Amphenol(R) Assembly Instructions-C36 TNC CRIMP-CRIMP TYPES outer ferrule bushing male contact plug body assembly This part is used only with RG-62 cable Amphenol Number Connector Type Hex Crimp Data Cable RG-/U Cavity for Contact Cavity for Outer Ferrule Die Set for Tool 227-944 Stripping Dimensions, inches (mm) CTL Series Tool No. a b c 36825 TNC Plug 58, 141 .068(1.7) .213(5.4) 227-1221-11 CTL-1 .593(15.1) .250(6.4) 31-2318 TNC Bulkh. Jack 174, 188, 316 .068(1.7) .178(4.5) 227-1221-09 CTL-2 .593(15.1) .250(6.4) .156(4.0) .156(4.0) 31-2367 TNC Plug 58, 141 .068(1.7) .213(5.4) 227-1221-11 CTL-1 .593(15.1) .250(6.4) .156(4.0) 31-2367-RFX TNC Plug 58, 141, 142A .068(1.7) .213(5.4) 227-1221-11 CTL-1 .630(16.0) .303(7.7) .156(4.0) 31-2368 TNC Plug 59, 62 .068(1.7) .255(6.5) 227-1221-13 CTL-1 .593(15.1) .250(6.4) .156(4.0) 31-2373 TNC Plug 55, 142, 223 .068(1.7) .213(5.4) 227-1221-11 CTL-1 .593(15.1) .250(6.4) .156(4.0) 31-2381 TNC Angle Plug 55, 142, 223, 400 .068(1.7) .213(5.4) 227-1221-11 CTL-1 .578(14.7) .328(8.3) .125(3.2) 31-4452 TNC Plug 142, 400 .068(1.7) .213(5.4) 227-1221-11 CTL-1 .593(15.1) .250(6.4) .156(4.0) 31-2242 TNC Plug 179,187 .068 (1.7) .178 (4.5) 227-1221-09 CTL-2 .593(15.1) .250(6.4) .156(4.0) 31-2242-RFX TNC Plug 179,187 .068 (1.7) .178 (4.5) 227-1221-09 CTL-2 .590(15.0) .323(8.2) .118(3.0) 31-2264 59,62,140,210 .068 (1.7) .255 (8.5) 227-1221-13 CTL-1 .593(15.1) .250(6.4) .156(4.0) 31-2264-RFX TNC Blkh Jack 59 .068 (1.7) .255 (8.5) 227-1331-13 CTL-1 .689(17.5) .362(9.2) .157(4.0) TNC Blkh Jack 31-2264-RFX TNC Blkh Jack 62 .068 (1.7) .255 (8.5) 227-1331-13 CTL-1 .689(17.5) .362(9.2) .197(5.0) 31-2315 174,188 .068 (1.7) .178 (4.5) 227-1221-09 CTL-2 .593(15.1) .250(6.4) .156(4.0) 31-2315-RFX TNC Plug 174,188,316 .068 (1.7) .178 (4.5) 227-1221-09 CTL-2 .590(15.0) .323(8.2) .118(3.0) 31-2317 TNC Jack 174.188 .068 (1.7) .178 (4.5) 227-1221-09 CTL-2 .590(15.0) .323(8.2) .118(3.0) 31-2318 TNC Blkh Jack TNC Plug 174,187,188 .068 (1.7) .178 (4.5) 227-1221-09 CTL-2 .590(15.0) .323(8.2) .118(3.0) 31-2368-RFX TNC Plug 59 .068 (1.7) .255 (8.5) 227-1221-13 CTL-1 .630(16.0) .303(7.7) .157(4.0) 31-2368-RFX TNC Plug 62 .068 (1.7) .255 (8.5) 227-1221-13 CTL-1 .630(16.0) .303(7.7) .197(5.0) 31-2381 TNC Angle Plug 55,142 .068 (1.7) .213 (5.4) 227-1221-11 CTL-1 .578(14.7) .328(8.3) .125(3.2) 31-2382 TNC Angle Plug 58,141 .068 (1.7) .213 (5.4) 227-1221-11 CTL-1 .578(14.7) .328(8.3) .125(3.2) 31-2383 TNC Angle Plug 62 .068 (1.7) .255 (8.5) 227-1221-13 CTL-1 .689(17.5) .362(9.2) .156(4.0) 31-2389 TNC Blkh Jack .156(4.0) 58,141 .068 (1.7) .213 (5.4) 227-1221-11 CTL-1 .593(15.1) .250(6.4) 31-2389-RFX TNC Blkh Jack 141,142 .068 (1.7) .213 (5.4) 227-1221-11 CTL-1 .689(17.5) .362(9.2) .157(4.0) 31-2367-RFX TNC Plug 58,141 .068 .213 227-1221-11 CTL-1,5 .630 (16.0) .303 (7.7) .157 (4.0) 31-5849-RFX TNC Angle Plug 58,58c Solder .213 227-1221-11 CTL-1,3,5 .709(18) .382(9.7) .161(4.1) 31-6000-RFX TNC Plug 8x,LMR240 .068 .255 227-1221-13 CTL-1,5 .630 (16) .303 (7.7) .157 (4.0) 31-6001-RFX TNC Plug B8214, B9913 Solder .429 227-1221-25 CTL-4 .630 (16) .303 (7.7) .157 (4.0) 31-6002-RFX TNC Angle Plug LMR 400, B9913,B9914 Solder .429 227-1221-25 CTL-4 .728 (18.5) .401 (0.2) .244 (6.2) 31-6003-RFX TNC Angle Plug 8x,LMR240 Solder .255 227-1221-13 CTL-1,5 .728 (18.5) .401 (10.2) .244 (6.2) Step 1 aA bB STEP 1 c C For RG-174, 179, 187, 188, 316/U cables only, slit jacket back .100"(2.5mm) as shown. Before attaching center contact, slide metal spacer/TFE sleeve (not shown) over cable dielectric. The center contact should butt against the dielectric and TFE sleeve. STEP 2 Step 2 contact must butt against cable dielectric Step 3 Step 1 Strip cable jacket, braid, and dielectric to dimensions in table above. All cuts are to be sharp and square. Important: Do not nick braid, dielectric, and center conductor. Slide outer ferrule onto cable as shown. Step 2 Flare slightly end of cable braid as shown to facilitate insertion of inner ferrule. Important: Do not comb out braid. Place contact on cable center conductor so that it butts against cable dielectric. Crimp contact in place using Die Set Cavity indicated in table above. Step 3 Install cable assembly into body assembly so that inner ferrule portion slides under braid. Push cable assembly forward until contact snaps into place in insulator. Slide outer ferrule over braid and up against connector body. Crimp outer ferrule using Die Set Cavity in table above. STEP 3 outer ferrule should butt here cable dielectric must butt insulator Amphenol Corporation Tel: 800-627-7100 www.amphenolrf.com 310