PRODUCT DATASHEET European Region + 44 (0) 208 920 2306 www.energizer.eu AA Rechargeable AA-2300 (HR6) Specifications Industry Standard Dimensions Classification: Chemical System: ACCU Rechargeable Nickel-Metal Hydride (NiMH) Designation: Nominal Voltage: Rated Capacity: IEC-HR6 1.2 Volts 2300 mAh (to 1.0 volts) Based on 460 mA (0.2C) discharge rate Typical Weight: Typical Volume: Jacket: 28.0 grams 8.3 cubic centimeters Plastic Label (mm) 14.50 13.50 1.00 Minimum 5.50 Maximum Internal Resistance: The internal resistance of the cell varies with state of charge, as follows: Cell 1/2 Discharged Cell Charged 30 milliohms 40 milliohms (tolerance of 20% applies to above values) 50.50 49.20 AC Impedance (No Load): 7.00 Minimum The impedance of the charged cell varies with frequency, as follows: Typical Discharge Characteristics Cell Voltage 1.4 1000 1.3 230 mA (0.1C) 1.2 460 mA (0.2C) 1.1 Above values based on AC current set at 1.0 ampere. Value tolerances are 20%. 1.0 Operating and Storage Temperatures: 0.9 0 3 6 Hours of Discharge 9 12 To maintain maximum performance, observe the following general guidelines regarding environmental conditions. Charge: Discharge: Storage: Humidity: Typical Performance at 21C 1.4 Cell Voltage Impedance (milliohms) (Charged Cell) 12 Frequency (Hz) Typical Performance at 21C 1.3 1.2 1.1 4.6 A (2.0C) 1.0 1.15 A (0.5C) 2.3 A (1.0C) 0C to 40C 0C to 50C -20C to 30C 6520% Operating at extreme temperatures, will significantly impact battery cycle life. 0.9 0.0 0.5 1.0 1.5 2.0 2.5 Hours of Discharge Important Notice This datasheet contains information specific to battery chargers manufactured at the time of its publication. (c)Energizer Holdings, Inc. - Contents herein do not constitute a warranty. Form No. EBC - 889959EU Page 1 of 1