1 or
2 blocks)
72.5 (3 or 4 blocks)
20.5
ø27
M3.5 Terminal Screw
5.5 23 40
ø40
51.5 (1 or
2 blocks)
74.5 (3 or 4 blocks)
ø35
ø25
ø28.5
17
Panel Thickness 0.8 to 6
M3.5 Terminal Screw
75
ø30 Diecast Zinc Series Pushbuttons ø30
Mushroom / Jumbo Mushroom Pushbuttons
Shape Operation Contact Part No. Button Color
Code Dimensions (mm)
Mushroom
ABD3
Momentary
1NO ABD310N
B: black
G: green
R: red
W: white
Y: yellow
1NC ABD301N
1NO-1NC ABD311N
2NO ABD320N
2NC ABD302N
2NO-2NC ABD322N
Mushroom
AOD3
Maintained
1NO AOD310N
1NC AOD301N
1NO-1NC AOD311N
2NO AOD320N
2NC AOD302N
2NO-2NC AOD322N
Mushroom with Full Shroud
ABGD3
Momentary
1NO
ABGD310N
1NC
ABGD301N
1NO-1NC
ABGD311N
2NO
ABGD320N
2NC
ABGD302N
2NO-2NC
ABGD322N
Mushroom with Full Shroud
AOGD3
Maintained
1NO
AOGD310N
1NC
AOGD301N
1NO-1NC
AOGD311N
2NO
AOGD320N
2NC
AOGD302N
2NO-2NC
AOGD322N
Jumbo Mushroom
ABD4
Momentary
1NO ABD410N
B: black
DG: dark green
DR: dark red
G: green
R: red
Y: yellow
5.523
53 (1 or
2 blocks)
76 (3 or 4 blocks)
Panel Thickness 0.8 to 7.5
29
ø65
M3.5 Terminal Screw
1NC ABD401N
1NO-1NC ABD411N
2NO ABD420N
2NC ABD402N
2NO-2NC ABD422N
Jumbo Mushroom with
Shallow Shroud
ABGD4
Momentary
1NO
ABGD410N
5.5 23
53 (1 or
2 blocks)
76 (3 or 4 blocks)
Panel Thickness 0.8 to 7.5
ø75
ø65
29
M3.5 Terminal Screw
1NC
ABGD401N
1NO-1NC
ABGD411N
2NO
ABGD420N
2NC
ABGD402N
2NO-2NC
ABGD422N
Jumbo Mushroom with
Deep Shroud
ABFD4
Momentary
1NO ABFD410N
5.523
53 (1 or
2 blocks)
76 (3 or 4 blocks)
Panel Thickness 0.8 to 7.5
32.5
ø75
M3.5 Terminal Screw
1NC ABFD401N
1NO-1NC ABFD411N
2NO ABFD420N
2NC ABFD402N
2NO-2NC ABFD422N
•Specify a button color code in place of in the Part No.
•Round bezel and shroud (metal): Chrome-plated
•Pushbuttons with one or three contact blocks contain a dummy block
•Other contact congurations are also available. See page 72.
M3.5 Terminal Screw
5.5 23 40
ø40
53 (1 or 2
blocks)
76 (3 or 4 blocks)
22
ø40
Panel Thickness 0.8 to 7.5
5.5 23
23
ø48
52 (1 or
2 blocks)
75 (3 or 4 blocks)
Panel Thickness 0.8 to 6.5
M3.5 Terminal Screw
ø30
76
ø30 ø30 Diecast Zinc Series Pushbuttons
Pushlock Turn Reset / Push Turn Lock / Pull / Push-Pull / Pin Lock Pushbuttons
Shape Contact Part No. Button Color
Code Dimensions (mm)
Mushroom Pushlock Turn Reset
AVD3 1NO AVD310N
R: red
Y: yellow
M3.5 Terminal Screw
40
53 (1 or 2
blocks)
76 (3 or 4 blocks)
ø40
Panel Thickness 0.8 to 7.5
24
36
5.5 23
1NC AVD301N
1NO-1NC AVD311N
2NO AVD320N
2NC AVD302N
2NO-2NC AVD322N
Mushroom Push Turn Lock
AJD3
1NO AJD310N
B: black
G: green
R: red
Y: yellow
M3.5 Terminal Screw
K
P
U
S
H
L
O
C
40
53 (1 or 2
blocks)
76 (3 or 4 blocks)
ø40
Panel Thickness 0.8 to 7.5
24
36
5.5 23
1NC AJD301N
1NO-1NC AJD311N
2NO AJD320N
2NC AJD302N
2NO-2NC AJD322N
Mushroom Pull
AZD3 1NO AZD310N
B: black
G: green
R: red
S: blue
Y: yellow
1NO-1NC AZD311N
2NO AZD320N
2NC AZD302N
Mushroom Push-Pull
AYD31
1NO-1NC AYD3111N
2NO AYD3120N
2NC AYD3102N
Pin Lock
ABD8P
1NO ABD8P10N
40
49
Panel Thickness
0.8 to 7.5
ø28
ø35
ø40
52
76 (3 or 4 blocks)
28.5
53 (1 or
2 blocks)
5.5 23
M3.5 Terminal Screw
1NC ABD8P01N
1NO-1NC ABD8P11N
2NO ABD8P20N
2NC ABD8P02N
2NO-2NC ABD8P22N
40
53 (1 or 2 blocks)
ø40
Panel Thickness 0.8 to 7.5
36
5.5 23
30.5
M3.5 Terminal Screw
•
Specify a button color code in place of in the Part No.
•
Round bezel (metal): Chrome-plated
•
Pushbuttons with one or three contact blocks contain a dummy
block.
•
Other contact congurations are also available. See page 72.
•
Pushlock Turn Reset: Button is maintained when pressed and
is reset when turned clockwise. Red buttons only.
Note: AVD3 pushlock turn reset switches cannot be used as
emer gency stop switches. When emergency stop switch-
es are required, use XN or HN series emergency stop
switches (ISO 13850 and IEC 60947-5-5 compliant).
•
Push Turn Lock: Button is locked when turned clockwise in the
depressed position and is reset when turned counterclockwise.
•
Pull: Pulling the button operates the contacts. Up to 2 contact
blocks (1 layer) can be mounted on pull switches.
•
Push-Pull: Button is maintained in both depressed and reset
positions. Up to 2 contact blocks (1 layer) can be mounted on
AYD31 push-pull switches.
Note: AYD31 push-pull switches cannot be used as emergency
stop switches. When emergency stop switches are
required, use the HN1E series emergency stop switches
(ISO 13850 and IEC 60947-5-5 compliant).
•
Pin Lock: Button can be locked in either depressed or reset
posi tion by inserting the pin. Pad lock with a ø5mm pin can also
be used to lock the button.
Pull Switch (Spring Return)
Contact AZD3
Normal Pull
1NO
1NC
1NO-1NC
2NO
2NC
Push-Pull Switch (Maintained)
Contact AYD31
Push Pull
1NO-1NC
2NO
2NC
Contact Operation
Note: Pull and push-pull switches can have a maximum of two
contact blocks.
77
ø30 Diecast Zinc Series Pilot Lights ø30
APD1 / APDE1 Dome Pilot Lights
Shape Lamp Lamp
Receptacle Part No. Lens/LED Color Code Applicable
Lamp
Dome
APD1
APDE1
Without Lamp BA9S APD199N
A: amber C: clear
G: green R: red
S: blue W: white
DNY: yellow
See page 17
for lamps.
LED BA9S APD1DN
A: amber G: green
PW: pure white R: red
S: blue W: white
Y: yellow
Operating Voltage Code
Specify an operating voltage code in place of in the Part No.
Operating Voltage Code Input
66: 6V AC/DC
11: 12V AC/DC
22: 24V AC/DC
Full Voltage
16: 100/110V AC
126: 120V AC
26: 200/220V AC
246: 240V AC
386: 380V AC
46: 400/440V AC
Transformer
•Specify a lens/LED color code in place of in the Part No.
•Use a pure white (PW) LED for yellow (Y) illumination..
Dimensions
Full Voltage
Transformer
M3.5 Terminal Screw
29.5
9
21
40
ø25
ø35
ø40
Panel Thickness 0.8 to 7.5
M3.5 Terminal Screw
9
64.521
40
ø25
ø35
ø40
Panel Thickness 0.8 to 7.5
All dimensions in mm.
ø30
78
ø30 ø30 Diecast Zinc Series Illuminated Pushbuttons
ALD2 / AOLD2 Round Extended Illuminated Pushbuttons
Shape Lamp
Receptacle Operation Lamp Contact Part No. Applicable
Lamp
Round Extended
ALD2
AOLD2
BA9S
Momentary
Without Lamp
1NO-1NC ALD29911N
See page 17
for lamps.
2NO ALD29920N
2NC ALD29902N
LED
1NO-1NC ALD211DN
2NO ALD220DN
2NC ALD202DN
Maintained
Without Lamp
1NO-1NC AOLD29911N
2NO AOLD29920N
2NC AOLD29902N
LED
1NO-1NC AOLD211DN
2NO AOLD220DN
2NC AOLD202DN
Color Code and Operating Voltage Code
Specify a code in place of and in the Part No.
Lens/LED Color Code Operating Voltage Code Input
Without Lamp LED
A: amber
C: clear
G: green
R: red
S: blue
W: white
DNY: yellow
A: amber
G: green
PW: pure white
R: red
S: blue
W: white
Y: yellow
66: 6V AC/DC
11: 12V AC/DC
22: 24V AC/DC
Full Voltage
16: 100/110V AC
126: 120V AC
26: 200/220V AC
246: 240V AC
386: 380V AC
46: 400/440V AC
Transformer
•Use a pure white (PW) LED for yellow (Y) illumination..
Dimensions
M3.5 Terminal
Screws
96.5 (2 blocks)
119.5 (4 blocks)
23
Panel Thickness
0.8 to 7.5
ø24.6
ø35
18.5
M3.5 Terminal Screw
ø24
ø35
9
97.5 (2 blocks)
120.5 (4 blocks)
24
Panel Thickness 0.8 to 7.5
40
ø40
63 (2 blocks)
M3 Terminal Screw M3 Terminal Screw
ø24
ø35
23
86 (4 blocks)
9
24
5.
5
Panel Thickness 0.8 to 7.5
M3.5 Terminal Screw
40
ø40
ALD2/AOLD2
Full Voltage
ALD2/AOLD2
BA9S/Transformer
All dimensions in mm.
79
ø30 Diecast Zinc Series Illuminated Pushbuttons ø30
ALFD2 / AOLFD2 Round Extended with Full Shroud Illuminated Pushbuttons
Shape Lamp
Receptacle Operation Lamp Contact Part No. Applicable
Lamp
Round Extended
with Full Shroud
ALFD2
AOLFD2
BA9S
Momentary
Without Lamp
1NO-1NC ALFD29911N
See page 17
for lamps.
2NO ALFD29920N
2NC ALFD29902N
LED
1NO-1NC ALFD211DN
2NO ALFD220DN
2NC ALFD202DN
Maintained
Without Lamp
1NO-1NC AOLFD29911N
2NO AOLFD29920N
2NC AOLFD29902N
LED
1NO-1NC AOLFD211DN
2NO AOLFD220DN
2NC AOLFD202DN
Color Code and Operating Voltage Code
Specify a code in place of and in the Part No.
Lens/LED Color Code Operating Voltage Code Input
Without Lamp LED
A: amber
C: clear
G: green
R: red
S: blue
W: white
DNY: yellow
A: amber
G: green
PW: pure white
R: red
S: blue
W: white
Y: yellow
66: 6V AC/DC
11: 12V AC/DC
22: 24V AC/DC
Full Voltage
16: 100/110V AC
126: 120V AC
26: 200/220V AC
246: 240V AC
386: 380V AC
46: 400/440V AC
Transformer
•Use a pure white (PW) LED for yellow (Y) illumination.
Dimensions
M3.5 Terminal
Screws
96.5 (2 blocks)
119.5 (4 blocks)
23
Panel Thickness
0.8 to 7.5
ø24.6
ø35
18.5
M3.5 Terminal Screw
M3 Terminal Screw
235.5
Panel Thickness 0.8 to 6
40
ø40
ø35
ø30
62 (2 blocks)
84 (4 blocks)
25
M3.5 Terminal Screw
M3 Terminal Screw
Panel Thickness 0.8 to 6
40
ø40
ø35
ø30
96.5 (2 blocks) 25
119.5 (4 blocks)
All dimensions in mm.
ALFD2/AOLFD2
Transformer
ALFD2/AOLFD2
Full Voltage
ø30
80
ø30 ø30 Diecast Zinc Series Illuminated Pushbuttons
ALD3 / AOLD3 Mushroom (ø40) Illuminated Pushbuttons
Shape Lamp
Receptacle Operation Lamp Contact Part No. Applicable
Lamp
ø40 Mushroom
ALD3
AOLD3
BA9S
Momentary
Without Lamp
1NO-1NC ALD39911DN
See page 17
for lamps.
2NO ALD39920DN
2NC ALD39902DN
LED
1NO-1NC ALD311DN
2NO ALD320DN
2NC ALD302DN
Maintained
Without Lamp
1NO-1NC AOLD39911DN
2NO AOLD39920DN
2NC AOLD39902DN
LED
1NO-1NC AOLD311DN
2NO AOLD320DN
2NC AOLD302DN
Color Code and Operating Voltage Code
Specify a code in place of and in the Part No.
Lens/LED Color Code Operating Voltage Code Input
A: amber
G: green
R: red
W: white
Y: yellow
Use a pure white (PW) LED
for yellow (Y) illumination..
66: 6V AC/DC
11: 12V AC/DC
22: 24V AC/DC
Full Voltage
16: 100/110V AC
126: 120V AC
26: 200/220V AC
246: 240V AC
386: 380V AC
46: 400/440V AC
Transformer
Dimensions
ALD3/AOLD3
Full Voltage
ALD3/AOLD3
Transformer
All dimensions in mm.
M3.5 Terminal Screw
M3 Terminal
Screw
23
86 (4 blocks)
5.5
Panel Thickness 0.8 to 7.5
ø40
24
63 (2 blocks)
M3.5 Terminal Screw
M3 Terminal Screw
97.5 (2 blocks)
120.5 (4 blocks)
Panel Thickness 0.8 to 7.5
ø40
24
40
36
40
36
M3.5 Terminal Screw
M3 Terminal
Screw
23
86 (4 blocks)
5.5
Panel Thickness 0.8 to 7.5
ø40
24
63 (2 blocks)
M3.5 Terminal Screw
M3 Terminal Screw
97.5 (2 blocks)
120.5 (4 blocks)
Panel Thickness 0.8 to 7.5
ø40
24
40
36
40
36
81
ø30 Diecast Zinc Series Illuminated Pushbuttons ø30
AVLD3/ AVLDE3 Mushroom Pushlock Turn Reset Illuminated Pushbuttons
Shape Lamp
Receptacle Lamp Contact Part No. Applicable Lamp
Mushroom Pushlock Turn
Reset
AVLD3
AVLDE3
BA9S
Without Lamp
1NO-1NC AVLD39911NR
See page 17 for
lamps.
2NO AVLD39920NR
2NC AVLD39902NR
LED
1NO-1NC AVLD311DNR
2NO AVLD320DNR
2NC AVLD302DNR
Color Code and Operating Voltage Code
Specify a code in place of and in the Part No.
Operating Voltage Code Input
66: 6V AC/DC
11: 12V AC/DC
22: 24V AC/DC
Full Voltage
16: 100/110V AC
126: 120V AC
26: 200/220V AC
246: 240V AC
386: 380V AC
46: 400/440V AC
Transformer
•Color code: R (red)
•Pushlock Turn Reset: Lens is maintained when pressed and is reset when turned clockwise. Red lens only.
Note: AVLD3 and AVLDE3 pushlock turn reset switches cannot be used as emergency stop switches. When emergency stop switches
are required, use XN or HN series emergency stop switches (ISO 13850 and IEC 60947-5-5 compliant).
Dimensions
M3.5 Terminal
Screws
96.5 (2 blocks)
119.5 (4 blocks)
23
Panel Thickness
0.8 to 7.5
ø24.6
ø35
18.5
M3.5 Terminal Screw
M3 Terminal Screw
23
97.5 (2 blocks)
120.5 (4 blocks)
5.5
Panel Thickness 0.8 to 7.5
ø40
24
M3.5 Terminal Screw
M3 Terminal Screw
23
86 (4 blocks)
5.5
Panel Thickness 0.8 to 7.5
ø40
2463 (2 blocks)
40
36
40
36
AVLD3
BA9S/Full Voltage
AVLD3
BA9S/Transformer
All dimensions in mm.
Note: When ordering 6V, 12V, 24V AC/DC units, specify
“E “ before the operating voltage code.
Example: AVLDE311NR
ø30
82
ø30 ø30 Diecast Zinc Series Selector Switches
ASD Selector Switches (Knob Operator)
No. of Positions
ASD
90° 2-position
Contact
Congu-
ration
Contact Block Operator Position Maintained Spring Return
from Right
Spring Return
from Left
Mount-
ing Posi-
tion
Con-
tact
L R L R LRL R
1NO 1NO ASD210N ASD2110N ASD2210N
2Dummy
1NO-1NC
1NO ASD211N ASD2111N ASD2211N
2NC
2NO 1NO ASD220N ASD2120N ASD2220N
2NO
2NO-2NC
1NO
ASD222N ASD2122N ASD2222N
2NC
3NO
4NC
45° 3-position
Contact
Congu-
ration
Contact Block Operator Position Maintained Spring Return
from Right
Spring Return
from Left
Spring Return
Two-way
Mount-
ing Posi-
tion
Con-
tact
L C R
C
L R
C
L R
C
L R
C
L R
2NO 1NO ASD320N ASD3120N ASD3220N ASD3320N
2NO
4NO
1NO
ASD340N ASD3140N ASD3240N ASD3340N
2NO
3NO
4NO
2NO-2NC
1NO
ASD322N ASD3122N ASD3222N ASD3322N
2NO
3NC
4NC
2NC 1NC ASD302N ASD3102N ASD3202N ASD3302N
2NC
4NC
1NC
ASD304N ASD3104N ASD3204N ASD3304N
2NC
3NC
4NC
•Knob: Black
•Round bezel (metal): Chrome-plated
•Selector switches with one contact block contain a dummy block.
•On the 2-position selector switches marked with above, the contact operation is reversed as follows.
[Example]
L C R
1NO
2NO
3NC
4NC
Center RightLeft
Operator
Position
Contact Block Mounting Position and
Contact Conguration Chart
Dimensions
2
4
1
3
M3.5 Terminal Screw
40
5.5 23
ø35
53 (1 or 2
blocks)
76
(
4 blocks)
21
ø40
90°
45°
45°
Panel Thickness 0.8 to 7.5
All dimensions in mm.
83
ø30 Diecast Zinc Series Selector Switches ø30
ASDL Selector Switches (Lever Operator)
No. of Positions
ASDL
90° 2-position
Contact
Congu-
ration
Contact Block Operator Position Maintained Spring Return
from Right
Spring Return
from Left
Mount-
ing Posi-
tion
Con-
tact
L R L R LRL R
1NO 1NO ASD2L10N ASD21L10N ASD22L10N
2Dummy
1NO-1NC
1NO ASD2L11N ASD21L11N ASD22L11N
2NC
2NO 1NO ASD2L20N ASD21L20N ASD22L20N
2NO
2NO-2NC
1NO
ASD2L22N ASD21L22N ASD22L22N
2NC
3NO
4NC
45° 3-position
Contact
Congu-
ration
Contact Block Operator Position Maintained Spring Return
from Right
Spring Return
from Left
Spring Return
Two-way
Mount-
ing Posi-
tion
Con-
tact
L C R
C
L R
C
L R
C
L R
C
L R
2NO 1NO ASD3L20N ASD31L20N ASD32L20N ASD33L20N
2NO
4NO
1NO
ASD3L40N ASD31L40N ASD32L40N ASD33L40N
2NO
3NO
4NO
2NO-2NC
1NO
ASD3L22N ASD31L22N ASD32L22N ASD33L22N
2NO
3NC
4NC
2NC 1NC ASD3L02N ASD31L02N ASD32L02N ASD33L02N
2NC
4NC
1NC
ASD3L04N ASD31L04N ASD32L04N ASD33L04N
2NC
3NC
4NC
•Lever: Black
•Round bezel (metal): Chrome-plated
•Selector switches with one contact block contain a dummy block.
•On the 2-position selector switches marked with above, the contact operation is reversed as follows.
[Example]
M3.5 Terminal Screw
40
5.5 23
ø35
53 (1 or 2
blocks)
76
(
4 blocks
)
21.5
ø40
90°
45°
45°
Panel Thickness 0.8 to 7.5
L C R
1NO
2NO
3NC
4NC
Center RightLeft
Operator
Position
Contact Block Mounting Position and
Contact Conguration Chart
Dimensions
2
4
1
3
All dimensions in mm.
ø30
84
ø30 ø30 Diecast Zinc Series Selector Switches
ASDK Key Selector Switches
No. of Positions
ASDK
90° 2-position
Contact
Congu-
ration
Contact Block Operator Position Maintained Spring Return
from Right
Spring Return
from Left
Mount-
ing Posi-
tion
Con-
tact
L R L R LRL R
1NO 1NO ASD2K10N ASD21K10N ASD22K10N
2Dummy
1NO-1NC
1NO ASD2K11N ASD21K11N ASD22K11N
2NC
2NO 1NO ASD2K20N ASD21K20N ASD22K20N
2NO
2NO-2NC
1NO
ASD2K22N ASD21K22N ASD22K22N
2NC
3NO
4NC
45° 3-position
Contact
Congu-
ration
Contact Block Operator Position Maintained Spring Return
from Right
Spring Return
from Left
Spring Return
Two-way
Mount-
ing Posi-
tion
Con-
tact
L C R
C
L R
C
L R
C
L R
C
L R
2NO 1NO ASD3K20N ASD31K20N ASD32K20N ASD33K20N
2NO
4NO
1NO
ASD3K40N ASD31K40N ASD32K40N ASD33K40N
2NO
3NO
4NO
2NO-2NC
1NO
ASD3K22N ASD31K22N ASD32K22N ASD33K22N
2NO
3NC
4NC
2NC 1NC ASD3K02N ASD31K02N ASD32K02N ASD33K02N
2NC
4NC
1NC
ASD3K04N ASD31K04N ASD32K04N ASD33K04N
2NC
3NC
4NC
•Cylinder: Black
•Round bezel (metal): Chrome-plated
•On the spring-returned, the keys can be released only from the maintained positions. On the maintained, the key can be released from
every position. Key retained positions are also available. See page 73.
•Key selector switches are supplied with two standard keys.
•Key selector switches with one contact block contain a dummy block.
•On the 2-position selector switches marked with above, the contact operation is reversed as follows.
[Example]
M3.5 Terminal Screw
40
5.5 23
ø35
53 (1 or 2
blocks)
76 (4 blocks)
ø40
9
16.5
38
90°
45°
45°
Panel Thickness 0.8 to 7.5
L C R
1NO
2NO
3NC
4NC
Center RightLeft
Operator
Position
Contact Block Mounting Position and
Contact Conguration Chart
Dimensions
2
4
1
3
All dimensions in mm.
85
ø30 Diecast Zinc Series Illuminated Selector Switches ø30
ASLD Illuminated Selector Switches
90° 2-position
ASLD (Base BA9S)
Contact
Cong-
uration
Contact
Block
Operator
Position Lamp
Maintained
L R
Spring Return
from Right
L R
Spring Return
from Left
L R
Mounting
Position
Contact
L R
1NO-1NC
1NO Without Lamp ASLD29911NASLD219911NASLD229911N∗
2NC LED ASLD211DNASLD2111DN
ASLD2211DN∗
2NO
1NO Without Lamp ASLD29920NASLD219920NASLD229920N
2NO LED ASLD220DNASLD2120DN
ASLD2220DN
2NO-2NC
1NO Without Lamp ASLD29922NASLD219922NASLD229922N
2NC
3NO LED ASLD222DNASLD2122DN
ASLD2222DN
4NC
Color Code and Operating Voltage Code
Specify a code in place of or in the Part No.
Lens/LED Color Code Operating Voltage Code Input
A: amber
G: green
R: red
S: blue
W: white
Y: yellow
Use a pure white (PW)
LED for yellow (Y) illumi-
nation.
66: 6V AC/DC
11: 12V AC/DC
22: 24V AC/DC
Full voltage
16: 100/110V AC
136: 120V AC
26: 200/220V AC
256: 240V AC
386: 380V AC
46: 400/440V AC
Transformer
•On the 2-position selector switches marked with above, the contact operation is reversed as follows.
[Example]
1
2
3
4
40
ø40
235.5
28
9
ø35
ø25
M3.5 Terminal Screws
M3 Terminal Screw
63 (2 blocks)
A: 86 (4 blocks)
B: 97.5 (2 blocks), 120.5 (4 blocks)
Panel Thickness
0.8 to 7.5
(including nameplate)
90°
45°
45°
Contact Block Mounting Position
and Contact Conguration Chart
Dimensions
All dimensions in mm.
L R
1NO
2NC
3NO
4NC
RightLeft
Operator
Position
A: Full voltage
B: Transformer
ø30
86
ø30 ø30 Diecast Zinc Series Illuminated Selector Switches
ASLD Illuminated Selector Switches
45° 3-position
Contact
Cong-
uration
Contact
Block
Operator
Position Lamp
Maintained
C
L R
Spring Return
from Right
C
L R
Spring Return
from left
C
L R
Spring Return
Two-way
C
L R
Mounting
Position
Con-
tact
L C R
2NO
1NO Without Lamp ASLD39920NASLD319920NASLD329920NASLD339920N
2NO LED ASLD320DNASLD3120DNASLD3220DNASLD3320DN
2NC
1NC Without Lamp ASLD39902NASLD319902NASLD329902NASLD339902N
2NC LED ASLD302DNASLD3102DNASLD3202DNASLD3302DN
2NO-
2NC
1NO Without Lamp ASLD39922NASLD319922NASLD329922NASLD339922N
2NO
3NC LED ASLD322DNASLD3122DNASLD3222DNASLD3322DN
4NC
4NO
1NO Without Lamp ASLD39940NASLD319940NASLD329940NASLD339940N
2NO
3NO LED ASLD340DNASLD3140DNASLD3240DNASLD3340DN
4NO
4NC
1NC Without Lamp ASLD39904NASLD319904NASLD329904NASLD339904N
2NC
3NC LED ASLD304DNASLD3104DNASLD3204DNASLD3304DN
4NC
Color Code and Operating Voltage Code
Specify a code in place of or in the Part No.
Lens/LED Color Code Operating Voltage Code Input Type
A: amber
G: green
R: red
S: blue
W: white
Y: yellow
Use a pure white (PW)
LED for yellow (Y) illumi-
nation.
66: 6V AC/DC
11: 12V AC/DC
22: 24V AC/DC
Full voltage
16: 100/110V AC
136: 120V AC
26: 200/220V AC
256: 240V AC
386: 380V AC
46: 400/440V AC
Transformer
40
ø40
235.5
28
9
ø35
ø25
M3.5 Terminal Screws
M3 Terminal Screw
63 (2 blocks)
A: 86 (4 blocks)
B: 97.5 (2 blocks), 120.5 (4 blocks)
Panel Thickness
0.8 to 7.5
(including nameplate)
90°
45°
45°
Contact Block Mounting Position
and Contact Conguration Chart
Dimensions
L C R
1NO
2NO
3NC
4NC
Center Right
Left
Operator
Position
All dimensions in mm.
1
2
3
4
A: Full voltage
B: Transformer
87
ø30 Diecast Zinc Series Selector Pushbuttons ø30
ASBD2 Ring Operator / ASBD2L Lever Operator Selector Pushbuttons
Shape
Contact
Cong-
uration
Cir-
cuit
Code
Contact
Block
Ring/Lever
Ring Operator Lever Operator
Color
Pushbutton Part No. Part No.
Mounting
Position
Con-
tact
Normal Push Normal Push
Ring Operator
(90° 2-Position)
ASBD2
Lever Operator
(90° 2-Position)
ASBD2L
1NO-1NC
A03 1NO
ASBD211N-A03ASBD2L11N-A03
B: black
G: green
R: red
Y: yellow
2NC
G03 1NO Blocked ASBD211N-G03
ASBD2L11N-G03
2NC
2NO-2NC
A08
1NO
ASBD222N-A08ASBD2L22N-A08
2NC
3NO
4NC
C10
1NO
ASBD222N-C10ASBD2L22N-C10
2NO
3NC
4NC
D10
1NO
ASBD222N-D10ASBD2L22N-D10
2NO
3NC
4NC
E10
1NO
ASBD222N-E10ASBD2L22N-E10
2NO
3NC
4NC
F10
1NO
ASBD222N-F10ASBD2L22N-F10
2NO
3NC
4NC
G10
1NO
Blocked ASBD222N-G10
ASBD2L22N-G10
2NO
3NC
4NC
•Specify a button color code in place of in the Part No.
•Ring/Lever (Metal): Chrome-plated
Notes:
1. Circuit Code G: The pushbutton does not operate when the ring or lever operator is turned to the right position.
2. Circuit Codes E and F: The right and left NC contact blocks on circuit code E or F may overlap each other while turning the ring or lever
operator. The NO and NC contact blocks on circuit code F may overlap each other while pressing the button.
3. When using the selector pushbutton, do not turn the ring or lever operator with the pushbutton depressed. Otherwise, damage or failure
may be caused.
4. When installing the lever operator, make sure that the lever is not in the horizontal position. Otherwise, shock resistance may be de-
graded.
Contact Block Mounting Position
M3.5 Terminal Screw
40
5.5 23
53 (2 blocks)
76 (4 blocks)
Panel Thickness 0.8 to 7.5
(including nameplate)
ø40
ø28
ø35
25
M3.5 Terminal Screw
M3 Setscrew
(The actual screw is
located on the opposite side)
5.5 23
53 (1 or
2 blocks)
76 (3 or 4 blocks)
Panel Thickness 0.8 to 7.5
(including nameplate)
ø34
50 20
37 37
R50
26.5
1
3
2
4
Dimensions
Ring Operator
(90° 2-position)
ASBD2
Lever Operator
(90° 2-position)
ASBD2L
ø30
Accessories (For Diecast Zinc Series Only) For other accessories, see pages 59 to 68.
Shape Material Part No. Ordering No. Package
Quantity Description
Metal Bezel
Flush
(Octagonal) Extended
(Octagonal)
Chrome-plated
OG-81 OG-81PN02 2
•Cannot be used with half-shrouds.
OG-82 OG-82 1
Spare Key
Metal TW-SK-0 TW-SK-0PN02 2•For key selector switches
Maintenance Parts (For Diecast Zinc Series Only)
Shape Specication Part No. Ordering No.
Package
Quantity
Description
Button
Flush
Extended
Polyacetal
ABN1BN-
ABN1BN-PN05 5
Specify a color code in place of .
B (black), G (green), R (red), S
(blue), W (white), Y (yellow)
•Above colors are used for ø30 di-
ecast zinc switches & pilot lights
(light colored operator units).
ABN2BN-
ABN2BN-PN05 5
ABN3BN-
ABN3BN-PN02 2
ABN4BN-
ABN4BN-
1
Specify a color code in place
of .
B (black), G (green), R (red), S
(blue), Y (yellow)
Dummy
Block Polyamide BST-D BST-DPN10 10
•Used for 1NO or 1NC contact
blocks.
•Snaps on to the operator unit.
Selector Operator
Knob
Lever

Color
Insert Polyacetal
ASNHT-ASNHT-PN02 2
Specify a color code in place of .
B (blue), G (green), R (red)
ASNHL-ASNHL-PN02
TW-HC1TW-HC1PN05 5
Specify a color code in place of .
B (black), G (green), R (red), S
(blue), W (white), Y (yellow)
Jumbo Mushroom
Mushroom
Instructions
Tightening Torque for Terminal Screws
Tighten the M3.5 terminal screws to a torque of 1.0 to 1.3 N·m.
Replacement of Lamps
Lamps can be replaced by using the lamp holder tool (OR-55) from the front
of the panel.
•How to remove
To remove, slip the lamp holder tool onto the lamp head lightly. Then push
slightly, and turn the lamp holder tool counterclockwise.
•How to install
To install, insert the lamp head into the lamp holder tool. Place the pins on
the lamp base to the grooves in the lamp socket. Inset the lamp and turn it
clockwise.
Installation of LED Illuminated Units
•When using full voltage LED illuminated units, provide protection against
electrical noise, if necessary. See page 70 for notes on LED illuminated
units.
OR-55
•Turn off the power to the ø30 diecast zinc switches & pilot lights before
starting installation, removal, wiring, maintenance, and starting installation,
removing, wiring, maintenance, and inspection of the products. Failure to turn
power off may cause electrical shocks or re hazard.
•To avoid a burn on your hand, use the lamp holder tool when replacing
lamps.
•For wiring, use wires of a proper size to meet the voltage and current
requirements. Tighten the M3.5 terminal screws to a tightening torque of 1.0
to 1.3 N·m. Failure to tighten terminal screws may cause overheat and re.
Safety Precautions
ø30 ø30 Diecast Zinc Series Accessories and Replacement Parts
www.idec.com
USA IDEC Corporation Tel:
+1-408-747-0550
opencontact@idec.com
Germany
IDEC Electrotechnik GmbH
Tel: +49-40-25 30 54 - 0 service@eu.idec.com
Singapore IDEC Izumi Asia Pte. Ltd. Tel: +65-6746-1155
info@sg.idec.com
Thailand
IDEC Asia (Thailand) Co., Ltd
Tel: +66-2-392-9765 sales@th.idec.com
Australia IDEC Australia Pty. Ltd. Tel:
+61-3-8523-5900
sales@au.idec.com
Taiwan IDEC Taiwan Corporation Tel: +886-2-2698-3929 service@tw.idec.com
Hong Kong IDEC Izumi (H.K.) Co., Ltd. Tel: +852-2803-8989
info@hk.idec.com
China/Shanghai
IDEC (Shanghai) Corporation Tel:
+
86-21-6135-1515
idec@cn.idec.com
China/Shenzhen
IDEC (Shenzhen) Corporation
Tel: +86-755-8356-2977 idec@cn.idec.com
China/Beijing IDEC (Beijing) Corporation Tel: +86-10-6581-6131 idec@cn.idec.com
Japan IDEC Corporation Tel:
+81-6-6398-2527
marketing@idec.co.jp
Specications and other descriptions in this brochure are subject to change without notice.
2017 IDEC Corporation, All Rights Reserved.
EP1429-13 JUNE 2017
Head Office