R.46 S Loose X2 CLASS (IEC 60384-14) - MKP Series metallized polyPROPYLENE film capacitor SELF-HEALING PROPERTIES Taped Fig.1 VERSION Fig.2 Typical applications: This special R46 release is designed for applications in series with the main . PRODUCT CODE: R46 O d 0.05 p 15 22.5 p 27.5 p = 37.5 0.6 or 0.8* 0.8 1.0 *See size table. All dimensions are in mm. Pitch Box thickness (B) (mm) (mm) Maximum dimensions (mm) B max H max L max 10.0 15.0 15.0 22.5 27.5 37.5 B +0.2 B +0.2 B +0.2 B +0.2 B +0.2 B +0.3 All <7.5 7.5 All All All H +0.1 H +0.1 H +0.1 H +0.1 H +0.1 H +0.1 GENERAL TECHNICAL DATA test method and performance Dielectric: polypropylene film. Damp heat, steady state: Plates: metal layer deposited by evaporation under vacuum. Test conditions 1st Winding: non-inductive type. Temperature: +40C 2C Relative humidity (RH): 93% 2% Test duration: 56 days Leads: tinned wire. Protection: plastic case, thermosetting resin filled. Box material is solvent resistant and flame retardant according to UL94 V0. Test conditions 2nd Temperature: +60C 2C Relative humidity (RH): 95% 2% Test duration: 500 hours Marking: Manufacturer's logo, series, capacitance, tolerance, rated voltage, capacitor class, dielectric code, climatic category, passive flammability category, manufacturing date code, approvals, manufacturing plant. Test conditions 3rd Temperature: +40C 2C Relative humidity (RH): 93% 2% Test duration: 500 hours Voltage value: 230 Vac, 50 Hz Climatic category: 40/110/56 IEC 60068-1 Operating temperature range: -40 to +110C Related documents: IEC 60384-14, EN 60384-14. electrical characteristics Rated voltage (VR): Capacitance range: 275Vac (50/60Hz) / 560 Vdc Performance Dielectric strength: no dielectric breakdown or flashover at 4.3 x VR (d.c.)/1 min Capacitance change |C/C|: 5% Insulation resistance: 50% of initial limit. 0.022F to 10F Capacitance values: E6 series (IEC 60063 Norm). Capacitance tolerances (measured at 1 kHz): 10% (K); 20% (M). tolerance 5% (J) available upon request Endurance: Test conditions Temperature: Test duration: Voltage applied: Dissipation factor (DF): tg 10-4 at +25C 5C: 15 (8)* at 1kHz * Typical value Temperature: Voltage charge time: Voltage charge: Performance 1x105 M (5x105 M )* 30000 s (150000 s )* * Typical value +110C 2C 1000 h 1.25 x VR +1000Vac 0.1 s/h Performance Insulation resistance: Test conditions L +0.2 L +0.3 L +0.5 L +0.3 L +0.3 L +0.3 Dielectric strength: +25C5C 1 min 100 Vdc no dielectric breakdown or flashover at 4.3 x VR (d.c.)/1 min Capacitance change |C/C|: 10% Insulation resistance: 50% of initial limit. Resistance to soldering heat: Test conditions for C0.33F for C>0.33F Solder bath temperature: +260C 5C Dipping time (with heat screen):10 s 1 s Test voltage between terminations (on all pieces): 1500Vac for 1 s + 2200Vdc for 1 s at +25C5C Performance Capacitance change |C/C|: 2% 155 09/2008 R.46 S VERSION X2 CLASS (IEC60384-14) - MKP Series metallized polyPROPYLENE film capacitor SELF-HEALING PROPERTIES APPROVALS Rated Cap. (*) 275 Vac / 560 Vdc Std dimensions Od Max dv/dt at 390Vdc Part Number (**) B H L p (V/ s) 0.010 F 5.0 11.0 18.0 15.0 0.6 400 R46 KI 2100 - - S0 - 0.015 F 5.0 11.0 18.0 15.0 0.6 400 R46 KI 2150 - - S0 - 0.022 F 5.0 11.0 18.0 15.0 0.6 400 R46 KI 2220 - - S0 - 0.033 F 5.0 11.0 18.0 15.0 0.6 400 R46 KI 2330 - - S0 - 0.047 F 5.0 11.0 18.0 15.0 0.6 400 R46 KI 2470 - - S1 - 0.068 F 5.0 11.0 18.0 15.0 0.6 400 R46 KI 2680 - - S0 - 0.10 F 5.0 11.0 18.0 15.0 0.6 400 R46 KI 3100 - - S1 M 0.10 F 6.0 12.0 18.0 15.0 0.6 400 R46 KI 3100 - - S0 - 0.15 F 6.0 12.0 18.0 15.0 0.6 400 R46 KI 3150 - - S1 M 0.15 F 7.5 13.5 18.0 15.0 0.6 400 R46 KI 3150 - - S0 - 0.15 F 9.0 12.5 18.0 15.0 0.6 400 R46 KI 3150 - - S3 - 0.22 F 7.5 13.5 18.0 15.0 0.6 400 R46 KI 3220 - - S1 M 0.22 F 8.5 14.5 18.0 15.0 0.6 400 R46 KI 3220 - - S0 - 0.22 F 6.0 17.5 18.0 15.0 0.6 400 R46 KI 3220 - - S2 - 0.22 F 9.0 12.5 18.0 15.0 0.6 400 R46 KI 3220 - - S3 - 0.33 F 13.0 12.0 18.0 15.0 0.8 400 R46 KI 3330 - - S1 - 0.33 F 8.5 14.5 18.0 15.0 0.8 400 R46 KI 3330 - - S3 M 0.33 F 10.0 16.0 18.0 15.0 0.8 400 R46 KI 3330 - - S0 - 0.33 F 7.5 18.5 18.0 15.0 0.8 400 R46 KI 3330 - - S2 - 0.47 F 11.0 19.0 18.0 15.0 0.8 400 R46 KI 3470 - - S0 - 0.47 F 10.0 16.0 18.0 15.0 0.8 400 R46 KI 3470 - - S1 M 0.56 F 11.0 19.0 18.0 15.0 0.8 400 R46 KI 3560 - - S0 - 0.68 F 11.0 19.0 18.0 15.0 0.8 400 R46 KI 3680 - - S0 M 0.22 F 6.0 15.0 26.5 22.5 0.8 200 R46 KN 3220 - - S0 - 0.33 F 6.0 15.0 26.5 22.5 0.8 200 R46 KN 3330 - - S1 M 0.33 F 7.0 16.0 26.5 22.5 0.8 200 R46 KN 3330 - - S0 - 0.47 F 7.0 16.0 26.5 22.5 0.8 200 R46 KN 3470 - - S1 M 0.47 F 8.5 17.0 26.5 22.5 0.8 200 R46 KN 3470 - - S0 - 0.68 F 10.0 18.5 26.5 22.5 0.8 200 R46 KN 3680 - - S0 - 1.0 F 10.0 18.5 26.5 22.5 0.8 200 R46 KN 4100 - - S2 M 1.0 F 11.0 20.0 26.5 22.5 0.8 200 R46 KN 4100 - - S1 - 1.2 F 13.0 22.0 26.5 22.5 0.8 200 R46 KN 4120 - - S0 - 0.47 F 9.0 17.0 32.0 27.5 0.8 150 R46 KR 3470 - - S0 - 0.68 F 9.0 17.0 32.0 27.5 0.8 150 R46 KR 3680 - - S1 - 1.0 F 11.0 20.0 32.0 27.5 0.8 150 R46 KR 4100 - - S1 - 1.5 F 13.0 22.0 32.0 27.5 0.8 150 R46 KR 4150 - - S1 - 2.2 F 13.0 25.0 32.0 27.5 0.8 150 R46 KR 4220 - - S2 3.3 F 18.0 33.0 32.0 27.5 0.8 150 R46 KR 4330 - - S2 4.7 F 18.0 33.0 32.0 27.5 0.8 150 R46 KR 1.5 F 11.0 22.0 41.5 37.5 1.0 100 2.2 F 11.0 22.0 41.5 37.5 1.0 100 R46 KW 4220 - - S2 M 2.2 F 13.0 24.0 41.5 37.5 1.0 100 R46 KW 4220 - - S1 - 3.3 F 16.0 28.5 41.5 37.5 1.0 100 R46 KW 4330 - - S1 - 4.7 F 16.0 28.5 41.5 37.5 1.0 100 R46 KW 4470 - - S2 M 4.7 F 19.0 32.0 41.5 37.5 1.0 100 R46 KW 4470 - - S1 - 6.8 F 20.0 40.0 41.5 37.5 1.0 100 R46 KW 4680 - - S2 - 10.0 F 30.0 45.0 41.5 37.5 1.0 100 R46 KW 5100 - - S1 - Class X2 File No.V4413 UL 1414 (up to 1F, 85C; 250Vac) Across-the-line File No.E97797 CSA - C22.2 No.1 (up to 1F, 85C; 250Vac) Across-the-line certified for Canada File No.E97797 UL 1283 (310 Vac) Electromagnetic Interference Filters File No.E85238 CSA - C22.2 No.8 (310 Vac) Electromagnetic Interference Filters certified for Canada File No.E85238 GB/T 14472 Class X2 File CQC03001008199 CQC03001008842 Approved according to IEC 60384-14 According to IEC 60065 (**)ENEC mark has replaced all the following European National marks: Table 1 Standard packaging style Lead length Taping style Ordering code (Digit 10 to 11) P2 (mm) Fig. (No.) Pitch (mm) AMMO-PACK AMMO-PACK 12.70 19.05 1 2 10.0/15.0 22.5 DQ DQ - REEL O500mm - REEL O500mm 12.70 19.05 1 2 10.0/15.0 22.5/27.5 CK CK 4470 - - S2 - R46 KW 4150 - - S1 - Loose, short leads Loose, long leads Loose, long leads (mm) Loose, insulated rigid leads Loose, insulated flexible leads 04 +2 25 -1/+2 30 +5 00 50 40 30 +5 51 150 5 52 Note: Ammo-pack is the preferred packaging for taped version. Rated voltage (K=275Vac) Mechanical version and packaging (Table 1) Tolerance: K (10%); M (20%) 300Vac Available upon request E12 Series available upon request All dimensions are in mm 09/2008 ENEC IEC 60384-14 156