Specifications
Input Voltage:
Typical: 115 to 239VAC, ±10%, 50/60Hz
Minimum: 85VAC, 120VDC
Maximum: 265VAC, 300VDC
Input Current:
(average values for reference only)
@115VAC: 250mArms, ±20%
@230VAC: 150mArms, ±20%
@125VDC: 125mA, ±20%
@250VDC: 65mA, ±20%
Output Voltage:
24VDC
Maximum Output Current:
0.5A
Input Protection:
Fuse: 2A slowblow (internal)
Inrush Current: Thermistor
Over Voltage: Varistor
Switching Frequency:
100kHz
Efficiency @ Maximum Load:
79%
Maximum Ripple:
0.1%
Load Regulation:
0.2% (10% to 100% Load)
Line Regulation:
0.2% (85VAC to 265VAC In)
Dimensions
Dimensions are in millimeters (inches)
Ordering Information
Specify:
1. Model:
WV905-0000
Overload Protection:
Over current shutdown with automatic restart
plus thermal shutdown
Maximum Load Capacitance on Output:
5.000uF
Hold Time:
(full output current after loss of input)
@115VAC: 14ms
@230VAC: 70ms
Isolation:
Input to Output: 3kV
Input/Output to Rail: 4kV
Input to Ground: 1.5kV
Output to Ground: 500V
Wire Size:
26-12AWG (0.1 to 4.0mm2)
Operating Temperature:
-20°C to +50°C (-4°F to 122°F)
Storage Temperature:
-40°C to +85°C (-40°F to 185°F)
Operating Humidity:
20% to 85% RHNC @ 45°C
Storage Humidity:
20% to 90% RHNC @ 60°C for 24 hours
Size:
DIN rail case – refer to Dimensions drawing
Agency Approvals:
UL recognized per standard UL508
(File No.E99775)
CE Conformance per EMC directive 89/336/EEC and Low Voltage
73/23/EEC (Input < 75VDC, only).
RoHS Compliant
Note that detailed installation instructions are available on our website.
Eurotherm, Inc
741-F Miller Drive
Leesburg, VA 20175-8993
703-443-0000
info@eurotherm.com or www.eurotherm.com/actionio
Factory Assistance
For additional information on calibration, operation and installation
contact our Technical Services Group:
703-669-1318
721-0846-00-D 02/09 Copyright© Eurotherm, Inc 2009
Action Instruments Barber-Colman Chessell Continental Eurotherm
actionsupport@eurotherm.com
Printed on recycled pape