BeStar Technologies Inc.
: Specification
: Electro-magnetic Sound Generator Component
: HCM1203X
SoniCrest Brand Acoustic Components
www.jlsonicrest.com
Document Type
Product Type
Part Number
This material is the property of BeStar Technologies Inc.
Unauthorized copying or use of this material is prohibited.
HCM1203X
Rev. A6
Page 2 of 5
Purpose and Scope
This document contains both general requirements, qualification requirements, and those specific
electrical, mechanical requirements for this part.
Description
Ø12mm electro-magnetic sound generator with built-in oscillation circuit, RoHS compliant.
Application
Computers and Peripherals, Portable Equipment, Automobile Electronics, POS System, Household
Appliances, etc.
Component Requirement
4.1 General Requirement
4.1.1. Operating Temperature Range
4.1.2. Storage Temperature Range
4.1.3. Weight
4.2 Electrical Requirement
4.2.1. Rated Voltage
4.2.2. Operating Voltage
4.2.3. Rated Current
4.2.4. Generated Frequency
4.2.5. Sound Pressure Level at 10cm
(Applying rated voltage)
4.3 Mechanical Requirement
4.3.1. Layout and Dimension
4.
3.
2.
1.
: -40°C to +85°C
: -40°C to +85°C
: Approx. 2 g
: 3VDC
: 2 ~ 5 VDC
: <=30mA
: 2300 ± 300 Hz
: >=85dB
: See Section 6, Figure 3
HCM1203X
Rev. A6
Page 3 of 5
Figure 1. Frequency Testing Circuit
Figure 2. Test Setup
Notes : Input rated voltage into samples. Measure SPL using a calibrated SPL meter
10cm from the alert port. Sound level meter to be in accordance with IEC651 (1979)
Type 1 and/or ANSI S1.4-1983. The meter must be checked on a daily basis using a
calibrated acoustic calibrator recommended by the manufacturer. Measurement should
be carried out in a free field environment or at least 40cm from any surface.
4.4 Test Setup of SPL and Frequency Measurement
To Test Unit
10cm
Test Unit
Input DC Voltage
-
+
To Frequency Counter
SPL Meter
10.6W
HCM1203X
Rev. A6
Page 4 of 5
Reliability Test
5.1. Operating Life : Subject samples to room condition for 1000 hours with rated voltage.
Components must be fully stabilized before data is taken, which may require up to a 2
hours soak.
5.2. High Temperature : Subject samples to +85 °C for 96 hours. Components must be fully
stabilized at temperature extremes before data is taken, which may require up to a 2 hours
soak.z a
5.3. Low Temperature : Subject samples to -40°C for 96 hours. Components must be fully
stabilized at temperature extremes before data is taken, which may require up to a 2 hours
soak.
5.4. Temperature Cycle : Each temperature cycle shall consist of 30 minutes at -25°C, 15
minutes at +20°C, 30 minutes at +80°C and 15 minutes at +20°C. Test duration is for 5
cycles. Components must be fully stabilized at temperature extremes before data is taken,
which may require up to a 2 hours soak.
5.5. Static Humidity Cycle : Each cycle shall coniest of +25°C with 90% to 95% relative
humidity for 10 hours and + 65°C with 90 to 95% relative humidity for 12 hours. Test
duration is for 5 cycles. Finally dry at room ambient for 2 hours before taking final
measurement.
5.6. Drop Test : Drop samples naturally from the height of 1m onto a wooden board (10mm
thickness) each directions (x, y and z).
5.7. Solderability Test :Pins shall be immersed in molten solder maintained at +255°C±5°C for
a period of 3 seconds.
5.
HCM1203X
Rev. A6
Page 5 of 5
Mechanical Layout
Unit : mm
Tolerance : Linear XX.X
XX.XX
Angular
(unless otherwise specified)
6.
Figure 3. HCM1203X Mechanical Layout
Side View
Top View
= ±0.3
= ±0.05
= ±0.25°
Bottom View
Ø12.0
Sealing Label
JL
HCM1
7.6
9.5 6.5±0.5
Ø0.6
HCM1203X
JL XXX
3 Digits Date Code
5.0