DSA800 Series Spectrum Analyzer All-Digital IF Technology Frequency Range from 9 kHz up to 7.5 GHz Min. -161 dBm Displayed Average Noise Level (Typ.) Min. < -98 dBc/Hz @ 10 kHz Offset Phase Noise Level Measurement Uncertainty < 0.8 dB 10 Hz Minimum Resolution Bandwidth (DSA832/875) Up to 7.5 GHz Tracking Generator (DSA8XX-TG) Optional Preamplifier (DSA832/875) Advanced Measurement Functions (Opt.) EMI Filter & Quasi-Peak Detector Kit (Opt.) VSWR Measurement Kit (Opt.) PC Software (Opt.) Optional RF TX/RX Training Kit Optional RF Accessories (Cable, Adaptor, Attenuator, Bridge ...) Complete Connectivity: LAN (LXI), USB Host & Device, GPIB (Opt.) 8 Inch WVGA (800x480) Display Compact Size, Light Weight Design RIGOL TECHNOLOGIES,INC. DSA800 Series Spectrum Analyzer Advanced Measurement Keys Basic Keys USB Port TG Output Marker Keys RF Input Product Dimensions: Width X Height X Depth = 361.6 mm x 178.8 mm x 128 mm Benefits of Rigol's all digital IF design The ability to measure smaller signals: on the basis of this technology, the IF filter enables smaller bandwidth settings, which greatly reduce the displayed average noise level. The ability to distinguish between small signals by frequency: using the IF filter with the smallest bandwidth setting, it is possible to make out signals with a frequency difference of only 10 Hz. High precision amplitude readings: this technology almost eliminates the errors generated by filter switching, reference level uncertainty, scale distortion, as well as errors produced in the process of switching between logarithmic and linear display of amplitude when using a traditional analog IF design. Higher reliability: compared with traditional analog designs, the digital IF greatly reduces the complexity of the hardware, the system instability caused by channel aging, and the temperature sensitivity that can contribute to parts failure. High measurement speed: the use of digital IF technology improves the bandwidth precision and selectivity of the filter, minimizing the scanning time and improving the speed of the measurement. 1 RIGOL Features and Benefits Distinguish the two nearby signals clearly with the 10 Hz RBW (DSA832/875) Compare the spectrums with different color trace Readout the spectrum peak values with the peak table function Measure lower level signal with the preamplifier turn on Phase noise < -98 dBc/Hz @10 kHz offset (DSA832/875) EMI kit (EMI filter & Quasi-peak & Pass/Fail) The GUI to control the RF demo kit (Transmitter) directly VSWR measurement RIGOL 2 RIGOL Spectrum Analyzer Option and Accessory Harmonic Distoration TOI Occupied Bandwidth Channel Power Time Domain Power Emission Bandwidth Carrier to Noise Ratio Adjacent Channel Power Pass/Fail Advanced Measurement Kit AMK-DSA800 Rack Mount Kit ( RM-DSA800 ) VSWR Bridge ( VB1020/VB1040/VB1080 ) RF Demo Kit ( TX1000 ) RF Demo Kit ( RX1000 ) RF CATV Kit DSA Utility Kit RF Adaptor Kit RF Attenuator Kit RF Cable Kit High Power Attenuator ( ATT03301H ) DSA PC Software ( Ultra Spectrum ) ( CB-NM-NM-75-L-12G ) ( CB-NM-SMAM-75-L-12G ) Soft Carrying Bag ( BAG-G1 ) 3 RIGOL USB to GPIB Converter ( USB-GPIB ) Specifications Specifications are valid under the following conditions: the instrument is within the calibration period, is stored for at least two hours at 0 to 50 temperature, and is warmed up for 40 minutes. Unless otherwise noted, the specifications in this manual include the measurement uncertainty. Typical (typ.): characteristic performance, which 80 percent of the measurement results will meet at room temperature (approximately 25 ). This data is not warranted and does not include the measurement uncertainty. Nominal (nom.): the expected mean or average performance or a designed attribute (such as the 50 connector). This data is not warranted and is measured at room temperature (approximately 25 ). Measured (meas.): an attribute measured during the design phase which can be compared to the expected performance, such as the amplitude drift variation with time. This data is not warranted and is measured at room temperature (approximately 25 ). NOTE: All charts in this manual are the measurement results of multiple instruments at room temperature unless otherwise noted. The specifications (except the TG specifications) listed in this manual are those when the tracking generator is off. Frequency Frequency Frequency range Frequency resolution DSA815 9 kHz to 1.5 GHz 1 Hz DSA832 9 kHz to 3.2 GHz DSA875 9 kHz to 7.5 GHz Internal Reference Frequency Reference frequency Accuracy Initial calibration accuracy Temperature stability Aging rate Frequency Readout Accuracy Marker resolution Marker uncertainty DSA815 DSA832 DSA875 10 MHz [(time since last adjustment x aging rate) + temperature stability + calibration accuracy] <1 ppm 0 to 50 , reference to 25 <2 ppm <0.5 ppm <2 ppm/year <1 ppm/year span/ (number of sweep points - 1) (frequency indication x frequency reference uncertainty + 1% x span + 10% x resolution bandwidth + marker resolution) Frequency Counter Resolution Uncertainty 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz (frequency indication x reference frequency accuracy + counter resolution) Frequency Span Range Uncertainty 0 Hz, 100 Hz to maximum frequency of instrument span/ (number of sweep points - 1) SSB Phase Noise 20 to 30 , fc=1 GHz Carrier offset 10 kHz 100 kHz DSA815 <-80 dBc/Hz <-100 dBc/Hz (typ.) DSA832 <-98 dBc/Hz <-100 dBc/Hz (typ.) DSA875 RIGOL 4 Residual FM 20 to 30 , RBW = VBW = 1 kHz DSA815 <50 Hz (nom.) Residual FM DSA832 <20 Hz (nom.) DSA875 DSA832 DSA875 Bandwidths Resolution bandwidth (-3 dB) RBW uncertainty Resolution filter shape factor (60 dB: 3 dB) Video bandwidth (-3 dB) Resolution bandwidth (-6 dB) (EMI-DSA800 option) Set "Auto SWT" to "Accy" DSA815 100 Hz to 1 MHz, in 1-3-10 sequence <5% (nom.) 10 Hz to 1 MHz, in 1-3-10 sequence <5 (nom.) 1 Hz to 3 MHz, in 1-3-10 sequence 200 Hz, 9 kHz, 120 kHz Amplitude Measurement Range fc 10 MHz DANL to +20 dBm Range Maximum Input Level DC voltage CW RF power Max. damage level[1] 50 V attenuation = 30 dB +20 dBm (100 mW) +30 dBm (1 W) NOTE: [1] When fc 10 MHz, input level > +25 dBm and PA is Off, the protection switch will be on. Displayed Average Noise Level (DANL) Frequency PA off PA on 5 RIGOL 100 kHz to 1 MHz 1 MHz to 1.5 GHz 100 kHz to 1 MHz 1 MHz to 1.5 GHz DSA815 attenuation = 0 dB, RBW = VBW = 100 Hz, sample detector, trace average 50, tracking generator off, 20 to 30 , input impendence = 50 <-90 dBm, <-110 dBm (typ.) <-110 dBm + 6 x (f/1GHz) dB, <-115 dBm (typ.) <-110 dBm, <- 130 dBm (typ.) <-130 dBm + 6 x (f/1GHz) dB, <-135 dBm (typ.) Displayed Average Noise Level (DANL) Frequency PA off PA on 9 kHz to 100 kHz 100 kHz to 5 MHz 5 MHz to 3.2 GHz 3.2 GHz to 6 GHz 6 GHz to 7.5 GHz 100 kHz to 1 MHz 1 MHz to 5 MHz 5 MHz to 3.2 GHz 3.2 GHz to 6 GHz 6 GHz to 7.5 GHz DSA832 DSA875 attenuation = 0 dB, RBW = VBW = 10 Hz, sample detector, trace average 50, tracking generator off, 20 to 30 , input impendence = 50 <-110 dBm (typ.) <-110 dBm (typ.) <-125 dBm, <-128 dBm (typ.) <-125 dBm, <-128 dBm (typ.) <-130 dBm, <-134 dBm (typ.) <-130 dBm, <-134 dBm (typ.) <-126 dBm, <-130 dBm (typ.) <-121 dBm, <-125 dBm (typ.) <-142 dBm (typ.) <-142 dBm (typ.) <-142 dBm, <-145 dBm (typ.) <-142 dBm, <-145 dBm (typ.) <-147 dBm, <-151 dBm (typ.) <-147 dBm, <-151 dBm (typ.) <-143 dBm, <-147 dBm (typ.) <-138 dBm, <-142 dBm (typ.) Displayed Average Noise Level (DANL) (Normalized to 1 Hz) DSA815 Frequency 9 kHz to 100 kHz PA off DSA832 100 kHz to 1 MHz <-110 dBm, <-130 dBm (typ.) 1 MHz to 5 MHz 5 MHz to 1.5 GHz 1.5 GHz to 3.2 GHz <-130 dBm + 6 x (f/1GHz) dB, <-135 dBm (typ.) <-120 dBm (typ.) <-120 dBm (typ.) <-135 dBm, <-138 dBm (typ.) <-135 dBm, <-138 dBm (typ.) <-140 dBm, <-144 dBm (typ.) <-140 dBm, <-144 dBm (typ.) <-136 dBm, <-140 dBm (typ.) <-131 dBm, <-135 dBm (typ.) 3.2 GHz to 6 GHz 6 GHz to 7.5 GHz PA on DSA875 attenuation = 0 dB, RBW = VBW = 100 Hz, sample detector, trace average 50, tracking generator off, normalized to 1Hz, 20 to 30 , input impendence = 50 100 kHz to 1 MHz <-130 dBm, <-150 dBm (typ.) 1 MHz to 5 MHz <-150 dBm + 6 x (f/1GHz) dB, <-155 dBm (typ.) 5 MHz to 1.5 GHz 1.5 GHz to 3.2 GHz 3.2 GHz to 6 GHz 6 GHz to 7.5 GHz <-152 dBm (typ.) <-152 dBm (typ.) <-152 dBm, <-155 dBm (typ.) <-152 dBm, <-155 dBm (typ.) <-157 dBm, <-161 dBm (typ.) <-157 dBm, <-161 dBm (typ.) <-153 dBm, <-157 dBm (typ.) <-148 dBm, <-152 dBm (typ.) RIGOL 6 Level Display Logarithmic level axis Linear level axis Number of display points Number of traces Trace detectors Trace functions Units of level axis 1 dB to 200 dB 0 to reference level 601 3 + math trace normal, positive-peak, negative-peak, sample, RMS, voltage average quasi-peak (with EMI-DSA800 option) clear write, max hold, min hold, average, view, blank dBm,dBmV, dBV, nV, V, mV, V, nW, W, mW, W Frequency Response Frequency response 100 kHz to 1.5 GHz PA off 1.5 GHz to 3.2 GHz 3.2 GHz to 7.5 GHz PA on 100 kHz to 1.5 GHz 1.5 GHz to 3.2 GHz 3.2 GHz to 7.5 GHz DSA815 DSA832 fc100 kHz, attenuation = 10 dB, relative to 50 MHz, 20C to 30 C <0.7 dB <0.5 dB, <0.3 dB (typ.) <0.7 dB, <0.3 dB (typ.) fc 1 MHz, attenuation = 10 dB, relative to 50 MHz, 20C to 30 C <1.0 dB <0.7 dB, <0.3 dB (typ.) <0.9 dB, <0.3 dB (typ.) Input Attenuation Switching Uncertainty DSA815 DSA832 Setting range 0 to 30 dB, in 1 dB step fc=50 MHz, relative to 10 dB, 20 C to 30 C Switching uncertainty <0.5 dB <0.3 dB 7 RIGOL DSA875 DSA875 Absolute Amplitude Uncertainty DSA815 DSA875 DSA832 fc = 50 MHz, peak detector, preamplifier off, attenuation = 10 dB, input signal level = -10 dBm, 20 C to 30 C <0.4 dB <0.3 dB Uncertainty RBW Switching Uncertainty relative to 1 kHz RBW <0.1 dB Uncertainty Reference Level Range Resolution log scale linear scale -100 dBm to +20 dBm, in 1 dB step 0.01 dB 4 digits Preamplifier Gain 100 kHz to 1.5 GHz 1.5 GHz to 3.2 GHz 3.2 GHz to 7.5 GHz DSA815 (standard) 20 dB (nom.) PA-DSA832 (option) 17 dB (nom.) PA-DSA875 (option) 17 dB (nom.) Level Measurement Uncertainty Level measurement uncertainty DSA815 DSA875 DSA832 95% confidence level, S/N>20 dB, RBW = VBW = 1 kHz, preamplifier off, attenuation = 10 dB, -50 dBm < input level 0 dBm, fc >10 MHz, 20 to 30 <1.5 dB (nom.) <0.8 dB (nom.) RIGOL 8 RF Input VSWR VSWR 300 kHz to 1.5 GHz 1.5 GHz to 3.2 GHz 3.2 GHz to 7.5 GHz DSA815 attenuation 10 dB <1.5 (nom.) DSA832 DSA875 <1.5 (nom.) <1.5 (nom.) <1.8 (nom.) Distortion Second Harmonic Intercept Second harmonic intercept (SHI) DSA815 DSA832 fc 50 MHz, input signal level = -20 dBm, attenuation = 10 dB +40 dBm +45 dBm DSA875 Third-order Intercept Third-order intercept (TOI) 1 dB Gain Compression 1 dB compression of input mixer (P1dB) 9 RIGOL DSA815 DSA832 DSA875 fc 50 MHz, two -20 dBm tones at input mixer spaced by 200 kHz, attenuation = 10 dB +10 dBm +11 dBm, +15 dBm (typ.) fc 50 MHz, attenuation = 0 dB >0 dBm Spurious Responses Spurious response Intermediate frequency System related sidebands Input related spurious DSA815 DSA832 DSA875 input terminated 50 , attenuation = 0 dB, 20C to 30C <-90 dBm[1], <-88 dBm (typ.) <-100 dBm (typ.) <-60 dBc referenced to local oscillators, referenced to A/D conversion, referenced to subharmonic of first LO, referenced to harmonic of first LO <-60 dBc mixer level = -30 dBm <-60 dBc NOTE: [1] Except the internal local oscillator (1820 MHz) and its harmonics. Sweep Sweep Sweep time Sweep time uncertainty span100 Hz zero span span100 Hz zero span (sweep time setting value >1 ms) Sweep mode DSA815 10 ms to 1500s 20 s to 1500 s 5% (nom.) DSA832 1 ms to 1500 s 20 s to 3200 s DSA875 1 ms to 1500 s 20 s to 7500 s DSA832 100 kHz to 3.2 GHz -40 dBm to 0 dBm DSA875 100 kHz to 7.5 GHz 5% (nom.) continuous, single Tracking Generator (Option) TG Output Frequency range Output level range Output level resolution Output flatness DSA815 100 kHz to 1.5 GHz -20 dBm to 0 dBm 1 dB relative to 50 MHz 3 dB (nom.) RIGOL 10 Trigger Functions Trigger Trigger source External trigger level free run, video, external 5 V TTL level Input /Output Front Panel Connectors impedance RF input connector impedance Tracking generator output connector 50 (nom.) N female 50 (nom.) N female Internal/ External Reference frequency output level Internal reference impedance connector frequency input level External reference impedance connector 10 MHz +3 dBm to +10 dBm, +8 dBm (typ.) 50 (nom.) BNC female 10 MHz 5 ppm 0 dBm to +10 dBm 50 (nom.) BNC female External Trigger Input External trigger impedance input connector 1 k (nom.) BNC female Communication Interface connector USB host protocol connector USB device protocol LXI core 2011 LAN device IEC/IEEE (GPIB) bus (USB-GPIB option) 11 RIGOL A plug version2.0 B plug version2.0 10/100Base, RJ-45 IEEE488.2 General Specifications Display Type Resolution Size Colors TFT LCD 800 x 480 pixels 8 inch 64 k Printer Supported Protocol PictBridge Mass Memory Mass memory flash disk (internal), USB storage device (not supplied) Power Supply Input voltage range, AC AC supply frequency Power consumption 100 V to 240 V (nom.) 45 Hz to 440 Hz 35 W (typ.), max. 50 W with all options Environmental Temperature Humidity Altitude operating temperature range Storage temperature range 0 to 30 30 to 40 operating height 0 to 50 -20 to 70 95% rel. humidity 75% rel. humidity up to 3,000m Electromagnetic Compatibility and Safety in line with EN61326-1:2006 IEC 61000-4-2:2001 4.0 kV (contact discharge), 4.0 kV (air discharge) 3 V/m (80 MHz to 1 GHz) IEC 61000-4-3:2002 3 V/m (1.4 GHz to 2 GHz) 1 V/m (2.0 GHz to 2.7 GHz) IEC 61000-4-4:2004 1 kV power lines 0.5 kV (phase to neutral) EMC IEC 61000-4-5:2001 0.5 kV (phase to PE) 1 kV (neutral to PE) IEC 61000-4-6:2003 3 V,0.15-80 MHz voltage dip: 0% UT during half cycle IEC 61000-40% UT during 1 cycle 11:2004 70% UT during 25 cycles short interruption:0% UT during 250 cycles in line with Electrical safety UL 61010-1:2012, CAN/CSA-C22.2 No. 61010-1-12, EN 61010-1:2010 Dimensions (W x H x D) 361.6 mm x 178.8 mm x 128 mm (14.2 in x 7.0 in x 5.0 in) Weight DSA815 Standard With tracking generator 4.25 kg (9.4 lb) DSA832 4.55 kg (10.0 lb) 5.15 kg (11.4 lb) DSA875 RIGOL 12 Ordering Information Model Standard accessories Options Optional accessories Warranty Description spectrum analyzer, 9 kHz to 1.5 GHz (with preamplifier) spectrum analyzer, 9 kHz to 3.2 GHz spectrum analyzer, 9 kHz to 7.5 GHz spectrum analyzer, 9 kHz to 1.5 GHz (with preamplifier, with tracking generator, factory installed) spectrum analyzer, 9 kHz to 3.2 GHz (with tracking generator, factory installed) spectrum analyzer, 9 kHz to 7.5 GHz (with tracking generator, factory installed) quick guide (hard copy) CDROM (user's guide, programming guide) power cable preamplifier, 100 kHz to 3.2 GHz (only for DSA832) preamplifier, 100 kHz to 7.5 GHz (only for DSA875) EMI filter & quasi-peak detector advanced measurement kit VSWR measurement kit DSA PC software DSA815-TG DSA832-TG DSA875-TG QGD07X00 PA-DSA832 PA-DSA875 EMI-DSA800 AMK-DSA800 VSWR-DSA800 Ultra Spectrum include: N-SMA cable, BNC-BNC cable, N-BNC adaptor, N-SMA adaptor, 75 to 50 adaptor, 900 MHz/1.8 GHz antenna (2pcs), 2.4 GHz antenna (2pcs) DSA Utility Kit include: N(F)-N(F) adaptor (1pcs), N(M)-N(M) adaptor (1pcs), N(M)-SMA(F) adaptor (2pcs), N(M)-BNC(F) adaptor (2pcs), SMA(F)-SMA(F) adaptor (1pcs), SMA(M)-SMA(M) adaptor (1pcs), BNC T type adaptor (1pcs), 50 SMA load (1pcs), 50 BNC impedance adaptor (1pcs) RF Adaptor Kit include: 50 to 75 adaptor (2pcs) include: 6 dB attenuator (1pcs), 10 dB attenuator (2pcs) 30 dB high power attenuator, max. power 100 W N(M)-N(M) RF cable N(M)-SMA(M) RF cable RF demo kit (transmitter) RF demo kit (receiver) VSWR bridge with VSWR-DSA800, 1 MHz to 2 GHz VSWR bridge with VSWR-DSA800, 800 MHz to 4 GHz VSWR bridge with VSWR-DSA800, 2 GHz to 8 GHz rack mount kit soft carrying bag USB to GPIB interface converter for instrument RF CATV Kit RF Attenuator Kit ATT03301H CB-NM-NM-75-L-12G CB-NM-SMAM-75-L-12G TX1000 RX1000 VB1020 VB1040 VB1080 RM-DSA800 BAG-G1 USB-GPIB Three-year warranty, excluding probes and accessories. 13 RIGOL Order Number DSA815 DSA832 DSA875 HEADQUARTER EUROPE NORTH AMERICA JAPAN RIGOL TECHNOLOGIES, INC. No.156,Cai He Village, Sha He Town, Chang Ping District, Beijing, 102206 P.R.China Tel:+86-10-80706688 Fax:+86-10-80705070 Electronic Measurement Instrument service and support email:EMD_support@rigol.com Chemical Analysis Instrument service and support email:service. chem@rigol.com RIGOL TECHNOLOGIES GmbH Lindbergh str. 4 82178 Puchheim Germany Tel: 0049- 89/89418950 Email: info-europe@rigoltech.com RIGOL TECHNOLOGIES, USA INC. 10200 SW Allen Blvd, Suite C Beaverton, OR 97005, USA Toll free: 877-4-RIGOL-1 Office: (440) 232-4488 Fax: (216)-754-8107 Email: info@rigol.com RIGOL TECHNOLOGIES JAPAN G.K. Tonematsu Bldg. 5F, 2-33-8 NihonbashiNingyocho, Chuo-ku, Tokyo 103-0013 Japan Tel: +81-3-6264-9251 Fax: +81-3-6264-9252 Email: info-japan@rigol.com RIGOL(R) is the registered trademark of RIGOL Technologies, Inc. Product information in this document subject to update without notice. For the latest information about RIGOL's products, applications and services, please contact local RIGOL office or access RIGOL official website: www.rigol.com November 2015