Spectrum Analyzer
Series
DSA800
All-Digital IF Technology
Frequency Range from 9 kHz up to 7.5 GHz
Min. -161 dBm Displayed Average Noise Level (Typ.)
Min. < -98 dBc/Hz @ 10 kHz Offset Phase Noise
Level Measurement Uncertainty < 0.8 dB
10 Hz Minimum Resolution Bandwidth (DSA832/875)
Up to 7.5 GHz Tracking Generator (DSA8XX-TG)
Optional Preampli er (DSA832/875)
Advanced Measurement Functions (Opt.)
EMI Filter & Quasi-Peak Detector Kit (Opt.)
VSWR Measurement Kit (Opt.)
PC Software (Opt.)
Optional RF TX/RX Training Kit
Optional RF Accessories (Cable, Adaptor, Attenuator, Bridge ...)
Complete Connectivity: LAN (LXI), USB Host & Device, GPIB (Opt.)
8 Inch WVGA (800x480) Display
Compact Size, Light Weight Design
RIGOL TECHNOLOGIES,INC.
1RIGOL
Product Dimensions: Width X Height X Depth = 361.6 mm x 178.8 mm x 128 mm
The ability to measure smaller signals: on the basis of this technology, the IF lter enables smaller bandwidth settings,
which greatly reduce the displayed average noise level.
The ability to distinguish between small signals by frequency: using the IF lter with the smallest bandwidth setting, it
is possible to make out signals with a frequency difference of only 10 Hz.
High precision amplitude readings: this technology almost eliminates the errors generated by lter switching,
reference level uncertainty, scale distortion, as well as errors produced in the process of switching between logarithmic
and linear display of amplitude when using a traditional analog IF design.
Higher reliability: compared with traditional analog designs, the digital IF greatly reduces the complexity of the
hardware, the system instability caused by channel aging, and the temperature sensitivity that can contribute to parts
failure.
High measurement speed: the use of digital IF technology improves the bandwidth precision and selectivity of the
lter, minimizing the scanning time and improving the speed of the measurement.
Benets of Rigol's all digital IF design
DSA800 Series Spectrum Analyzer
Basic Keys
RF InputTG OutputUSB Port
Advanced
Measurement Keys
Marker Keys
Readout the spectrum peak values with the
peak table function
Measure lower level signal with the preamplier
turn on
Phase noise < -98 dBc/Hz @10 kHz offset
(DSA832/875) EMI kit (EMI lter & Quasi-peak & Pass/Fail)
The GUI to control the RF demo kit (Transmitter)
directly
VSWR measurement
Compare the spectrums with different color traceDistinguish the two nearby signals clearly with
the 10 Hz RBW (DSA832/875)
Features and Benets
RIGOL 2
RIGOL Spectrum Analyzer Option and Accessory
VSWR Bridge
( VB1020/VB1040/VB1080 )
Rack Mount Kit
( RM-DSA800 )
USB to GPIB Converter
( USB-GPIB )
RF Demo Kit
( TX1000 )
RF CATV KitRF Demo Kit
( RX1000 )
Soft Carrying Bag
( BAG-G1 )
DSA Utility Kit
RF Cable Kit
( CB-NM-NM-75-L-12G )
( CB-NM-SMAM-75-L-12G )
RF Adaptor Kit
High Power Attenuator
( ATT03301H )
RF Attenuator Kit
DSA PC Software
( Ultra Spectrum )
Advanced Measurement Kit
(AMK-DSA800)
Harmonic Distoration TOI Emission
Bandwidth
Channel Power
Time Domain Power
Adjacent Channel Power
Occupied
Bandwidth
Carrier to Noise
Ratio
Pass/Fail
3RIGOL
Specications
Frequency
Frequency
DSA815 DSA832 DSA875
Frequency range 9 kHz to 1.5 GHz 9 kHz to 3.2 GHz 9 kHz to 7.5 GHz
Frequency resolution 1 Hz
Internal Reference Frequency
DSA815 DSA832 DSA875
Reference frequency 10 MHz
Accuracy ± [(time since last adjustment × aging rate) + temperature stability + calibration accuracy]
Initial calibration accuracy <1 ppm
Temperature stability 0 to 50, reference to 25
<2 ppm <0.5 ppm
Aging rate <2 ppm/year <1 ppm/year
Frequency Readout Accuracy
Marker resolution span/ (number of sweep points - 1)
Marker uncertainty ± (frequency indication × frequency reference uncertainty + 1% × span + 10% × resolution
bandwidth + marker resolution)
Frequency Counter
Resolution 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz
Uncertainty ± (frequency indication × reference frequency accuracy + counter resolution)
Frequency Span
Range 0 Hz, 100 Hz to maximum frequency of instrument
Uncertainty ±span/ (number of sweep points - 1)
SSB Phase Noise
20 to 30, fc=1 GHz
Carrier offset DSA815 DSA832 DSA875
10 kHz <-80 dBc/Hz <-98 dBc/Hz
100 kHz <-100 dBc/Hz (typ.) <-100 dBc/Hz (typ.)
Specications are valid under the following conditions: the instrument is within the calibration period, is stored for at least two hours at 0
to 50 temperature, and is warmed up for 40 minutes. Unless otherwise noted, the specications in this manual include the measurement
uncertainty.
Typical (typ.): characteristic performance, which 80 percent of the measurement results will meet at room temperature (approximately 25). This data is not
warranted and does not include the measurement uncertainty.
Nominal (nom.): the expected mean or average performance or a designed attribute (such as the 50 Ω connector). This data is not warranted and is measured at
room temperature (approximately 25).
Measured (meas.): an attribute measured during the design phase which can be compared to the expected performance, such as the amplitude drift variation with
time. This data is not warranted and is measured at room temperature (approximately 25).
NOTE: All charts in this manual are the measurement results of multiple instruments at room temperature unless otherwise noted. The specications (except the
TG specications) listed in this manual are those when the tracking generator is off.
RIGOL 4
Residual FM
20 to 30, RBW = VBW = 1 kHz
DSA815 DSA832 DSA875
Residual FM <50 Hz (nom.) <20 Hz (nom.)
Bandwidths
Set "Auto SWT" to "Accy"
DSA815 DSA832 DSA875
Resolution bandwidth (-3 dB) 100 Hz to 1 MHz,
in 1-3-10 sequence 10 Hz to 1 MHz, in 1-3-10 sequence
RBW uncertainty <5% (nom.)
Resolution lter shape factor
(60 dB: 3 dB) <5 (nom.)
Video bandwidth (-3 dB) 1 Hz to 3 MHz, in 1-3-10 sequence
Resolution bandwidth (-6 dB)
(EMI-DSA800 option) 200 Hz, 9 kHz, 120 kHz
Amplitude
Measurement Range
Range fc ≥ 10 MHz
DANL to +20 dBm
Maximum Input Level
DC voltage 50 V
CW RF power attenuation = 30 dB
+20 dBm (100 mW)
Max. damage level[1] +30 dBm (1 W)
NOTE: [1] When fc ≥ 10 MHz, input level > +25 dBm and PA is Off, the protection switch will be on.
Displayed Average Noise Level (DANL)
DSA815
Frequency attenuation = 0 dB, RBW = VBW = 100 Hz, sample detector, trace average 50, tracking generator
off, 20 to 30, input impendence = 50 Ω
PA off 100 kHz to 1 MHz <-90 dBm, <-110 dBm (typ.)
1 MHz to 1.5 GHz <-110 dBm + 6 × (f/1GHz) dB, <-115 dBm (typ.)
PA on 100 kHz to 1 MHz <-110 dBm, <- 130 dBm (typ.)
1 MHz to 1.5 GHz <-130 dBm + 6 × (f/1GHz) dB, <-135 dBm (typ.)
5RIGOL
Displayed Average Noise Level (DANL)
DSA832 DSA875
Frequency attenuation = 0 dB, RBW = VBW = 10 Hz, sample detector, trace average 50, tracking
generator off, 20 to 30, input impendence = 50 Ω
PA off
9 kHz to 100 kHz <-110 dBm (typ.) <-110 dBm (typ.)
100 kHz to 5 MHz <-125 dBm, <-128 dBm (typ.) <-125 dBm, <-128 dBm (typ.)
5 MHz to 3.2 GHz <-130 dBm, <-134 dBm (typ.) <-130 dBm, <-134 dBm (typ.)
3.2 GHz to 6 GHz <-126 dBm, <-130 dBm (typ.)
6 GHz to 7.5 GHz <-121 dBm, <-125 dBm (typ.)
PA on
100 kHz to 1 MHz <-142 dBm (typ.) <-142 dBm (typ.)
1 MHz to 5 MHz <-142 dBm, <-145 dBm (typ.) <-142 dBm, <-145 dBm (typ.)
5 MHz to 3.2 GHz <-147 dBm, <-151 dBm (typ.) <-147 dBm, <-151 dBm (typ.)
3.2 GHz to 6 GHz <-143 dBm, <-147 dBm (typ.)
6 GHz to 7.5 GHz <-138 dBm, <-142 dBm (typ.)
Displayed Average Noise Level (DANL) (Normalized to 1 Hz)
DSA815 DSA832 DSA875
Frequency attenuation = 0 dB, RBW = VBW = 100 Hz, sample detector, trace average ≥ 50, tracking
generator off, normalized to 1Hz, 20 to 30, input impendence = 50 Ω
PA off
9 kHz to 100 kHz <-120 dBm (typ.) <-120 dBm (typ.)
100 kHz to 1 MHz <-110 dBm,
<-130 dBm (typ.) <-135 dBm,
<-138 dBm (typ.)
<-135 dBm,
<-138 dBm (typ.)
1 MHz to 5 MHz <-130 dBm + 6 × (f/1GHz) dB,
<-135 dBm (typ.)
5 MHz to 1.5 GHz <-140 dBm,
<-144 dBm (typ.)
<-140 dBm,
<-144 dBm (typ.)
1.5 GHz to 3.2 GHz
3.2 GHz to 6 GHz <-136 dBm,
<-140 dBm (typ.)
6 GHz to 7.5 GHz <-131 dBm,
<-135 dBm (typ.)
PA on
100 kHz to 1 MHz <-130 dBm,
<-150 dBm (typ.) <-152 dBm (typ.) <-152 dBm (typ.)
1 MHz to 5 MHz <-150 dBm + 6 × (f/1GHz) dB,
<-155 dBm (typ.)
<-152 dBm,
<-155 dBm (typ.)
<-152 dBm,
<-155 dBm (typ.)
5 MHz to 1.5 GHz <-157 dBm,
<-161 dBm (typ.)
<-157 dBm,
<-161 dBm (typ.)
1.5 GHz to 3.2 GHz
3.2 GHz to 6 GHz <-153 dBm,
<-157 dBm (typ.)
6 GHz to 7.5 GHz <-148 dBm,
<-152 dBm (typ.)
RIGOL 6
Level Display
Logarithmic level axis 1 dB to 200 dB
Linear level axis 0 to reference level
Number of display points 601
Number of traces 3 + math trace
Trace detectors normal, positive-peak, negative-peak, sample, RMS, voltage average
quasi-peak (with EMI-DSA800 option)
Trace functions clear write, max hold, min hold, average, view, blank
Units of level axis dBm,dBmV, dBμV, nV, μV, mV, V, nW, μW, mW, W
Frequency Response
DSA815 DSA832 DSA875
Frequency response fc≥100 kHz, attenuation = 10 dB, relative to 50 MHz, 20ºC to 30 ºC
PA off
100 kHz to 1.5 GHz <0.7 dB <0.5 dB, <0.3 dB (typ.)
1.5 GHz to 3.2 GHz
3.2 GHz to 7.5 GHz <0.7 dB, <0.3 dB (typ.)
fc≥ 1 MHz, attenuation = 10 dB, relative to 50 MHz, 20ºC to 30 ºC
PA on
100 kHz to 1.5 GHz <1.0 dB <0.7 dB, <0.3 dB (typ.)
1.5 GHz to 3.2 GHz
3.2 GHz to 7.5 GHz <0.9 dB, <0.3 dB (typ.)
Input Attenuation Switching Uncertainty
DSA815 DSA832 DSA875
Setting range 0 to 30 dB, in 1 dB step
Switching uncertainty fc=50 MHz, relative to 10 dB, 20 ºC to 30 ºC
<0.5 dB <0.3 dB
7RIGOL
Absolute Amplitude Uncertainty
DSA815 DSA832 DSA875
Uncertainty
fc = 50 MHz, peak detector, preamplier off, attenuation = 10 dB, input signal level = -10 dBm,
20 ºC to 30 ºC
<0.4 dB <0.3 dB
RBW Switching Uncertainty
Uncertainty relative to 1 kHz RBW
<0.1 dB
Reference Level
Range -100 dBm to +20 dBm, in 1 dB step
Resolution log scale 0.01 dB
linear scale 4 digits
Preamplier
DSA815 (standard) PA-DSA832 (option) PA-DSA875 (option)
Gain
100 kHz to 1.5 GHz 20 dB (nom.) 17 dB (nom.) 17 dB (nom.)1.5 GHz to 3.2 GHz
3.2 GHz to 7.5 GHz
Level Measurement Uncertainty
DSA815 DSA832 DSA875
95% condence level, S/N>20 dB, RBW = VBW = 1 kHz,
preamplier off, attenuation = 10 dB, -50 dBm < input level ≤ 0 dBm, fc >10 MHz, 20 to 30
Level measurement uncertainty <1.5 dB (nom.) <0.8 dB (nom.)
RIGOL 8
RF Input VSWR
DSA815 DSA832 DSA875
attenuation ≥ 10 dB
VSWR
300 kHz to 1.5 GHz <1.5 (nom.) <1.5 (nom.) <1.5 (nom.)
1.5 GHz to 3.2 GHz
3.2 GHz to 7.5 GHz <1.8 (nom.)
Second Harmonic Intercept
DSA815 DSA832 DSA875
Second harmonic intercept (SHI) fc ≥ 50 MHz, input signal level = -20 dBm, attenuation = 10 dB
+40 dBm +45 dBm
Third-order Intercept
DSA815 DSA832 DSA875
Third-order intercept (TOI) fc 50 MHz, two -20 dBm tones at input mixer spaced by 200 kHz, attenuation = 10 dB
+10 dBm +11 dBm, +15 dBm (typ.)
1 dB Gain Compression
1 dB compression of input mixer
(P1dB)
fc ≥50 MHz, attenuation = 0 dB
>0 dBm
Distortion
9RIGOL
Spurious Responses
Spurious response
DSA815 DSA832 DSA875
input terminated 50 Ω, attenuation = 0 dB, 20ºC to 30ºC
<-88 dBm (typ.) <-90 dBm[1],
<-100 dBm (typ.)
Intermediate frequency <-60 dBc
System related sidebands
referenced to local oscillators, referenced to A/D conversion, referenced to subharmonic of rst
LO, referenced to harmonic of rst LO
<-60 dBc
Input related spurious mixer level = -30 dBm
<-60 dBc
Sweep
DSA815 DSA832 DSA875
Sweep time span≥100 Hz 10 ms to 1500s 1 ms to 1500 s 1 ms to 1500 s
zero span 20 μs to 1500 s 20 μs to 3200 s 20 μs to 7500 s
Sweep time
uncertainty
span≥100 Hz 5% (nom.)
zero span (sweep
time setting value
>1 ms)
5% (nom.)
Sweep mode continuous, single
Tracking Generator (Option)
TG Output
DSA815 DSA832 DSA875
Frequency range 100 kHz to 1.5 GHz 100 kHz to 3.2 GHz 100 kHz to 7.5 GHz
Output level range -20 dBm to 0 dBm -40 dBm to 0 dBm
Output level resolution 1 dB
Output atness relative to 50 MHz
±3 dB (nom.)
Sweep
NOTE: [1] Except the internal local oscillator (1820 MHz) and its harmonics.
RIGOL 10
Internal/ External Reference
Internal
reference
frequency 10 MHz
output level +3 dBm to +10 dBm, +8 dBm (typ.)
impedance 50 Ω (nom.)
connector BNC female
External
reference
frequency 10 MHz ±5 ppm
input level 0 dBm to +10 dBm
impedance 50 Ω (nom.)
connector BNC female
External Trigger Input
External trigger
input
impedance 1 kΩ (nom.)
connector BNC female
Communication Interface
USB host connector A plug
protocol version2.0
USB device connector B plug
protocol version2.0
LAN LXI core 2011
device 10/100Base, RJ-45
IEC/IEEE (GPIB) bus (USB-GPIB
option) IEEE488.2
Trigger Functions
Trigger
Trigger source free run, video, external
External trigger level 5 V TTL level
Input /Output
Front Panel Connectors
RF input impedance 50 Ω (nom.)
connector N female
Tracking
generator output
impedance 50 Ω (nom.)
connector N female
11 RIGOL
General Specications
Display
Type TFT LCD
Resolution 800 x 480 pixels
Size 8 inch
Colors 64 k
Printer Supported
Protocol PictBridge
Mass Memory
Mass memory ash disk (internal), USB storage device (not supplied)
Power Supply
Input voltage range, AC 100 V to 240 V (nom.)
AC supply frequency 45 Hz to 440 Hz
Power consumption 35 W (typ.),
max. 50 W with all options
Environmental
Temperature
operating
temperature range 0 to 50
Storage
temperature range -20 to 70
Humidity 0 to 30≤95% rel. humidity
30 to 40≤75% rel. humidity
Altitude operating height up to 3,000m
Electromagnetic Compatibility and Safety
EMC
in line with EN61326-1:2006
IEC 61000-4-2:2001 ±4.0 kV (contact discharge), ±4.0 kV (air discharge)
IEC 61000-4-3:2002
3 V/m (80 MHz to 1 GHz)
3 V/m (1.4 GHz to 2 GHz)
1 V/m (2.0 GHz to 2.7 GHz)
IEC 61000-4-4:2004 1 kV power lines
IEC 61000-4-5:2001
0.5 kV (phase to neutral)
0.5 kV (phase to PE)
1 kV (neutral to PE)
IEC 61000-4-6:2003 3 V,0.15-80 MHz
IEC 61000-4-
11:2004
voltage dip:
0% UT during half cycle
0% UT during 1 cycle
70% UT during 25 cycles
short interruption:0% UT during 250 cycles
Electrical safety in line with
UL 61010-1:2012, CAN/CSA-C22.2 No. 61010-1-12, EN 61010-1:2010
Dimensions
(W x H x D) 361.6 mm × 178.8 mm × 128 mm
(14.2 in × 7.0 in × 5.0 in)
Weight
DSA815 DSA832 DSA875
Standard 4.25 kg (9.4 lb) 4.55 kg (10.0 lb)
With tracking generator 5.15 kg (11.4 lb)
RIGOL 12
Warranty
Three-year warranty, excluding probes and accessories.
Description Order Number
Model
spectrum analyzer, 9 kHz to 1.5 GHz (with preamplier) DSA815
spectrum analyzer, 9 kHz to 3.2 GHz DSA832
spectrum analyzer, 9 kHz to 7.5 GHz DSA875
spectrum analyzer, 9 kHz to 1.5 GHz (with preamplier, with tracking generator,
factory installed) DSA815-TG
spectrum analyzer, 9 kHz to 3.2 GHz (with tracking generator, factory installed) DSA832-TG
spectrum analyzer, 9 kHz to 7.5 GHz (with tracking generator, factory installed) DSA875-TG
Standard
accessories
quick guide (hard copy) QGD07X00
CDROM (user’s guide, programming guide) -
power cable -
Options
preamplier, 100 kHz to 3.2 GHz (only for DSA832) PA-DSA832
preamplier, 100 kHz to 7.5 GHz (only for DSA875) PA-DSA875
EMI lter & quasi-peak detector EMI-DSA800
advanced measurement kit AMK-DSA800
VSWR measurement kit VSWR-DSA800
DSA PC software Ultra Spectrum
Optional
accessories
include: N-SMA cable, BNC-BNC cable, N-BNC adaptor, N-SMA adaptor, 75 Ω
to 50 Ω adaptor, 900 MHz/1.8 GHz antenna (2pcs), 2.4 GHz antenna (2pcs) DSA Utility Kit
include: N(F)-N(F) adaptor (1pcs), N(M)-N(M) adaptor (1pcs), N(M)-SMA(F)
adaptor (2pcs), N(M)-BNC(F) adaptor (2pcs), SMA(F)-SMA(F) adaptor (1pcs),
SMA(M)-SMA(M) adaptor (1pcs), BNC T type adaptor (1pcs), 50 Ω SMA load
(1pcs), 50 Ω BNC impedance adaptor (1pcs)
RF Adaptor Kit
include: 50 Ω to 75 Ω adaptor (2pcs) RF CATV Kit
include: 6 dB attenuator (1pcs), 10 dB attenuator (2pcs) RF Attenuator Kit
30 dB high power attenuator, max. power 100 W ATT03301H
N(M)-N(M) RF cable CB-NM-NM-75-L-12G
N(M)-SMA(M) RF cable CB-NM-SMAM-75-L-12G
RF demo kit (transmitter) TX1000
RF demo kit (receiver) RX1000
VSWR bridge with VSWR-DSA800, 1 MHz to 2 GHz VB1020
VSWR bridge with VSWR-DSA800, 800 MHz to 4 GHz VB1040
VSWR bridge with VSWR-DSA800, 2 GHz to 8 GHz VB1080
rack mount kit RM-DSA800
soft carrying bag BAG-G1
USB to GPIB interface converter for instrument USB-GPIB
Ordering Information
13 RIGOL
HEADQUARTER
RIGOL TECHNOLOGIES, INC.
No.156,Cai He Village,
Sha He Town,
Chang Ping District, Beijing,
102206 P.R.China
Tel:+86-10-80706688
Fax:+86-10-80705070
Electronic Measurement
Instrument service and support
email:EMD_support@rigol.com
Chemical Analysis Instrument
service and support email:service.
chem@rigol.com
EUROPE
RIGOL TECHNOLOGIES GmbH
Lindbergh str. 4
82178 Puchheim
Germany
Tel: 0049- 89/89418950
Email: info-europe@rigoltech.com
NORTH AMERICA
RIGOL TECHNOLOGIES,
USA INC.
10200 SW Allen Blvd, Suite C
Beaverton, OR 97005, USA
Toll free: 877-4-RIGOL-1
Of ce: (440) 232-4488
Fax: (216)-754-8107
Email: info@rigol.com
JAPAN
RIGOL TECHNOLOGIES JAPAN G.K.
Tonematsu Bldg. 5F, 2-33-8 Nihonbashi-
Ningyocho, Chuo-ku,
Tokyo 103-0013
Japan
Tel: +81-3-6264-9251
Fax: +81-3-6264-9252
Email: info-japan@rigol.com
RIGOL® is the registered trademark of RIGOL Technologies, Inc. Product information in this
document subject to update without notice. For the latest information about RIGOL's products,
applications and services, please contact local RIGOL of ce or access RIGOL of cial
website: www.rigol.com
November 2015