The MBC201 Series of open-frame medical power supplies, with its wide universal input range 90-264 VAC, is available at 200 W of output power with forced-air cooling and a variety of single output voltages. The MBC Series is designed and approved to the latest medical standards (EN/IEC 60601-1), providing 2 x MOPP isolation for Class I & Class II applications. These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications. * 5 x 3 x 1.5 Inch Form Factor * 200 W with Forced-Air Cooling * Approved to EN/IEC 60601-1 * High Efficiency > 88% * 12 V Fan & 5 V Standby Outputs * Remote Sense * IEC Protection Class Options: * Class I: Earthing Tab J4 (no suffix) * Class II: No Earthing Tab (-2 suffix) * Medical Safety Agency Approvals * RoHS Compliant * CE Marked * Diagnostic * Dialysis * Drug Pump * Home Health Care * Monitoring * Portable Equipment MBC201 Series 2 CONNECTOR OUTPUT VOLTAGE MAX LOAD CONVECTION 2 MAX L2AD 300 LFM 2 3, 4 MINIMUM LOAD RIPPLE & NOISE 5 MBC201-1005G JST 5.0 VDC 26.0 A 26.0 A 0.0 A 1% MBC201-1T05G Screw Terminal 5.0 VDC 26.0 A 35.0 A 0.0 A 1% MBC201-1012G JST 12 VDC 13.33 A 16.67 A 0.0 A 1% MBC201-1T12G Screw Terminal 12 13.33 A 16.67 A 0.0 A 1% MBC201-1015G JST 15 10.66 A 13.33 A 0.0 A 1% MBC201-1T15G Screw Terminal 15 10.66 A 13.33 A 0.0 A 1% MBC201-1024G JST 24 6.66 A 8.33 A 0.0 A 1% MBC201-1T24G Screw Terminal 24 6.66 A 8.33 A 0.0 A 1% MBC201-1030G JST 30 5.33 A 6.66 A 0.0 A 1% MBC201-1T30G Screw Terminal 30 5.33 A 6.66 A 0.0 A 1% MBC201-1048G JST 48 3.33 A 4.17 A 0.0 A 1% MBC201-1T48G Screw Terminal 48 3.33 A 4.17 A 0.0 A 1% MODEL1 COVER-201-XBC 6 Metal cover kit accessory Specifications are for nominal input voltage, 25C unless otherwise stated. PARAMETER DESCRIPTION / CONDITION SPECIFICATION Input Voltage Universal 90-264 VAC / 120-390 VDC Input Frequency Input Current Inrush Current Leakage Current Power Factor Switching Frequency 47 to 63 Hz 120 VAC: 230 VAC: 120 VAC: 230 VAC: 120 VAC: 230 VAC: 120 VAC: 230 VAC: PFC converter (variable) Resonant converter (variable) 2.4 A max. 1.2 A max. 35 A max. 65 A max. < 150 A < 300 A 0.99 0.95 35 to 250 kHz, 90 kHz typical 35 to 250 kHz, 90 kHz typical 1 For Class II (without input Earth pin) add suffix -2 (e.g.: MBC201-1012G-2). Combined output power from V1, VSTBY and VFAN should not exceed the total output power rating. 3 Fan output voltage tolerance is +/-20%. During V1 full load, VFAN needs min. 20 mA load to be within regulation band. 4 Peak current for fan output is 1 A. 5 Ripple is 2% up to 20% load and < 1% above 20% load. Ripple is peak to peak with 20 MHz bandwidth and 10 F (Tantalum capacitor) in parallel with a 0.1 F capacitor at rated line voltage and load ranges. 6 When used in Cover Kit, de-rate output power to 70 % under all operating conditions. 2 tech.support@psbel.com MBC201 Series 3 PARAMETER DESCRIPTION / CONDITION SPECIFICATION Efficiency 120 VAC: 230 VAC: 84% typical 86% typical Hold Up Time 120 / 230 VAC 10 ms Derate output power linearly to 80% from 90 V to 80 VAC input. 160 W to 200 W Output Power Peak Power: 250 W for 0.2 s Line Regulation +/-0.5% Load Regulation Transient Response +/-2.0% Main output 50 to 100% load change, 50 Hz, 50% duty cycle, 0.1A / s < 10%, recovery time < 5 ms Rise Time < 100 ms Set Point Accuracy 1% Voltage Adjustment V1 3% Over Voltage Protection V1 only 110 to 150 % Over Current Protection Short Circuit Protection 110% typical above rating Short term, auto recovery PARAMETER Operating Temperature DESCRIPTION / CONDITION Refer to derating curve (Figure 1) SPECIFICATION -20 to 70C -20 to 0C Start-up is guaranteed Storage Temperature -40 to 70 C 5 V model Cooling Other models Convection: 300 LFM: Convection: 300 LFM: 130 W 175 W 160 W 200 W Humidity Non Condensing 95% Altitude Operating: Non-Operating: 10,000 ft. 40,000 ft. Reliability MTBF according to Telcordia -SR332-Issue 3 1.6 million hours Conducted Emissions Input Current Harmonics EN 55011-B, CISPR22-B, FCC PART15-B EN 55011 A; with external core (King core K5B RC 25x12x15-M in input cable) EN 61000-3-2 Pass Pass Level B Class D Voltage Fluctuation and Flicker EN 61000-3-3 Pass ESD Immunity EN 61000-4-2 Level 4, Criterion A Radiated Field Immunity EN 61000-4-3 Level 3, Criterion A Electrical Fast Transient Immunity EN 61000-4-4 Level 3, Criterion A Surge Immunity EN 61000-4-5 Level 3, Criterion A Conducted Immunity EN 61000-4-6 Level 3, Criterion A Magnetic Field Immunity EN 61000-4-8 Level 4, Criterion A Voltage Dips, Interruptions EN 61000-4-11 Criterion A & B Radiated Emissions Europe, Middle East +353 61 225 977 North America +1 408 785 5200 (c) 2017 Bel Power Solutions & Protection BCD.00289_AF Asia-Pacific +86 755 298 85888 MBC201 Series 4 PARAMETER DESCRIPTION / CONDITION SPECIFICATION Isolation Voltage Input to Output: Min. 5900 VDC Safety Standards Approved to the latest edition of the following standards: CSA/UL60601-1, EN60601-1 and IEC60601-1. Agency Approvals Nemko, UL, C-UL CE mark Complies with LVD Directive PARAMETER DESCRIPTION / CONDITION Power Good Signal TTL signal goes high after main output is in regulation band. Delay is 0.1 to 0.3 sec. Power Fail Signal TTL signal goes low 1 ms advance before output goes out of regulation due to mains failure Remote ON / OFF To turn-on power supply short J3 pin 4 to pin 6 (PSU is shipped in this configuration) Remote Sense Compensates for 200 mV cable drop CONNECTOR PIN DESCRIPTION / CONDITION Pin 1 AC Neutral Pin 2 AC Line AC Input Connector J1 DC Output Connector J2 Pin 1,2,3 Pin 4,5,6 RTN Vout Signals & Aux Power7 J3 Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 +VE Remote Sense VFAN (+12 V/0.5 A) -VE Remote Sense Remote ON/OFF VSTBY (+5 V/1 A, +/-5%) RTN (Signal) Power Fail Power Good Earthing Tab J4 MANUFACTURER / PN Molex: 26-60-4030 or equivalent; Mating: 09-50-3031; Pins: 08-50-0106 Option 1: Tyco: 2-1776112-3 or equivalent Mating: 13 AWG wire Option 2: JST: B6P-VH-B (LF) (SN) or B6P-VH (LF) (SN) or equivalent Mating: VHR-6M; Pins: SVH-41T-P1.1 Molex: 22-23-2081 or equivalent Mating: 22-01-2087, Pins: 08-50-0113 Molex: 19705-4301 or equivalent Mating: 190030001 PARAMETER DESCRIPTION / CONDITION Weight 325 g (0.72 lbs.) Dimensions 127.0 x 76.2 x 38.1 mm (5 x 3 x 1.5 inch) Cooling Convection: 83 W; 300 LFM: 175 W (5 V model) Convection: 160 W; 300 LFM: 200 W (other models) 7 PSU is supplied with J3 housing, pin-4 and pin-6 shorted to enable main output without remote on/off feature tech.support@psbel.com MBC201 Series 5 Convection load: 83 W up to 40 C De-rate above 40 C @ 1.89% per C Forced air cooled load: 130 W up to 50C (for screw terminal version) De-rate above 50 C @ 1.63% per C Forced air cooled load: 175 W up to 50C (for JST connector version) De-rate above 50 C @ 2.5% per C Convection load: 160 W up to 40 C De-rate above 40 C @ 2% per C Forced air cooled load: 200 W up to 50C De-rate above 50 C @ 2.5% per C Figure 1. Derating Curves Europe, Middle East +353 61 225 977 North America +1 408 785 5200 (c) 2017 Bel Power Solutions & Protection BCD.00289_AF Asia-Pacific +86 755 298 85888 MBC201 Series 6 Figure 2 - Mechanical Drawing NOTES: In case the PCB is mounted in a metal enclosure, using metal hardware ensure the following: 1 Stand off, used to mount PCB has OD of 5.4 mm max. 2 Screws, used to fix PCB on stand off, have head dia of 6.0 mm max. 3 Washer, if used, to have dia of 6.5 mm max. NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. tech.support@psbel.com