Maximum ratings, at Tj=25 °C, unless otherwise specified
Parameter Symbol Conditions Unit
Power dissipation
2.5
Operating and storage temperature
IEC climatic category; DIN IEC 68-1 55/150/56
Parameter Symbol Conditions Unit
min. typ. max.
Thermal characteristics
Thermal resistance, junction - case
RthJA 6 cm2 cooling area2) - - 50
Electrical characteristics, at Tj=25 °C, unless otherwise specified
Static characteristics
Drain-source breakdown voltage
V(BR)DSS VGS=0 V, ID=10 mA 30 - - V
Breakdown voltage temperature
coefficient
ID=10 mA, referenced
to 25 °C
-15 - mV/K
Gate threshold voltage
VGS(th) VDS=VGS, ID=250 µA 1.2 - 2 V
Zero gate voltage drain current
IDSS VDS=24 V, VGS=0 V - - 0.5 mA
VDS=24 V, VGS=0 V,
Tj=125 °C
- 3 -
Gate-source leakage current
IGSS VGS=20 V, VDS=0 V -10 100 nA
Drain-source on-state resistance
RDS(on) VGS=4.5 V, ID=30 A -1.2 1.5 mW
VGS=10 V, ID=30 A -0.9 1.1
|VDS|>2|ID|RDS(on)max,
ID=30 A
3) See figure 3 for more detailed information
Rev. 2.2 page 2 2013-05-14