E Ericsson Internal PRODUCT TABLE OF CONTENTS SPECIFICATION Prepared (also subject responsible if other) ESLUOAN SEC/S ESLUOAN Approved PMR 8000 PMR 8000 series PoL series Regulator EAB/FAC/P SEC/D (Julia[Susanne You) Eriksson] 1 (1) (4) No. Checked Input 8 - 14 V, Input V, Output Output up up to to 40 A A // 210 W W 1/1301-BMR 00152-bmr6298210 629Technical 8210 UenUen Specification Date 2009-8-21 2009-09-01 Rev Reference A F A F EN/LZT 146 EN/LZT 146 411 411 R1C R1B March November 20132009 (c) Ericsson AB Key Features * * * * * * Industry standard POLATM compatible 38.61 x 25.91 x 9.64 mm (1.52 x 1.02 x 0.38 in.) High efficiency, up to. 96% Auto TrackTM sequencing pin Turbo TransTM Technology for Ultra-Fast Transient Parallel Operation General Characteristics * Operating temperature: -40C to 85C * Output over current protection (Non-latching, AutoReset) * Output short-circuit protection * Input under voltage protection * Over temperature protection * Wide output voltage adjust function * 1.5% total output voltage variation * Remote sense * On/Off inhibit control * Start up into a pre-biased output * Highly automated manufacturing ensures quality * ISO 9001/14001 certified supplier Safety Approvals Design for Environment E210157 Meets requirements in hightemperature lead-free soldering processes. Contents Ordering Information General Information Safety Specification Absolute Maximum Ratings ............................................................. 2 ............................................................. 2 ............................................................. 2 ............................................................. 4 Electrical Specification 3.3V, 40A / 132W 5V, 40A / 200W PMR 8210 P ......................................... 5 PMR 8210 P ......................................... 7 EMC Specification Operating Information Thermal Consideration Connections Mechanical Information Soldering Information Delivery Information Product Qualification Specification ............................................................. 9 ............................................................. 9 ........................................................... 14 ........................................................... 14 ........................................................... 1 ........................................................... ........................................................... ........................................................... 2 E Ericsson Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) 2 (4) No. 1/1301-BMR 629Technical 8210 Uen Specification ESLUOAN Approved PMR 8000 PMR 8000 series PoL Regulator series SEC/D (Julia You) Checked Date 2009-8-21 Input 8 - 14 V, Input V, Output Output up up to to 40 A A // 210 W W - Output 3-5.25 V, 40 A / 210 W Product number and Packaging PMR 8210 n1n2 Options Mounting n1 Reference A A 2 2 EN/LZT 146 EN/LZT 146 411 411 R1C R1B March November 20132009 (c) Ericsson AB Ordering Information Product program PMR 8210 Rev n2 Delivery package information Options Description n1 P S SR Through hole Surface mount (SMD pin) SMD pin with lead-free surface n2 /B /C Tray Tape and Reel Example: a lead-free through hole pin, tray packaged product would be PMR 8210 P /B. solder the die in semiconductor packages) Lead in glass of electronics components and in electronic ceramic parts (e.g. fill material in chip resistors) Lead as an alloying element in copper alloy containing up to 4% lead by weight (used in connection pins made of Brass) Quality Statement The products are designed and manufactured in an industrial environment where quality systems and methods like ISO 9000, 6 (sigma), and SPC are intensively in use to boost the continuous improvements strategy. Infant mortality or early failures in the products are screened out and they are subjected to an ATE-based final test. Conservative design rules, design reviews and product qualifications, plus the high competence of an engaged work force, contribute to the high quality of our products. Warranty Warranty period and conditions are defined in Ericsson Power Modules General Terms and Conditions of Sale. General Information Reliability Limitation of Liability The Mean Time Between Failure (MTBF) is calculated at full output power and an operating ambient temperature (TA) of +40C, which is a typical condition in Information and Communication Technology (ICT) equipment. Different methods could be used to calculate the predicted MTBF and failure rate which may give different results. Ericsson Power Modules currently uses Telcordia SR332. Ericsson Power Modules does not make any other warranties, expressed or implied including any warranty of merchantability or fitness for a particular purpose (including, but not limited to, use in life support applications, where malfunctions of product can cause injury to a person's health or life). Predicted MTBF for the series is: 1.5 million hours according to Telcordia SR332, issue 1, Black box technique. The information and specifications in this technical specification is believed to be correct at the time of publication. However, no liability is accepted for inaccuracies, printing errors or for any consequences thereof. Ericsson AB reserves the right to change the contents of this technical specification at any time without prior notice. Telcordia SR332 is a commonly used standard method intended for reliability calculations in ICT equipment. The parts count procedure used in this method was originally modelled on the methods from MIL-HDBK-217F, Reliability Predictions of Electronic Equipment. It assumes that no reliability data is available on the actual units and devices for which the predictions are to be made, i.e. all predictions are based on generic reliability parameters. Compatibility with RoHS requirements The products are compatible with the relevant clauses and requirements of the RoHS directive 2002/95/EC and have a maximum concentration value of 0.1% by weight in homogeneous materials for lead, mercury, hexavalent chromium, PBB and PBDE and of 0.01% by weight in homogeneous materials for cadmium. Exemptions in the RoHS directive utilized in Ericsson Power Modules products include: Lead in high melting temperature type solder (used to (c) Ericsson AB 2009 Safety Specification General information Ericsson Power Modules DC/DC converters and DC/DC regulators are designed in accordance with safety standards IEC/EN/UL60950, Safety of Information Technology Equipment. IEC/EN/UL60950 contains requirements to prevent injury or damage due to the following hazards: * * * * * * Electrical shock Energy hazards Fire Mechanical and heat hazards Radiation hazards Chemical hazards E Ericsson Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) ESLUOAN Approved PMR 8000 PMR 8000 series PoL Regulator series SEC/D (Julia You) Checked Input 8 - 14 V, Input V, Output Output up up to to 40 A A // 210 W W On-board DC-DC converters and DC/DC regulators are defined as component power supplies. As components they cannot fully comply with the provisions of any Safety requirements without "Conditions of Acceptability". Clearance between conductors and between conductive parts of the component power supply and conductors on the board in the final product must meet the applicable Safety requirements. Certain conditions of acceptability apply for component power supplies with limited stand-off (see Mechanical Information for further information). It is the responsibility of the installer to ensure that the final product housing these components complies with the requirements of all applicable Safety standards and Directives for the final product. Component power supplies for general use should comply with the requirements in IEC60950, EN60950 and UL60950 "Safety of information technology equipment". There are other more product related standards, e.g. IEEE802.3af "Ethernet LAN/MAN Data terminal equipment power", and ETS300132-2 "Power supply interface at the input to telecommunications equipment; part 2: DC", but all of these standards are based on IEC/EN/UL60950 with regards to safety. Ericsson Power Modules DC/DC converters and DC/DC regulators are UL60950 recognized and certified in accordance with EN60950. The flammability rating for all construction parts of the products meets requirements for V-0 class material according to IEC 60695-11-10. The products should be installed in the end-use equipment, in accordance with the requirements of the ultimate application. Normally the output of the DC/DC converter is considered as SELV (Safety Extra Low Voltage) and the input source must be isolated by minimum Double or Reinforced Insulation from the primary circuit (AC mains) in accordance with IEC/EN/UL60950. Isolated DC/DC converters It is recommended that a slow blow fuse with a rating twice the maximum input current per selected product be used at the input of each DC/DC converter. If an input filter is used in the circuit the fuse should be placed in front of the input filter. In the rare event of a component problem in the input filter or in the DC/DC converter that imposes a short circuit on the input source, this fuse will provide the following functions: * * 3 (4) No. Isolate the faulty DC/DC converter from the input power source so as not to affect the operation of other parts of the system. Protect the distribution wiring from excessive current and power loss thus preventing hazardous overheating. 1/1301-BMR 629Technical 8210 Uen Specification Date 2009-8-21 Rev Reference A A 3 3 EN/LZT 146 EN/LZT 146 411 411 R1C R1B March November 20132009 (c) Ericsson AB The galvanic isolation is verified in an electric strength test. The test voltage (Viso) between input and output is 1500 Vdc or 2250 Vdc for 60 seconds (refer to product specification). Leakage current is less than 1 A at nominal input voltage. 24 V DC systems The input voltage to the DC/DC converter is SELV (Safety Extra Low Voltage) and the output remains SELV under normal and abnormal operating conditions. 48 and 60 V DC systems If the input voltage to the DC/DC converter is 75 Vdc or less, then the output remains SELV (Safety Extra Low Voltage) under normal and abnormal operating conditions. Single fault testing in the input power supply circuit should be performed with the DC/DC converter connected to demonstrate that the input voltage does not exceed 75 Vdc. If the input power source circuit is a DC power system, the source may be treated as a TNV2 circuit and testing has demonstrated compliance with SELV limits and isolation requirements equivalent to Basic Insulation in accordance with IEC/EN/UL60950. Non-isolated DC/DC regulators The input voltage to the DC/DC regulator is SELV (Safety Extra Low Voltage) and the output remains SELV under normal and abnormal operating conditions. E Ericsson Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) 1 (6) No. Approved 4 4 2/1301-BMR 629Technical 8210 Uen Specification ECOCOLO Checked Date PMR 8000 PMR 8000 series series PoL Regulator EJANLLI Input 8 - 14 V, Input V, Output Output up up to to 40 A A // 210 W W Rev Reference EN/LZT 146 EN/LZT 146 411 411 R1C R1B March November 20132009 2009-08-31 B (c) Ericsson AB Absolute Maximum Ratings Characteristics min Tref Operating Temperature (see Thermal Consideration section) -40 TS Storage temperature -40 VI Input voltage VRC Remote Control pin voltage (see Operating Information section) Vadj Adjust pin voltage (see Operating Information section) 8 Positive logic option Negative logic option -0.2 typ 12 max Unit 85 C 125 C 14 V Open V N/A N/A V N/A N/A V Stress in excess of Absolute Maximum Ratings may cause permanent damage. Absolute Maximum Ratings, sometimes referred to as no destruction limits, are normally tested with one parameter at a time exceeding the limits in the Electrical Specification. If exposed to stress above these limits, function and performance may degrade in an unspecified manner. Fundamental Circuit Diagram +VSEN 3 VIN 2 1 2 VOUT 1 3 1 2 GND -VSEN Auto Track PWM Controller TRK ADJ Error Amplifier Ref Turbo Trans Sm artSync SYNC GND GND GND Turbo Trans UVLO Prog Block INH/UVLO RC Block GND E Ericsson Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) 2 (6) No. ECOCOLO Approved Checked PMR 8000 PMR 8000 series series PoL Regulator EJANLLI Input 8 - 14 V, Input V, Output Output up up to to 40 A A // 210 W W 5 5 2/1301-BMR 629Technical 8210 Uen Specification Date Rev Reference EN/LZT 146 EN/LZT 146 411 411 R1C R1B March November 20132009 2009-08-31 B (c) Ericsson AB 3.3V, 40A / 132W Electrical Specification PMR 8210 TP1 = -40 to +85C, VI = 8 to 14 V, RSET = 34.0 k, unless otherwise specified under Conditions. Typical values given at: Tref = +25C, VI= 12 V, max IO, unless otherwise specified under Conditions. Additional Cin = 1000+22 F and Cout = 1000 F. See Operating Information section for selection of capacitor types. Connect the sense pin, where available, to the output pin. Characteristics VI Conditions Input voltage range min typ 8 VIoff Turn-off input voltage Decreasing input voltage 6.7 VIon Turn-on input voltage Increasing input voltage 7.2 CI Internal input capacitance PO Output power Efficiency Pd Power Dissipation max Unit 14 V 8.0 V V F 44 0 132 50 % of max IO 93.6 max IO 93.4 max IO 9.5 W % 11.5 W Pli Input idling power IO= 0 A, VI = 12 V 2.0 W PRC Input standby power VI = 12 V (turned off with RC) 0.2 W IS Static Input current VI = 12 V, max IO 11.7 A fs Switching frequency 0-100 % of max IO, see Note 1 600 kHz VOi Output voltage initial setting and accuracy TP1 = +25C, VI = 12 V, max IO Output voltage tolerance band 0-100 % of max IO Idling voltage IO = 0 A Line regulation max IO Load regulation VI = 12 V, 0-100 % of max IO Vtr Load transient voltage deviation ttr Load transient recovery time Vtr Load transient voltage deviation ttr Load transient recovery time VI = 12 V, Load step 50-100-50 % of max IO, di/dt = 2.5 A/s Without TruboTrans, Cout = 1000 F, Type C see Note 2 VI = 12 V, Load step 50-100-50 % of max IO, di/dt = 2.5 A/s With TruboTrans, Cout = 5000 F, Type C, RTT=SHORT, see Note 2 VO ts tf 3.267 3.333 V 3.25 3.35 V 3.296 3.306 V 5 10 mV 5 10 mV Start-up time (from VI connection to 90 % of VOi) 3.300 135 mV 200 s 35 mV 400 s 13.2 ms VI shut-down fall time. (From VI off to 10 % of VO) max IO 740 s IO =0.4A 50.9 ms RC start-up time max IO 12.5 ms max IO 310 s Io = 0.4 A 24.5 ms {tRC tInh} RC shut-down fall time (From RC off to 10 % of VO) IO Output current Ilim Current limit threshold TP1 < max TP1 80 A Isc Short circuit current TP1 = 25C, see Note 3 92 A Cout Recommended Capacitive Load TP1 = 25C, see Note 4 Output ripple & noise See ripple & noise section, max IO VOac 0 40 1000 10000 20 A F mVp-p Note 1: Frequency may be adjusted with SmartSync pin. See Operating Information section Note 2: See Operating Information section for TurboTrans technology Note 3: Describe short circuit current characteristic, i.e. fold-back, hiccup or RMS, in one short sentence or type only "See Operating Information section.") Note 4: 1000 F of external non-ceramic output capacitance is required for basic operation. Adding additional capacitance at the load further improves transient response. Up to 1000 F of ceramic capacitance may be added in addition to the required non-ceramic capacitance. When not using TurboTrans technology, 8000 F capacitance is allowed; When using TurboTrans technology, up to 10000 F capacitance is allowed. For more information, see Operating Information Section. E Ericsson Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) 3 (6) No. Approved 6 6 2/1301-BMR 629Technical 8210 Uen Specification ECOCOLO Checked Date PMR 8000 PMR 8000 series series PoL Regulator EJANLLI Input 8 - 14 V, Input V, Output Output up up to to 40 A A // 210 W W Rev Reference EN/LZT 146 EN/LZT 146 411 411 R1C R1B March November 20132009 2009-08-31 B (c) Ericsson AB 3.3V, 40A /132W Typical Characteristics PMR 8210 Efficiency Power Dissipation [W] 10 [%] 100 8 95 6 90 8.0 V 85 8.0 V 4 12.0 V 12.0 V 14.0 V 2 80 14.0 V 0 75 0 5 10 15 20 25 30 35 0 40 [A] 5 10 15 20 25 30 35 40 [A ] Dissipated power vs. load current and input voltage at TP1 = +25C Efficiency vs. load current and input voltage at TP1 = +25C Output Characteristics Output Current Derating [V] [A] 50 3.45 40 2.0 m/s 30 1.0 m/s 20 0.5 m/s 3.40 8.0 V 3.35 12.0 V 14.0 V 3.30 10 Nat. Conv. 0 0 20 40 60 80 100 3.25 0 120 [C] Available load current vs. ambient air temperature and airflow at VI = 12 V. See Thermal Consideration section. Output Ripple & Noise 5 10 15 20 25 30 [A] Output voltage vs. load current at TP1 = +25C Output Voltage Adjust (see operating information) Passive adjust The resistor value for an adjusted output voltage is calculated by using the equations in the operating information. R SET = V - 0.7 O 30.1 Output voltage ripple at: TP1 = +25C, VI = 12 V, IO = 40 A resistive load. Trace: output voltage (5 mV/div.). Time scale: (2 s/div.). ( ) 0.7 - 8.25 k - 0.7 10 E Ericsson Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) 4 (6) No. ECOCOLO Approved Checked PMR 8000 PMR 8000 series series PoL Regulator EJANLLI Input 8 - 14 V, Input V, Output Output up up to to 40 A A // 210 W W 7 7 2/1301-BMR 629Technical 8210 Uen Specification Date Rev Reference EN/LZT 146 EN/LZT 146 411 411 R1C R1B March November 20132009 2009-08-31 B (c) Ericsson AB 5V, 40A / 200W Electrical Specification PMR 8210 TP1 = -40 to +85C, VI = 8 to 14 V, RSET = 1.37 k, unless otherwise specified under Conditions. Typical values given at: Tref = +25C, VI= 12 V, max IO, unless otherwise specified under Conditions. Additional Cin = 1000+22 F and Cout = 1000 F. See Operating Information section for selection of capacitor types. Connect the sense pin, where available, to the output pin. Characteristics VI Conditions Input voltage range min typ 8 VIoff Turn-off input voltage Decreasing input voltage 6.7 VIon Turn-on input voltage Increasing input voltage 7.2 CI Internal input capacitance PO Output power Efficiency Pd Power Dissipation max Unit 14 V 8.0 V V F 44 0 200 50 % of max IO 95.6 max IO 95.5 max IO 9.5 W % 11.5 W Pli Input idling power IO= 0 A, VI = 12 V 2.4 W PRC Input standby power VI = 12 V (turned off with RC) 0.2 W IS Static Input current VI = 12 V, max IO 17.4 A fs Switching frequency 0-100 % of max IO, see Note 1 600 kHz VOi Output voltage initial setting and accuracy TP1 = +25C, VI = 12 V, max IO Output voltage tolerance band 0-100 % of max IO Idling voltage IO = 0 A Line regulation max IO Load regulation VI = 12 V, 0-100 % of max IO Vtr Load transient voltage deviation ttr Load transient recovery time VI = 12 V, Load step 50-100-50 % of max IO, di/dt = 2.5 A/s Without TruboTrans, Cout = 1000 F, Type C Vtr Load transient voltage deviation ttr Load transient recovery time VO ts tf 4.950 5.050 V 4.85 5.15 V 4.998 5.008 V 5 10 mV 5 10 mV VI = 12 V, Load step 50-100-50 % of max IO, di/dt = 2.5 A/s With TruboTrans, Cout = 5000 F, Type C, RTT=SHORT Start-up time (from VI connection to 90 % of VOi) 5.0 135 mV 200 s 35 mV 400 s 13.1 ms VI shut-down fall time. (From VI off to 10 % of VO) max IO 630 s IO =0.4A 51.8 ms RC start-up time max IO 12.6 ms {tRC tInh} RC shut-down fall time (From RC off to 10 % of VO) max IO 425 s Io = 0.4 A 35.2 ms IO Output current Ilim Current limit threshold 0 Isc Short circuit current TP1 = 25C, {see Note 3} Cout Recommended Capacitive Load TP1 = 25C, {see Note 4} VOac Output ripple & noise See ripple & noise section, max IO TP1 < max TP1 40 80 90 1000 A 10000 20 A A F mVp-p Note 1: Frequency may be adjusted with SmartSync pin. See Operating Information section Note 2: See Operating Information section for TurboTrans technology Note 3: Describe short circuit current characteristic, i.e. fold-back, hiccup or RMS, in one short sentence or type only "See Operating Information section.") Note 4: 1000 F of external non-ceramic output capacitance is required for basic operation. Adding additional capacitance at the load further improves transient response. Up to 1000 F of ceramic capacitance may be added in addition to the required non-ceramic capacitance. When not using TurboTrans technology, 8000 F capacitance is allowed; When using TurboTrans technology, up to 10000 F capacitance is allowed. For more information, see Operating Information Section. E Ericsson Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) 5 (6) No. ECOCOLO Approved Checked PMR 8000 PMR 8000 series series PoL Regulator EJANLLI Input 8 - 14 V, Input V, Output Output up up to to 40 A A // 210 W W 8 8 2/1301-BMR 629Technical 8210 Uen Specification Date Rev Reference EN/LZT 146 EN/LZT 146 411 411 R1C R1B March November 20132009 2009-08-31 B (c) Ericsson AB 5V, 40A /200W Typical Characteristics PMR 8210 Efficiency Power Dissipation [%] [W] 10 100 8 95 6 90 8.0 85 12.0 V 80 14.0 V 8.0 V 4 12.0 V 14.0 V 2 75 0 0 5 10 15 20 25 30 35 40 [A] 0 5 10 15 20 25 30 35 40 [A] Dissipated power vs. load current and input voltage at TP1 = +25C Efficiency vs. load current and input voltage at TP1 = +25C Output Characteristics Output Current Derating [V] [A] 50 5.15 2.0 m/s 40 1.0 m/s 5.10 8.0 V 30 0.5 m/s 20 5.05 12.0 V 14.0 V Nat. Conv. 10 5.00 4.95 0 0 20 40 60 80 100 0 120 [C] Available load current vs. ambient air temperature and airflow at VI = 12 V. See Thermal Consideration section. Output Ripple & Noise 5 10 15 20 25 30 [A] Output voltage vs. load current at TP1 = +25C Output Voltage Adjust (see operating information) Passive adjust The resistor value for an adjusted output voltage is calculated by using the equations in the operating information. R SET = V - 0.7 O 30.1 Output voltage ripple at: TP1 = +25C, VI = 12 V, IO = 40 A resistive load. Trace: output voltage (5 mV/div.). Time scale: (2 s/div.). ( ) 0.7 - 8.25 k - 0.7 10 E Ericsson Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) EMQTUWX Approved 1 (10) No. Checked PMR 8000 series PoL Regulator EMAOLII Input 8 - 14 V, Output up to 40 A / 210 W EMC Specification Conducted EMI measured according to test set-up. The fundamental switching frequency is 600 kHz for PMR 8210 @ VI = 12 V, max IO. 3/1301-BMR 629Technical 8210 Uen Specification Date Rev 2012-09-26 9 Reference EN/LZT 146 411 R1C March 2013 D (c) Ericsson AB Output ripple and noise Output ripple and noise measured according to figure below. See Design Note 022 for detailed information. Conducted EMI Input terminal value (typ) TBD Output ripple and noise test setup EMI without filter Operating information Extended information for POLA products is found in Application Note 205. Input Voltage The input voltage range 8 to 14 Vdc makes the product easy to use in intermediate bus applications when powered by a non-regulated bus converter or a regulated bus converter. Turn-off Input Voltage The products monitor the input voltage and will turn on and turn off at predetermined levels. The typical hysteresis between turn on and turn off input voltage is 0.5V. Test set-up Layout recommendations The radiated EMI performance of the product will depend on the PCB layout and ground layer design. It is also important to consider the stand-off of the product. If a ground layer is used, it should be connected to the output of the product and the equipment ground or chassis. A ground layer will increase the stray capacitance in the PCB and improve the high frequency EMC performance. Turn on/off voltage can be adjusted by using UVLO (Undervoltage lockout) function. The UVLO character is defined by the ON threshold (VTHD) voltage. Below the ON threshold, the Inhibit control is overridden, and the module does not produce an output. The UVLO feature allows for limited adjustment of the ON threshold voltage. It is made by using a single resistor between the Inhibit/UVLO pin (pin 21) and ground pins (pin 8,9,12,13). The VTHD value can be adjusted from 8.0V to 11V. Default value of VTHD is 7.2V. Below equation determines the value of resistor required to adjust VTHD to a new value. R UVLO = 250 k VTHD - 7.3 E Ericsson Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) EMQTUWX Approved 2 (10) No. Checked PMR 8000 series PoL Regulator EMAOLII Input 8 - 14 V, Output up to 40 A / 210 W Inhibit Control The products are fitted with a remote control function by using the Inhibit/UVLO pin. The Inhibit control function allows the product to be turned on/off by an external device like a semiconductor or mechanical switch. The RC pin has an internal pull up. An external pull-up resistor should never be used with the inhibit pin. When the Inhibit pin is left open, the regulator will turn on when the input voltage is applied. Turn off is achieved by connecting the Inhibit pin to the GND. The reference figure above shows the typical application of the inhibit function. The input is not compatible with TTL logic device. An open-collector (or open-drain) discrete transistor is recommended for control. Turning the discrete transistor on applies a low voltage to the Inhibit control pin and disables the output of the module. If this device is then turned off, the module executes a soft-start power-up sequence. A regulated output voltage is produced within 20 ms. External Decoupling Capacitors Input capacitors: The PMR 8210 requires a minimum input capacitance of e 1000 F. The ripple current rating of the input capacitor must be at least 750 mA rms. An optional 22 F X5R/X7R ceramic capacitor is recommended to reduce RMS ripple current. The size and value of the input capacitor is determined by the converter's transient performance capability. This minimum value assumes that the converter is supplied with a responsive, low inductance input source. This source should have ample capacitive decoupling, and be distributed to the converter via PCB power and ground planes. Ceramic capacitors should be located as close as possible to the module's input pins, within 0.5 inch (1,3 cm). Adding ceramic capacitance is necessary to reduce the highfrequency ripple voltage at the module's input. This reduces the magnitude of the ripple current through the electrolytic capacitor, as well as the amount of ripple current reflected back to the input source. Additional ceramic capacitors can be added to further reduce the RMS ripple current requirement for the electrolytic capacitor. The main considerations when selecting input capacitors are the RMS ripple current rating, temperature stability, and less than 100 m of equivalent series resistance (ESR). Regular tantalum capacitors are not recommended for the input bus. These capacitors require a recommended 3/1301-BMR 629Technical 8210 Uen Specification Date Rev 2012-09-26 10 Reference EN/LZT 146 411 R1C March 2013 D (c) Ericsson AB minimum voltage rating of 2x (maximum dc voltage + ac ripple). This is standard practice to ensure reliability. No tantalum capacitors were found with a sufficient voltage rating to meet this requirement. Output capacitors: The PMR 8210 module requires a minimum output capacitance of 1000F of polymer-aluminum, tantulum, or polymer-tantalum type. The required capacitance above the minimum is determined by actual transient deviation requirements. See "TurboTrans Technology" information below. For both input and output capacitors, when the operating temperature is below 0C, the ESR of aluminium electrolytic capacitors increases. For these applications, OS-CON, polyaluminium, and polymer-tantalum types should be considered. If the TurboTrans feature is not used, minimum ESR and maximum capacitor limits must be followed. System stability may be effected and increased output capacitance may be required without TurboTrans. When using the PMR 8210, observe the minimum ESR of the entire output capacitor bank. The minimum ESR limit of the output capacitor bank is 7m. When using PMR 8210 without the TurboTrans feature, the maximum amount of capacitance is 1000 F of ceramic type. Large amounts of capacitance may reduce system stability. Utilizing the TurboTrans feature improves system stability, improves transient response, and reduces the amount of output capacitance required to meet system transient design requirements. For detaile information, see "TurboTrans Technology" information below. Output Voltage Adjust (Vadj) The product has an Output Voltage Adjust function. The function can be used to adjust the output voltage in the range from 3.0V to 5.25V. The Vo Adjust control sets the output voltage of the PMR 8210. The adjustment method requires the addition of a single external resistor, RSET, that must be connected directly between pins Vo Adjust (pin 18) and AGND (pin 4). The value of the required resistor can be calculated using the following formula. R SET = 0.7 V - 0.7 0.7 O 30.1 10 - 8.25 k Note: (1) R SET : Use a 0.05 W resistor with a tolerance of 1% and temperature stability of 100 ppm/C (or better). Connect the E Ericsson Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) 3/1301-BMR 629Technical 8210 Uen Specification EMQTUWX Approved 3 (10) No. Checked Date PMR 8000 series PoL Regulator EMAOLII Input 8 - 14 V, Output up to 40 A / 210 W Rev 2012-09-26 11 Reference EN/LZT 146 411 R1C March 2013 D (c) Ericsson AB 7\SLFDO&XUUHQW6KDULQJ'LDJUDP resistor directly between pins 18 and 4, as close to the regulator as possible, using dedicated PCB traces. (2) Never connect capacitors from Vo Adjust to either + Sense, GND, or Vo. Any capacitance added to the Vo Adjust pin affects the stability of the regulator. (3) For output voltages less than 1.2 V, the output ripple may increase (up to 2 x ) when operating at input voltages greater than (Vo x 12). Adjusting the switching frequency using the SmartSync feature may increase or decrease this ratio. .......................................................................................................................................................................................... Required Connections for Current Sharing TERMINAL NAME VI VO 10,11 GND Parallel Operation The PMR 8210 module is capable of being configured in parallel with another PMR 8210 module to share load current. To parallel the two modules, it is necessary to configure one module as the Master and one module as the Slave. To configure a module as the Master, connect the CONFIG pin (pin 1) to GND. The CONFIG pin of the Slave must be connected to VI. In order to share current, pins 2 through 5 of both the Master and Slave must be connected between the two modules. The module that is configured as the MASTER is used to control all of the functions of the two modules including Inhibit, ON/OFF control, AutoTrack sequencing, TurboTrans, SmartSync, +/- Remote Sense, and Output Voltage Adjust. The MASTER and the SLAVE must be powered from the same input voltage supply. When using TurboTrans while paralleling two modules, the TurboTrans resistor, RTT, must be connected from the TurboTrans pin (pin 19) of the Master module to the +Sense pin (pin 17) of the Master module. When paralleling modules the procedure to calculate the proper value of output capacitance and RTT is similar to that explained in the TurboTrans Selection section, however the values must be calculated for a single module. Therefore, the total output current load step must be halved before determining the required output capacitance and the RTT value as explained in the TurboTrans Selection section. The value of output capacitance calculated is the minimum required output capacitance per module and the value of RTT must be calculated using this value of output capacitance. The TurboTrans pin of the Slave module must be left open. MASTER NO. 6,7,14,15 8,9,12,13 SLAVE Connect to the Input Bus. Connect to the Input Bus. Connect to the Output Bus. Connect to the Output Bus. Connect to Common Power GND. Connect to Common Power GND. No Connection. Leave open-circuit. Inhibit and UVLO 21 Use for Inhibit control & UVLO adjustments. If unused leave open-circuit. Vo Adjust 18 Use to set the output voltage. Connect RSET resistor between this pin and AGND (pin 4). No Connection. Leave open-circuit. +Sense 17 Connect to the output voltage either at the load or at the module (pin 11). No Connection. Leave open-circuit. -Sense 16 Connect to the output GND either at the load or at the module (pin 13). No Connection. Leave open-circuit. Track 20 Connect to Track control or to VI (pin 15). No Connection. Leave open-circuit. TurboTransTM 19 Connect TurboTrans resistor, RTT, between this pin and +Sense (pin 17). No Connection. Leave open-circuit. SmartSync 22 Connect to an external clock. If unused connect to GND. Connect to Common Power GND. CONFIG 1 Connect to GND. Share 2 Connect to pin 2 of Slave. Connect to the Input Bus. Connect to pin 2 of Master. Comp 3 Connect to pin 3 of Slave. Connect to pin 3 of Master. AGND 4 Connect to pin 4 of Slave. Connect to pin 4 of Master. CLKIO 5 Connect to pin 5 of Slave. Connect to pin 5 of Master. Current sharing layout In current sharing applications the VI pins of both modules must be connected to the same input bus. The VO pins of both modules are connected together to power the load. The GND pins of both modules are connected via the GND plane. Four other inter-connection pins are connected between the modules. Below figure shows the required layout of the interconnection pins for two modules configured to share current. Notice that the Share (pin 2) connection is routed between the Comp (pin 3) and CLKIO (pin 5) connections. AGND (pin 4) should be connected as a thicker trace on an adjacent layer, running parallel to pins 2, 3 and 5. AGND must not be connected to the GND plane. E Ericsson Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) EMQTUWX Approved 4 (10) No. Checked PMR 8000 series PoL Regulator EMAOLII Input 8 - 14 V, Output up to 40 A / 210 W 3/1301-BMR 629Technical 8210 Uen Specification Date 2012-09-26 Rev 12 Reference EN/LZT 146 411 R1C March 2013 D (c) Ericsson AB Ics such as DSPs, micro-processors and ASICs. Remote Sense The products have remote sense that can be used to compensate for voltage drops between the output and the point of load. The sense traces should be located close to the PCB ground layer to reduce noise susceptibility. The remote sense circuitry will compensate for up to 0.3 voltage drop between output pins and the point of load. If the remote sense is not needed +Sense should be connected to +Out and -Sense should be connected to -Out. Over Temperature Protection (OTP) The regulators are protected from thermal overload by an internal over temperature shutdown circuit. If the internal temperature exceeds the OTP threshold, the module's inhibit control is internally pulled low. This turns the output off. The voltage drops as the external output capacitors are discharged by the load circuit. The product will make continuous attempts to start up (non-latching mode) and resume normal operation automatically when the temperature has dropped >10C below the temperature threshold. Over Current Protection (OCP) The regulators include current limiting circuitry for protection at continuous overload. The output voltage will decrease towards zero for output currents in excess of max output current (max IO). The regulator will resume normal operation after removal of the overload. The load distribution should be designed for the maximum output short circuit current specified. Soft-start Power Up From the moment a valid input voltage is applied, the soft-start control introduces a short time-delay (typically 5-15 ms) before allowing the output voltage to rise. The initial rise in input current when the input voltage first starts to rise is the charge current drawn by the input capacitors. Auto-TrackTM Function Auto-Track was designed to simplify the amount of circuitry required to make the output voltage from each unit power up and power down in sequence. The sequencing of two or more supply voltages during power up is a common requirement for complex mixed-signal applications, that use dual-voltage VLSI Notes on Use of Auto-TrackTM 1. The Track pin voltage must be allowed to rise above the module set-point voltage before the module regulates at its adjusted set-point voltage. 2. The Auto-Track function tracks almost any voltage ramp during power up, and is compatible with ramp speeds of up to 1 V/ms. 3. The absolute maximum voltage that may be applied to the Track pin is the input voltage VI. 4. The module cannot follow a voltage at its track control input until it has completed its soft-start initialization. This takes about 20 ms from the time that a valid voltage has been applied to its input. During this period, it is recommended that the Track pin be held at ground potential. 5. The Auto-Track function is disabled by connecting the Track pin to the input voltage (VI). When Auto-Track is disabled, the output voltage rises according to its softstart rate after input power has been applied. 6. The Auto-Track pin should never be used to regulate the module's output voltage for long-term, steady-state operation. Smart Sync Smart Sync is a feature that allows multiple power modules to be synchronized to a common frequency. When not used, this pin must be connect to GND. Driving the Smart Sync pins with an external oscillator set to the desired frequency, synchronizes all connected modules to the selected requency. The synchronization frequency can be higher or lower than the nominal switching frequency of the modules within the range of 240 kHz to 400 kHz. Synchronizing modules powered from the same bus eliminates beat frequencies reflected back to the input supply, and also reduces EMI filtering requirements. Eliminating the low beat frequencies (usually<10kHz) allows the EMI filter to be designed to attenuate only the synchronization frequency. Power modules can also be synchronized out of phase to minimize ripple current and reduce input capacitance requirements. The PMR 8210 requires that the external synchronization frequency be present before a valid input voltage is present or before release of the inhibit control. Pre-Bias Startup Capability E Ericsson Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) EMQTUWX Approved 5 (10) No. Checked PMR 8000 series PoL Regulator EMAOLII Input 8 - 14 V, Output up to 40 A / 210 W A prebias startup condition occurs as a result of an external voltage being present at the output of a power module prior to its output becoming active.This often occurs in complex digital systems when current from another power source is backfed through a dual-supply logic component, such as FPGA or ASIC. The PMR family of regulators incorporate synchronous rectifiers, but will not sink current during startup, or whenever the Inhibit pin is held low. However, to ensure satisfactory operation of this function, certain conditions must be maintained. For more inforamtion, please refer to Application Note 205. Turbo TransTM Technology Turbo TransTM optimizes the transient response of the regulator with added external capacitance using a single external resistor. The benefits of this technology include: reduced output capacitance, minimized output voltage deviation following a load transient, and enhanced stability when using ultra-low ESR output capacitors. The amout of output capacitance required to meet a target output voltage deviation, is reduded with Turbo TransTM activated. Likewise, for a given amout of output capacitance, with Turbo TransTM engaged, the amplitude of the voltage deviation following a load transient is reduced. Applications requiring tight transient voltage tolerances and minimized capacitor footprint area benefit from this technology. Utilizing Turbo TransTM requires connecting a resistor, RTT , between the +Sense pin (pin 17) and the Turbo TransTM pin (pin 19), The value of the resistor directly corresponds to the amount of output capacitance required. For the PMR 8210, the minimum required capacitance is 1000F. When using Turbo TransTM, capacitors with a capacitancexESR product below 10,000 Fxm are required. To have a better understanding of the required capacitors with Turbo TransTM, three types of capacitors are defined as below. a. TypeA = (100 < capacitanc e x ESR 1,000) b. TypeB = (1000 < capacitanc e x ESR 5000) c. TypeC = (5,000 < capacitanc e x ESR 10,000) As an example, let's look at a 12-V application requiring a 80 mv deviation during an 20A load transient. A majority of 560F, 10m output capacitors are used. Use the 12 V, Type C capacitor chart. Dividing 80mV by 20A gives 4mV/A transient voltage deviation per amp of transient load setp. Select 4mV/A on the Y-axis and read across to the "With TurboTrans" plot. Following this point down to the X-axis gives us a minimum required output capacitance of approximately 1700F. The required RTT resistor value for 1700F can then be calculated or selected from the below table. The required RTT resistor is approximately 31.6K. To see the benefit of Turbo TransTM, follow the 4mV/A marking across to the "Without TurboTrans" plot. Following that point down shows that you would need a minimum of 5500F of 3/1301-BMR 629Technical 8210 Uen Specification Date 2012-09-26 Rev 13 Reference EN/LZT 146 411 R1C March 2013 D (c) Ericsson AB output capacitance to meet the same transient deviation limit. This is the benefit of Turbo TransTM . A typical Turbo TransTM application schematic is also shown. E Ericsson Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) EMQTUWX Approved 6 (10) No. Checked PMR 8000 series PoL Regulator EMAOLII Input 8 - 14 V, Output up to 40 A / 210 W 3/1301-BMR 629Technical 8210 Uen Specification Date 2012-09-26 Rev 14 Reference EN/LZT 146 411 R1C March 2013 D (c) Ericsson AB Thermal Consideration General The regulators are designed to operate in different thermal environments and sufficient cooling must be provided to ensure reliable operation. Cooling is achieved mainly by conduction, from the pins to the host board, and convection, which is dependant on the airflow across the regulator. Increased airflow enhances the cooling of the regulator. The typical Output Current Derating graph can be found in the Output section for each model provides the available output current vs. ambient air temperature and air velocity at VI = 12 V. The product is tested on a 100 x 100 mm double-sided PCB with 2 oz. copper and the direction of airfow fro pin 10 to pin 22. For surface mount packages, multiple vias must be utilized. Definition of product operating temperature The product operating temperatures is used to monitor the temperature of the product, and proper thermal conditions can be verified by measuring the temperature at positions P1, P2, and P3. The temperature at these positions (TP1, TP2, TP3,) should not exceed the maximum temperatures in the table below. The number of measurement points may vary with different thermal design and topology. Temperatures above maximum TP1, measured at the reference point P1 are not allowed and may cause permanent damage. RTT Resistor Selection The Turbo TransTM resistor value, RTT can be determined from the Turbo TransTM programming equation, see the equation below. 1- ( RTT = 40 x Co ) 4700 ( k ) Co 5x( ) -1 4700 Where Co is the total output capacitance in F. Co values greater than or equal to 4700 F require RTT to be a short, 0. (The above equation results in a negative value for RTT when Co 4700 F) Position Description Max Temp. P1 Reference point (Q501) TP1=130 C P2 Inductor (L501) TP2=130 C P3 Inductor (L502) TP3=130 C E Ericsson Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) EMQTUWX Approved Checked PMR 8000 series PoL Regulator EMAOLII Input 8 - 14 V, Output up to 40 A / 210 W Connections Pin 1 2 3 Designation CONFIG Share Comp 7 (10) No. Function When two modules are connected together to share load current one must be configured as the MASTER and the other as the SLAVE. This pin is used to configure the module as either MASTER or SLAVE. To configure the module as the MASTER, connect this pin to GND. To condigure the module as the SLAVE, connect this pin to VI (pin 6). When not sharing current, this pin should be connected to GND. This pin is used when connecting two modules together to share load current. When two modules are sharing the current the Share pin of both modules must be connected together. When not sharing current, this pin MUST be left open (floating). This pin is used when connecting two modules together to share load current. When two modules are sharing current the Comp pin of bothe modules must be connected together. When not sharing current, this pin MUST be left open (floating). 3/1301-BMR 629Technical 8210 Uen Specification Date Rev 15 Reference EN/LZT 146 411 R1C March 2013 2012-09-26 D (c) Ericsson AB 4 AGND This pin is the internal analog ground of the module. This pin provides the return path for the VoAdjust resistor (RSET). When two modules are sharing current the AGND pin of both modules must be connected together. Also, when two modules are connected, RSET must be connected only on the MASTER module. This pin is used when connecting two modules together to share load current. When two modules are sharing current the CLKO pin of both modules must be connected togethe. When not sharing current, this pin MUST be left open (floating). 5 CLKIO 6 VI The positive input voltage power node to the module, which is referenced to common GND. 7 VI See pin 6 8 GND This is the common ground connection for the VI and Vo power connections. It is also the 0 Vdc reference for the control inputs. 9 GND See pin 8 10 VO This regulated positive power output with respect to GND. See pin 10 11 VO 12 GND See pin 8 13 GND See pin 8 14 VI VI See pin 6 15 16 -Sense See pin 6 The sense input allows the regulation circuit to compensate for voltage drop between the module and the load. The -Sense pin should always be connected to GND, either at the load for optimal voltage accuracy, or at the module (pin 13). E Ericsson Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) EMQTUWX Approved 8 (10) No. Checked PMR 8000 series PoL Regulator EMAOLII Input 8 - 14 V, Output up to 40 A / 210 W 17 +Sense The sense input allows the regulation circuit to compensate for voltage drop between the module and the load. The +Sense pin should always be connected to VO, either at the load for optimal voltage accuracy, or at the module (pin 11). 18 Vo Adjust A 0.05 W 1% resistor must be directly connected between this pin and pin4 (AGND) to set the output voltage to a value higher than 0.7 V. The temperature stability of the resistor should be 100 ppm/ (or better). The setpoint range for the output voltage is from 0.7V to 3.6V. If left open circuit, the output voltage defaults to its lowest value. For further information, refer to the information for each output voltage sector. 19 Turbo TransTM This input pin adjusts the transient response of the regulator. To activate the Turbo TransTM feature, a 1%, 50mW resistor must be connected between this pin and pin 17 (+Sense) very close to the module. For a given value of output capacitance, a reduction in peak output voltage deviation is achieved by using this feature. If unused, this pin must be left open-circuit. External capacitance must never be connected to this pin. The resistance requirement can be selected TM from the Turbo Trans resistor table which is shown above. 3/1301-BMR 629Technical 8210 Uen Specification Date 2012-09-26 Rev 16 Reference EN/LZT 146 411 R1C March 2013 D (c) Ericsson AB 20 Track This is an analog control input that enables the output voltage to follow an external voltage. This pin becomes active typically 25 ms after the input voltage has been applied, and allows direct control of the output voltage from 0 V up to the nominal set-point voltage. Within this range the module's output voltage follows the voltage at the Track pin on a volt-for-volt basis. When the control voltage is raised above this range, the module regulates at its set-point voltage. The features allows the output voltage to rise simultaneously with other modules powered from the same input bus. If unused, this input should be connected to VI . NOTE: Due to the undervoltage lockout feature, the output of the module cannot follow its own input voltage during power up. For more information, see the related application note. 21 Inhibit and UVLO The Inhibit pin is an opencollector/drain, negative logic input that is referenced to GND. Applying a low level ground signal to this input disables the module's output and turns off the output voltage. When the Inhibit control is active, the input current drawn by the regulator is significantly reduced. If the Inhibit pin is left open-circuit, the module produces an output whenever a valid input source is applied. This pin is also used for input undervoltage lockout(UVLO) programming. Connecting a resistor from this pin to GND (pin 13) allows the ON threshold of the UVLO to be adjusted higher than the default value. For more information, see related application information. E Ericsson Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) EMQTUWX Approved Checked PMR 8000 series PoL Regulator EMAOLII Input 8 - 14 V, Output up to 40 A / 210 W 22 SmartSync 9 (10) No. This input pin sychronizes the switching frequency of the module to an external clock frequency. The SmartSync feature can be used to sychronize the switching frequency of multiple modules, aiding EMI noise suppression efforts. The external synchronization frequency must be present before a valid input voltage is present, or before the release of inhibit control. If unused, this pin MUST be connected to GND. For more information, please see the related application note. 3/1301-BMR 629Technical 8210 Uen Specification Date 2012-09-26 Rev Reference EN/LZT 146 411 R1C March 2013 D (c) Ericsson AB 17 E Ericsson Internal PRODUCT SPEC. MECHANICAL Prepared (also subject responsible if other) EXXUYNG Approved PMR 8000 PMR 8000 series PoL Regulator series SEC/D (Julia You) 1 (3) No. 4/1301-BMR 629Technical Uen Specification Checked Date See 1 2009-08-31 Input 8 - 14 V, Input V, Output Output up up to to 40 A A // 210 W W Mechanical Information - Surface mount version Rev Reference EN/LZT 146 EN/LZT 146 411 411 R1C R1B March November 20132009 B (c) Ericsson AB 17 18 E Ericsson Internal PRODUCT SPEC. MECHANICAL Prepared (also subject responsible if other) EXXUYNG Approved PMR 8000 PMR 8000 series PoL Regulator series SEC/D (Julia You) 2 (3) No. 4/1301-BMR 629Technical Uen Specification Checked Date See 1 2009-08-31 Input 8 - 14 V, Input V, Output Output up up to to 40 A A // 210 W W Mechanical Information- Through hole mount version Rev Reference EN/LZT 146 EN/LZT 146 411 411 R1C R1B March November 20132009 B (c) Ericsson AB 18 19 E Ericsson Internal PRODUCT SPECIFICATION MECHANICAL Technical Specification Prepared (also subject responsible if other) No. EXXUYNG / EPETSCH 5/1301-BMR 629 Uen Approved Date EN/LZT 146 EN/LZT 146 411 411 R1C R1B March November 20132009 2009-08-31 (c) B Ericsson AB PMR 8000 PMR 8000 series series PoL Regulator Checked SEC/D SeeW 1 Input 8[Julia Input - 14You] V, Output V, Output up up to to 40 A A // 210 W Rev 1 (4) 19 20 Reference Soldering Information - Hole Mounting The hole mounted product is intended for plated through hole mounting by wave or manual soldering. The pin temperature is specified to maximum to 270C for maximum 10 seconds. A maximum preheat rate of 4C/s and maximum preheat temperature of 150C is suggested. When soldering by hand, care should be taken to avoid direct contact between the hot soldering iron tip and the pins for more than a few seconds in order to prevent overheating. A no-clean flux is recommended to avoid entrapment of cleaning fluids in cavities inside the product or between the product and the host board. The cleaning residues may affect long time reliability and isolation voltage. Delivery Package Information The products are delivered in tape and reel (SMD) or antistatic trays (TH & SMD) Reel Specifications Material Antistatic PS Surface resistance 10 < Ohm/square < 10 Bakeability The reels cannot be baked 8 12 Tape width, W 56 mm [2.205 inch] Pocket pitch, P1 36 mm [1.417 inch] Pocket depth, K0 10.4 mm [0.41 inch] Reel diameter 330 mm [13 inch] Reel capacity 150 products /reel Reel weight 150 g empty, 2550 g/full reel Carrier thickness 0.05 mm [0.002 inch] Box capacity 300 products [2 reel/box) E Ericsson Internal PRODUCT SPECIFICATION MECHANICAL Technical Specification Prepared (also subject responsible if other) No. EXXUYNG / EPETSCH 5/1301-BMR 629 Uen Approved Date EN/LZT 146 EN/LZT 146 411 411 R1C R1B March November 20132009 2009-08-31 (c) B Ericsson AB PMR 8000 PMR 8000 series series PoL Regulator Checked SEC/D SeeW 1 Input 8[Julia Input - 14You] V, Output V, Output up up to to 40 A A // 210 W Rev 2 (4) 20 21 Reference Tray Specifications Material Antistatic PET Surface resistance 10 < Ohm/square < 10 Bakability The trays cannot be baked Tray thickness 0.8 mm [0.03 inch] Box capacity 125 products (5 full trays/box) Tray weight 40 g empty, 440 g/full tray Tray capacity 25 products/tray 8 12 Dry pack information The products are delivered in trays or tape on reel. These inner shipment containers are dry packed in standard moisture barrier bags according to IPC/JEDEC standard J-STD-033A (Handling, packing, shipping, and use of moisture/reflow sensitivity surface mount devices). Using products in high temperature Pb-free soldering processes requires dry pack storage and handling. In case the products have been stored in an uncontrolled environment and no longer can be considered dry, the modules must be baked according to the referred IPC/JEDEC standard. E Ericsson Internal PRODUCT SPECIFICATION MECHANICAL Technical Specification Prepared (also subject responsible if other) No. EXXUYNG / EPETSCH 5/1301-BMR 629 Uen Approved Date EN/LZT 146 EN/LZT 146 411 411 R1C R1B March November 20132009 2009-08-31 (c) B Ericsson AB PMR 8000 PMR 8000 series series PoL Regulator Checked SEC/D SeeW 1 Input 8[Julia Input - 14You] V, Output V, Output up up to to 40 A A // 210 W Rev Reference Product Qualification Specification Characteristics External visual inspection IPC-A-610 Change of temperature (Temperature cycling) IEC 60068-2-14 Na Temperature range Number of cycles Dwell/transfer time -40 to 100C 1000 15 min/0-1 min Cold (in operation) IEC 60068-2-1 Ad Temperature TA Duration -45C 72 h Damp heat IEC 60068-2-67 Cy Temperature Humidity Duration 85C 85 % RH 1000 hours Dry heat IEC 60068-2-2 Bd Temperature Duration 125C 1000 h Electrostatic discharge susceptibility IEC 61340-3-1, JESD 22-A114 IEC 61340-3-2, JESD 22-A115 Human body model (HBM) Machine Model (MM) Class 2, 2000 V Class 3, 200 V Immersion in cleaning solvents IEC 60068-2-45 XA, method 2 Water Glycol ether Isopropyl alcohol 55C 35C 35C Mechanical shock IEC 60068-2-27 Ea Peak acceleration Duration 100 g 6 ms J-STD-020C Level 1 (SnPb-eutectic) Level 3 (Pb Free) 225C 260C MIL-STD-202G, method 108A Duration 1000 h IEC 60068-2-20 Tb, method 1A Solder temperature Duration 270C 10-13 s IEC 60068-2-21 Test Ua1 IEC 60068-2-21 Test Ue1 Through hole mount products Surface mount products All leads All leads Preconditioning Temperature, SnPb Eutectic Temperature, Pb-free 150C dry bake 16 h 215C 235C Preconditioning Temperature, SnPb Eutectic Temperature, Pb-free Steam ageing 235C 245C Frequency Spectral density Duration 10 to 500 Hz 2 0.07 g /Hz 10 min in each direction Moisture reflow sensitivity 1 Operational life test Resistance to soldering heat 2 Robustness of terminations IEC 60068-2-58 test Td 1 IEC 60068-2-20 test Ta 2 Solderability Vibration, broad band random IEC 60068-2-64 Fh, method 1 Notes 1 Only for products intended for reflow soldering (surface mount products) 2 Only for products intended for wave soldering (plated through hole products) 3 (4) 21 22