July 2011
78-8135-4313-5-E
3M Multiport Grommet Kit
For Use With 3M Fiber Optic Splice Closure 2178 Family
Instructions
1.0 Kit Contents
a. Hose clamp
b. Multiport grommet
c. Blank plugs
d. Silicone lubricant
e. Cable strain relief bracket
f. K-connector (small)
g. Screw (small)
h. K-connector (large)
i. Screw (large)
Note: Visually inspect all components. If any
component is missing or appears damaged,
do not install. Call 3M customer service at
1-800-426-8688 for a replacement product.
B
A
E
F, G
DC
3M Multiport Grommet 1.4" O.D.
A
B
C
D
3M Multiport Grommet 1.0" O.D. 2178-4PGR-0.28
A
B
H, I
C
D
F, G
3M Multiport Grommet 1.0" O.D.
3
278-8135-4313-5-E
2.0 Drop Cable Preparation
2.1 Determine how many drop cables will be
passing through the 3M Multiport Grommet.
2.2 Remove sheath on drops exposing buffer tubes
to a length required per company practice.
Note: An additional method to ease installation is to
take sheath scuff supplied in closure kits, and
slightly sand the leading edge of the drop cable
and blank plugs.
2.3 Trim the strength members back to 1.75"
(44.4 mm) in length.
2.4 Place a small amount of lubricant (provided in
kit) on blank plugs and cable to allow for ease
of installation into multiport grommet.
Note: Follow health, safety and environmental
information on product label or Material Safety
Data Sheet (MSDS) for Silicone Lubricant.
2.5 Grease approximately 2" of cable drop jacket.
2.6 Insert drops into multiport grommet first and
then insert blank plugs last.
2.7 Insert drop 1"–2" into multiport grommet and
then pull back out.
2.8 Insert drop the entire length of multiport
grommet.
2.9 Repeat steps 2.4–2.8 for the blank plugs as well.
Note: Leave future ports orientated to top of closure
for ease of future installations of drop.
1.75"
(44.4 mm)
3
78-8135-4313-5-E
3.0 3M Multiport Grommet 4-Port (1.0") Installation
3.1 Orient the grommet as shown with one drop
port positioned at top. Insert the two strength
members from the top drop cable and the
upper strength members from the drop cables
on either side (four total) into the center large
K-connector. Insert the remaining strength
members into the small K-connectors on either
side.
3.2 Secure cable strain relief bracket to the
grommet with the hose clamp as shown. Tighten
the hose clamp to 40 inch-lbs. ± 5 inch-lbs.
(4.6 N•m ± 0.6 N•m).
Note: Ensure that the extruded retention feature of
strain relief has sufficient contact with surface
of grommet.
Extruded
Retention Feature
3.3 Tighten the three K-connector nuts to
40 inch-lbs. ± 5 inch-lbs. (4.6 N•m ± 0.6 N•m)
each.
478-8135-4313-5-E
4.0 3M Multiport Grommet 6-Port (1.4") Installation
4.1 Break off the tab feature as shown on both cable
strain relief brackets.
4.2 Place cable strain relief brackets on either side
of the grommet, with three drops on either side
as shown. Insert cable strength members into
small K-connectors.
4.3 Secure cable strain relief brackets and the
strain relief bracket from the closure to the
grommet with the hose clamp as shown. Tighten
the hose clamp to 40 inch-lbs. ± 5 inch-lbs.
(4.6 N•m ± 0.6 N•m).
Note: Ensure that extruded retention feature of
strain relief has sufficient contact with surface
of grommet.
4.4 Tighten the six K-connector nuts to
40 inch-lbs. ± 5 inch-lbs. (4.6 N•m ± 0.6 N•m)
each.
5
78-8135-4313-5-E
5.0 Cable Port Seal Assembly
5.1 Place a small amount of lubricant (provided in
kit) on blank plugs and cable to allow for ease
of installation into 3M Multiport Grommet.
Note: Carefully follow health, safety and
environmental instructions as given on
Material Safety Data Sheet (MSDS) for the
silicone lubricant.
5.2 Place cable strain relief and multiport grommet
assembly into closure.
5.3 Place cable ties around multiport grommet
assembly inside and out as shown.
Note: White cable ties are shown for clarity.
5.4 Follow closure instruction for all other
preparation leading up to and including sealing
closure.
3M Fiber Optic Splice Closure 2178-XSB
3M Fiber Optic Splice Closure 2178-XLB
3M Fiber Optic Splice Closure 2178-XL
3M Fiber Optic Splice Closure 2178-S
3M Fiber Optic Splice Closure 2178-LS
3M Fiber Optic Splice Closure 2178-LL
3M is a trademark of 3M Company.
Important Notice
All statements, technical information, and recommendations related to 3M’s products are based on information believed to be reliable,
but the accuracy or completeness is not guaranteed. Before using this product, you must evaluate it and determine if it is suitable for
your intended application. You assume all risks and liability associated with such use. Any statements related to the product which are not
contained in 3M’s current publications, or any contrary statements contained on your purchase order shall have no force or effect unless
expressly agreed upon, in writing, by an authorized officer of 3M.
Warranty; Limited Remedy; Limited Liability.
This product will be free from defects in material and manufacture for a period of one (1) year from the time of purchase. 3M MAKES NO
OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3M’s option,
to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be
liable for any indirect, special, incidental or consequential loss or damage arising from this 3M product, regardless of the
legal theory asserted.
3
Communication Markets Division
6801 River Place Blvd.
Austin, TX 78726-9000
1-800-426-8688
www.3MTelecommunications.com
Please Recycle. Printed in USA.
© 3M 2011. All Rights Reserved.
78-8135-4313-5-E