Powerware series Eaton 9130 Tower UPS Features * Protects against downtime, data loss and process interruption by providing continuous, clean power Product snapshot Product rating: 700-3000 VA Voltage 120 Vac, 208-240V Frequency: 50/60 Hz (auto-sensing) Configuration: Tower Advanced power protection for: * Offers premium performance with a 0.9 power factor and >95 percent efficiency in high efficiency mode * Increases battery service life and system uptime with ABM(R) battery charging technology * Enables prolonged runtime of essential equipment during power outages by allowing for orderly, remote shutdown of non-critical systems or processes * Conserves valuable space with a slim tower design * Ensures data and system integrity with Intelligent Power(R) Manager supervisory software, which provides easy, versatile, remote monitoring and management of multiple devices * Provides a two-year limited warranty, an extended warranty, on-site Flex and on-site PowerTrust service contracts, and a $250,000 load protection guarantee (U.S. and Canada) * IT and networking environments * Servers, networking gear * Telecommunications, VoIP, security systems * Medical systems * Diagnostics and medical screening * Patient record archives * Manufacturing systems * Chip fabrication * Pharmaceutical production * Chemical processing Maximum availability * ABM technology increases battery life and system uptime * Load segments allow for selective load shedding during outages * Optional hot-swappable extended battery modules (EBMs) extend backup runtime for hours * Internal hot-swappable batteries can be replaced without powering down the UPS * UPS startup on battery power * Optional HotSwap Maintenance Bypass (MBP) enables the entire UPS to be serviced or replaced without interrupting power to loads Low total cost of ownership * More real output power for dollar spent with 0.9 power factor * Cuts energy usage and costs with >95% efficiency rating in high efficiency mode UPS status and operation Communications * A standard communication slot accepts interfaces for Web, SNMP, Modbus or serial connectivity * Bright, front panel LCD for easy monitoring and management * Connect directly to the Ethernet network and the Internet to monitor and manage the UPS with a standard Web browser * LEDs to show system status * Optional FlexPDU adds more plug-and-play flexibility, streamlining power distribution Bright LCD user interface * Multiple options for industrystandard communications * Intelligent Power Manager supervisory software included free of charge * Free NetWatch 5.0 software enables automatic shutdown of UPS-protected devices, including virtualized servers * Direct monitoring via existing management systems and LANs * Monitor power conditions in real time through existing facilities or building management system * Monitor and gracefully shut down multiple servers running various operating systems * Receive alarm notifications from the UPS, environmental monitoring devices or security systems For more information on the 9130, please visit www.eaton.com/9130 or call 800.356.5794. Add up to four EBMs for hours of runtime Eaton NetWatch Client 5.0 has tested compatible with Cisco Unified Communications Manager 4.3. Go to www.eaton.com/PQ/cisco for disclaimer. Extended battery module connection Communication bay Optional FlexPDU and HotSwap MBP for greater flexibility and uptime Standard relay output contact RS-232 port Remote Emergency Power Off (REPO) USB port Line cord with 5-15P Two individually controlled load segments UPS rear panel (PW9130L1500T-XL) 2 EATON CORPORATION Eaton 9130 Tower UPS Battery runtimes (in minutes) Load Internal w/1 w/2 w/3 (VA/Watts) batteries EBM EBMs EBMs PW9130L700T 700/490 8 N/A N/A N/A 525/368 12 N/A N/A N/A 350/245 21 N/A N/A N/A 175/123 37 N/A N/A N/A PW9130i700T 700/490 8 N/A N/A N/A 525/368 12 N/A N/A N/A 350/245 19 N/A N/A N/A 175/123 35 N/A N/A N/A PW9130L1000T-XL 1000/700 10 40 73 108 750/525 13 58 101 152 500/350 24 85 172 249 250/175 48 190 310 451 PW9130G1000T-XL / XLEU / PW9130i1000T-XL 1000/700 10 40 78 110 750/525 13 55 103 151 500/350 22 82 186 250 250/175 47 190 328 431 PW9130L1500T-XL 1500/1050 7 34 63 88 1125/788 11 44 84 129 750/525 18 79 148 207 375/263 38 167 278 475 w/4 EBMs N/A N/A N/A N/A N/A N/A N/A N/A 149 219 304 569 150 223 312 584 135 210 267 540 Load Internal w/1 w/2 w/3 (VA/Watts) batteries EBM EBMs EBMs PW9130i1500T-XL 1500/1050 7 32 61 98 1125/788 11 47 83 126 750/525 18 81 143 208 375/263 38 171 298 416 PW9130L2000T-XL 2000/1400 15 61 111 156 1500/1050 21 81 145 184 1000/700 34 129 198 293 500/350 72 225 449 590 PW9130G2000T-XL / XLEU / PW9130i2000T-XL 2000/1400 15 61 111 156 1500/1050 21 81 145 184 1000/700 34 129 198 293 500/350 72 225 449 590 PW9130L3000T-XL 3000/2100 9 35 66 95 2250/1575 13 53 100 139 1500/1050 22 86 153 221 750/525 69 168 298 395 PW9130G3000T-XL / XLEU / PW9130i3000T-XL 3000/2100 9 36 68 101 2250/1575 12 49 90 134 1500/1050 20 79 143 180 750/525 46 161 267 434 w/4 EBMs 128 195 262 564 194 269 410 766 186 248 431 840 132 183 267 545 137 165 240 547 Notes: Backup times are approximate and may vary with equipment, configuration, battery age, temperature, etc. Runtimes are shown at a 0.7 power factor. 9130 models Catalog number Style number North American models: 120V, 50/60 Hz PW9130L700T 103006426-6591 PW9130L1000T-XL 103006427-6591 PW9130L1500T-XL 103006428-6591 PW9130L2000T-XL 103006429-6591 PW9130L3000T-XL 103006430-6591 Global models: 208V, 50/60 Hz PW9130G1000T-XL 103006431-6591 PW9130G2000T-XL 103006432-6591 PW9130G3000T-XL 103006446-6591 Rating Input Output Dimensions (VA/Watts) connection1 receptacles H x W x D, in (mm) 700/630 5-15P (6) 5-15R 9.1 x 6.3 x 13.8 (230 x 160 x 350) 1000/900 5-15P (6) 5-15R 9.1 x 6.3 x 15.0 (230 x 160 x 380) 1500/1350 5-15P (6) 5-15R 9.1 x 6.3 x 16.9 (230 x 160 x 430) 2000/1800 5-20P (1) L5-20R, (4) 5-20R 12.8 x 8.4 x 16.1 (325 x 214 x 410) 3000/2700 L5-30P (4) 5-20R, (1) L5-30R 12.8 x 8.4 x 16.1 (325 x 214 x 410) 1000/900 L6-20P2 (1) L6-20R, (2) 6-20R 9.1 x 6.3 x 15.0 (230 x 160 x 380) 2000/1800 L6-20P2 (1) L6-20R, (4) 6-20R 12.8 x 8.4 x 16.1 (325 x 214 x 410) 3000/2700 L6-20P3 (1) L6-30R, (1) L6-20R, 12.8 x 8.4 x 16.1 (325 x 214 x 410) (2) 6-20R PW9130G1000T-XLEU 103006477-6591 1000/900 L6-20P2 (6) C13 9.1 x 6.3 x 15.0 (230 x 160 x 380) PW9130G2000T-XLEU 103006478-6591 2000/1800 L6-20P2 (8) C13, (1) C19 12.8 x 8.4 x 16.1 (325 x 214 x 410) PW9130G3000T-XLEU 103006479-6591 3000/2700 L6-20P3 (8) C13, (1) C19 12.8 x 8.4 x 16.1 (325 x 214 x 410) International models: 230V, 50/60 Hz PW9130i700T 103006433-6591 700/630 C14 (6) C13 9.1 x 6.3 x 13.8 (230 x 160 x 350) PW9130i1000T-XL 103006434-6591 1000/900 C14 (6) C13 9.1 x 6.3 x 15.0 (230 x 160 x 380) PW9130i1500T-XL 103006435-6591 1500/1350 C14 (6) C13 9.1 x 6.3 x 16.9 (230 x 160 x 430) PW9130i2000T-XL 103006436-6591 2000/1800 C14 (8) C13, (1) C19 12.8 x 8.4 x 16.1 (325 x 214 x 410) PW9130i3000T-XL 103006437-6591 3000/2700 C20 (8) C13, (1) C19 12.8 x 8.4 x 16.1 (325 x 214 x 410) Extended battery modules PW9130N1000T-EBM4 103006438-6591 NA NA NA 9.1 x 6.3 x 15.0 (230 x 160 x 380) PW9130N1500T-EBM5 103006439-6591 NA NA NA 9.1 x 6.3 x 16.9 (230 x 160 x 430) PW9130N3000T-EBM6 103006440-6591 NA NA NA 12.8 x 8.4 x 16.1 (325 x 214 x 410) 1 Input cord length is 6 ft C14, w/detachable L6-20P 3 C20, w/detachable L6-20P 4 This EBM works with 1000 VA model, where available 5 This EBM works with 1500 VA model 6 This EBM works with 2000/2500/3000 VA models, where available Weight, lb (kg) 26.9 (12.2) 32.0 (14.5) 41.9 (19.0) 76.1 (34.5) 76.1 (34.5) 32.0 (14.5) 76.1 (34.5) 76.1 (34.5) 32.0 (14.5) 76.1 (34.5) 76.1 (34.5) 26.9 (12.2) 32.0 (14.5) 41.9 (19.0) 76.1 (34.5) 76.1 (34.5) 40.8 (18.5) 53.6 (24.3) 110.3 (50.0) 2 Additional notes: Comprehensive Eaton services available for 9130 Tower products * Warranty+ extended warranties--3 or 5 years total * On-site service plans for startups and preventive and corrective maintenance Visit www.eaton.com/9130 for details. When high voltage 9130 is used at 208V, derate power by 10% and 20% at 200V When low voltage 9130 is used at 110V, derate power by 10% and 20% at 100V www.eaton.com/powerquality 1.800.356.5794 3 Technical specifications 1 General User interface LEDs Topology Diagnostics UPS bypass Dimensions Remote Emergency Power-off (REPO) Graphical LCD with blue backlight and text in English, French, German, Russian and Spanish Four status-indicating LEDs True online, double-conversion Full system self-test Automatic bypass See models table Emergency shutdown control through the REPO port Electrical input Nominal voltage Voltage range 120V, 208V, 220-240V 120V: 90-138 Vac 208/230V: 160-276 Vac Power draw 700: 5.8A @120V, 3.4A @208V, 3.0A @230V of UPS 1000: 8.3A @120V, 4.8A @208V, 4.3A @230V 1500: 12.5A @120V, 7.2A @208V, 6.5A @230V 2000: 16.6A @120V, 9.6A @208V, 8.7A @230V 3000: 14.4A @208V, 13.0A @230V Dedicated circuit 120V: breaker rating 700-1500 VA: 15A 2000 VA: 20A 3000 VA: 30A 208/230V: 700-2000 VA: 10A 3000 VA: 16A Frequency 50/60 Hz Frequency range 45-65 Hz Electrical output Power factor On utility voltage regulation On battery voltage regulation Efficiency Frequency regulation Load crest factor Voltage waveform Load segments Battery Battery type Battery runtime Battery replacement Start-on-battery Communications Serial port RS-232 standard, for interface to power management software USB port HID standard, for communicating with Windows 98, XP, ME and Vista computers Relay output Common alarm standard Communications Optional communication slots (BD Slot, Mini-Slot) slot Optional SNMP/Web card for direct control and monitoring communication in SNMP-based networks, monitoring of UPS status cards and meters through Web browser interface Relay card for integration to industrial environment and building management systems, remote shutdown for IBM AS/400 systems Environmental Safety markings EMC markings 120/208V: UL, CUL, VCCI 230V: CE, GS 120V: FCC Class B, EN55022 Class B (1.5 kVA and below); FCC Class A, EN55022 Class A (2.0 kVA and above) 230V: CE (per IEC/EN62040-2: Emissions, Category C1; Immunity, Category C2) <50 dB 0C (32F) to +40C (104F) Audible noise Ambient operating temperature Storage -20C (-4F) to +40C (104F) with batteries and temperature -25C (-13F) to +55C (131 F) without batteries Relative humidity 5-90% non-condensing Heat dissipation for all voltages: 208-240V and 120V 0.9 3% of nominal 9130 model Normal mode, BTUs/hr On battery, BTUs/hr 3% of nominal 700 VA 350 554 1000 VA 500 674 1500 VA 750 1,011 2000 VA 838 1,348 3000 VA 1,257 1,755 >95% in high-efficiency mode; >86% in online mode 3% Hz online 3 to 1 Sine wave Two configurable, individually controlled receptacles VRLA 12V/9 Ah (both internal and external) >3 minutes with internal batteries @100% load Hot-swappable internal and external batteries Allows start of UPS without utility input UNITED STATES 8609 Six Forks Road Raleigh, NC 27615 U.S.A. Toll Free: 1.800.356.5794 www.eaton.com/powerquality Canada Ontario: 416.798.0112 Toll free: 1.800.461.9166 LATIN AMERICA Argentina: 54.11.4124.4000 Brazil: 55.11.3616.8500 Caribbean: 1.949.452.9610 Mexico & Central America: 52.55.9000.5252 South Cone: 54.11.4343.6323 1 Due to continuing product improvement programs, specifications are subject to change without notice. The 9130 is part of the UPSgrade program UPSgradeTM www.eaton.com/UPSgrade Europe/Middle East/Africa Denmark: 45.3686.7910 Finland: 358.94.52.661 France: 33.1.6012.7400 Germany: 49.0.7841.604.0 Italy: 39.02.66.04.05.40 Norway: 47.23.03.65.50 Portugal: 55.11.3616.8500 Sweden: 46.8.598.940.00 United Kingdom: 44.1753.608.700 Asia Pacific Australia: 61.2.9693.9366 New Zealand: 64.0.3.343.3314 China: 86.21.6361.5599 HK/Korea/Taiwan: 852.2745.6682 India: 91.11.4223.2300 Singapore/SEA: 65.6825.1668 Eaton, Powerware, ABM, Intelligent Power, UPSgrade and PowerChain Management are trade names, trademarks and/or service marks of Eaton Corporation or its subsidiaries and affiliates. All other trademarks are property of their respective owners. (c) 2009 Eaton Corporation All Rights Reserved Printed in USA 9130TFXA July 2009