1
Two-circuit Limit Switch/Long-life Two-circuit Limit Switch
WL-N/WLM-N
Select the Best Two-circuit Switch for the
Operating Environment and Application
from a Wide Range of Models
A wide selection of models is available, including
General-purpose, Environment-resistant, and Spatter-
prevention Switches.
Standard-feature gold-clad crossbar contacts provide
high reliability.
Applicable to either standard loads or microloads.
Switches with Lever Actuators provide 90° overtravel,
one-side operation, and four-direction head mounting.
Approved standards: EN/IEC, UL, cUL, and CCC.
Contact your OMRON representative for information on
approved models.
Be sure to read Safety Precautions on page 46 to 50 and
Safety Precautions for All Limit Switches.
Features
Many Variations in Standard Limit Switches
A Wide Range of Models
The series includes includes many different actuators that you select
to match the workpiece shape and motion, and a wide range of Switch
variations, such as models with operation indicators for easier
working and maintenance and models with different types of
connectors.
Select from Six Types of Environment Resistance
The series includes Airtight Switches, Hermetic Switches, Heat-
resistant Switches, Low-temperature Switches, Corrosion-proof
switches, and Weather-proof Switches. You can select the model
based on the onsite environment.
Excellent Performance on Arc Welding Lines or Sites with
Spattering Cutting Powder
Ideal for Welding Sites
These Switches use stainless steel or resin to prevent the adhesion
of spatter.
They can be used to reduce problems caused by zinc power
generated during welding.
Mechanical Endurance of 30 Million Operations
Long-life Models for High-frequency Applications
A mechanical durability of 30 million operations minimum is provided.
The head features a double-seal structure with a head cap and oil
seal.
DPDB Operation
The double-pole, double-break structure ensures circuit braking.
Degree of Protection; IP67
Approved Standards to Aid Export Machines
The Switches are certified for EN/IEC, UL, cUL, and CCC making
them ideal for export machines.
Applicable to Either Standard Loads or Microloads
Standard-feature gold-clad contacts provide high reliability.
The use of a high-contact-pressure crossbar structure also increases
reliability.
Easy to Work With
Downsizing of the built-in switch has increased the space to house the
wiring.
The insulating paper that was often in the way when wiring has been
eliminated.
Nickle-plated steel screws are used for the terminal screws.
The screws adhere to magnetized screwdrivers to prevent dropping and
loosing them.
Models with Connectors to Reduce Wiring
A neon lamp or LED indicates the operating status.
The 3D structure of the lamp cover disperses light so you can check
the operating status from the side.
Standard Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches
Features Common to All Switches
Load Load
13(NO)
Za
12(NC)
(NO)14
11
12
14
13
(NC)11
All high-sensitivity and high-precision models have been integrated into the WL Series. Refer to
the model replacement table page 45 and order high-sensitivity and high-precision models with
the WL model numbers.
WL-N/WLM-N
2
Product Configuration
* The high-sensitivity, high-precision models have been integrated into the WL Series. Refer to the model replacement table on page 45 and order
WL models.
General-purpose
Standard
Basic Switches WLC@-N
Operation indicators
Sensor I/O connectors
High-sensitivity Switches * (WLG@-N)
High-precision Switches * (WLGCA2-N)
Protective Switches WLCA32-@-N
Indicator-equipped Switches:
Light emitting diodes (LED) WL@-LD-N
Indicator-equipped Switches:
Neon lamps WL@-LE-N
Direct-wired Switches WL-@LDK@-N
Pre-wired Switches WL@-@LD-M1@-N
WL@-@LD-AGJ-N
WL@-@LD-DGJ-N
WL@-@LD-DK1EJ-N
Environment-resistant
Spatter-prevention
Long-life
High-precision Switches * (WLGCA2-@S-N)
Airtight Switches WL@-55-N
Hermetic Switches WL@-139-N
WL@-140-N
WL@-141-N
WL@-145-N
WL@-RP40-N
WL@-RP60-N
Heat-resistant Switches WL@-TH-N
Low-temperature Switches WL@-TC-N
Corrosion-proof Switches WL@-RP-N
Weather-proof Switches WL@-P1-N
Basic Switches WLC@-@S-N
High-sensitivity Switches * (WLG@-@S-N)
High-precision Switches * (WLMGCA2-@-N)
Basic Switches WLMCA2-@-N
High-sensitivity Switches * (WLMG2-@-N)
WL-N/WLM-N
3
Environment-resistant Switches
Item Environment-resistant
Type Model Application Environment-resistant construction Applicable models
Airtight seal WL@-55-N
For uses in locations
subject to cutting oil or
water
Uses an airtight built-in switch.
Note: Use the SC Connector for the conduit opening.
All models except the low-
temperature and heat-
resistant models
Note: Models can be produced
using standard
actuators.
Hermetic seal
(Molded terminals/
Anti-coolant)
WL
@
-139-N
Refer to page 29 for information on the
environment-resistant construction of Switches
with Hermetic Seals.
All models except the low-
temperature and heat-
resistant models
Note: Models can be produced
using standard
actuators. Only the
WLCA2-N can be
produced for the WL@-
141-N and WL@-145-N.
WL
@
-140-N
WL
@
-141-N
WL
@
-145-N
WL
@
-RP40-N
WL
@
-RP60-N
Low-temperature WL@-TC-N
Can be used at a
temperature of –40°C
(operating temperature
range: –40 to 40°C), but
cannot withstand icing.
Uses a general-purpose built-in switch.
Uses rubber and grease with superior cold
resistance.
All models except airtight
seal, hermetic seal, heat-
resistant, corrosion-proof,
and indicator-equipped
models
Heat-resistant WL@-TH-N
Can be used in
temperatures of 120°C
(operating temperature
range: 5 to 120°C).
Uses rubber and grease with superior heat
resistance.
All models except airtight
seal, hermetic seal, heat-
resistant, corrosion-proof,
indicator-equipped, nylon
roller (WLCA2-26N-N), and
resin rod (WLNJ-2-N)
models
Corrosion-proof WL@-RP-N For use in locations
subject to corrosive gases
and chemicals.
Diecast parts, such as the switch box, are made
of corrosion-proof aluminum.
Rubber sealing parts are made of fluorine
rubber, which aids in resisting oils and
chemicals.
Exposed nuts and screws (except the actuator
section) are made of stainless steel.
Moving and rotary parts such as rollers are
made of sintered stainless steel or stainless
steel.
The Head, box, and cover are yellow.
All models except fork lever
lock (WLCA32-41 to -44-
N), low-temperature, heat-
resistant, and indicator-
equipped models
Weather-proof WL@-P1-N For use in parking lots and
other outdoor locations.
The roller is made of stainless steel with superior
corrosion resistance.
Exposed nuts and screws are made of stainless
steel.
Uses rubber and grease with superior weather
resistance.
Only basic (WLCA2-N/
CA12-N/CL-N) models
(excluding heat-resistant
models).
This does not apply to Low-
temperature or Heat-
resistance, or Indicator-
equipped Switches.
WL-N/WLM-N
4
Selection Guide
With the WL-N Series, OMRON will combine the switch, Actuator, and wiring method required to build the ideal switch for
your application.
*1. Not all functions can be combined with environment-resistant switches. Refer to the applicable models on the previous page.
*2. Refer to page 29 for information on the construction of Hermetic Switches.
*3. The high-sensitivity, high-precision models have been integrated into the WL Series. Refer to the model replacement table on page 45 and
order WL models.
The WL-N Series consists of four basic types: General-
purpose, Environment-resistant, Spatter-protection,
and Long-life Switches. WLCA2-N Switches can be
used for the most common applications.
The high-sensitivity, high-precision models have been
integrated into the WL Series. Refer to the model
replacement table on page 45 and order high-sensitivity
and high-precision models with the WL model numbers.
Normal
High-temperature
Low-temperature
Outdoors
10°C +80°C
+5°C+120°C
40°C +40°C
Water-resistant to IP67.
Environment Key specifications Models
WL@-N General-purpose
Switches
WLM@-N Long-life Switches
WL@-TH-N Heat-resistant
Switches *1
WL@-TC-N Low-temperature
Switches *1
WL@-P1-N Weather-proof
Switches *1
Water drops and mist
Uses an airtight built-in switch. WL@-55-N Airtight Switches *1
WL@-RP-N Corrosion-proof
Switches *1
WL@-S-N Spatter-prevention
Switches
Chemicals and oil
WL@-139-N
Hermetic, Molded-terminal
Switches *1, *2
WL@-RP40-N
Hermetic, Molded-terminal
Switches *1, *2
WL@-140-N
Hermetic, Molded-terminal
Switches *1, *2
WL@-141-N, -145-N
Hermetic, Molded-terminal
Switches *1, *2
(Only the WLCA2-N, WLG2-N *3, and
WLGCA2
-N
*3, can be produced.)
WL@-RP60-N
Hermetic, Molded-terminal
Switches *1, *2
According to Operating Environment
To increase heat resistance, the rubber material and the plunger
material have been changed.
Cables are attached. Uses a general-purpose built-in switch.
The cover screws, case cover, and conduit opening are molded from
epoxy resin to increase the seal. (The cover cannot be removed.)
Cables are attached. Uses an airtight built-in switch.
The cover screws, case cover, and conduit opening are molded from
epoxy resin to increase the seal. (The cover cannot be removed.)
Cables are attached. Uses an airtight built-in switch.
The cover screws, case cover, and conduit opening are molded from
epoxy resin to increase the seal. (The cover cannot be removed.)
Double seal against oil including head cap countermeasure for
cutting chips and an oil seal.
-141: The Head section is molded from epoxy resin;
Head direction cannot be changed.
-145: The Head section is molded from epoxy resin;
Head can be in any of 4 directions.
Cables are attached. Uses an airtight built-in switch.
The case cover and conduit opening are molded from epoxy
resin to increase the seal. (The cover cannot be removed.)
The SC connector can be removed, so it is possible to use
flexible conduit for the cable.
To prevent spatter during welding, a heat-resistant resin is used for
the indicator cover and screws and rollers are all made from
stainless steel.
Cables are attached. Uses an airtight built-in switch.
The cover screws, case cover, conduit opening, and head screws
are molded from epoxy resin to increase the seal.
(The cover and head cannot be removed.)
Rubber parts are made from fluorine rubber to increase
resistance to coolant.
Rubber parts are made from epichlorhydrin rubber, which has a
high-tolerance to changes in temperature.
Stainless steel is used for the screws.
The roller is made of stainless steel with superior corrosion resistance.
Corrosion-proof specifications have been used for the housing,
fluorine rubber has been used for rubber parts, and stainless
steel has been used for screws and nuts (except for the actuator)
to increase resistance to oils, chemicals, and weather.
To increase resistance to cold, epichlorhydrin rubber and other
measures are used.
Ambient operating temperature
Constant water
drops and mist
Coolant
Spattering from
welding
Constant water
drops or splattering
cutting powder
Operating environment
WL-N/WLM-N
5
* The high-sensitivity, high-precision models have been integrated into the WL Series. Refer to the model replacement table on page 45 and order
WL models.
Conditions Key specifications Models
According to Application Conditions
Switching standard
loads
Switching
microloads
Normal durability
Long-life
0.1 A at 125 VAC, resistive load
0.1 A at 30 VDC, resistive load
10 A at 125,250, or 500 VAC
0.8 A at 125 VDC
0.4 A at 250 VDC Entire WL@-@-N Series
Applicable to either standard loads or microloads.
WL@-N General-purpose Switches
WL@-S-N Spatter-prevention Switches
WLM@-N Long-life Switches
Mechanical: 15 million operation min.
(10 million operation min. for high-sensitivity
models * or flexible rod models)
Mechanical: 30 million operation min.
Durability Load
According to Ease of Installation and Maintenance
Connector
attachment in
control and relay
boxes
One-touch
connector
attachment
Screw tightening
and installation
Daily inspections
and maintenance
checks
LED
10 to 115 VAC/DC
Switching light-ON between operating/not
operating. (Switching not possible for models
with molded terminals.)
Neon lamp
125 to 250 VAC
Switching light-ON between operating/not
operating. (Switching is not possible for
Switches with Molded Terminals.)
Pre-wired connector, 4-conductor.
Greatly reduces wiring work.
Smartclick connectors for even easier
maintenance.
Direct-wired connector, 4-conductor.
Greatly reduces wiring work.
Pre-wired connector, 2-conductor.
Greatly reduces wiring work.
Smartclick connectors for even easier
maintenance.
Direct-wired connector, 2-conductor.
Greatly reduces wiring work.
Screw terminals. No ground terminal.
Conduit size: G1/2
Screw terminals. Ground terminal.
Conduit size: 4 sizes
WL@-@LD-@GJ-N
General-purpose, Pre-wired Connector Switches
WL@-@S-@GJS-N
Spatter-prevention, Pre-wired Connector Switches
WLM@-LD-@GJ-N
Long-life, Pre-wired Connector Switches
WL@-@LD-M1@J-N
General-purpose, Pre-wired Connector Switches
WL@-@S-M1@J-1-N
Spatter-prevention, Pre-wired Connector Switches
WLM@-LD-M1@J-N
Long-life, Pre-wired Connector Switches
WL@-@LDK13@-N
General-purpose, Direct-wired Connector Switches
WLM@-LDK13@-N
Long-life, Direct-wired Connector Switches
WL@-@LDK43@-N
General-purpose, Direct-wired Connector Switches
WLM@-LDK43@-N
Long-life, Direct-wired Connector Switches
WL@-N General-purpose Switches
WL@-N General-purpose Switches
WLM@-N Long-life Switches
WL@-LD-N
General-purpose, Indicator-equipped (LED) Switches
WL@-LDS-N
Spatter-prevention, Indicator-equipped (LED) Switches
WL@-LE-N
General-purpose, Indicator-equipped (Neon Lamp) Switches
WL@-LES-N
Spatter-prevention, Indicator-equipped (Neon Lamp) Switches
Conditions Key specifications Models
Wiring specification Operation indicator
WL-N/WLM-N
6
R38
R50
R63
R25 to 89
25 to 140
350 to 380
427.5
According to Form of Operation
Detection object Key specifications Models
Adjustable between
dog and lever
Cams or
workpieces with
vertical movement
Round-trip
operation of
passing dogs
Dogs or workpieces
with large
deflection
Dogs and
workpieces
(Mounts in any of
4 directions)
Passing dogs,
high sensitivity
General
Passing dogs
High precision
Short lever
One-Horizontal operation possible.
Head mounts in any of 4 directions.
Medium lever
One-side operation possible.
Head mounts in any of 4 directions.
Long lever
One-side operation possible.
Head mounts in any of 4 directions.
Head mounts in any of 4 directions.
Head mounts in any of 4 directions.
Head mounts in any of 4 directions.
Head mounts in any of 4 directions.
Head mounts in any of 4 directions.
Head mounts in any of 4 directions.
Equipped with sealing boot.
Equipped with sealing boot.
Equipped with sealing boot.
Head mounts in any of 4 directions.
One-side operation possible.
Head mounts in any of 4 directions.
One-side operation possible.
Head mounts in any of 4 directions.
One-Horizontal operation possible.
Head mounts in any of 4 directions.
One-Horizontal operation possible.
Head mounts in any of 4 directions.
General-purpose Switches
Spatter-prevention Switches
Long-life Switches
WLCA2-N General-purpose Switches
WLCA2-2-N General-purpose Switches
WLCA2-2N-N General-purpose Switches
WLCA2-@S-N Spatter-prevention Switches
WLMCA2-N Long-life Switches
WLSD2-N Horizontal-roller Plunger Actuator
WLD28-N Sealed Top-roller Plunger Actuator
Not equipped with sealing boot. WLD2-N Top-roller Plunger Actuator
WLSD3-N Horizontal-ball Plunger Actuator
WLSD-N Horizontal Plunger Actuator
WLD18-N Sealed Top Plunger Actuator
WLD38-N Sealed Top-ball Plunger Actuator
WLCA32-44-N Fork Lever Lock Actuator
WLCA32-43-N Fork Lever Lock Actuator
WLCA32-42-N Fork Lever Lock Actuator
WLCA32-41-N Fork Lever Lock Actuator
WLCAL5-N Rod Spring Lever Actuator
WLCAL4-N Adjustable Rod Lever Actuator
WLCL-N Adjustable Rod Lever Actuators
WL@12-N Adjustable Roller Lever Actuators
WL@2-8-N Roller Lever Actuators
WL@2-7-N Roller Lever Actuators
WL@2-N Roller Lever Actuators
WL@2-@S-N Roller Lever Actuators
WLM@2-N Roller Lever Actuators
Actuators Operation angles
90° 90°
90° 90°
10°
90° 90°
25° 20°
15°
TT (total travel) PT (pretravel)
WLCA2-N WLCA2-2-N WLCA2-2N-N
* Refer to the model replacement table on page 45
and order high-sensitivity and high-precision
models with the WL model. (The TT is different.)
WL-N/WLM-N
7
Application Examples
Detection of Passing Pallets on Production
Lines
Detection of Work Table Origins (X, Y, and Z)
on Machine Tools
Detection of Forward and Reverse Movement
of Hydraulic Cylinders on Molding Machines
Detection of Arm Movement on Welding
Robots
Detection of Car Pallet Positions in Parking
Towers
Detection of Vertical Limits on Conveyor
Systems
WL-N/WLM-N
8
Model Number Structure
Model Number Legend (Not all combinations are possible. Contact your OMRON representative for details.)
(1) Actuator and Property Specifications
*1. Manufacturing has been discontinued.
The high-sensitivity, high-precision models have been integrated
into the WL Series. Refer to the model replacement table on page
45 and order high-sensitivity and high-precision models with the
WL model numbers.
(2) Built-in Switch Type
(3) Conduit Size, Ground Terminal Specifications
*2. Models with ground terminals are certified for EN/IEC (CE Marking).
(4) Indicator Type
(5) Lever Type
General-purpose Switches
Code Lever Pretravel (PT)
CA2 Roller lever: R38 mm
15±5°
CA2-7 Roller lever: R50 mm
CA2-8 Roller lever: R63 mm
CA12 Adjustable roller lever: R25 to 89 mm
CL Adjustable rod lever: 25 to 140 mm
CAL4 Adjustable rod lever: 350 to 380 mm
CAL5 Rod spring lever
CA2-2 Roller lever: R38 mm
25±5°
CA12-2 Adjustable roller lever: R25 to 89 mm
CL-2 Adjustable rod lever: 25 to 140 mm
CA2-2N Roller lever: R38 mm
20° max.
CA12-2N Adjustable roller lever: R25 to 89 mm
CL-2N Adjustable rod lever: 25 to 140 mm
G2 Roller lever, high sensitivity: R38 mm *1
10°
G12 Adjustable roller lever, high sensitivity:
R25 to 89 mm *1
GL Adjustable rod lever, high sensitivity:
25 to 140 mm *1
GCA2 Roller lever, high precision: R38 mm *1 5°
CA32-41 Fork lever lock
55° max.
CA32-42 Fork lever lock
CA32-43 Fork lever lock
D18 Sealed top plunger
1.7 mm max.
D28 Sealed top-roller plunger
D38 Sealed top-ball plunger
D2 Top-roller plunger
SD Horizontal plunger
2.8 mm max.
SD2 Horizontal-roller plunger
SD3 Horizontal-ball plunger
NJ Flexible rod: Coil spring 20±10 mm
NJ-30 Flexible rod: Coil spring, multi-wire
NJ-2 Flexible rod: Resin rod 40±20 mm
NJ-S2 Flexible rod: Steel wire
+2°
1°
+2
0
Code Specification
Blank Standard built-in switch
55 Airtight built-in switch
Code Specifications
Conduit Size Ground terminal
Blank G1/2 None
G1 G1/2
Provided *2
G Pg13.5
YM20
TS 1/2-14NPT
Code Specifications
Blank No indicator
LE Neon lamp: 125 to 250 VAC
LD LED (10 to 115 VAC/DC)
Code Specifications
Blank Standard lever (Allen-head bolt)
A Double nut lever
WL-N/WLM-N
9
Model Number Legend (Not all combinations are possible. Contact your OMRON representative for details.)
(1) Actuator and Property Specifications
*1. Manufacturing has been discontinued.
The high-sensitivity, high-precision models have been integrated
into the WL Series. Refer to the model replacement table on page
45 and order high-sensitivity and high-precision models with the
WL model numbers.
(2) Built-in Switch Type
(3) Indicator Type
(4) Connector Type
*2. DC models are certified for EN/IEC (CE Marking).
*3. Refer to Contact Forms on page 16 for details on connector pin numbers.
*4. The standard cable length is 0.3 m. Contact your OMRON representative for information on other cable lengths.
General-purpose Switches
Sensor I/O Connector Switches
Code Lever Pretravel (PT)
CA2 Roller lever: R38 mm 15±5°
G2 Roller lever, high sensitivity: R38 mm *1 10°
GCA2 Roller lever, high precision: R38 mm *1 5°
D28 Sealed top-roller plunger 1.7 mm max.
D2 Top-roller plunger
+2°
1°
+2
0
Code Specification
Blank Standard built-in switch
55 Airtight built-in switch
Code Specifications
LD LED (10 to 115 VAC/DC)
Code Specification
Shape Voltage used *2 Wiring locations Connector pin No. *3
K13A
Direct-wired connector Threaded (M12)
AC NO only NO:
K13 DC NO only NO:
K43A AC NC+NO NC: , NO:
K43 DC NC+NO NC: , NO:
-M1J
Pre-wired connector *4
Threaded (M12)
DC NO only NO:
-M1GJ DC NO only NO:
-M1JB DC NC only NC:
-AGJ AC NC+NO NC: , NO:
-DGJ DC NC+NO NC: , NO:
-DK1EJ DC NO only NC: , NO:
-M1TJ
Smartclick
DC NO only NO:
-M1TGJ DC NO only NO:
-M1TJB DC NC only NC:
-DTGJ DC NC+NO NC: , NO:
-DTK1EJ DC NO only NC: , NO:
3 4
3 4
1 2
3 4
1 2
3 4
3 4
1 4
2 3
1 2
3 4
1 2
3 4
2
3 4
3 4
1 4
2 3
1 2
3 4
2
3 4
WL-N/WLM-N
10
Model Number Legend (Not all combinations are possible. Contact your OMRON representative for details.)
(1) Actuator and Property Specifications
*1. Manufacturing has been discontinued. The high-sensitivity, high-
precision models have been integrated into the WL Series. Refer
to the model replacement table on page 45 and order high-
sensitivity and high-precision models with the WL model numbers.
(2) Environment-resistant Model Specifications
(3) Built-in Switch Type
(4) Temperature Specifications
*2. Cannot be combined with Corrosion-proof (RP) or Weather-proof
(P1) Switches.
(5) Hermetic Specification
(6) Conduit Size, Ground Terminal Specifications
*3. Models with ground terminals are certified for EN/IEC (CE Marking).
(7) Indicator Type
*4. Cannot be combined with Corrosion-proof (RP), Weather-proof
(P1), Heat-resistant (TC), or Low-temperature (TC) Switches.
(8) Indicator Wiring Specification
*5. Always include the indicator wiring specification if you specify a
(5) hermetic structure and an (7) indicator.
(9) Lever Type
Environment-resistant Switches
WL@-@@@@@@@@-N
(1) (2) (3) (4) (5) (6) (7) (8) (9)
Code Lever Pretravel
(PT)
CA2 Roller lever: R38 mm
15±5°
CA2-7 Roller lever: R50 mm
CA2-8 Roller lever: R63 mm
CA12 Adjustable roller lever: R25 to 89 mm
CL Adjustable rod lever: 25 to 140 mm
CAL4 Adjustable rod lever: 350 to 380 mm
CAL5 Rod spring lever
CA2-2 Roller lever: R38 mm
25±5°
CA12-2 Adjustable roller lever: R25 to 89 mm
CL-2 Adjustable rod lever: 25 to 140 mm
CA2-2N Roller lever: R38 mm
20 max.
CA12-2N
Adjustable roller lever: R25 to 89 mm
CL-2N Adjustable rod lever: 25 to 140 mm
G2 Roller lever, high sensitivity: R38 mm *1
10°
G12
Adjustable roller lever, high sensitivity: R25 to 89 mm *1
GL Adjustable rod lever, high sensitivity: 25 to 140 mm *1
GCA2 Roller lever, high precision: R38 mm *1 5°
CA32-41 Fork lever lock
55 max.
CA32-42 Fork lever lock
CA32-43 Fork lever lock
D18 Sealed top plunger
1.7 mm max.
D28 Sealed top-roller plunger
D38 Sealed top-ball plunger
D2 Top-roller plunger
SD Horizontal plunger
2.8 mm max.
SD2 Horizontal-roller plunger
SD3 Horizontal-ball plunger
NJ Flexible rod: Coil spring 20±10 mm
NJ-30 Flexible rod: Coil spring, multi-wire
NJ-2 Flexible rod: Resin rod 40±20 mm
NJ-S2 Flexible rod: Steel wire
Code Specifications
Blank Standard
RP Corrosion-proof
P1 Weather-proof
Code Specifications
Blank Standard built-in switch
55 Airtight built-in switch
Code Specifications
Blank Standard: 10°C to +80°C
TH Heat-resistant: +5°C to +120°C *2
TC Low-temperature: 40°C to +40°C *2
+2°
1°
+2
0
Code Specifications
Blank No cable molding.
139
Standard built-in switch. Cable is attached.
Molded conduit opening and cover. (The cover cannot be re-
moved.)
140
Airtight built-in switch. Cable is attached.
Molded conduit opening, cover, and cover screws. (The cover
cannot be removed.)
141
Airtight built-in switch. Cable is attached.
Molded conduit opening, cover, head, cover screws, and head
screws. (The cover cannot be removed and the head direction
cannot be changed.)
Double seal against oil including head cap countermeasure for
cutting chips and an oil seal.
145
Airtight built-in switch. Cable is attached.
Molded conduit opening, cover, and cover screws. (The cover
cannot be removed. The head can be mounted in any of 4 di-
rections.)
Double seal against oil including head cap countermeasure for
cutting chips and an oil seal.
RP40
Airtight built-in switch. Cable is attached.
Molded conduit opening and cover. (The cover cannot be re-
moved.)
SC Connector can be removed, so it is possible to use flexible
conduits for the cable.
RP60
Airtight built-in switch. Cables are attached.
Molded conduit opening, cover, cover screws, and head
screws. (The cover cannot be removed and the head direction
cannot be changed.)
Fluorine rubber is used for all rubber parts.
Code Specifications
Conduit Size Ground terminal
Blank G1/2 None
G1 G1/2
Provided *3
G Pg13.5
YM20
TS 1/2-14NPT
Code Specifications
Blank No indicator
LE Neon lamp: 125 to 250 VAC *4
LD LED (10 to 115 VAC/DC) *4
Code Specifications
2 NC connection: Light-ON when operating *5
3 NO connection: Light-ON when not operating *5
Code Specifications
Blank Standard lever (Allen-head bolt)
A Double nut lever
WL-N/WLM-N
11
Model Number Legend (Not all combinations are possible. Contact your OMRON representative for details.)
(1) Actuator and Property Specifications
*1. Manufacturing has been discontinued.
The high-sensitivity, high-precision models have been integrated
into the WL Series. Refer to the model replacement table on page
45 and order high-sensitivity and high-precision models with the
WL model numbers.
(2) Built-in Switch Type
(3) Indicator Type
*2. Cannot be combined with a Switch with a Connector.
(4) Connector Type
*3. DC models are certified for EN/IEC (CE Marking).
*4. Refer to Contact Forms on page 16 for details on connector pin numbers.
*5. The standard cable length is 0.3 m. Contact your OMRON representative for information on other cable lengths.
Spatter-prevention Switches
Code Lever Pretravel (PT)
CA2 Roller lever: R38 mm 15±5°
G2 Roller lever, high sensitivity: R38 mm *1 10°
GCA2 Roller lever, high precision: R38 mm *1 5°
D28 Sealed top-roller plunger 1.7 mm max.
Code Specifications
Blank Standard built-in switch
55 Airtight built-in switch
Code Specifications
LE Neon lamp: 125 to 250 VAC *2
LD LED (10 to 115 VAC/DC)
+2°
1°
+2
0
Code Specifications
Shape Voltage *3 Wiring locations Connector pin No. *4
Blank No connector ---- ---- ---- ----
-M1J-1
Pre-wired Connector *5 Threaded (M12)
DC NO only NO:
-M1GJ-1 DC NO only NO:
-DGJS DC NC+NO NC: , NO:
-DTGJS Smartclick DC NC+NO NC: , NO:
3 4
1 4
1 2
3 4
1 2
3 4
WL-N/WLM-N
12
Model Number Legend (Not all combinations are possible. Contact your OMRON representative for details.)
(1) Actuator and Property Specifications
*1. Manufacturing has been discontinued.
The high-sensitivity, high-precision models have been integrated
into the WL Series. Refer to the model replacement table on page
45 and order high-sensitivity and high-precision models with the
WL model numbers.
(2) Indicator Type
(3) Connector Type
*2. The standard cable length is 0.3 m. Contact your OMRON representative for information on other cable lengths.
Long-life Switches
Code Lever Pretravel (PT)
CA2 Roller lever: R38 mm 15±5°
G2 Roller lever, high sensitivity: R38 mm *1 10°
GCA2 Roller lever, high precision: R38 mm *1 5°
Code Specifications
LD LED (10 to 115 VAC/DC)
+2°
1°
+2
0
Code Specifications
Shape Voltage Wiring locations Connector pin No.
Blank Screw terminals: G1/2 conduit ---- ---- ---- ----
K13A
Direct-wired connector Threaded (M12)
AC NO only NO:
K13 DC NO only NO:
K43A AC NC+NO NC: , NO:
K43 DC NC+NO NC: , NO:
-M1J
Pre-wired connector *2
Threaded (M12)
DC NO only NO:
-AGJ AC NC+NO NC: , NO:
-DGJ DC NC+NO NC: , NO:
-M1TJ Smartclick DC NO only NO:
-DTGJ DC NC+NO NC: , NO:
3 4
3 4
1 2
3 4
1 2
3 4
3 4
1 2
3 4
1 2
3 4
3 4
1 2
3 4
WL-N/WLM-N
13
Ordering Information
Switches with Lever Actuators
Switches with Plunger Actuators
Switches with Flexible Rod Actuators
* Manufacturing has been discontinued. The high-sensitivity, high-precision models have been integrated into the WL Series.
Refer to the model replacement table on page 45 and order high-sensitivity and high-precision models with the WL model numbers.
General-purpose Switches
Actuator Roller lever R38 Roller lever: R50 Roller lever: R63
Item Pretravel (PT) Model Model Model
Basic
15±5°WLCA2-N WLCA2-7-N WLCA2-8-N
25±5°WLCA2-2-N ----- -----
20° max. WLCA2-2N-N ----- -----
High-sensitivity 10°* (WLG2-N) ----- -----
High-precision 5°* (WLGCA2-N) ----- -----
Actuator Adjustable roller lever Adjustable rod lever:
25 to 140 mm
Adjustable rod lever:
350 to 380 mm Rod spring lever
Item Pretravel (PT) Model Model Model Model
Basic
15±5°WLCA12-N WLCL-N WLCAL4-N WLCAL5-N
25±5°
WLCA12-2-N
WLCL-2-N ----- -----
20° max.
WLCA12-2N-N
WLCL-2N-N ----- -----
High-sensitivity 10°* (WLG12-N) * (WLGL-N) ----- -----
Actuator Fork lever lock Fork lever lock Fork lever lock Fork lever lock
Item Pretravel (PT) Model Model Model Model
Protective 55° max.
WLCA32-41-N WLCA32-42-N WLCA32-43-N WLCA32-44-N
Actuator Sealed top plunger Sealed top-roller
plunger
Sealed top-ball
plunger Top-roller plunger
Item Pretravel (PT) Model Model Model Model
Basic 1.7 mm max. WLD18-N WLD28-N WLD38-N WLD2-N
Actuator Horizontal plunger Horizontal-roller
plunger
Horizontal-ball
plunger
Item Pretravel (PT) Model Model Model
Basic 2.8 mm max. WLSD-N WLSD2-N WLSD3-N
Actuator Coil spring
(spring diameter: 6.5)
Coil spring
(spring diameter: 4.8)
Item Pretravel (PT) Model Model
Basic 20±10 mm WLNJ-N WLNJ-30-N
Actuator Resin rod
(rod diameter: 8)
Steel wire
(wire diameter: 1)
Item Pretravel (PT) Model Model
Basic 40±20 mm WLNJ-2-N WLNJ-S2-N
Standard Switches
+2°
-1°
+2°
0°
+2°
-1°
WL-N/WLM-N
14
Switches with Lever Actuators
Switches with Plunger Actuators
Switches with Flexible Rod Actuators
*1. The default setting is light-ON when not operating (NO wiring). Turn the lamp holder by 180° to change the setting to light-ON when operating
(NC wiring).
*2. Manufacturing has been discontinued. The high-sensitivity, high-precision models have been integrated into the WL Series.
Refer to the model replacement table on page 45 and order high-sensitivity and high-precision models with the WL model numbers.
General-purpose Switches
Operation Indicator Switches *1
Actuator Roller lever: R38 Roller lever: R50 Roller lever: R63
Indicator Item Pretravel (PT) Model Model Model
Neon lamp
Basic
15±5°WLCA2-LE-N WLCA2-7LE-N WLCA2-8LE-N
25±5°WLCA2-2LE-N ----- -----
20° max. WLCA2-2NLE-N ----- -----
High-sensitivity 10°*2 (WLG2-LE-N) ----- -----
High-precision 5°*2 (WLGCA2-LE-N) ----- -----
LED
Basic
15±5°WLCA2-LD-N WLCA2-7LD-N WLCA2-8LD-N
25±5°WLCA2-2LD-N ----- -----
20° max. WLCA2-2NLD-N ----- -----
High-sensitivity 10°*2 (WLG2-LD-N) ----- -----
High-precision 5°*2 (WLGCA2-LD-N) ----- -----
Actuator Adjustable roller lever: Adjustable rod lever:
25 to 140 mm
Adjustable rod lever:
350 to 380 mm Rod spring lever
Indicator Item Pretravel (PT) Model Model Model Model
Neon lamp Basic
15±5°WLCA12-LE-N WLCL-LE-N WLCAL4-LE-N WLCAL5-LE-N
25±5°WLCA12-2LE-N WLCL-2LE-N ----- -----
20° max. WLCA12-2NLE-N WLCL-2NLE-N ----- -----
High-sensitivity 10°*2 (WLG12-LE-N) *2 (WLGL-LE-N) ----- -----
LED Basic
15±5°WLCA12-LD-N WLCL-LD-N WLCAL4-LD-N WLCAL5-LD-N
25±5°WLCA12-2LD-N WLCL-2LD-N ----- -----
20° max. WLCA12-2NLD-N WLCL-2NLD-N ----- -----
High-sensitivity 10°*2 (WLG12-LD-N) *2 (WLGL-LD-N) ----- -----
Actuator Fork lever lock Fork lever lock Fork lever lock
Indicator Item Pretravel (PT) Model Model Model
Neon lamp Basic 55° max. WLCA32-41LE-N WLCA32-42LE-N WLCA32-43LE-N
LED Basic 55° max. WLCA32-41LD-N ----- WLCA32-43LD-N
+2°
-1°
+2°
0°
+2°
-1°
+2°
0°
+2°
-1°
+2°
-1°
Actuator Sealed top plunger Sealed top-roller
plunger
Sealed top-ball
plunger Top-roller plunger
Indicator Item Pretravel (PT) Model Model Model Model
Neon lamp Basic 1.7 mm max. WLD18-LE-N WLD28-LE-N WLD38-LE-N WLD2-LE-N
LED Basic 1.7 mm max. WLD18-LD-N WLD28-LD-N WLD38-LD-N WLD2-LD-N
Actuator Horizontal plunger Horizontal-roller
plunger
Horizontal-ball
plunger
Indicator Item Pretravel (PT) Model Model Model
Neon lamp Basic 2.8 mm max. WLSD-LE-N WLSD2-LE-N WLSD3-LE-N
LED Basic 2.8 mm max. WLSD-LD-N WLSD2-LD-N WLSD3-LD-N
Actuator Coil spring
(spring
diameter: 6.5)
Coil spring
(spring
diameter: 4.8)
Indicator Item Pretravel
(PT) Model Model
Neon lamp
Basic 20±10 mm WLNJ-LE-N WLNJ-30LE-N
LED Basic 20±10 mm WLNJ-LD-N WLNJ-30LD-N
Actuator Resin rod
(rod
diameter: 8)
Steel wire
(wire
diameter: 1)
Indicator Item Pretravel
(PT) Model Model
Neon lamp
Basic 40±20 mm WLNJ-2LE-N WLNJ-S2LE-N
LED Basic 40±20 mm WLNJ-2LD-N WLNJ-S2LD-N
WL-N/WLM-N
15
Switches with Direct-wired Connectors
Note: The default setting is light-ON when not operating (NO wiring).
Turn the lamp holder by 180
°
to change the setting to light-ON when operating (NC wiring).
(However, Four-core Switches cannot be switched to light-ON when operating (NC wiring).)
* Manufacturing has been discontinued. The high-sensitivity, high-precision models have been integrated into the WL Series.
Refer to the model replacement table on page 45 and order high-sensitivity and high-precision models with the WL model numbers.
Switches with Pre-wired Connectors
Note: 1. The standard cable length for a pre-wired connector is 0.3 m. Contact your OMRON representative for information on other cable lengths.
2. The default setting is light-ON when not operating (NO wiring).
Turn the lamp holder by 180
°
to change the setting to light-ON when operating (NC wiring).
(However, Three-core and Four-core Switches cannot be switched to light-ON when operating (NC wiring).)
* Manufacturing has been discontinued. The high-sensitivity, high-precision models have been integrated into the WL Series.
Refer to the model replacement table on page 45 and order high-sensitivity and high-precision models with the WL model numbers.
General-purpose Switches
Actuator Roller lever: R38
Item Basic High-sensitivity High-precision
Connector
shape
Built-in switch
type Voltage Wiring
locations
Connector
pin No. Model Model Model
Threaded
(M12)
General-purpose
AC
NO only 2 core NO WLCA2-LDK13A-N ----- -----
NC + NO 4 core NC
NO WLCA2-LDK43A-N ----- -----
DC
NO only 2 core NO WLCA2-LDK13-N * (WLG2-LDK13-N) * (WLGCA2-LDK13-N)
NC + NO 4 core NC
NO WLCA2-LDK43-N * (WLG2-LDK43-N) * (WLGCA2-LDK43-N)
Airtight AC
NO only 2 core NO
WLCA2-55LDK13-N
* (WLG2-55LDK13-N) * (
WLGCA2-55LDK13-N)
NC + NO 4 core NC
NO
WLCA2-55LDK43-N
* (WLG2-55LDK43-N) * (
WLGCA2-55LDK43-N)
Actuator Roller lever R38
Item Basic High-sensitivity High-precision
Connector
shape
Built-in switch
type Voltage Wiring
locations
Connector
pin No. Model Model Model
Threaded
(M12)
General-purpose
DC
NO only 2 core NO WLCA2-LD-M1J-N * (WLG2-LD-M1J-N) * (WLGCA2-LD-M1J-N)
NO WLCA2-LD-M1GJ-N * (WLG2-LD-M1GJ-N)
*
(WLGCA2-LD-M1GJ-N)
NC only 2 core NC WLCA2-LD-M1JB-N * (WLG2-LD-M1JB-N) -----
NC + NO 4 core NC
NO WLCA2-LD-DGJ-N * (WLG2-LD-DGJ-N) * (WLGCA2-LD-DGJ-N)
NO only 3 core NO
NC WLCA2-LD-DK1EJ-N * (WLG2-LD-DK1EJ-N) -----
Airtight
NO only 2 core NO WLCA2-55LD-M1J-N -----
*
(WLGCA2-55LD-M1J-
N)
NO
WLCA2-55LD-M1GJ-N
*
(WLG2-55LD-M1GJ-N)
*
(WLGCA2-55LD-M1GJ-N)
NC only 2 core NC
WLCA2-55LD-M1JB-N
*
(WLG2-55LD-M1JB-N)
*
(WLGCA2-55LD-M1JB-N)
NC + NO 4 core NC
NO WLCA2-55LD-DGJ-N * (WLG2-55LD-DGJ-N)
*
(WLGCA2-55LD-DGJ-N)
NO only 3 core NO
NC
WLCA2-55LD-DK1EJ-N
* (
WLG2-55LD-DK1EJ-
N) -----
Smartclick General-purpose NO only 2 core NO ----- * (WLG2-LD-M1TJ-N) -----
NO only 2 core NC ----- * (WLG2-LD-M1TJB-N) -----
Sensor I/O Connector Switches
3 4
1 2
3 4
3 4
1 2
3 4
3 4
1 2
3 4
3 4
1 4
2 3
1 2
3 4
4 3
2
3 4
1 4
2 3
1 2
3 4
4 3
2
3 4
2 3
WL-N/WLM-N
16
Contact Forms
Screw Terminal Switches Screw Terminal Switches
Indicator-equipped (Light-ON when Not Operating) Switches *1
Direct-wired Connectors/Pre-wired Connectors
Indicator-equipped (Light-ON when Not Operating) Switches *1
Note:
Leakage current from indicator circuit may cause load malfunction (i.e., the load may remain ON). Make sure that the load operating current is higher
than the leakage current. For countermeasures, refer to technical support on your OMRON website.
*1. Light-ON when not operating means the indicator is lit when the actuator is free and is not light when the Switch contacts (NO) close when the
actuator rotates or is pushed down.
*2. The position of the positioning piece is not always the same. If using an L-shaped connector causes problems in application, use a straight connector.
Connecting Sensor I/O connector cable (Socket)
13 (NO)
12 (NC)
14 (NO)
11 (NC)
Za
13 (NO)
12 (NC)
14 (NO)
11 (NC)
Internal
circuits
Za
NONCNCNO
4
Internal
circuits
3
4
WL@-@K13A-N
WL@-@K43A-N
WL@-@-AGJ-N
1
1
13
3
4
1
2
2
4
2 3 4
2 3
NONCNCNO
4
Internal
circuits
3
4 1
3 2
4
WL@-@K13-N
WL@-@-M1J-N
WL@-@-M1TJ-N
WL@-@-M1GJ-N
WL@-@-M1TGJ-N
WL@-@-M1JB-N
WL@-@-M1TJB-N
WL@-@K43-N
WL@-@DGJ-N
WL@-@DTGJ-N
1 2 3
AC DC
AC DC
Za Za
indicate the connector pin number.
1 2 3 4
indicate the connector pin number.
Positioning piece *2
Connector Pin Layout Diagram
Positioning piece *2
Type AC/DC Type Number of cable cores Cable length
L (m) Model Applicable limit switch models
M12 Screw (Straight)
AC
22 m XS2F-A421-DB0-F WL@-@K13A-N
5 m XS2F-A421-GB0-F
42 m XS2F-A421-D90-F WL@-@K43A-N
WL@-@-AGJ-N
5 m XS2F-A421-G90-F
DC
2
2 m XS2F-D421-DD0 WL@-@K13-N
WL@-@-M1J-N
5 m XS2F-D421-GD0
2 m XS2F-D421-DA0-F WL@-@-M1GJ@-N
5 m XS2F-D421-GA0-F
42 m XS2F-D421-D80-F WL@-@K43-N
WL@-@-M1JB-N
WL@-@DGJ-N
5 m XS2F-D421-G80-F
M12 Smart click type (Straight)
DC 4
2 m XS5F-D421-D80-F WL@-@-M1TJ-N
WL@-@-M1TJB-N
5 m XS5F-D421-G80-F
WL-N/WLM-N
17
Dimensions (Unit: mm)
XS2F-@421-@@0-@
XS2F-D421-@D0
Wiring Diagram
XS5F-D421-@80-F
AC/DC Type Two-core model Four-core model
Model Wiring Diagram Model Wiring Diagram
AC XS2F-A421-DB0-F
XS2F-A421-GB0-F
XS2F-A421-D90-F
XS2F-A421-G90-F
DC
XS2F-D421-DD0
XS2F-D421-GD0
XS2F-D421-D80-F
XS2F-D421-G80-F
XS2F-D421-DA0-F
XS2F-D421-GA0-F
6 dia.
50
30 5
40.7
L (Cable length)
DC AC
14.9 dia.
1
2
3
4
Brown
Blue
Terminal No. Cable color of
core sheath
1
2
3
4
Blue
Black
Brown
White
Terminal No. Cable color of
core sheath
1
2
3
4
Blue
Brown
Terminal No. Cable color of
core sheath
Brown
Blue
Terminal No. Cable color of
core sheath
1
2
3
4
Wiring Diagram
AC/DC Type Four-core model
Model Wiring Diagram
DC XS5F-D421-D80-F
XS5F-D421-G80-F
1
2
3
4
Blue
Black
Brown
White
Terminal No. Cable color of
core sheath
6 dia.
40.7
L (Cable length)
50
30
14.9 dia.
5
WL-N/WLM-N
18
Note: The maximum cable length for a Hermetic Switch is 5 m.
* Manufacturing has been discontinued. The high-sensitivity, high-precision models have been integrated into the WL Series.
Refer to the model replacement table on page 45 and order high-sensitivity and high-precision models with the WL model numbers.
Environment-resistant Switches
Actuator Roller lever R38
Adjustable roller lever
Adjustable rod lever
25 to 140 mm
Item
Pretravel (PT)
Model Model Model
Airtight seal
Basic
15±5°WLCA2-55-N WLCA12-55-N WLCL-55-N
25±5°WLCA2-255-N ----- -----
20° max. WLCA2-2N55-N ----- -----
High-sensitivity 10°* (WLG2-55-N) ----- -----
High-precision 5°* (WLGCA2-55-N) ----- -----
Hermetic
seal
Molded
terminals,
-139 models
Basic
15±5°WLCA2-139-N WLCA12-139-N WLCL-139-N
25±5°WLCA2-2139-N ----- -----
20° max. WLCA2-2N139-N ----- -----
High-sensitivity 10°* (WLG2-139-N) ----- -----
High-precision 5°* (WLGCA2-139-N) ----- -----
Molded
terminals,
-140 models
Basic
15±5°WLCA2-140-N WLCA12-140-N WLCL-140-N
25±5°----- ----- -----
20° max. WLCA2-2N140-N ----- -----
High-sensitivity 10°* (WLG2-140-N) ----- -----
High-precision 5°----- ----- -----
Molded
terminals,
-141 models
Basic
15±5°WLCA2-141-N WLCA12-141-N -----
25±5°----- ----- -----
20° max. ----- ----- -----
High-sensitivity 10°* (WLG2-141-N) ----- -----
High-precision 5°* (WLGCA2-141-N) ----- -----
Anti-coolant
Basic
15±5°WLCA2-RP60-N WLCA12-RP60-N WLCL-RP60-N
25±5°WLCA2-2RP60-N ----- -----
20° max. ----- ----- -----
High-sensitivity 10°* (WLG2-RP60-N) ----- -----
High-precision 5°* (WLGCA2-RP60-N) ----- -----
Heat-resistant
Basic
15±5°WLCA2-TH-N WLCA12-TH-N WLCL-TH-N
25±5°WLCA2-2TH-N WLCA12-2TH-N WLCL-2TH-N
20° max. WLCA2-2NTH-N WLCA12-2NTH-N WLCL-2NTH-N
High-sensitivity 10°* (WLG2-TH-N) * (WLG12-TH-N) * (WLGL-TH-N)
High-precision 5°* (WLGCA2-TH-N) ----- -----
Low-temperature
Basic
15±5°WLCA2-TC-N WLCA12-TC-N WLCL-TC-N
25±5°WLCA2-2TC-N WLCA12-2TC-N WLCL-2TC-N
20° max. WLCA2-2NTC-N WLCA12-2NTC-N WLCL-2NTC-N
High-sensitivity 10°* (WLG2-TC-N) * (WLG12-TC-N) * (WLGL-TC-N)
High-precision 5°* (WLGCA2-TC-N) ----- -----
Corrosion-proof
Basic
15±5°WLCA2-RP-N WLCA12-RP-N WLCL-RP-N
25±5°----- ----- -----
20° max. ----- ----- -----
High-sensitivity 10°* (WLG2-RP-N) ----- -----
High-precision 5°* (WLGCA2-RP-N) ----- -----
Weather-proof Basic
15±5°WLCA2-P1-N WLCA12-P1-N WLCL-P1-N
25±5°----- -----
20° max. ----- -----
High-sensitivity 10°* (WLG2-P1-N) * (WLG12-P1-N) * (WLGL-P1-N)
Standard Switches
+2°
-1°
+2°
0°
+2°
-1°
+2°
0°
+2°
-1°
+2°
0°
+2°
-1°
+2°
0°
+2°
-1°
+2°
0°
+2°
-1°
+2°
0°
+2°
-1°
+2°
0°
+2°
-1°
+2°
0°
+2°
-1°
WL-N/WLM-N
19
Note: The maximum cable length for a Hermetic Switch is 5 m.
Note: The maximum cable length for a Hermetic Switch is 5 m.
Actuator
Sealed top-roller
plunger Top-roller plunger Horizontal plunger Horizontal-roller
plunger
Model Model Model Model
Airtight WLD28-55-N WLD2-55-N WLSD-55-N WLSD2-55-N
Hermetic
Molded
terminals,
-139 models
WLD28-139-N WLD2-139-N WLSD-139-N WLSD2-139-N
Molded
terminals,
-140 models
WLD28-140-N ----- ----- WLSD2-140-N
Anti-coolant WLD28-RP60-N WLD2-RP60-N WLSD-RP60-N WLSD2-RP60-N
Heat-resistant WLD28-TH-N WLD2-TH-N WLSD-TH-N WLSD2-TH-N
Low-temperature ----- ----- WLSD-TC-N WLSD2-TC-N
Corrosion-proof WLD28-RP-N ----- WLSD-RP-N WLSD2-RP-N
Actuator
Coil spring
(spring diameter: 6.5)
Resin rod
(rod diameter: 8)
Model Model
Airtight WLNJ-55-N WLNJ-255-N
Hermetic
Molded
terminals,
-139 models
WLNJ-139-N WLNJ-2139-N
Molded
terminals,
-140 models
WLNJ-140-N WLNJ-2140-N
Anti-coolant WLNJ-RP60-N WLNJ-2RP60-N
Heat-resistant WLNJ-TH-N -----
Low-temperature WLNJ-TC-N -----
Corrosion-proof WLNJ-RP-N WLNJ-2RP-N
WL-N/WLM-N
20
Airtight Switches
*1. The default setting is light-ON when not operating (NO wiring).
Turn the lamp holder by 180
°
to change the setting to light-ON when operating (NC wiring).
*2. Manufacturing has been discontinued. The high-sensitivity, high-precision models have been integrated into the WL Series.
Refer to the model replacement table on page 45 and order high-sensitivity and high-precision models with the WL model numbers.
Hermetic Switches
Note: The maximum cable length for a Hermetic Switch is 5 m.
* Manufacturing has been discontinued. The high-sensitivity, high-precision models have been integrated into the WL Series.
Refer to the model replacement table on page 45 and order high-sensitivity and high-precision models with the WL model numbers.
Environment-resistant Switches
Actuator Roller lever: R38 Adjustable roller lever Adjustable rod lever:
25 to 140 mm
Indicator Item Pretravel (PT) Model Model Model
Neon lamp
Basic
15±5°WLCA2-55LE-N WLCA12-55LE-N -----
25±5°WLCA2-255LE-N ----- -----
20° max. WLCA2-2N55LE-N ----- -----
High-sensitivity 10°*2 (WLG2-55LE-N) ----- -----
High-precision 5°*2 (WLGCA2-55LE-N) ----- -----
LED
Basic
15±5°WLCA2-55LD-N WLCA12-55LD-N WLCL-55LD-N
25±5°WLCA2-255LD-N ----- -----
20° max. WLCA2-2N55LD-N ----- -----
High-sensitivity 10°*2 (WLG2-55LD-N) ----- -----
High-precision 5°*2 (WLGCA2-55LD-N) ----- -----
Actuator Sealed top-roller
plunger Top-roller plunger Horizontal plunger Horizontal-roller
plunger
Indicator Item Model Model Model Model
Neon lamp Basic WLD28-55LE-N WLD2-55LE-N ----- -----
LED Basic WLD28-55LD-N WLD2-55LD-N WLSD-55LD-N WLSD2-55LD-N
Actuator Coil spring
(spring diameter: 6.5)
Resin rod
(rod diameter: 8)
Indicator Item Model Model
Neon lamp Basic ----- -----
LED Basic WLNJ-55LD-N WLNJ-255LD-N
Actuator Roller lever: R38
Wiring specification
NC wiring NO wiring
Item Pretravel (PT) Model Model
Molded
terminals,
-139 models
Basic
15±5°WLCA2-139LD2-N WLCA2-139LD3-N
25±5°WLCA2-2139LD2-N WLCA2-2139LD3-N
20° max. ----- -----
High-sensitivity 10°----- * (WLG2-139LD3-N)
High-precision 5°* (WLGCA2-139LD2-N) * (WLGCA2-139LD3-N)
Molded
terminals,
-141 models
Basic
15±5°WLCA2-141LD2-N WLCA2-141LD3-N
25±5°----- -----
20° max. ----- -----
High-sensitivity 10°* (WLG2-141LD2-N) * (WLG2-141LD3-N)
High-precision 5°----- -----
Anti-coolant
Basic
15±5°WLCA2-RP60LD2-N WLCA2-RP60LD3-N
25±5°WLCA2-2RP60LD2-N WLCA2-2RP60LD3-N
20° max. ----- -----
High-sensitivity 10°* (WLG2-RP60LD2-N) * (WLG2-RP60LD3-N)
High-precision 5°* (WLGCA2-RP60LD2-N) * (WLGCA2-RP60LD3-N)
Operation indicator Switches *1
+2°
-1°
+2°
0°
+2°
-1°
+2°
0°
+2°
-1°
+2°
0°
+2°
-1°
+2°
0°
+2°
-1°
+2°
0°
WL-N/WLM-N
21
*1. The default setting is light-ON when not operating (NO wiring).
Turn the lamp holder by 180
°
to change the setting to light-ON when operating (NC wiring).
*2. Manufacturing has been discontinued. The high-sensitivity, high-precision models have been integrated into the WL Series.
Refer to the model replacement table on page 45 and order high-sensitivity and high-precision models with the WL model numbers.
*3. The default setting is light-ON when not operating (NO wiring).
Turn the lamp holder by 180
°
to change the setting to light-ON when operating (NC wiring).
(However, Four-core Switches cannot be switched to light-ON when operating (NC wiring).)
*4. With 0.3-m cable.
*5. Manufacturing has been discontinued. The high-sensitivity, high-precision models have been integrated into the WL Series.
Refer to the model replacement table on page 45 and order high-sensitivity and high-precision models with the WL model numbers.
Spatter-prevention Switches *1
Actuator Roller lever: R38
Sealed top-roller
plunger
Double Nut Lever Allen-head Lever
Indicator Item Pretravel (PT) Model Model Model
Neon lamp
Basic 15±5°WLCA2-LEAS-N WLCA2-LES-N WLD28-LES-N
High-sensitivity 10°*2 (WLG2-LEAS-N) *2 (WLG2-LES-N) -----
High-precision 5°----- *2 (WLGCA2-LES-N) -----
LED
Basic 15±5°WLCA2-LDAS-N WLCA2-LDS-N WLD28-LDS-N
High-sensitivity 10°*2 (WLG2-LDAS-N) *2 (WLG2-LDS-N) -----
High-precision 5°----- *2 (WLGCA2-LDS-N) -----
Long-life Switches *3
Item Operation indicator (LED)
Basic 15±5°High-sensitivity 10°High-precision 5°
Actuator Model Model Model
WLMCA2-LD-N *5 (WLMG2-LD-N) *5 (WLMGCA2-LD-N)
2 conductors AC WLMCA2-LDK13A-N
*5 (WLMG2-LDK13A-N)
*5 (WLMGCA2-LDK13A-N)
DC WLMCA2-LDK13-N *5 (WLMG2-LDK13-N)
*5 (WLMGCA2-LDK13-N)
4 conductors
AC WLMCA2-LDK43A-N
*5 (WLMG2-LDK43A-N)
-----
DC WLMCA2-LDK43-N *5 (WLMG2-LDK43-N)
*5 (WLMGCA2-LDK43-N)
2 conductors DC WLMCA2-LD-M1J-N *5 (WLMG2-LD-M1J-N)
*5 (WLMGCA2-LD-M1J-N)
4 conductors DC WLMCA2-LD-DGJ-N
*5 (WLMG2-LD-DGJ-N)
-----
+2°
-1°
+2°
0°
+2°
-1°
+2°
0°
+2°
-1°
+2°
0°
Roller lever: R38,
screw terminals
Roller lever,
direct-wired
connector
Roller lever,
pre-wired connector
*4
WL-N/WLM-N
22
Individual Parts
Switches without Levers, Heads, and Actuators
General-purpose Parts
*1. The heads are not compatible with WL-series Switches.
*2. The same Actuators can be used for both WL and WL-N Switches.
*3. Manufacturing has been discontinued. The high-sensitivity, high-precision models have been integrated into the WL Series.
Refer to the model replacement table on page 45 and order high-sensitivity and high-precision models with the WL model numbers.
Spatter-prevention Parts
*1. The same Actuators can be used for both WL and WL-N Switches.
*2. Manufacturing has been discontinued. The high-sensitivity, high-precision models have been integrated into the WL Series.
Refer to the model replacement table on page 45 and order high-sensitivity and high-precision models with the WL model numbers.
Covers with Indicators (See Note.)
General-purpose Parts
Note: 1. The Covers are not compatible with WL-series Switches.
2. The default setting is for light-ON when not operating.
Turn the lamp holder by 180° to change the setting to light-
ON when operating.
Spatter-prevention Parts
Actuator Item Pretravel (PT) Set
Switch without
levers
Head *1
(with Actuators) Actuator only *2
Model Model Model
Roller lever Basic
15±5°WLCA2-N WLRCA2-N
WL-1H1100-N
WL-1A100
25±5°WLCA2-2-N
WLRCA2-2-N WL-3H1100-N
20° max. WLCA2-2N-N
WLRCA2-2N-N
WL-1H1100-N
High-sensitivity 10°*3 (WLG2-N) *3 (WLRG2-N)
*3 (WL-2H1100-N)
Adjustable roller
lever
Basic
15±5°WLCA12-N WLRCA2-N
WL-1H2100-N
WL-2A100
25±5°WLCA12-2-N
WLRCA2-2-N WL-3H2100-N
20° max. WLCA12-2N-N
WLRCA2-2N-N
WL-1H2100-N
High-sensitivity 10°*3 (WLG12-N) *3 (WLRG2-N)
*3 (WL-2H2100-N)
Variable rod lever Basic
15±5°WLCL-N WLRCL-N
WL-4H4100-N
WL-4A100
25±5°WLCL-2-N
WLRCA2-2-N WL-3H4100-N
20° max. WLCL-2N-N
WLRCA2-2N-N
WL-1H4100-N
High-sensitivity 10°*3 (WLGL-N) *3 (WLRG2-N)
*3 (WL-2H4100-N)
Fork lever lock Basic 55° max.
WLCA32-41-N
WLRCA32-N
WL-5H5100-N
WL-5A100
WLCA32-42-N
WL-5H5102-N
WL-5A102
WLCA32-43-N
WL-5H5104-N
WL-5A104
WLCA32-44-N
WL-5H5104-N
WL-5A104
Top plunger Basic 1.7 mm max.
WLD18-N
-----
WL-7H100-N -----
WLD28-N WL-7H400-N -----
WLD38-N WL-7H300-N -----
Horizontal plunger Basic 2.8 mm max.
WLSD-N
-----
WL-8H100-N -----
WLSD2-N WL-8H200-N -----
WLSD3-N WL-8H300-N -----
Flexible rod Basic
20±10 mm WLNJ-N
-----
WL-9H100-N -----
WLNJ-30-N WL-9H200-N -----
40±20 mm WLNJ-2-N WL-9H300-N -----
WLNJ-S2-N WL-9H400-N -----
+2°
-1°
+2°
-1°
+2°
-1°
Actuator Lever Type Item Set
Switch without
levers
Head
(with Actuators) Actuator only *1
Model Model Model
Roller lever
Allen-head bolt
lever
Basic WLCA2-LES-N WLRCA2-LES-N
WL-1H1100S-N WL-1A103SWLCA2-LDS-N WLRCA2-LDS-N
High-sensitivity *2 (WLG2-LDS-
N) *2 (WLRG2-LDS-N)
Double nut lever Basic WLCA2-LEAS-N WLRCA2-LES-N
WL-2H1100S-N WL-1A105SWLCA2-LDAS-N WLRCA2-LDS-N
High-sensitivity
*2 (WLG2-LDAS-N) *2 (WLRG2-LDS-N)
Cover Cover only
Item Color Model
Neon lamp Orange WL-LE-N *
LED Red WL-LD-N
Yellow WL-LW-N *
Cover Cover only
Item Color Model
Neon lamp Orange WL-LES-N
LED Red WL-LDS-N
* The Color Universal Design structure is certified by an NPO.
Certification conditions: Ambient illumination of 500 lx max.
(JIS Z 9110)
Color Universal Design was developed in consideration of people
with various types of color vision to allow information to be accurately
conveyed to as many individuals as possible.
WL-N/WLM-N
23
Specifications
Ratings
Screw Terminals
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a
time constant of 7 ms max. (DC).
3.
A lamp load has an inrush current of 10 times the steady-state current.
4.
A motor load has an inrush current of 6 times the steady-state current.
5. For PC loads, use the microload models.
*1.
Manufacturing of the high-sensitivity, high-precision models has
been discontinued and the models have been integrated into the
WL Series. This information is provided as reference for
comparison of specifications. Refer to the model replacement
table on page 45 and order WL-series high-sensitivity or high-
precision models.
*2. For high-sensitivity and high-precision switches.
Operation indicator Switches
Direct-wired Connector and Pre-wired Connector Switches
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a
time constant of 7 ms max. (DC).
3.
A lamp load has an inrush current of 10 times the steady-state current.
4.
A motor load has an inrush current of 6 times the steady-state current.
* Manufacturing of the high-sensitivity, high-precision models has been
discontinued and the models have been integrated into the WL Series.
This information is provided as reference for comparison of
specifications. Refer to the model replacement table on page 45 and
order WL-series high-sensitivity or high-precision models.
Characteristics
Note: 1. The above figures are initial values.
2. The figures in parentheses for dielectric strength are those
for the high-sensitivity and high-precision switches models.
*1. The values are calculated at an operating temperature of +5°C to
+35°C and an operating humidity of 40% to 70% RH. Contact your
OMRON sales representative for more detailed information on
other operating environments.
*2. High-sensitivity Switches and Switches with Flexible Rod
Actuators: 10 million operations min.
500,000 operations min. for weather-proof models.
*3. Durability is 500,000 operations min. for high-sensitivity and high-
precision models.
500,000 operations min. for weather-proof models.
Contact your OMRON representative for information on
Environment-resistant model and Hermetic models.
*4. Switches with Connectors: 1,500 V.
*5. Except Switches with Flexible Rod Actuators.
*6. For low-temperature models this is -40°C to +40°C (with no icing).
For heatresistant models the range is +5°C to +120°C.
General-purpose/ Environment-resistant Switches
Item
Rated
voltage
(V)
Non-inductive load
(A) Inductive load (A)
Resistive
load
Lamp
load
Inductive
load
Motor
load
NC NO NC NO NC NO NC NO
Basic
AC 125
250
500
10
10
10
3
2
1.5
1.5
1
0.8
10
10
3
5
3
1.5
2.5
1.5
0.8
DC 8
14
30
125
250
10
10
6
0.8
0.4
6
6
4
0.2
0.1
3
3
3
0.2
0.1
10
10
6
0.8
0.4
6
6
4
0.2
0.1
High-
sensitivity
High-
precision *1
AC 125
250
5
5---- ---- ----
DC 125
250
0.4
0.2 ---- ---- ----
Inrush current NC 30 A max.(15 A max. *2)
NO 20 A max.(10 A max. *2)
Minimum applicable load 5 VDC 1 mA, resistive load, P level
Model Item Max. rated voltage Leakage current (mA)
WL-LE-N Neon lamp 125 AC Approx. 0.6
250 AC Approx. 1.9
WL-LD-N
WL-LW-N LED 10 to 24 VAC/DC Approx. 0.4
115 VAC/DC Approx. 0.5
Item
Rated
voltage
(V)
Non-inductive load
(A) Inductive load (A)
Resistive
load
Lamp
load
Inductive
load
Motor
load
NC NO NC NO NC NO NC NO
Basic
AC 115 331.5 332.5
DC 12
24
115
3
3
0.8
3
3
0.2
3
3
0.8
3
3
0.2
High-
sensitivity
High-
precision *
AC 115 3 ---- ---- ----
DC 115 0.4 ---- ---- ----
Inrush current NC 3 A max.
NO 3 A max.
Minimum applicable load 5 VDC 1 mA, resistive load, P level
Degree of protection IP67
Durability
*1
Mechanical 15,000,000 operations min. *2
Electrical 750,000 operations min. *3
Operating speed
1 mm/s to 1 m/s (in case of WLCA2-N)
Operating
frequency
Mechanical 120 operations/minute min.
Electrical 30 operations/minute min.
Rated frequency 50/60 Hz
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance 25 mΩ max. (initial value for the
built-in switch when tested alone)
Dielectric
strength
Between terminals of
the same polarity
1,000 VAC (600 VAC), 50/60 Hz for
1 min
Between currentcarrying
metal part and ground
2,200 VAC (1,500 VAC), 50/60 Hz
for 1 min *4
Between each terminal
and non-currentcarrying
metal part
2,200 VAC (1,500 VAC), 50/60 Hz
for 1 min *4
Vibration
resistance Malfunction
10 to 55 Hz, 1.5-mm double amplitude
*5
Shock
resistance
Destruction 1,000 m/s2 max.
Malfunction 300 m/s2 *5
Ambient operating temperature -10 to +80°C (with no icing) *6
Ambient operating humidity 35% to 95% RH
Weight Approx. 255 g (in case of WLCA2-N)
WL-N/WLM-N
24
Ratings
Screw Terminals
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a
time constant of 7 ms max. (DC).
3.
A lamp load has an inrush current of 10 times the steady-state current.
4.
A motor load has an inrush current of 6 times the steady-state current.
* Manufacturing of the high-sensitivity, high-precision models has been
discontinued and the models have been integrated into the WL Series.
This information is provided as reference for comparison of
specifications. Refer to the model replacement table on page 45 and
order WL-series high-sensitivity or high-precision models.
* For high-sensitivity and high-precision switches.
Operation indicator Switches
Direct-wired Connector and Pre-wired Connector Switches
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a
time constant of 7 ms max. (DC).
3.
A lamp load has an inrush current of 10 times the steady-state current.
4.
A motor load has an inrush current of 6 times the steady-state current.
* Manufacturing of the high-sensitivity, high-precision models has been
discontinued and the models have been integrated into the WL Series.
This information is provided as reference for comparison of
specifications. Refer to the model replacement table on page 45 and
order WL-series high-sensitivity or high-precision models.
Characteristics
Note: 1. The above figures are initial values.
2. The figures in parentheses for dielectric strength are those
for the high-sensitivity and high-precision overtravel
models.
*1. The values are calculated at an operating temperature of +5°C to
+35°C and an operating humidity of 40% to 70% RH. Contact your
OMRON sales representative for more detailed information on
other operating environments.
*2. Durability is 10,000,000 operations min. for high-sensitivity
models.
Manufacturing of the high-sensitivity models has been
discontinued and the models have been integrated into the WL
Series. This information is provided as reference for comparison
of specifications. Refer to the model replacement table on page
45 and order WL-series high-sensitivity models.
*3. Durability is 500,000 operations min. for high-sensitivity and high-
precision models.
500,000 operations min. for weather-proof models.
Manufacturing of the high-sensitivity, high-precision models has
been discontinued and the models have been integrated into the
WL Series. This information is provided as reference for
comparison of specifications. Refer to the model replacement
table on page 45 and order WL-series high-sensitivity or high-
precision models.
Contact your OMRON representative for information on Airtight
Switches.
*4. Switches with Connectors: 1,500 V.
Spatter-prevention Switches
Item
Rated
voltage
(V)
Non-inductive load
(A) Inductive load (A)
Resistive
load
Lamp
load
Inductive
load
Motor
load
NC NO NC NO NC NO NC NO
WL
@
-LES-N
*
AC 125
250
10
10
3
2
1.5
1
10
10
5
3
2.5
1.5
WL
@
-LDS-N
*
AC 115 10 3 1.5 10 5 2.5
DC 12
24
115
10
6
0.8
6
4
0.2
3
3
0.2
10
6
0.8
6
4
0.2
Inrush current NC 30 A max.(15 A max. *)
NO 20 A max.(10 A max. *)
Minimum applicable load 5 VDC 1 mA, resistive load, P level
Model Item Max. rated voltage Leakage current (mA)
WL-LES-N Neon lamp 125 AC Approx. 0.6
250 AC Approx. 1.9
WL-LDS-N LED 10 to 24 VAC/DC Approx. 0.4
115 VAC/DC Approx. 0.5
Item
Rated
voltage
(V)
Non-inductive load
(A) Inductive load (A)
Resistive
load
Lamp
load
Inductive
load
Motor
load
NC NO NC NO NC NO NC NO
Basic
AC 115 331.5 332.5
DC 12
24
115
3
3
0.8
3
3
0.2
3
3
0.8
3
3
0.2
High-
sensitivity
High-
precision *
AC 115 3 ---- ---- ----
DC 115 0.4 ---- ---- ----
Inrush current NC 3 A max.
NO 3 A max.
Minimum applicable load 5 VDC 1 mA, resistive load, P level
Degree of protection IP67
Durability
*1
Mechanical 15,000,000 operations min. *2
Electrical 750,000 operations min. (3 A at 250
VAC, resistive load) *3
Operating speed 1 mm/s to 1 m/s
(in case of WLCA2-LDS-N)
Operating
frequency
Mechanical 120 operations/minute min.
Electrical 30 operations/minute min.
Rated frequency 50/60 Hz
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance 25 mΩ max. (initial value for the built-
in switch when tested alone)
Dielectric
strength
Between terminals of
the same polarity
1,000 VAC (600 VAC), 50/60 Hz for
1 min
Between currentcarrying
metal part and ground
2,200 VAC (1,500 VAC), 50/60 Hz
for 1 min *4
Between each terminal
and non-currentcarrying
metal part
2,200 VAC (1,500 VAC), 50/60 Hz
for 1 min *4
Vibration
resistance Malfunction 10 to 55 Hz, 1.5-mm double ampli-
tude
Shock
resistance
Destruction 1,000 m/s2 max.
Malfunction 300 m/s2
Ambient operating temperature -10 to +80°C (with no icing)
Ambient operating humidity 35% to 95% RH
Weight Approx. 255 g
(in case of WLCA2-LDS-N)
WL-N/WLM-N
25
Ratings
Screw Terminal Switches
* Manufacturing of the high-sensitivity, high-precision models has
been discontinued and the models have been integrated into the
WL Series. This information is provided as reference for
comparison of specifications. Refer to the model replacement table
on page 45 and order WL-series high-sensitivity or high-precision
models.
Operation indicator Switches
Direct-wired Connector and Pre-wired Connector Switches
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a
time constant of 7 ms max. (DC).
3. A lamp load has an inrush current of 10 times the steady-
state current.
4. A motor load has an inrush current of 6 times the steady-
state current.
* Manufacturing of the high-sensitivity, high-precision models has
been discontinued and the models have been integrated into the
WL Series. This information is provided as reference for
comparison of specifications. Refer to the model replacement table
on page 45 and order WL-series high-sensitivity or high-precision
models.
Characteristics
Note: 1. The above figures are initial values.
2. The figures in parentheses for dielectric strength are for the
High-sensitivity and High-precision Switches.
*1. The values are calculated at an operating temperature of +5°C to
+35°C, and an operating humidity of 40% to 70%RH. Contact
your OMRON sales representative for more detailed information
on other operating environments.
*2. Manufacturing of the high-sensitivity, high-precision models has
been discontinued and the models have been integrated into the
WL Series. This information is provided as reference for
comparison of specifications. Refer to the model replacement
table on page 45 and order WL-series high-sensitivity or high-
precision models.
*3. Switches with Connectors: 1,500 V.
Long-life Switches
Item
Rated
voltage
(V)
Non-inductive load
(A) Inductive load (A)
Resistive
load
Lamp
load
Inductive
load
Motor
load
NC NO NC NO NC NO NC NO
Basic
AC 115 10 3 1.5 10 5 2.5
DC 12
24
115
10
6
0.8
6
4
0.2
3
3
0.2
10
6
0.8
6
4
0.2
High-
sensitivity
High-
precision *
AC 115 5 ---- ---- ----
DC 115 0.4 ---- ---- ----
Inrush current NC 30 A max.(15 A max. *)
NO 20 A max.(10 A max. *)
Minimum applicable load 5 VDC 1 mA, resistive load, P level
Model Item Max. rated voltage Leakage current (mA)
WL-LD-N
WL-LW-N LED 10 to 24 VAC/DC Approx. 0.4
115 VAC/DC Approx. 0.5
Item
Rated
voltage
(V)
Non-inductive load
(A) Inductive load (A)
Resistive
load
Lamp
load
Inductive
load
Motor
load
NC NO NC NO NC NO NC NO
Basic
AC 115 331.5 332.5
DC 12
24
115
3
3
0.8
3
3
0.2
3
3
0.8
3
3
0.2
High-
sensitivity
High-
precision *
AC 115 3 ---- ---- ----
DC 115 0.4 ---- ---- ----
Inrush current NC 3 A max.
NO 3 A max.
Minimum applicable load 5 VDC 1 mA, resistive load, P level
Degree of protection IP67
Durability
*1
Mechanical 30,000,000 operations min.
Electrical
30,000,000 operations min.
(10 mA at 24 VDC, resistive load)
750,000 operations min.
(3 A at 115 VAC, resistive load)
High-sensitivity and High-precision
Switches: 500,000 operations min. *2
(3 A at 115 VAC, resistive load)
Operating speed 1 mm/s to 1 m/s (for WLMCA2-LD-N)
Operating
frequency
Mechanical 120 operations/minute
Electrical 30 operations/minute
Rated frequency 50/60 Hz
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance 25 mΩ max. (initial value for the
built-in switch when tested alone)
Dielectric
strength
(50/60 Hz
for 1 min)
Between terminals of
the same polarity
1,000 VAC (600 VAC), 50/60 Hz for
1 min
Between currentcarrying
metal part and ground
2,200 VAC (1,500 VAC), 50/60 Hz
for 1 min *3
Between each terminal
and non-currentcarrying
metal part
2,200 VAC (1,500 VAC), 50/60 Hz
for 1 min *3
Vibration
resistance Malfunction 10 to 55 Hz, 1.5-mm double ampli-
tude
Shock
resistance
Destruction 1,000 m/s2 max.
Malfunction 300 m/s2 max.
Ambient operating temperature –10°C to +80°C (with no icing)
Ambient operating humidity 35% to 95%RH
Weight Approx. 255 g (for WLMCA2-LD-N)
WL-N/WLM-N
26
Approved Standards
Approved Standard Ratings
UL/cUL (UL508, CSA C22.2 No.14)
* Manufacturing of the high-sensitivity, high-precision models has been discontinued and the models have been integrated into the WL Series.
This information is provided as reference for comparison of specifications. Refer to the model replacement table on page 45 and order WL-series
high-sensitivity or high-precision models.
A600 Authentication conditions
B600 Authentication conditions
C300 Authentication conditions
A300 Authentication conditions
General-purpose/ Environment-resistant/ Spatter-prevention Switches
Agency Standard File No. Approved models
UL UL508
Contact your OMRON representative for information Contact your OMRON representative for information
CSA C22.2 No.14
TÜV Rheinland EN60947-5-1
CCC (CQC) GB14048.5
Specifications Approved Standards
Indicator Sensor I/O connectors Item
No indicator
No Connector
Basic Switches A600
1 A, 125 VDC
High-sensitivity * or high-precision * B600
0.5 A, 125 VDC
Pre-wired Connector (AC) Basic, high-sensitivity *, or high-precision * C300
3 A, 250 VAC
Pre-wired Connector (DC)
Direct-wired Connector (DC)
Basic Switches 1 A, 125 VDC
High-sensitivity * or high-precision * 0.5 A, 125 VDC
Neon lamp
No Connector
Basic Switches A300
10 A, 250 VAC
High-sensitivity * or high-precision * B300
5 A, 250 VAC
Pre-wired Connector (AC) Basic, high-sensitivity *, or high-precision * C300
3 A, 250 VAC
LED
No Connector
Basic Switches
A150
10 A, 115 VAC
1 A, 115 VDC
High-sensitivity * or high-precision *
B150
5 A, 115 VAC
0.5 A, 115 VDC
Pre-wired Connector (AC) Basic, high-sensitivity *, or high-precision * C150
3 A, 115 VAC
Pre-wired Connector (DC)
Direct-wired Connector (DC)
Basic Switches 1 A, 115 VDC
High-sensitivity * or high-precision * 0.5 A, 115 VDC
Rated voltage Energizing current Current (A) Volt-ampere (VA)
Make Break Make Break
120 VAC
240 VAC
480 VAC
600 VAC
10 A
60
30
15
12
6
3
1.5
1.2
7,200 720
Rated voltage Energizing current Current (A) Volt-ampere (VA)
Make Break Make Break
120 VAC
240 VAC
480 VAC
600 VAC
5 A
30
15
7.5
6
3
1.5
0.75
0.6
3,600 360
Rated voltage Energizing current Current (A) Volt-ampere (VA)
Make Break Make Break
120 VAC
240 VAC 2.5 A 15
7.5
1.5
0.75 1,800 180
Rated voltage Energizing current Current (A) Volt-ampere (VA)
Make Break Make Break
120 VAC
240 VAC 10 A 60
30
6
37,200 720
WL-N/WLM-N
27
B300 Authentication conditions
A150 Authentication conditions
B150 Authentication conditions
C150 Authentication conditions
TÜV (EN 60947-5-1)
(Certification Only for Switches with Ground Terminals and DC Switches with Connectors)
CCC (GB14048.5)
Rated voltage Energizing current Current (A) Volt-ampere (VA)
Make Break Make Break
120 VAC
240 VAC 5 A 30
15
3
1.5 3,600 360
Rated voltage Energizing current Current (A) Volt-ampere (VA)
Make Break Make Break
120 VAC 10 A 60 6 7,200 720
Rated voltage Energizing current Current (A) Volt-ampere (VA)
Make Break Make Break
120 VAC 5 A 30 3 3,600 360
Rated voltage Energizing current Current (A) Volt-ampere (VA)
Make Break Make Break
120 VAC 2.5 A 15 1.5 1,800 180
Authentication conditions
Specification
With ground terminals With DC Connector
No indicator Neon lamp LED
Working load category AC-15 DC-12 AC-15 AC-15 DC-12 DC-12
Rated working voltage (Ue) 250 V 48 V 250 V 115 V 48 V 48 V
Rated working current (Ie) 2 A
Conditional short-circuit current 100 A
Short-circuit protective device (SCPD) 10 A, fuse type gG
Rated insulation voltage (Ui) 250 V 48 V
Rated impulse dielectric strength (Uimp) 4 kV 800 V
Pollution degree 3
Electric shock protection class Class IClass III
Authentication conditions Specification
No indicator Neon lamp LED With DC Connector With AC Connector
Working load category AC-15 DC-13 AC-15 AC-15 DC-13 DC-13 AC-15
Rated working voltage (Ue) 250 V 48 V 250 V 250 V 48 V 48 V 250 V
Rated working current (Ie) 2 A
Conditional short-circuit current 1000 A
Short-circuit protective device (SCPD) 10 A, fuse type gG
Rated insulation voltage (Ui) 250 V
WL-N/WLM-N
28
Structure and Nomenclature
Structure
*1. The available conduit screws are Pg 13.5, M20 and 1/2-14 NPT.
General-purpose Switches: WLCA2-N
Roller Lever Bolt
Set Position Marker Plate
Set the indicator needle so
that it is between protrusions
on the bearing section on the
marker plate after operation.
Cover Setscrew
A combination Philips-slotted screw is used.
A retainer prevents the screw from falling
from the cover even when the screw is loose.
Cover
Cover Seal
High sealing performance is achieved. The
seal also serves as a spacer.
There is no troublesome insulating paper,
making it easy to work with the Switch.
Head-mounting Screws
Head
You can remove the two screws to
mount the switch in any of the four
possible orientations.
Shaft Section Seal
An oil seal is fitted on the inlet of the
shaft section to maintain a tight seal.
You can change the direction of the
operational plunger to electrically switch
the direction of operation between both
sides, left only, or right only.
Operational Plunger
Built-in Switch
Built-in switch with SPST-NO+NC
contact form.
Terminal Screws
Four, M3.5 screws
Conduit Opening *1
The conduit screw is a parallel screw
for G1
/
2 piping, and is used together
with an SC connector to maintain a
tight seal.
Roller
Actuator
The roller is made of self-lubricating
sintered stainless steel and boasts high
resistance to wear.
Lever
The lever is forged from corrosion-resistant
aluminum alloy. It provides superior
corrosion resistance and outstanding
strength.
With roller lever, adjustable rod and flexible
rod models, the actuator position can be set
anywhere within 360°. (The lever cannot be
mounted in the opposite direction.)
Requires maintenance (excessive overtravel)
Requires maintenance (excessive overtravel)
Requires maintenance (insufficient overtravel)
Proper range
Proper range
Set position marker plate
Head
WL-N/WLM-N
29
Note: 1. Leakage current from indicator circuit may cause load malfunction (i.e., the load may remain ON). Make sure that the load operating
current is higher than the leakage current.
For countermeasures, refer to technical support on your OMRON website.
*1. Light-ON when operating means that the lamp lights when the Limit Switch contacts (NC) release, or when the actuator rotates or is pushed
down.
*2. Light-ON when not operating means the lamp remains lit when the actuator is free, or when the Limit Switch contacts (NO) close when the
actuator rotates or is pushed down.
Indicators
Indicator
The indicator is either a neon lamp or an
LED. Switches with LED indicators have a
built-in rectifier stack, so there is no
connection polarity.
Contact Spring
Use the terminal screws on the built-in
switch to connect to the lamp terminals.
A coil spring is used to make contact, so
connecting to the lamp terminals is not
necessary.
Indicator Covers
The indicator covered if outsert molded
from diecast aluminum and has outstanding
sealing properties.
Indicator Windows
Operating status (i.e., light-ON when
operating or light-ON when not operating)
depends on whether a neon lamp or an
LED is used.
Indicators can be switched from light-ON
when operating and light-ON when not
operating, by simply rotating the indicator
holder by 180°.
(However, Direct-wired Connector,
Pre-wired Connector, Three-core, and
Four-core Switches cannot be switched to
light-ON when operating (NC wiring).)
Light-ON when Operating/Not Operating
Lamp Holder
LED at top
LED at bottom
Light-ON when Operating Light-ON when Not Operating
Operation
WL-LE-N
WL-LD-N
WL-LW-N
Light-ON when
operating *1
Light-ON when
not operating *2
Power
Built-in switch
Internal
circuits
Load
13
Za
12
14
11
Power
Built-in switch
Internal
circuits
Load
13
12
14
11
Za
Internal Circuits
WL-LE-N
WL-LD-N
WL-LW-N
Contact spring
Neon lamp
Resistor
Contact spring Rectifier stack
Rated
current
diode
LED
Zener
diode
Resistor
Resistor
Light-ON when Not Operating
WL-N/WLM-N
30
Environment-resistant Switches
Molding Specifications for Hermetic Switches
WL@-139-N WL@-140-N WL@-141-N
WL@-145-N WL@-RP40-N WL@-RP60-N
: Molded parts
Standard
built-in switch
Airtight
built-in switch
Airtight
built-in switch
Airtight
built-in switch Airtight
built-in switch
Airtight
built-in switch
* Fluorine rubber
is used for all
rubber parts.
Oil seal
Head cap
Oil seal
Head cap
* The connector can be removed, so it is possible to use flexible conduit for the cable.
Model Cable specifications Connector type
WL@-139-N Standard 5-m VCT cable.
Finished outer diameter: 11.5 mm, 4 conductors. Resin cap
WL@-140-N
WL@-141-N
WL@-145-N Standard 5-m VCT cable, with high flexibility and good
anti-oil properties attached. Finished outer diameter:
11.5 mm, 4 conductors.
Metal connector
WL@-RP40-N Resin connector *
WL@-RP60-N Resin cap
WL-N/WLM-N
31
Spatter-prevention Switches: WLCA2-LES-N
Screws
Externally visible screws on the head and
cover are made of stainless steel to prevent
spatter adherence.
Using stainless steel prevents
spatter from adhering.
Roller Lever Bolt
Stainless steel construction to prevent
spatter adherence.
Double nut models are also available.
Head Cap
Using fluororesin prevents spatter from
adhering.
* Spatter means the zinc powder produced
when welding.
Adhering spatter to the Limit Switch may
cause malfunction of lever or lamp cover.
The lack of gap prevents spatter
powder from clogging.
Roller, Roller Axis
A baking finish is applied to the surface
so that any adhering spatter is easily
removed.
Operating Lever
Actuator
WL-N/WLM-N
32
Long-life Switches
Shield Structure
A combination Philips-slotted screw is used.
A retainer prevents the screw from falling
from the cover even when the screw is loose.
Head Cap
The head cap helps prevent the entry of cutting
chips.You can use the protrusion on the cap to
confirm the set position.
PEEK resin is used. It provides superior resistance to
wear. You can change the mounting direction to use
any one of the three operating directions (both sides,
left side, or right side).
Operating Plunger
High sealing performance is achieved. The seal also
serves as a spacer.
There is no troublesome insulating paper, making it
easy to work with the Switch.
Cover Seal
Built-in Switch
Built-in switch with an
SPST-NO+NC contact form.
Terminal Screws
Four, M3.5 screws.
Conduit Opening
In addition to parallel threads for G1/2 tubing,
direct-wired and pre-wired connectors have been
added to the series.
Cover Setscrew
Head
You can remove the two screws to mount the head in
any of the four possible directions.
A head cap and oil seal form a double-seal structure.
Excellent durability and reliability are ensured.
Actuator
The roller is made of self-lubricating sintered
stainless steel.
It provides superior resistance to wear.
Lever
Roller
The lever is forged from anti-corrosive aluminum
alloy. It provides superior corrosion resistance and
outstanding strength. With a roller lever actuator,
the actuator position can be set anywhere within
360°. (The lever cannot be mounted in the opposite
direction.)
Cover
Oil seal
Head cap
WL-N/WLM-N
33
Dimensions and Operating Characteristics (Unit: mm)
Switches with Roller Lever Actuators
Basic, High-sensitivity*1, and High-precision Switches*1
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
*1. Manufacturing of the high-sensitivity, high-precision models has been discontinued and the models have been integrated into the WL Series.
This information is provided as reference for comparison of specifications. Refer to the model replacement table on page 45 and order WL-
series high-sensitivity or high-precision models.
*2. The operating characteristics for WLCA12-N, WLCA12-2-N, WLCA12-2N-N, and WLG12-N are measured at the lever length of 38 mm.
General-purpose Switches
Model
Operating characteristics WLCA2-N WLCA2-2-N WLCA2-2N-N WLG2-N WLCA2-7-N WLCA2-8-N
*1 (WLGCA2-N )
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
min.
max.
13.34 N
1.18 N
15±5°
70°
12°
13.34 N
1.18 N
25±5°
60°
16°
13.34 N
1.18 N
20° max.
70°
10°
13.34 N
1.18 N
10°
80°
7°
10.2 N
0.9 N
15±5°
70°
12°
8.04 N
0.71 N
15±5°
70°
12°
13.34 N
1.18 N
5°
85°
3°
Model
Operating characteristics WLCA12-N *2 WLCA12-2-N
*2 WLG12-2N-N *2 *1 (WLG12-N)
*2
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
min.
max.
13.34 N
1.18 N
15±5°
70°
12°
13.34 N
1.18 N
25±5°
60°
16°
13.34 N
1.18 N
20° max.
70°
10°
13.34 N
1.18 N
10°
80°
7°
Standard Switches
M5
Allen-head bolt
JIS B 0202 G½
17.5×7 dia. *
(125)
(4.9) (15.1)
40±0.7
30.2±0.2
58.7±0.2
14.7
R38
Four, 5.2 dia. holes
Two, M3.5
Three, M4
* Stainless sintered roller
5
60 max.
12.7
40±1.5
41.5±1.5
53±1.5
68.7
21.6
53.2±0.8
42 max.
29.2±1.2
Four, M6
Depth: 15 min.
25.4
25.4
13.1
Roller lever R38
Basic
WLCA2-N
WLCA2-2-N
WLCA2-2N-N
The only difference in the shape for High-sensitivity and
High-precision Switches is the set position marker plate. *1
High-sensitivity*1
(WLG2-N)
High-precision*1
(WLGCA2-N)
17.5×15 dia. *
(137)
(4.9) (15.1)
40±0.7
30.2±0.2
58.7±0.2
14.7
R50 Two, M3.5
Three, M4
Four, 5.2 dia.
holes
* Stainless sintered roller
5
67.2 max.
12.7
41.5±1.5
58.1±1.5
M5
Allen-head bolt
JIS B 0202 G½
68.7
21.6
53.2±0.8
42 max.
29.2±1.2
Four, M6
Depth: 15 min
25.4
25.4
13.1
36±1.5
Roller lever R50
Basic
WLCA2-7-N
M5
Allen-head bolt
17.5×7 dia. *
(150)
(4.9) (15.1)
40±0.7
30.2±0.2
58.7±0.2
14.7
R63 Two, M3.5
Three, M4
JIS B 0202 G½
Four, 5.2 dia.
holes
* Stainless sintered roller
5
60 max.
12.7
41.5±1.5
40±1.5
53±1.5
68.7
21.6
53.2±0.8
42 max.
29.2±1.2 Four, M6
Depth: 15 min
25.4
25.4
13.1
Roller lever R63
Basic
WLCA2-8-N
17.5×7 dia. *
(4.9) (15.1)
40±0.7
30.2±0.2
58.7±0.2
14.7
Two, M3.5
Three, M4
M5
Allen-head
bolt
JIS B 0202 G½
Four, 5.2 dia. holes
* Stainless sintered roller
5
Adjustable range:
25 to 89
67 max.
12.7
41.5±1.5
60±1.5
68.7
65.2±0.8
42 max.
21.6
29.2±1.2
Four, M6
Depth: 15 min
25.4
25.4
13.1
Adjustable roller lever
Basic
WLCA12-N
WLCA12-2-N
WLCA12-2N-N
High-sensitivity*1
(WLG12-N)
Only the external appearance of the set position
indicator plate varies on high-sensitivity models. *1
+2°
1°
+2°
0°
+2°
1°
WL-N/WLM-N
34
Switches with Roller Lever Actuators
Basic, High-sensitivity*1, and Protective Switches
Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Note: The actuator on the WLCAL4-N and WLCAL5-N is heavy, which may result in resetting problems depending on the direction the Switch is
mounted. Mount the Switch so that the actuator is facing downwards to prevent this problem from occurring.
*1. Manufacturing of the high-sensitivity, high-precision models has been discontinued and the models have been integrated into the WL Series.
This information is provided as reference for comparison of specifications. Refer to the model replacement table on page 45 and order WL-
series high-sensitivity or high-precision models.
*2. The operating characteristics for WLCL-N, WLCL-2-N, WLCL-2N-N, and WLGL-N are measured at the lever length of 140 mm.
*3. The operating characteristics of WLCAL4-N are measured at a rod length of 380 mm.
Model
Operating characteristics WLCL-N *2 WLCL-2-N *2 WLCL-2N-N *2 *1 (WLGL-N) *2 WLCAL4-N *3 WLCAL5-N
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
min.
max.
1.39 N
0.27 N
15±5°
70°
12°
1.39 N
0.27 N
25±5°
60°
16°
1.39 N
0.27 N
20° max.
70°
10°
2.84 N
0.25 N
10°
80°
7°
0.98 N
0.15 N
15±5°
70°
12°
0.9 N
0.09 N
15±5°
70°
12°
Model
Operating characteristics WLCA32-41 to 44-N
Force necessary to reverse the direction of the lever
Movement until the lever reverses
Movement until switch operation
Movement after switch operation
max.
max.
min.
11.77 N
50±5°
55°
35°
9
(4.9) (15.1)
40
±0.7
30.2
±0.2
Three, M4
Two, M3.5
M8
Allen-head
set screw
M5
Allen-head
set screw
JIS B 0202 G½
Four, 5.2 dia.
holes
3
±0.2
dia.
(length:160) *
58.7
±0.2
5
Adjustable range:
25 to 140
14.7
* Stainless steel rod
55 max.
41.5
±1.5
46
±1.5
68.7
42 max.
21.6
29.2
±1.2
Four, M6
Depth: 15 min.
25.4
25.4
12.7
13.1
Adjustable rod lever 25 to 140 mm
Basic
WLCL-N
WLCL-2-N
WLCL-2N-N
High-sensitivity *1
(WLGL-N)
Only the external appearance of the set position
indicator plate varies on high-sensitivity models. *1
8
(4.9) (15.1)
40
±0.7
30.2
±0.2
Three, M4
Four, 5.2 dia.
holes
5
12.8
65
* Stainless steel rod
3.2 dia. *
14.7
58.7
±0.2
41.5
±1.5
JIS B 0202 G½
M5
Allen-head
set screw
68.7
42 max.
21.6
29.2
±1.2
25.4
25.4
54.5
±1.5
67 max.
13.1
12.7
Four, M6
Depth: 15 min.
Adjustable range:
350 to 380
Adjustable rod lever
Basic
WLCAL4-N
67 max.
(4.9) (15.1)
40±0.7
30.2±0.2
Three, M4
5
* Piano wire
65
11
2.3 dia. *
14.7
58.7±0.2
428.5±2
Four, 5.2
dia. holes
41.5±1.5
Four, M6
Depth: 15 min.
JIS B 0202 G½
M5
Allen-head
bolt 68.7
21.6
29.2±1.2
25.4
25.4
54.5±1.5
12.7
13.1
42 max.
7.5
Rod spring lever
Basic
WLCAL5-N
13.1
12.7
21.6
62.5 max.
56.4±3.5
42.8±3.5
Two, M3.5
Three, M4
Four, 5.2 dia.
holes
Two, 17.5×7 dia. *
30.2±0.2
40±0.7
(4.9)
5
58.7±0.2
(15.1)
(125)
14.7
Four, M6
Depth: 15 min.
JIS B 0202 G½ 4-M6
M5 Allen-head
set screw
29.2±1.2
42 max.
68.7
34.1
25.4
* Plastic Roller
(The WLCA32-041-N to WLCA32-044-N have stainless steel rollers.)
90°±3°
R38
Fork lever lock
Protective Switches
WLCA32-41-N
WLCA32-42-N
WLCA32-43-N
WLCA32-44-N
The WLCA32-41-N is shown in the following
diagram.
+2°
1°
WL-N/WLM-N
35
Switches with Plunger Actuators
Basic Switches
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Model
Operating characteristics WLD18-N WLD28-N WLD38-N WLD2-N WLSD-N WLSD2-N WLSD3-N
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
max.
min.
max.
26.67 N
8.92 N
1.7 mm
6.4 mm
1 mm
16.67 N
4.41 N
1.7 mm
5.6 mm
1 mm
16.67 N
4.41 N
1.7 mm
5.6 mm
1 mm
26.67 N
8.92 N
1.7 mm
5.6 mm
1 mm
40.03 N
8.89 N
2.8 mm
6.4 mm
1 mm
40.03 N
8.89 N
2.8 mm
5.6 mm
1 mm
40.03 N
8.89 N
2.8 mm
4 mm
1 mm
Operating position
Total travel position
OP
TTP max.
34±0.8 mm
29.5 mm
44±0.8 mm
39.5 mm
44.5±0.8 mm
41 mm
44±0.8 mm
39.5 mm
40.6±0.8 mm
54.2±0.8 mm
54.1±0.8 mm
PT
13.1
12.9
21.6
* Stainless steel plunger
Three, M4
Four, 5.2 dia. holes
R1 *
Two, M3.5
30.2
±0.2
40±0.7
(4.9)
5
58.7±0.2
(15.1)
10 dia.
OP
JIS B 0202 G
½Four, M6
Depth: 15 min
29.2
±1.2
42 max.
68.7
Sealed Top Plunger
WLD18-N
Three, M4
Four, 5.2 dia. holes
30.2
±0.2
40±0.7
(4.9)
5
58.7±0.2
(15.1)
13.1
12.7
21.6
JIS B 0202 G
½Four, M6
Depth: 15 min
29.2
±1.2
42 max.
68.7
27.5
46.6±0.8
OP
PT
*1. Stainless steel plunger
*2. Cosmetic nuts
25 dia. *2
Two, M3.5
17.8
(96.2)
25.4
R1
9.3 dia. *1
Horizontal Plunger
WLSD-N
PT
Three, M4
Four, 5.2 dia. holes
Two, M3.5
30.2
±0.2
40±0.7
(4.9)
5
58.7±0.2
(15.1)
OP
13.1
12.9
21.6
JIS B 0202 G
½Four, M6
Depth: 15 min
29.2
±1.2
42 max.
68.7
*Stainless sintered roller
14.3
dia.
×5
*
Sealed Top-roller Plunger
WLD28-N
Three, M4
Four, 5.2 dia. holes
30.2
±0.2
40±0.7
(4.9)
5
58.7±0.2
(15.1)
13.1
12.7
21.6
JIS B 0202 G
½Four, M6
Depth: 15 min
29.2
±1.2
42 max.
68.7
55.7±0.8
*1. Stainless sintered roller
*2. Cosmetic nuts
25 dia. *2
Two, M3.5
17.8
(96.2)
25.4
PT OP
17 dia.×4.6 *1
27.5
Horizontal-roller Plunger
WLSD2-N
PT
Three, M4
Four, 5.2 dia. holes
Two, M3.5
30.2
±0.2
40±0.7
(4.9)
5
58.7±0.2
(15.1)
OP
13.1
12.9
21.6
JIS B0202 G
½Four, M6
Depth: 15 min
29.2
±1.2
42 max.
68.7
* Stainless steel ball
1/2"
dia. *
15.5 dia.
Sealed Top-ball Plunger
WLD38-N
Three, M4
Four, 5.2 dia. holes
30.2
±0.2
40
±0.7
(4.9)
5
58.7
±0.2
(15.1)
13.1
12.7
21.6
JIS B0202 G
½Four, M6
Depth: 15 min
29.2
±1.2
42 max.
68.7
46.6
±0.8
*
1. Stainless steel ball
*
2. Cosmetic nuts
25 dia.
*
2
Two, M3.5
17.8
(96.2)
25.4
PT OP
15.5 dia.
1/2" dia.
*
1
27.5
Horizontal-ball Plunger
WLSD3-N
PT
30.2
±0.2
40
±0.7
(4.9)
5
58.7
±0.2
(15.1)
OP
13.1
12.9
21.6
29.2
±1.2
68.7
28.4
Four, M6
Depth: 15 min
Three, M4
Four, 5.2 dia. holes
Four, M3.5
JIS B0202 G
½
42 max.
*
Stainless sintered roller
17
dia.
×4.6
*
Top-roller Plunger
WLD2-N
WL-N/WLM-N
36
Switches with Flexible Rod Actuators
Basic Switches
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
* These values are for the top end of the spring, rod, or wire.
Model
Operating characteristics WLNJ-N WLNJ-30-N WLNJ-2-N WLNJ-S2-N
Operating force
Pretravel
OF
PT
Max. 1.47 N
20±10 mm
1.47 N
20±10 mm
1.47 N
40±20 mm
0.28 N
40±20 mm
Three, M4
Four, 5.2 dia. holes
30.2
±0.2
40±0.7
(4.9)
5
58.7±0.2
(15.1)
13.1
12.9
21.6
JIS B 0202 G
½Four, M6
Depth: 15 min
29.2
±1.2
42 max.
68.7
Two, M3.5
* 3
PT
* 1
* 2
(107)
33.7±0.8
140±2.5
6.5 dia.
*1. Do not operate the Switch in the direction of the axial center.
*2. Stainless steel coil spring.
*3. The range for operation is 1/3rd of the overall spring length from the end of the spring.
Coil Spring
WLNJ-N
Three, M4
Four, 5.2 dia. holes
30.2
±0.2
40±0.7
(4.9)
5
58.7±0.2
(15.1)
13.1
12.9
21.6
JIS B 0202 G
½Four, M6
Depth: 15 min
29.2
±1.2
42 max.
68.7
Two, M3.5
* 3
PT
* 1
* 2
(107)
33.7
±0.8
140±2.5
4.8 dia.
*1. Do not operate the Switch in the direction of the axial center.
*2. Piano wire coil spring.
*3. The range for operation is 1/3rd of the overall spring length from the end of the spring.
Coil Spring (Multi-wire)
WLNJ-30-N
26 dia.
Three, M4
Four, 5.2 dia. holes
30.2
±0.2
40±0.7
(4.9)
5
58.7±0.2
(15.1)
13.1
12.9
21.6
JIS B0202 G
½Four, M6
Depth: 15 min
29.2
±1.2
42 max.
68.7
Two, M3.5
* 3
PT
* 1
* 2
(95.4)
44.6
±0.8
140±2.5
8 dia.
*1. Do not operate the Switch in the direction of the axial center.
*2. Polyamide Resin Rod
*3. The range for operation is 1/3rd of the overall rod length from the end of the rod.
Resin Rod
WLNJ-2-N
Three, M4
Four, 5.2 dia. holes
30.2
±0.2
40±0.7
(4.9)
5
58.7±0.2
(15.1)
13.1
12.9
21.6
JIS B 0202 G
½Four, M6
Depth: 15 min
29.2
±1.2
42 max.
68.7
Two, M3.5
* 3
PT
* 1
* 2
(159)
33.7
±0.8
193±2.5
1 dia
*1. Do not operate the Switch in the direction of the axial center.
*2. Stainless steel wire.
*3. The range for operation is 1/3rd of the overall wire length from the end of the wire.
Steel Wire
WLNJ-S2-N
WL-N/WLM-N
37
(For details about applicable cables, refer to Connecting Sensor I/O Connectors Cable and Socket on page 16.)
Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
2. The following diagrams are for a indicator-equipped models.
* Manufacturing of the high-sensitivity, high-precision models has been discontinued and the models have been integrated into the WL Series.
This information is provided as reference for comparison of specifications. Refer to the model replacement table on page 45 and order WL-series
high-sensitivity or high-precision models.
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Switches with Roller Lever Actuators
Model
Operating characteristics Basic Switches High-sensitivity
Switches*
High-precision
Switches*
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
min.
max.
13.34 N
1.18 N
15±5°
70°
12°
13.34 N
1.18 N
10°
80°
7°
13.34 N
1.18 N
5°
85°
3°
Sensor I/O connector Switches
40±0.7
30.2±0.2
R38
* Stainless sintered roller
17.5×7 dia. *
(125)
12.5
(4.9) (15.1)
58.7±0.2
14.7
Two, M3.5
M5
Allen-head
bolt
M12×1
Three, M4
Four, 5.2 dia. holes
5
68.7
53.2±0.8
42 max.
29.2±1.2 Four, M6
Depth: 15 min.
25.4
60 max.
12.7
40±1.5
41.5±1.5
53±1.5
25.4
13.1
Switches with Direct-wired Connectors
Basic Switches
WLCA2-LDK13-N
High-sensitivity Switches *
(WLG2-LDK13-N)
High-precision Switches *
(WLGCA2-LDK13-N)
The only difference in the shape for High-sensitivity and
High-precision Switches is the set position marker plate.*
40±0.7
30.2±0.2
* Stainless sintered roller
17.5×7 dia. *
SC-1M
(125)
(4.9)
(15.1)
58.7±0.2
14.7
Two, M3.5
M5
Allen-head bolt
Three, M4
300
Four, 5.2 dia. holes
5
XS2H-D421
R38
53.2±0.8
+100
50
42 max.
29.2±1.2
68.7
25.4
60 max.
41.5±1.5
40±1.5
53±1.5
25.4
12.7
13.1
Four, M6
Depth: 15 min
Switches with Pre-wired Connectors
Basic Switches
WLCA2-LD-M1J-N
High-sensitivity Switches *
(WLG2-LD-M1J-N)
High-precision Switches *
(WLGCA2-LD-M1J-N)
The only difference in the shape for High-sensitivity and
High-precision Switches is the set position marker plate.*
+2°
1°
+2°
0°
Operation indicator Switches
40±0.7
30.2±0.2
* Stainless sintered roller
R38
17.5×7 dia. *
(125)
(4.9) (15.1)
58.7±0.2
14.7
Two, M3.5
M5
Allen-head bolt
Three, M4
Four, 5.2 dia. holes
5
JIS B 0202 G½
53.2±0.8
42 max.
29.2±1.5
21.6
68.7
25.4
60 max.
53±1.5
41.5±1.5
40±1.5
25.4
13.1
12.7
Four, M6
Depth: 15 min
Roller lever
WLCA2-LD-N
WLCA2-LE-N
Model
Operating characteristics
WLCA2-LD-N
WLCA2-LE-N
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
min.
max.
13.34 N
1.18 N
15±5°
70°
12°
WL-N/WLM-N
38
Switches with Roller Lever Actuators
Switches with Sealed Top-roller Plungers
Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
2. The above diagrams are for Indicator-equipped Switches.
* Manufacturing of the high-sensitivity, high-precision models has been discontinued and the models have been integrated into the WL Series.
This information is provided as reference for comparison of specifications. Refer to the model replacement table on page 45 and order WL-series
high-sensitivity or high-precision models.
Spatter-prevention Switches
Actuator Switches with Roller Lever Actuators Switches with Sealed Top-
roller Plungers
Operating characteristics Basic Switches High-sensitivity
Switches *
High-precision
Switches *
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
min.
max.
13.34 N
1.18 N
15±5°
70°
12°
13.34 N
1.18 N
10°
80°
7°
13.34 N
1.18 N
5°
85°
3°
16.67 N
4.41 N
Max.1.7 mm
5.6 mm
1 mm
Operating position
Total travel position
OT
TTP max.
44±0.8 mm
39.5 mm
17.5×7 dia. *
(125)
(4.9) (15.1)
40±0.7
30.2±0.2
R38
Two, M3.5
M5
Allen-head bolt
Fluorine
resin cap
Three, M4
JIS B 0202 G½
Four, 5.2 dia. holes
* Stainless sintered roller
58.7±0.2
14.7
5
68.7
21.6
53.2±0.8
42 max.
29.2±1.2 Four, M6
Depth: 15 min
25.4
60 max.
12.7
40±1.5
41.5±1.5
53±1.5
25.4
13.1
Switches with Screw Terminals
Basic Switches
WLCA2-@S-N
High-sensitivity Switches *
(WLG2-@S-N)
High-precision Switches *
(WLGCA2-@S-N)
Four, M6
Depth: 15 min
40±0.7
30.2±0.2
* Stainless sintered roller
17.5×7 dia. *
SC-1M
(125)
(4.9)
(15.1)
58.7±0.2
14.7
Two, M3.5
M5
Allen-head bolt
Three, M4
Four, 5.2 dia. holes
5
XS2H-D421
R38
53.2±0.8
42 max.
68.7
25.4
60 max.
41.5±1.5
40±1.5
300
53±1.5
25.4
13.1
12.7
+100
50
29.2±1.2
Fluorine
resin cap
Switches with Pre-wired Connectors
WLCA2-@S-M1J-1-N
PT
*Stainless sintered roller
14.3 dia.×5 *
Two, M3.5
OP
42 max.
13.1
12.9
21.6
Depth: 15 min
JIS B 0202 G
½Four, M6
29.2±1.2
68.7
Rubber cap
(fluorine rubber)
Three, M4
Four, 5.2 dia. holes
30.2±0.2
40±0.7
(4.9)
5
58.7±0.2
(15.1)
Switches with Screw Terminals
WLD28-@S-N
*Stainless sintered roller
42 max.
13.1
12.9
Depth: 15 min
Four, M6
29.2±1.2
68.7
Rubber cap
(fluorine rubber)
30.2±0.2
40±0.7
(4.9)
5
58.7±0.2
(15.1)
Three, M4
XS2H-D421
14.3 dia.×5 *
Two, M3.5
Four, 5.2 dia. holes
SC-1M
−50
+100
300
PT
OP
Switches with Pre-wired Connectors
WLD28-@S-M1J-1-N
+2°
1°
+2°
0°
WL-N/WLM-N
39
Switches with Roller Lever Actuators
Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
2. The above diagrams are for Indicator-equipped Switches.
* Manufacturing of the high-sensitivity, high-precision models has been discontinued and the models have been integrated into the WL Series.
This information is provided as reference for comparison of specifications. Refer to the model replacement table on page 45 and order WL-series
high-sensitivity or high-precision models.
Long-life Switches
Actuator Switches with Roller Lever Actuators
Operating characteristics Basic Switches High-sensitivity
Switches *
High-precision
Switches *
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
min.
max.
13.34 N
1.18 N
15±5°
70°
12°
13.34 N
1.18 N
10°
80°
7°
13.34 N
1.18 N
5°
85°
3°
42 max.
13.1
12.7
Depth: 15 min
JIS B 0202 G
½
Four, M6
29.2±1.2
68.7
30.2±0.2
40±0.7
(4.9)
5
58.7±0.2
(15.1)
14.7
60 max.
53±1.5
41.5±1.5
53.2±0.8
*Stainless sintered roller
Two, M3.5
Three, M4
Four, 5.2 dia. holes
17.5 dia.×7 *
M5 Allen-head bolt
Fluorine resin cap
25.4
25.4
40±1.5
R38
21.6
Switches with Screw Terminals
Basic Switches
WLMCA2-LD-N
High-sensitivity Switches *
(WLMG2-LD-N)
High-precision Switches *
(WLMGCA2-LD-N)
42 max.
13.1
12.7
Depth: 15 min
Four, M6
29.2±1.2
68.7
30.2±0.2
40±0.7
(4.9)
5
58.7±0.2
(15.1)
14.7
60 max.
53±1.5
41.5±1.5
53.2±0.8
*Stainless sintered roller
Two, M3.5
Three, M4
M12×1
Four, 5.2 dia. holes
17.5 dia.×7 *
M5 Allen-head bolt
Fluorine resin cap
25.4
25.4
40±1.5
R38
12.5
Switches with Direct-wired Connectors
Basic Switches
WLMCA2-LDK13-N
High-sensitivity Switches *
(WLMG2-LDK13-N)
High-precision Switches *
(WLMGCA2-LDK13-N)
42 max.
13.1
12.7
Depth: 15 min
Four, M6
29.2±1.2
68.7
30.2±0.2
40±0.7
(4.9)
5
58.7±0.2
(15.1)
14.7
60 max.
53±1.5
41.5±1.5
53.2±0.8
*Stainless sintered roller
Two, M3.5
17.5 dia.×7 *
M5 Allen-head bolt
Fluorine resin cap
25.4
25.4
40±1.5
R38
SC-1M
XS2H-D421
Three, M4
Four, 5.2 dia. holes
−50
+100
300
Switches with Pre-wired Connectors
Basic Switches
WLMCA2-LD-M1J-N
High-sensitivity Switches *
(WLMG2-LD-M1J-N)
High-precision Switches *
(WLMGCA2-LD-M1J-N)
+2°
1°
+2°
0°
WL-N/WLM-N
40
Actuators (Levers Only)
Lever: Only rotating lever models are illustrated.
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
11.4
17.5 dia. × 7,
sintered stainless steel roller
7.3-dia.
mounting
holes 38
16 M5
Allen-head bolt
54.8
17.9
12.6
WL-1A100
Standard Lever
11.4
17.5 dia. (length: 7)
resin roller
7.3-dia.
mounting
holes 38
16 M5
Allen-head bolt
54.8
17.9
12.6
WL-1A115
Resin Roller
11.4
17 dia. (length: 6)
bearing roller
7.3-dia.
mounting
holes 38
16 M5
Allen-head bolt
54.8
16.9
12.1
WL-1A400
Bearing Roller
11.4
17.5 dia. (length: 30)
Nylon roller
7.3-dia.
mounting
holes
16 M5
Allen-head bolt
54.8
40.2±0.8
23.6
38
WL-1A118
Nylon Roller:
Roller Width: 30 mm
11.4
17.5 dia. × 7,
sintered stainless steel roller
7.3-dia.
mounting
holes 38
16 T
wo, M5
Allenhead nut
and arm set screw
54.8
17.9
12.6
WL-1A105
Double Nuts
11.4
17.5 dia. (length: 7)
stainless steel roller
7.3-dia.
mounting
holes 38
16 M5
Allen-head bolt
54.8
17.9
12.6
WL-1A103S
Spatter Prevention
17.5 dia. × 15,
sintered stainless steel roller
7.3-dia.
mounting
holes
50
16 M5
Allen-head bolt
66.8
11.4
25.7
16.6
WL-1A200
Lever Length: 50
Roller Width: 15
7.3-dia.
mounting
holes
63
16 M5
Allen-head bolt
79.8
17.5 dia. × 7,
sintered stainless steel roller
11.4
17.9
12.6
WL-1A300
Lever Length: 63
16
12
17.5 dia. × 7,
sintered stainless steel roller
Adjustable lever:
stainless steel
7.3-dia.
mounting
holes
M5
Allen-head
bolt
Adjustable
range:
25 to 89
24.9
±0.8
19.7
±0.8
105.75
23
WL-2A100
16
12
17.5 dia. (length: 7)
resin roller
Adjustable lever:
stainless steel
7.3-dia.
mounting
holes M5
Allen-head
bolt
Adjustable
range:
25 to 89
24.9±0.8
19.7±0.8
105.75
23
WL-2A111
Resin Roller
16
12
17.5 dia. × 7,
sintered stainless
steel roller
Adjustable lever:
stainless steel
7.3-dia.
mounting
holes
Adjustable
range:
25 to 89
24.9
±0.8
19.7
±0.8
105.75
M5
Allen-head
bolt
Two, M5 Allen-head nut
and arm set screw
23
WL-2A107
Double Nuts
(15.8)
6.2
17.5 dia. (length: 7)
resin roller
Adjustable lever:
stainless steel
7.3-dia.
mounting
holes
M5
Allen-head
bolt
Adjustable
range:
25 to 140
24.9±0.8
19.7
±
0.8
155.75
23
WL-2A108
Resin Roller
(15.8)
6.2
17.5 dia. × 7,
sintered stainless
steel roller
Adjustable lever:
stainless steel
7.3-dia.
mounting
holes
M5
Allen-head
bolt
Adjustable
range:
25 to 140
24.9±0.8
19.7
±
0.8
155.75
23
WL-2A122
16
20
17.5 dia. × 7,
sintered stainless
steel roller
Adjustable lever:
stainless steel
7.3-dia.
mounting
holes M5
Allen-head
bolt
Adjustable
range:
25 to 89
24.9±0.8
19.7±0.8
105.75
23
9.1
* Can be installed
on the rear side.
WL-2A106
24.7
±0.8
19.5
±0.8
(112)
3
M5
Allen-head bolt
(10)
(21.8)
(10)
17.5 dia. × 7,
sintered stainless
steel roller
R89.5
20
15.9
23
Three, 5.3
dia. holes
7.3 dia.
mounting holes
+0.2
0
WL-2A130
16
23
12
50 dia. (length: 6)
Nylon roller
7.3-dia.
mounting
holes
M5
Allen-head
bolt
Adjustable
from 42 to 89
24.9
±0.8
19.7
±0.8
WL-2A104
WL-N/WLM-N
41
Lever: Only rotating lever models are illustrated.
Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
2. When using the adjustable roller (rod) lever, make sure that the lever is facing downwards.
Use caution, as telegraphing (the Switch turns ON and OFF repeatedly due to inertia) may occur.
16
50 dia. (length: 15)
Nylon roller
7.3-dia.
mounting
holes
M5
Allen-head
bolt
Adjustable
from 41 to
78.5
34.5
24.4
122 23
WL-2A110
16
49 dia. rubber roller
Material: NBR
7.3-dia.
mounting
holes
M5
Allen-head
bolt
Adjustable
from 41 to
89
34.2
24.2
6
23
WL-2A105
11.5
50 dia. (length: 6)
Nylon roller
7.3-dia.
mounting
holes
16
M5
Allen-head
bolt
20.1±0.8
R38
WL-1A106
11.5
35 dia. (length: 6)
Nylon roller
7.3 dia.
mounting
holes
M5
Allen-head
bolt 16
20.1
±0.8
R38
WL-1A110
3-dia. stainless
steel rod
7.3-dia. mounting
holes
M5
Allen-head
bolt
Adjustable
from
25 to 140
160
9
19
11
M8
Allen-head
set screw
WL-4A100
2-dia. stainless
steel for spring
7.3-dia.
mounting holes
M5
Allen-head
bolt
Adjustable
from 270 to
290
9
13
11
M8
Allen-head
set screw
WL-4A201
Actuator's
center of
rotation
7.3-dia.
mounting
holes
400±2
12.8
8
7.5
11
6
M5
Allen-head
bolt
65±2
3.2-dia.
stainless
steel rod
Adjustable
from 350
to 380
25.5 max.
13.4
WL-3A100
7.3-dia.
mounting
holes
400
±2
12.8
8
7.5
11
6
Two, M5
Allenhead
nut and arm
set screw
65
±2
3.2-dia.
stainless steel rod
Adjustable
from 350
to 380
25.5 max.
13.4
M5
Allen-head
bolt
WL-3A106
Double Nut
7.3-dia.
mounting
holes
680
±0.4
12.8
8
7.5
11
6
M5
Allen-head
bolt
65
±2
3.2-dia.
stainless steel rod
Adjustable
from 650
to 660
25.5 max.
13.4
WL-3A108
7.3-dia.
mounting
holes
450±4
417.5±2
7.5
7.5
12.5 dia. max.
11
6
M5
Allen-head
bolt
2.3-dia.
operation rod
24.6 max.
13
(95)
WL-3A200
7.3-dia.
mounting
holes
470±4
437.5±2
8 dia.
7.5
12.5
dia.
max.
11
6
M5
Allen-head
bolt
2.3 dia.
rod
7.5
24.6 max.
13
(95)
50
Cap
Adhesive
WL-3A203
4-dia. stainless
steel rod
7.3-dia.
mounting holes
M5
Allen-head
bolt
Adjustable
up to 141
160
±1.5
9
19
11
M8
Allen-head
set screw
WL-4A112
15.8
(108)
3
M5
Allen-head
bolt
10
(18.5)
10
11.3
20
15.9
22.1
7.3 dia.
mounting
hole
84
95.3
Three, 5.2
dia. holes
Marking R8
WL-2A129
WL-5A100 has a plastic roller
Two, 17.5 dia. × 7,
sintered stainless steel rollers
M5 Allen-head
bolt 11
1.3
6.7 17.7
54.8
90°
R38
7.3 dia.
12.4
WL-5A101
WL-5A102 has a plastic roller
Two, 17.5 dia. × 7,
sintered stainless steel rollers
M5 Allen-head
bolt 11
1.3
17.7
54.8
90°
R38
6.7
12.4
7.3 dia.
WL-5A103
WL-5A104 has a plastic roller
Two, 17.5 dia. × 7,
sintered stainless steel rollers
M5 Allen-head
bolt 11
17.7
12.4
54.8
90°
R38
7.3 dia.
WL-5A105
WL-N/WLM-N
42
Model Replacement Table (Replacing WL Basic Models with WL-N Basic Models)
Manufacturing of the basic WL models is scheduled to be discontinued. Use the following table to find the corresponding WL-N-series models and
order them instead.
WL WL-N
WLCA2 WLCA2-N
WL01CA2 WLCA2-N
WLH2 WLCA2-N
WL01H2 WLCA2-N
WLCA2-2 WLCA2-2-N
WL01CA2-2 WLCA2-2-N
WLCA2-2N WLCA2-2N-N
WL01CA2-2N WLCA2-2N-N
WLCA2-7 WLCA2-7-N
WL01CA2-7 WLCA2-7-N
WLCA2-8 WLCA2-8-N
WL01CA2-8 WLCA2-8-N
WLCA12 WLCA12-N
WL01CA12 WLCA12-N
WLH12 WLCA12-N
WL01H12 WLCA12-N
WLCA12-2 WLCA12-2-N
WL01CA12-2 WLCA12-2-N
WLCA12-2N WLCA12-2N-N
WL01CA12-2N WLCA12-2N-N
WLCL WLCL-N
WL01CL WLCL-N
WLHL WLCL-2N-N
WL01HL WLCL-2N-N
WLCL-2 WLCL-2-N
WLCL-2N WLCL-2N-N
WL01CL-2N WLCL-2N-N
WLHAL4 WLCAL4-N
WLHAL5 WLCAL5-N
WLCA32-41 WLCA32-41-N
WL01CA32-41 WLCA32-41-N
WLCA32-42 WLCA32-42-N
WLCA32-43 WLCA32-43-N
WL01CA32-43 WLCA32-43-N
WLCA32-44 WLCA32-44-N
WL01CA32-44 WLCA32-44-N
WLD WLD18-N
WL01D WLD18-N
WLD2 WLD28-N
WL01D2 WLD28-N
WLD3 WLD38-N
WL01D3 WLD38-N
WLD28 WLD28-N
WL01D28 WLD28-N
WLSD WLSD-N
WL01SD WLSD-N
WLSD2 WLSD2-N
WL01SD2 WLSD2-N
WLSD3 WLSD3-N
WL01SD3 WLSD3-N
WLNJ WLNJ-N
WL01NJ WLNJ-N
WLNJ-30 WLNJ-30-N
WL01NJ-30 WLNJ-30-N
WLNJ-2 WLNJ-2-N
WL01NJ-2 WLNJ-2-N
WLNJ-S2 WLNJ-S2-N
WL01NJ-S2 WLNJ-S2-N
WLCA2-LE WLCA2-LE-N
WLCA2-LD WLCA2-LD-N
WLH2-LE WLCA2-LE-N
WLH2-LD WLCA2-LD-N
WLCA2-2LE WLCA2-2LE-N
WLCA2-2LD WLCA2-2LD-N
WLCA2-2NLE WLCA2-2NLE-N
WLCA2-2NLD WLCA2-2NLD-N
WLCA2-7LE WLCA2-7LE-N
WLCA2-7LD WLCA2-7LD-N
WLCA2-8LE WLCA2-8LE-N
WLCA2-8LD WLCA2-8LD-N
WLCA12-LE WLCA12-LE-N
WLCA12-LD WLCA12-LD-N
WLH12-LE WLCA12-LE-N
WLH12-LD WLCA12-LD-N
WLCA12-2LE WLCA12-2LE-N
WLCA12-2LD WLCA12-2LD-N
WLCA12-2NLE WLCA12-2NLE-N
WLCA12-2NLD WLCA12-2NLD-N
WLCL-LE WLCL-LE-N
WLCL-LD WLCL-LD-N
WLHL-LE WLCL-2NLE-N
WLHL-LD WLCL-2NLD-N
WLCL-2LE WLCL-2LE-N
WLCL-2LD WLCL-2LD-N
WLCL-2NLE WLCL-2NLE-N
WLCL-2NLD WLCL-2NLD-N
WLHAL4-LE WLCAL4-LE-N
WLHAL4-LD WLCAL4-LD-N
WLHAL5-LE WLCAL5-LE-N
WLHAL5-LD WLCAL5-LD-N
WLCA32-41LE WLCA32-41LE-N
WLCA32-41LD WLCA32-41LD-N
WLCA32-42LE WLCA32-42LE-N
WLCA32-43LE WLCA32-43LE-N
WLCA32-43LD WLCA32-43LD-N
WLD-LE WLD18-LE-N
WLD-LD WLD18-LD-N
WLD2-LE WLD28-LE-N
WLD2-LD WLD28-LD-N
WLD3-LE WLD38-LE-N
WL WL-N
WLD3-LD WLD38-LD-N
WLD28-LE WLD28-LE-N
WLD28-LD WLD28-LD-N
WLSD-LE WLSD-LE-N
WLSD-LD WLSD-LD-N
WLSD2-LE WLSD2-LE-N
WLSD2-LD WLSD2-LD-N
WLSD3-LE WLSD3-LE-N
WLSD3-LD WLSD3-LD-N
WLNJ-LE WLNJ-LE-N
WLNJ-LD WLNJ-LD-N
WLNJ-30LE WLNJ-30LE-N
WLNJ-30LD WLNJ-30LD-N
WLNJ-2LE WLNJ-2LE-N
WLNJ-2LD WLNJ-2LD-N
WLNJ-S2LE WLNJ-S2LE-N
WLNJ-S2LD WLNJ-S2LD-N
WLCA2-LDK13 WLCA2-LDK13-N
WLCA2-55LDK13 WLCA2-55LDK13-N
WLCA2-LDK43 WLCA2-LDK43-N
WLCA2-55LDK43 WLCA2-55LDK43-N
WLD2-LDK13 WLD28-LDK13-N
WLD2-55LDK13 WLD28-55LDK13-N
WLD2-LDK43 WLD28-LDK43-N
WLD2-55LDK43 WLD28-55LDK43-N
WLH2-LDK13 WLCA2-LDK13-N
WLH2-55LDK13 WLCA2-55LDK13-N
WLH2-LDK43 WLCA2-LDK43-N
WLH2-55LDK43 WLCA2-55LDK43-N
WLCA2-55LD-M1J WLCA2-55LD-M1J-N
WLCA2-LD-M1GJ WLCA2-LD-M1GJ-N
WLCA2-55LD-M1GJ
WLCA2-55LD-M1GJ-N
WLCA2-55LD-M1JB
WLCA2-55LD-M1JB-N
WLCA2-LD-DGJ03 WLCA2-LD-DGJ-N
WLCA2-55LD-DGJ03 WLCA2-55LD-DGJ-N
WLCA2-LD-DK1EJ03 WLCA2-LD-DK1EJ-N
WLCA2-55LD-DK1EJ03 WLCA2-55LD-DK1EJ-N
WLD2-LD-M1J WLD28-LD-M1J-N
WLD2-55LD-M1J WLD28-55LD-M1J-N
WLD2-LD-M1GJ WLD28-LD-M1GJ-N
WLD2-55LD-M1GJ
WLD28-55LD-M1GJ-N
WLD2-55LD-M1JB
WLD28-55LD-M1JB-N
WLD2-LD-DGJ03 WLD28-LD-DGJ-N
WLD2-LD-DK1EJ03 WLD28-LD-DK1EJ-N
WLD2-55LD-DK1EJ03
WLD28-55LD-DK1EJ-N
WLH2-LD-M1J WLCA2-LD-M1J-N
WLH2-LD-M1GJ WLCA2-LD-M1GJ-N
WLH2-LD-DGJ03 WLCA2-LD-DGJ-N
WLCA2-55 WLCA2-55-N
WLCA2-55LD WLCA2-55LD-N
WL WL-N
WL-N/WLM-N
43
WLCA2-55LE WLCA2-55LE-N
WLCA2-139 WLCA2-139-N
WLCA2-139LD2 WLCA2-139LD2-N
WLCA2-139LD3 WLCA2-139LD3-N
WLCA2-140 WLCA2-140-N
WLCA2-141 WLCA2-141-N
WLCA2-141LD2 WLCA2-141LD2-N
WLCA2-141LD3 WLCA2-141LD3-N
WLCA2-RP60 WLCA2-RP60-N
WLCA2-RP60LD2
WLCA2-RP60LD2-N
WLCA2-RP60LD3
WLCA2-RP60LD3-N
WLCA2-TH WLCA2-TH-N
WLCA2-TC WLCA2-TC-N
WLCA2-RP WLCA2-RP-N
WLCA2-P1 WLCA2-P1-N
WLH2-55 WLCA2-55-N
WLH2-55LD WLCA2-55LD-N
WLH2-55LE WLCA2-55LE-N
WLH2-139 WLCA2-139-N
WLH2-140 WLCA2-140-N
WLH2-141 WLCA2-141-N
WLH2-141LD3 WLCA2-141LD3-N
WLH2-RP60 WLCA2-RP60-N
WLH2-RP60LD3 WLCA2-RP60LD3-N
WLH2-TH WLCA2-TH-N
WLH2-TC WLCA2-TC-N
WLH2-RP WLCA2-RP-N
WLH2-P1 WLCA2-P1-N
WLCA2-255 WLCA2-255-N
WLCA2-255LD WLCA2-255LD-N
WLCA2-255LE WLCA2-255LE-N
WLCA2-2139 WLCA2-2139-N
WLCA2-2139LD2 WLCA2-2139LD2-N
WLCA2-2139LD3 WLCA2-2139LD3-N
WLCA2-2RP60 WLCA2-2RP60-N
WLCA2-2RP60LD2 WLCA2-2RP60LD2-N
WLCA2-2RP60LD3 WLCA2-2RP60LD3-N
WLCA2-2TH WLCA2-2TH-N
WLCA2-2TC WLCA2-2TC-N
WLCA2-2N55 WLCA2-2N55-N
WLCA2-2N55LD WLCA2-2N55LD-N
WLCA2-2N55LE WLCA2-2N55LE-N
WLCA2-2N139 WLCA2-2N139-N
WLCA2-2N140 WLCA2-2N140-N
WLCA2-2NTH WLCA2-2NTH-N
WLCA2-2NTC WLCA2-2NTC-N
WLCA12-55 WLCA12-55-N
WLCA12-55LD WLCA12-55LD-N
WLCA12-55LE WLCA12-55LE-N
WLCA12-139 WLCA12-139-N
WLCA12-140 WLCA12-140-N
WLCA12-141 WLCA12-141-N
WL WL-N
WLCA12-RP60 WLCA12-RP60-N
WLCA12-TH WLCA12-TH-N
WLCA12-TC WLCA12-TC-N
WLCA12-RP WLCA12-RP-N
WLCA12-P1 WLCA12-P1-N
WLH12-TH WLCA12-TH-N
WLH12-TC WLCA12-TC-N
WLH12-RP WLCA12-RP-N
WLH12-P1 WLCA12-P1-N
WLCA12-2TH WLCA12-2TH-N
WLCA12-2TC WLCA12-2TC-N
WLCA12-2NTH WLCA12-2NTH-N
WLCA12-2NTC WLCA12-2NTC-N
WLCL-55 WLCL-55-N
WLCL-55LD WLCL-55LD-N
WLCL-139 WLCL-139-N
WLCL-140 WLCL-140-N
WLCL-RP60 WLCL-RP60-N
WLCL-TH WLCL-TH-N
WLCL-TC WLCL-TC-N
WLCL-RP WLCL-RP-N
WLCL-P1 WLCL-P1-N
WLHL-TH WLCL-2NTH-N
WLHL-TC WLCL-2NTC-N
WLHL-RP WLCL-2NRP-N
WLHL-P1 WLCL-2NP1-N
WLGL-TH WLGL-TH-N
WLCL-2TH WLCL-2TH-N
WLCL-2TC WLCL-2TC-N
WLCL-2RP WLCL-2RP-N
WLCL-2NTH WLCL-2NTH-N
WLCL-2NTC WLCL-2NTC-N
WLD2-55 WLD28-55-N
WLD2-55LD WLD28-55LD-N
WLD2-55LE WLD28-55LE-N
WLD2-139 WLD28-139-N
WLD2-RP60 WLD28-RP60-N
WLD2-TH WLD28-TH-N
WLD2-TC WLD28-TC-N
WLD2-RP WLD28-RP-N
WLD28-55 WLD28-55-N
WLD28-55LD WLD28-55LD-N
WLD28-55LE WLD28-55LE-N
WLD28-139 WLD28-139-N
WLD28-140 WLD28-140-N
WLD28-RP60 WLD28-RP60-N
WLD28-TH WLD28-TH-N
WLD28-RP WLD28-RP-N
WLSD-55 WLSD-55-N
WLSD-55LD WLSD-55LD-N
WLSD-139 WLSD-139-N
WLSD-RP60 WLSD-RP60-N
WL WL-N
WLSD-TH WLSD-TH-N
WLSD-TC WLSD-TC-N
WLSD-RP WLSD-RP-N
WLSD2-55 WLSD2-55-N
WLSD2-55LD WLSD2-55LD-N
WLSD2-139 WLSD2-139-N
WLSD2-140 WLSD2-140-N
WLSD2-RP60 WLSD2-RP60-N
WLSD2-TH WLSD2-TH-N
WLSD2-TC WLSD2-TC-N
WLSD2-RP WLSD2-RP-N
WLNJ-55 WLNJ-55-N
WLNJ-55LD WLNJ-55LD-N
WLNJ-139 WLNJ-139-N
WLNJ-140 WLNJ-140-N
WLNJ-RP60 WLNJ-RP60-N
WLNJ-TH WLNJ-TH-N
WLNJ-TC WLNJ-TC-N
WLNJ-RP WLNJ-RP-N
WLNJ-255 WLNJ-255-N
WLNJ-255LD WLNJ-255LD-N
WLNJ-2140 WLNJ-2140-N
WLNJ-2RP60 WLNJ-2RP60-N
WLNJ-2RP WLNJ-2RP-N
WLCA2-LEAS WLCA2-LEAS-N
WLH2-LEAS WLCA2-LEAS-N
WLCA2-LDAS WLCA2-LDAS-N
WLH2-LDAS WLCA2-LDAS-N
WLCA2-LES WLCA2-LES-N
WLH2-LES WLCA2-LES-N
WLCA2-LDS WLCA2-LDS-N
WLH2-LDS WLCA2-LDS-N
WLD28-LES WLD28-LES-N
WLD28-LDS WLD28-LDS-N
WLMCA2-LD WLMCA2-LD-N
WLMCA2-LDK13A WLMCA2-LDK13A-N
WLMCA2-LDK13 WLMCA2-LDK13-N
WLMCA2-LDK43A WLMCA2-LDK43A-N
WLMCA2-LDK43 WLMCA2-LDK43-N
WLMCA2-LD-M1J WLMCA2-LD-M1J-N
WLMCA2-LD-DGJ03 WLMCA2-LD-DGJ-N
WLMH2-LD WLMCA2-LD-N
WLMH2-LDK13A WLMCA2-LDK13A-N
WLMH2-LDK13 WLMCA2-LDK13-N
WLMH2-LDK43A WLMCA2-LDK43A-N
WLMH2-LDK43 WLMCA2-LDK43-N
WLMH2-LD-M1J WLMCA2-LD-M1J-N
WLMH2-LD-DGJ03 WLMCA2-LD-DGJ-N
WLRCA2 WLRCA2-N
WLRH2 WLRCA2-N
WLRCA2-2 WLRCA2-2-N
WLRCA2-2N WLRCA2-2N-N
WL WL-N
WL-N/WLM-N
44
WLRCA2 WLRCA2-N
WLRH2 WLRCA2-N
WLRCA2-2 WLRCA2-2-N
WLRCA2-2N WLRCA2-2N-N
WLRCL WLRCA2-N
WLRCA2-2 WLRCA2-2-N
WLRCA2-2N WLRCA2-2N-N
WLRCA32 WLRCA32-N
WLRCA2-LDS WLRCA2-LDS-N
WLRH2-LES WLRCA2-LES-N
WLRH2-LDS WLRCA2-LDS-N
WL WL-N
WL-N/WLM-N
45
Model Replacement Table (Replacing WL-N High-sensitivity and High-
precision Models with WL High-sensitivity and High-precision Models)
The WL-N high-sensitivity and high-precision models have been integrated into the WL Series. To use a WL-N high-sensitivity or high-precision
model, find the corresponding WL high-sensitivity or high-precision model in the following model replacement table, and order the switch with the
WL model number. Refer to the WL catalog for detailed information on WL high-sensitivity and high-precision models.
WL-N WL
WLG2-TH-N
WL01G2-TH-F
WLG2-TH-F
WLG2-TH
WLG2-N WL01G2
WLG2
WLG2-LDS-N WL01G2-LDS
WLG2-LDS
WLG2-LD-N WL01G2-LD
WLG2-LD
WLG2-LD-M1J-N WL01G2-LD-M1J
WLG2-LD-M1J
WLG2-LD-M1JB-N WLG2-LD-M1JB 0.3M
WLG2-LD-M1GJ-N WLG2-LD-M1GJ 0.3M
WLG2-LD-DGJ-N WL01G2-LD-DGJ03
WLG2-LD-DGJ03
WLG12-TH-N WL01G12-TH
WLG12-TH
WLG12-N WL01G12
WLG12
WLRG2-N WLR01G2
WLRG2
WLRG2-LDS-N WLRG2-LDS
WLMGCA2-LD-N WLMGCA2-LD
WLMGCA2-LD-M1J-N WLMGCA2-LD-M1J
WLMGCA2-LDK43-N WLMGCA2-LDK43
WLMGCA2-LDK13-N WLMGCA2-LDK13
WLMGCA2-LDK13A-N
WLMGCA2-LDK13A
WLMG2-LD-N WLMG2-LD
WLMG2-LD-M1J-N WLMG2-LD-M1J
WLMG2-LDK43-N WLMG2-LDK43
WLMG2-LDK13-N WLMG2-LDK13
WLMG2-LDK13A-N WLMG2-LDK13A
WLMG2-LD-DGJ-N WLMG2-LD-DGJ03
WLGL-TH-N WLGL-TH
WLGL-TC-N WLGL-TC
WLGL-P1-N WLGL-P1
WLGL-N WL01GL
WLGL
WLGL-LE-N WLGL-LE
WLGL-LD-N WLGL-LD
WLGCA2-TH-N
WL01GCA2-TH
WLGCA2-2TH
WLGCA2-TH
WLGCA2-TC-N WLGCA2-TC
WLGCA2-RP-N WLGCA2-RP
WLGCA2-RP60-N 5M WLGCA2-RP60
WLGCA2-RP60LD3-N
5M WLGCA2-RP60LD3
WLGCA2-RP60LD2-N
5M WLGCA2-RP60LD2
WLGCA2-N WL01GCA2
WLGCA2
WLGCA2-LES-N WLGCA2-LES
WLGCA2-LE-N WL01GCA2-LE
WLGCA2-LE
WLGCA2-LDS-N WLGCA2-LDS
WLGCA2-LDS-M1J-1-N
WLGCA2-LDS-M1J-1
WLGCA2-LDS-M1GJ-1-N
WLGCA2-LDS-M1GJ-1
WLGCA2-LD-N WL01GCA2-LD
WLGCA2-LD
WLGCA2-LD-M1J-N WLGCA2-LD-M1J
WLGCA2-LD-M1GJ-N WLGCA2-LD-M1GJ
0.3M
WLGCA2-LDK43-N WL01GCA2-LDK43
WLGCA2-LDK43
WLGCA2-LDK13-N WLGCA2-LDK13
WLGCA2-LD-DGJ-N WLGCA2-LD-DGJ03
WLGCA2-55-N WLGCA2-55
WLGCA2-55LE-N WLGCA2-55LE
WLGCA2-55LD-N WL01GCA2-55LD
WLGCA2-55LD
WLGCA2-55LD-M1J-N
WLGCA2-55LD-M1J
0.3M
WLGCA2-55LD-M1JB-N
WLGCA2-55LD-M1JB
0.3M
WLGCA2-55LD-M1GJ-N
WLGCA2-55LD-M1GJ
0.3M
WLGCA2-55LDK43-N WL01GCA2-55LDK43
WLGCA2-55LDK43
WLGCA2-55LDK13-N
WL01GCA2-55LDK13
WLGCA2-55LDK13
WLGCA2-55LDK13CE
WLGCA2-55LD-DGJ-N
WLGCA2-55LD-DGJ03
WLGCA2-139-N 5M WLGCA2-139 5M
WLGCA2-139-N 3M WLGCA2-139 3M
WLGCA2-139-N 2M WLGCA2-139 2M
WLGCA2-
139LD3-N 5M
WLGCA2-
1395LD3 S-FLEX 5M
WLGCA2-139LD3-N 5M
WLGCA2-139LD3 5M
WLGCA2-139LD2-N 5M
WLGCA2-139LD2 5M
WLG2-TC-N WLG2-TC
WLG2-RP-N WLG2-RP
WLG2-RP60-N 5M WLG2-RP60
WLG2-RP60-N 10M WLG2-RP60 10M
WLG2-RP60LD3-N 5M
WLG2-RP60LD3
WLG2-RP60LD2-N 5M
WLG2-RP60LD2
WLG2-P1-N WLG2-P1
WLG2-LES-N WLG2-LES
WLG2-LE-N WL01G2-LE
WLG2-LE
WLG2-LEAS-N WLG2-LEAS
WLG2-LDK43-N WLG2-LDK43
WLG2-LDK13-N WL01G2-LDK13
WLG2-LDK13
WLG2-LD-DK1EJ-N WLG2-LD-DK1EJ03
WLG2-LDAS-N WLG2-LDAS
WLG2-55-N WL01G2-55
WLG2-55
WLG2-55LE-N WLG2-55LE
WLG2-55LD-N WL01G2-55LD
WLG2-55LD
WLG2-55LD-M1TJ-N WLG2-55LD-M1TJ
WLG2-55LD-M1TJB-N
WLG2-55LD-M1TJB
WLG2-55LD-M1JB-N WLG2-55LD-M1JB
WLG2-55LD-M1GJ-N
WLG2-55LD-M1GJ 0.3M
WL-N WL
WLG2-55LDK43-N WL01G2-55LDK43
WLG2-55LDK43
WLG2-55LDK13-N
WL01G2-55LDK13
WLG2-55LDK13
WLG2-55LDK13CE
WLG2-55LD-DTK1EJ-N WLG2-55LD-DTK1EJ03
WLG2-55LD-DK1EJ-N WLG2-55LD-DK1EJ03
WLG2-55LD-DGJ-N WL01G2-55LD-DGJ03
WLG2-55LD-DGJ03
WLG2-141-N 5M WLG2-141 5M
WLG2-141-N 2M WLG2-141 2M
WLG2-141LD3-N 5M WL01G2-141LD3 5M
WLG2-141LD3 5M
WLG2-141LD2-N 5M WLG2-141LD2 5M
WLG2-140-N 5M WLG2-140 5M
WLG2-139-N 5M WLG2-139 5M
WLG2-139-N 3M WLG2-139 3M
WLG2-139LD3-N 5M WLG2-139LD3 5M
WLG12-TC-N WLG12-TC
WLG12-P1-N WLG12-P1
WLG12-LE-N WLG12-LE
WLG12-LD-N WLG12-LD
WL-2H4100-N
(FOR WLGL-N) ---
WL-2H2100-N
(FOR WLG12-N) ---
WL-2H1100W-N
(FOR WLG2-141-N) ---
WL-2H1100S-N
(FOR WLG2-S-N) ---
WL-2H1100-N
(FOR WLG2-N) ---
WL-N WL
WL-N/WLM-N
46
Safety Precautions
Be sure to ground. If not, there is the possibility that electrical shock
occurs.
Do not touch charged switch terminals while the switch has carry
current, otherwise there is the possibility that electrical shock
occurs.
Do not disassemble the limit switch or touch inside of it under
supplying power, otherwise there is the possibility that electrical
shock occurs.
Do not touch the wire or rod type actuator in order to prevent injury.
Connect a fuse which has 1.5 to 2 times higher breaking current
than the switch rated current to the switch in series in order to
prevent the switch from short-circuit damage.
On the occasion when using the switch with GB ratings, use a 10A
fuse that complies IEC60269, either type gG.
The durability of switch is depends on the operating condition.
Be sure to check the condition with actual using condition before
using, and use with the number of times of operating without a
performance problem.
Do not drop the switch. Otherwise, there is the possibility that the
switch functions may be spoiled.
Do not connect a Single Limit Switch to two power supplies that are
different in polarity or type.
Be sure to keep the load current less than the rated value.
Otherwise, there is the possibility that the switch may be damage
and/or burnout.
Minimum operating load: 5 VDC 1 mA, resistive load, P level
Note: The P level indicates the standard malfunction level at a
reliability level of 60% (λ60).
(JISC5003) λ60 = 0.1 × 10-6 per operation, which indicates an
estimated malfunction of 1 out of every 10,000,000 operations
at a reliability level of 60%.
Do not use the Switch by itself in atmospheres containing
flammable or explosive gases. Arcs and heating resulting from
switching may cause fire or explosion.
Be sure to prevent the foreign materials such like a scrapped cable
intrusion in to the switch when wiring. Otherwise, there is the
possibility of spoiling the normal operation.
Never wire to the wrong terminals.
Do not store or use the switch with following place.
Where the temperature fluctuates greatly
Where the humidity is very high and condensation may occur.
Where the vibration is too much
Where receiving direct sunshine.
Where receiving salty wind.
Do not disassemble and/or modify the switch at anytime.
Otherwise, there is the possibility of spoiling the normal operation.
Do not apply the force such like deformation and/or degeneration
to the switch. Otherwise, there is the possibility that the switch
functions may be spoiled.
Environment
Take special care to use where there is fine powder, mud and/or
foreign materials stacking. And check the condition with actual
using condition before using. Then use without a performance
problem.
Do not keep the Switch in locations with corrosive gas, such as
sulfuric gas (H2S or SO2), ammonium gas (NH3), nitric gas (HNO3),
or chlorine gas (Cl2), or high temperature and humidity. Otherwise,
contact failure or corrosion damage may result.
Seal material may deteriorate if a Switch is used outdoor or where
subject to special cutting oils, solvents, or chemicals. Always
appraise performance under actual application conditions and set
suitable maintenance and replacement periods.
Install Switches where they will not be directly subject to cutting
chips, dust, or dirt. The Actuator and Switch must also be protected
from the accumulation of cutting chips or sludge.
Constantly subjecting a Switch to vibration or shock can result in
wear, which can lead to contact interference with contacts,
operation failure, reduced durability, and other problems.
Excessive vibration or shock can lead to false contact operation or
damage. Install Switches in locations not subject to shock and
vibration and in orientations that will not produce resonance.
The Switches have physical contacts. Using them in environments
containing silicon gas will result in the formation of silicon oxide
(SiO2) due to arc energy. If silicon oxide accumulates on the
contacts, contact interference can occur. If silicon oil, silicon filling
agents, silicon cables, or other silicon products are present near
the Switch, suppress arcing with contact protective circuits (surge
killers) or remove the source of silicon gas.
Installing the Switch
To install the Switch, make a mounting panel, as shown in the
following diagram, and tighten screws using the correct torque.
Precautions for Safe Use Precautions for Correct Use
Not Suitable Suitable
+0.2
0
+0.2
0
Front Mounting : Four, 5.2 dia. holes
or M5 tapped holes
Rear Mounting : Four, 6.2 dia. holes
±0.15
30.2
58.7±0.15
WL-N/WLM-N
47
Tightening Torque
If screws are too loose they can lead
to an early malfunction of the Switch,
so ensure that all screws are
tightened using the correct torque.
In particular, when changing the
direction of the Head, make sure that
all screws are tightened again to the
correct torque. Do not allow foreign
objects to fall into the Switch.
Wring
In the case of mounting screw
Use M3.5-nylon insulation covered crimp terminals (round type) for
wiring.
Ex.) V1.25-M3.5(RAP1.25-3.5) (J.S.T. Mfg. Co.,Ltd.)
Appropriate wire size is AWG16 (1.25 mm2).
Do not supply electric power when wiring.
Otherwise electric shock may result.
Do not pull out the wires with excessive force.
It may cause of coming off the wire.
Use crimp terminals for wiring.
In the case of lump unit, to avoid interference
between lump unit and crimp terminals, wire
according to right wiring figure.
Attach the lump unit spring to terminal screw
certainly otherwise it’s possible to be destroyed or
shorted.
The ground terminal is only installed on models
with ground terminals.
In the case of prewired connecter and direct connecter
Holding the connecter certainly when pulling connecter.
Don’t pull the cable holding it.
How to handle
Changing direction of the head
By removing the screws in the two corners of the head, the head
can be set any of four directions. Be sure to change the plunger for
internal operations at the same time.
Built-in Switch
Do not remove or replace the built-in switch.
Overtravel Markers
All Switches with Roller Lever Actuators except for Switches with
Fork Lever Locks and Low-temperature Switches have a set
position marker plate.
To allow the roller lever type actuator to travel properly, set the
roller lever according to the dog or cam stroke so that the
arrowhead of the lever is positioned within overtravel markers as
shown.
Connectors
Tighten the connector with the appropriate torque to prevent
deformation.
Use the OMRON type SC connector series, which is prepared
separately, suitable for outer diameter of cable and inner diameter
of seal rubber.
Make sure to wrap the connector with the seal tape, except the
connector which has O-ring, to keep the sealability.
To conform to CSA, use a CSA certified water tight treated conduit
hub.
Even when the connector is assembled and set correctly, the end
of the cable and the inside of the Switch may come in contact. This
can lead to malfunction, leakage current, or fire, so be sure to
protect the end of the cable from splashes of oil or water and
corrosive gases.
Microload Applications
The switch contacts can be used both for standard loads and
microloads, but once a contact has been used to open and close a
load it can no longer be used for lower loads. Doing so will damage
the contact surface and reduce contact reliability.
If an inrush current or other sudden load occurs during a switch
operation, the switch will begin to degrade severely which can
result in reduced durability.
Use a contact protection circuit if required.
Indicator
Indicator-equipped switch has contacts and indicator in parallel.
When contacts are open, leakage current flows through the indicator
circuit and may cause load's malfunction.
Please check the load's OFF current before use the indicatorequipped
switch. Leakage current may cause load malfunction (i.e., the load
may remain ON). Make sure that the load operating current is higher
than the leakage current.
For countermeasures, refer to technical support on your OMRON
website.
Terminal Plate
By using the Terminal Plate (sold separately), as shown in the
following diagram, the Switch can be used as a single-polarity
double-break switch.
No.
Type Torque Screw type
(1) Head mounting screw 0.78 to 0.88
N•m M3.5 screw
(2) Cover mounting screw 1.18 to 1.37
N•m M4 screw
(3) Allen-head bolt
(for securing the roller lever)
4.90 to 5.88
N•m
M5 hexagon socket
head cap screw
(3)
Allen-head bolt
(for securing the adjustable
rod lever)
0.88 to 1.08
N•m
M8 hexagon socket set
screw
(4) Terminal screw 0.59 to 0.78
N•m M3.5 screw
(5) Connector 1.77 to 2.16
N•m
G1/2orPg13.5orM20or
1/2-14NPT
(6)
Unit mounting screw 4.90 to 5.88
N•m M5 screw
Back mounting screws 4.90 to 5.88
N•m M6 screw
(3)
(4)
(2)
(1)
(6)
(5)
Excessive OT
Setting range
Shortage OT
Setting range
Excessive OT
Arrowhead
Screw down
Head
Terminal Plate
Attach the Terminal Plate
so that the “COM” mark is
oriented as shown on the left.
Terminal Plate Mounting Diagram
(with Two Terminal Screws Removed)
Model WL-N TERMINAL PLATE
WL-N/WLM-N
48
Using a WL@-2N Switch Mounted from the Side
If you replace a previous Switch with a WL@-2N-N Switch, a Mounting
Plate (sold separately) is available to maintain mounting compatibility.
If you use the Mounting Plate, the Switch mounting holes and actuator
position will be compatible. (The position of the dog will not need to
be changed.)
Operation
Carefully determine the position and shape of the dog or cam so that
the actuator will not abruptly snap back, thus causing shock. In order
to operate the Limit Switch at a comparatively high speed, use a dog
or cam that keeps the Limit Switch turned ON for a sufficient time so
that the relay or valve will be sufficiently energized.
The method of operation, the shape of the cam or dog, the
operating frequency, and the travel after operation have a large
influence on the durability and operating accuracy of the Limit
Switch. The cam or dog must be smooth in shape.
Appropriate force must be imposed on the actuator by the cam or
dog in both rotary operation and linear operation.
If the dog touches the lever as shown below, the operating position
will not be stable.
Unbalanced force must not be imposed on the actuator. Otherwise,
wear and tear on the actuator may result.
With a roller actuator, the dog must touch the actuator at a right
angle. The actuator or shaft may deform or break if the dog touches
the actuator (roller) at an oblique angle.
Make sure that the actuator does not exceed the OT (overtravel)
range, otherwise the Limit Switch may malfunction. When mounting
the Limit Switch, be sure to adjust the Limit Switch carefully while
considering the whole movement of the actuator.
The Limit Switch may soon malfunction if the OT is excessive.
Therefore, adjustments and careful consideration of the position of
the Limit Switch and the expected OT of the operating body are
necessary when mounting the Limit Switch.
When using a pin-plunger actuator, make sure that the stroke of the
actuator and the movement of the dog are located along a single
straight line.
Others
For long term (over a year) storage, check according to Operating
characteristics, Contact resistance and Dielectric strength at least.
And check with using condition.
The durability of the Switch is greatly affected by operating
conditions.
Evaluate the Switch under actual working conditions before
permanent installation and use the Switch within a number of
switching operations that will not adversely affect the Switch’s
performance.
23
64
30.2
58.7
WL@-2N
Mounting Plate
Replacing a Switch
with the WL@-2N-N
Mounting Plate
Set
contents
Model WLN-P001
Plate mounting
bolts (2)
Plate (1)
Switch mounting
bolts (2)
Incorrect Correct
Snapped
back
Abruptly
actuated
Incorrect Correct
Snapped
back Abruptly
actuated
Incorrect
Dog Dog
Correct
Incorrect Correct
RollerRoller
Dog Dog
CorrectIncorrect
Dog
Dog
Operating
body
Install a stopper.
PT (Pretravel)
FP (Free position)
OP (Operating position)
OT (Overtravel)
TTP (Total travel position)
Reference line
70% of
rated OT 100% of
rated OT
Distance to the
optimum setting range.
Optimum setting range
Correct
Stopper
Incorrect Correct
Operating
body
Operating
body
WL-N/WLM-N
49
Using the Switches
Item Applicable models and Actuators Details
Changing the Installation Position
of the Actuator
By loosening the Allen-head bolt on
the actuator lever, the position of the
actuator can be set anywhere within
the 360°.
With Indicator-equipped Switches, the
actuator lever comes in contact with
the top of the indicator cover, so use
caution when rotating and setting the
lever.
When the lever only moves forwards
and backwards, it will not contact the
lamp cover.
(This does not apply to Long-life
Switches.)
Roller Levers:
(WLCA2-N, WLCA2-2-N,
WLCA2-2N-N, WLG2-N,
WLCA2-7-N, WLCA2-8-N,
WLGCA2-N *, WLMCA2-N,
WLMG2-N *, WLMGCA2-N *)
Adjustable Roller Levers:
(WLCA12-N, WLCA12-2-N,
WLCA12-2N-N, WLG12-N *)
Adjustable rod lever:
(WLCL-N, WLCL-2-N,
WLCL-2N-N, WLGL-N *,
WLCAL4-N, WLCAL5-N)
Changing the Orientation of the
Head
By removing the two screws of the
Head, the Head can be set in any of
the four directions.
Be sure to change the plunger for
internal operations at the same time.
The roller plunger can be set in either
of two positions at 90 .
Roller Levers:
(WLCA2-N, WLCA2-2-N,
WLCA2-2N-N, WLG2-N *,
WLCA2-7-N, WLCA2-8-N,
WLGCA2-N *, WLMCA2-N,
WLMG2-N *, WLMGCA2-N *)
Adjustable Roller Levers:
(WLCA12-N, WLCA12-2-N,
WLCA12-2N-N, WLG12-N *)
Adjustable rod lever:
(WLCL-N, WLCL-2-N,
WLCL-2N-N, WLGL-N *,
WLCAL4-N, WLCAL5-N *)
Horizontal plunger
(WLSD@-N)
Sealed top-roller plunger
(WLD28-N)
Note: Does not include the -RP60
Series, -141 Series
Fork lever lock:
(WLCA32-4@-N)
Changing the Operating Direction
By removing the Head on models
which can operate on one-side only,
and then changing the direction of the
operational plunger, one of three
operating directions can be selected.
Roller Levers:
(WLCA2-N, WLCA2-2-N,
WLCA2-2N-N, WLG2-N *,
WLCA2-7-N, WLCA2-8-N,
WLMCA2-N, WLMG2-N *)
Adjustable Roller Levers:
(WLCA12-N, WLCA12-2-N,
WLCA12-2N-N, WLG12-N *)
Adjustable rod lever:
(WLCL-N, WLCL-2-N,
WLCL-2N-N, WLGL-N *,
WLCAL4-N, WLCAL5-N)
WLGCA2-N *, WLMGCA2-N *
Loosen the Allen-head bolt, set
the actuator's position and then
tighten the bolt again.
Head Loosen the screws.
Operating Operating OperatingNot operating Operating Not operating
Operation in both
directions
Clockwise operation Counterclockwise
operation
The output of the Switch will be
changed, regardless of which
direction the lever is pushed.
p
The output of the Switch will
only be changed when the lever
is pushed in one direction.
Operating Operating Operating
Not operating
Operating Not operating
Operation in both
directions
Clockwise operation Counterclockwise
operation
WL-N/WLM-N
50
* Manufacturing of the high-sensitivity, high-precision models has been discontinued and the models have been integrated into the WL Series.
This information is provided as reference for comparison of specifications. Refer to the model replacement table on page 45 and order WL-series
high-sensitivity or high-precision models.
Operation of Fork Lever Locks
A Switch with a Fork Lever Lock is constructed so that the dog pushes the lever to invert the output and this inverted state is maintained even after
the dog moves on.
If the dog then pushes the lever from the opposite direction, the lever will return to its original position.
Installing the Roller on the Inside
By installing the roller lever in the
opposite direction, the roller can be
installed on the inside.
(Set so that operation can be
completed within a 180° level range.)
Roller Levers:
(WLCA2-N, WLCA2-2-N,
WLCA2-2N-N, WLG2-N *,
WLCA2-7-N, WLCA2-8-N,
WLGCA2-N *, WLMCA2-N,
WLMG2-N *, WLMGCA2-N *)
Fork lever lock:
(WLCA32-4@-N)
Note: Except for Switches with
variable roller levers.
Adjusting the Length of the Rod or
Lever
The length of the rod or lever can be
adjusted by loosening the Allen-head
bolt.
Adjustable Roller Levers:
(WLCA12-N, WLCA12-2-N,
WLCA12-2N-N, WLG12-N *)
Adjustable rod lever:
(WLCL-N, WLCL-2-N,
WLCL-2N-N, WLGL-N *, WLCAL4-N)
Selecting the Roller Position
There are four types of Switches with
Fork Lever Locks for use depending on
the roller position.
Fork lever lock:
(WLCA32-4@-N)
An explanation of the operation of fork lever locks is provided after this
table.
Item Applicable models and Actuators Details
Loosen the
Allen-head bolt.
Loosen this
Allen-head bolt
and adjust the
length of the rod.
Adjustment
range radius:
25 to 89 mm
Adjustable Roller Levers: Adjustable Rod Levers:
Loosen this
Allen-head bolt
and adjust the
length of the
lever.
Adjustment
range radius:
24 to 140 mm
WLCA32-41-N WLCA32-43-N
WLCA32-42-N WLCA32-44-N
NC terminal: ON NO terminal: ON NO terminal: ON
Example
WL-N/WLM-N
51
Limit Switch Connectors
Connectors (SC Series)
Cabtire cables and flexible tubes with various diameters are used to
connect machine tools and controllers with Limit Switches. To ensure
the watertightness of the edges of the conduits, use an SC Connector
that is suitable for the external diameter of cable and model of Limit
Switch.
Ordering Information
Connector for Cabtire Cable
Note: Please use sealing tape with SC Connectors. SC-1M to SC-5M, however, are provided with an O-ring (NBR) and therefore sealing tape is not necessary to ensure
a proper seal.
Simple Connectors (Not Suitable for Locations Subject to Oil or Water)
Note: Simple connector are made of resin. If more sealing capability is required, use one of SC-1M to SC-5M, which have metal casings.
Models marked with an asterisk (*) however, can only be used with resin connectors.
Conduit Applicable cable Inner diameter (D)
of seal rubber
External diameter of cable Model Applicable model
Min. Max.
JIS B 0202 G½
Cabtire cable (general-
purpose)
7 mm 5.5 mm 7.5 mm SC-1M
WL-N, WL, D4A-@N, D4B-@N,
ZE, ZV, ZV2, XE, XV, XV2
9 mm 7.5 mm 9.5 mm SC-2M
12.5 mm 11 mm 13 mm SC-3M
14 mm 12 mm 14 mm SC-4M
11 mm 9 mm 11 mm SC-5M
Cabtire cable (anti-
corrosive)
7 mm 5.5 mm 7.5 mm SC-21
9 mm 7.5 mm 9.5 mm SC-22
12.5 mm 11 mm 13 mm SC-23
14 mm 12 mm 14 mm SC-24
11 mm 9 mm 11 mm SC-25
½-14NPT Cabtire cable
7 mm 5.5 mm 7.5 mm SC-1PT
D4A-@N
9 mm 7.5 mm 9.5 mm SC-2PT
12.5 mm 11 mm 13 mm SC-3PT
14 mm 12 mm 14 mm SC-4PT
11 mm 9 mm 11 mm SC-5PT
Conduit Applicable cable Inner diameter (D)
of seal rubber
External diameter of cable Model Applicable model
Min. Max.
JIS B 0202 G½
Cabtire cable
10.6 mm 8.5 mm 10.5 mm SC-P2 WL-N, WL, D4A-@N, D4B-@N,
ZE, ZV, ZV2, XE, XV, XV2
Pg13.5 9.6 mm 7.5 mm 9.5 mm SC-P3 WL@-G-N
JIS B 0202 G½ 9 mm 7.5 mm 9 mm SC-6 WL-N, WL, D4A-@N, D4N *,
D4N-@R *, D4B-@N, ZE, ZV,
ZV2, XE, XV, XV2
WL-N/WLM-N
52
Dimensions and Structure (Unit: mm)
Connectors for Cabtire Cable
As for models without an O-ring, please use sealing tape with SC Connectors.
Note: Dimensions not shown in the above diagrams have a variation of ±0.4 mm.
Simple Connectors (Not Suitable for Locations Subject to Oil or Water)
Note: Dimensions not shown in the above diagrams have a variation of ±0.4 mm.
* Diameter of Part Marked with Asterisk
14 dia.
14.6 dia.
27.7
29.3
*E 15 4.8
9
(34)
24
JIS B 0202 G½
*D
Sealing rubber
(nitrile rubber)
Connector
(brass and nickel plating)
Washer (stainless steel)
Ball head lock nut
(brass and nickel plating)
Metal Models without O-ring
SC-21 to 25
3029.3
15 5 9
27
14 dia.
14.6 dia.
*E
(34)
JIS B 0202 G½
Sealing rubber (nitrile rubber)
*D
Sealing rubber
(nitrile rubber)
Connector
(zinc die-cast and
zinc plating)
Washer (stainless steel)
Ball head lock nut
(zinc die-cast and zinc plating)
Metal Models with O-ring
SC-1M to 5M
27.729.3
15 514
24
14 dia. 14 dia.
14.6 dia.
(39)
½-14NPT
*D
Sealing rubber (nitrile rubber)
Connector
(zinc die-cast and
zinc plating)
Washer (stainless steel)
Ball head lock nut
(zinc die-cast and zinc plating)
Metal Models without O-ring
½-14NPT
(U.S.-standard screws)
SC-1PT to 5PT
22
25.4
15 1 4.5
5
10.6 dia.12.6 dia. 18 dia.18 dia.
JIS B 0202
G½
Hexagonal nut
(polyacetal resin)
Conduit washer
(ferrous metal and
zinc plating)
Ring (chloroprene rubber)
Resin Models
SC-P2
21
23.5
15.5 14.5
5
Pg13.5
9.6 dia.12 dia.
18 dia.18 dia.
Hexagonal nut
(polyacetal resin)
Conduit washer
(ferrous metal and
zinc plating)
Ring (chloroprene rubber)
Resin Models
Pg13.5
SC-P3
22.5
26
95
12
9
10
(30.6)
12
9
G½
Ball head lock nut
(polyacetal resin) Sealing rubber (nitrile rubber)
Connector
(polyacetal resin)
M20 × 1.5
Washer
(ferrous metal and
zinc plating)
*D
Resin Models
SC-6
Model Inner diameter (D)
of sealed rubber Internal diameter
(E) of washer Applicable cable
SC-21, -1M, -1PT 7 mm 10.4 mm 5.5 to 7.5-mm dia.
SC-22, -2M, -2PT 9 mm 13.2 mm 7.5 to 9.5-mm dia.
SC-23, -3M, -3PT 12.5 mm 14.6 mm 11 to 13-mm dia.
SC-24, -4M, 4PT 14 mm 14.6 mm 12 to 14-mm dia.
SC-25, -5M, -5PT 11 mm 13.2 mm 9 to 11-mm dia.
SC-6 9 mm 10 mm 7.5 to 9-mm dia.
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have
any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing
by Omron). Omron disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE
PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL
SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products
or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election,
to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the
non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price
of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other
claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored,
installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by
Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or
unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system
assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in
writing, are not to be construed as an amendment or addition to the above warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is
not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system,
or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with
respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it
to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice
to change part numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be
assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to
confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
Authorized Distributor:
In the interest of product improvement,
specifications are subject to change without notice.
Cat. No. C147-E1-04
Printed in Japan
0915 (1013)
© OMRON Corporation 2013-2015 All Rights Reserved.
OMRON Corporation Industrial Automation Company
OMRON ELECTRONICS LLC
2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL 60169 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
Regional Headquarters
OMRON EUROPE B.V.
Wegalaan 67-69, 2132 JD Hoofddorp
The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388
Contact: www.ia.omron.com
Kyoto, JAPAN
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200