REVISION A NOTES: 1. C REPRESENTS A CRITICAL DIMENSION. 2. ALL DIMENSIONS TO BE ABOUT CL WITHIN .005[0.13]. 3. MINIMUM PUSHOUT FORCE: 3 lbs. 4. MAXIMUM CUT FLASH: .020[0.50]. 5. MEASURE FROM THE TIPS OF THE TERMINALS. 6. MEASURE AT BOTH ENDS OF PART. A 7. PARTS TO BE PACKAGED IN TUBES FOR 4-50 POSITIONS (.100 [2.54] PITCH) OR 2-25 POSITIONS (.200 [5.08] PITCH), OTHERWISE BULK PACKAGED. DO NOT SCALE FROM THIS PRINT BTSW-XXX-XX-X-S-XX-XX TERMINAL SPACE -1: .100[2.54 (FILL EVERY POSITION) -2: .200[5.08] (FILL EVERY OTHER POS STARTING AT -01 AND ENDING IN LAST POS) NO OF POSITIONS -1: -01 THRU -50 -2: -02 THRU -25 (SEE FIG. 3, SHEET 2) POLARIZATION XX INDICATES POSITION TO BE OMITTED; LEAVE BLANK FOR NO OPTION OPTIONS -LL: LOCKING LEAD (SEE FIG. 2, SHEET 2) ROW SPECIFICATION -S: SINGLE TERMINAL SPECIFICATION -01: .050[1.27] PROFILE *-02: .060[1.52] PROFILE (SEE TABLE 1) PLATING SPECIFICATION -T: MATTE TIN CONTACT AND TAIL -F: FLASH GOLD, 3 Au / 50 Ni MIN ON CONTACT,MATTE TIN ON TAIL (USE T-1S6-XX-GF-2) 01 .100 2.54 REF * = NOT RELEASED .025 0.64 SQ REF (TYP) 2 MAX SWAY (TYP) .100 2.54 REF (TYP) +.015 +0.38 (No. OF POSITIONS x .100[2.54]) - .010 [ - 0.25 ] C T-1S6-XX-XXX-2 2 MAX SWAY (TYP) TSM-50-SV "B".005 (SEE NOTE 5 & 6) .100 2.54 REF 90 (TYP) REF C "A".005 (SEE NOTE 5 & 6) C "C" FIG. 1 BTSW-1XX-XX-X-S SHOWN TUBE VIEW * = NOT RELEASED UNLESS OTHERWISE SPECIFIED, DIMENSIONS ARE IN INCHES. TOLERANCES ARE: DECIMALS ANGLES .XX: .01[.3] .XXX: .005[.13] .XXXX: .0020[.051] 2 PROPRIETARY NOTE THIS DOCUMENT CONTAINS INFORMATION CONFIDENTIAL AND PROPRIETARY TO SAMTEC, INC. AND SHALL NOT BE REPRODUCED OR TRANSFERRED TO OTHER DOCUMENTS OR DISCLOSED TO OTHERS OR USED FOR ANY PURPOSE OTHER THAN THAT WHICH IT WAS OBTAINED WITHOUT THE EXPRESSED WRITTEN CONSENT OF SAMTEC, INC. DO NOT SCALE DRAWING PT-1-24-01-60 (USE TP-03) (SEE NOTE 7) MATERIAL: BODIES: DUPONT CRASTIN SK652 FR, COLOR: BLACK TERMINALS: PHOSPHOR BRONZE F:\DWG\MISC\MKTG\BTSW-XXX-XX-X-S-XX-XX-MKT.SLDDRW SHEET SCALE: 3:1 520 PARK EAST BLVD, NEW ALBANY, IN 47150 PHONE: 812-944-6733 FAX: 812-948-5047 e-Mail info@SAMTEC.com code 55322 DESCRIPTION: .025 [.64] SQ. SINGLE ROW, DOUBLE -RA POST ASM DWG. NO. BTSW-XXX-XX-X-S-XX-XX BY:J. BROWNING 04/27/2010 SHEET 1 OF 2 REVISION A CL 01 ODD POSITION PART .008 0.20 (TYP) CL .017 0.43 MIN (TYP) .040 1.02 01 EVEN POSITION PART FIG. 2 BTSW-1XX-XX-X-S-LL SHOWN (SAME AS FIG. 1 EXCEPT AS SHOWN) LOCKING LEAD OPTION = CRIMP LOCATION IF CRIMP POSITION IS POLARIZED, MOVE ONE POSITION TOWARD PIN 1 .200 5.08 FIG. 3 BTSW-210-XX-X-S SHOWN (SAME AS FIG. 1 EXCEPT AS SHOWN) "E" C "D" REF PROPRIETARY NOTE THIS DOCUMENT CONTAINS INFORMATION CONFIDENTIAL AND PROPRIETARY TO SAMTEC, INC. AND SHALL NOT BE REPRODUCED OR TRANSFERRED TO OTHER DOCUMENTS OR DISCLOSED TO OTHERS OR USED FOR ANY PURPOSE OTHER THAN THAT WHICH IT WAS OBTAINED WITHOUT THE EXPRESSED WRITTEN CONSENT OF SAMTEC, INC. DO NOT SCALE DRAWING IN-PROCESS 1 SHEET SCALE: 3:1 * = NOT RELEASED F:\DWG\MISC\MKTG\BTSW-XXX-XX-X-S-XX-XX-MKT.SLDDRW 520 PARK EAST BLVD, NEW ALBANY, IN 47150 PHONE: 812-944-6733 FAX: 812-948-5047 e-Mail info@SAMTEC.com code 55322 DESCRIPTION: .025 [.64] SQ. SINGLE ROW, DOUBLE -RA POST ASM DWG. NO. BTSW-XXX-XX-X-S-XX-XX BY: J. BROWNING 04/27/2010 SHEET 2 OF 2