CY7C271
CY7C274
Document #: 38-04008 Rev. *B Page 2 of 11
Maximum Ratings[1]
(Above which the useful life may be impaired. For user guide-
lines, not tes ted .)
Storage Temperature .....................................−65°C to +150°C
Ambient Temperature with
Power Applied..................................................−55°C to +125°C
Supply Voltage to Ground Potential.................−0.5V to +7.0V
DC Voltage Applied to Outputs
in High Z Stat e .....................................................−0.5V to +7.0V
DC Input Voltage.................................................−3.0V to +7.0V
DC Program Voltage ....................................................13.0V
Static Discha rge Voltage..... ................. ...... ................> 200 1V
(per MIL-STD-883, Method 3015)
Latch-Up Current.....................................................>200 mA
UV Exposure ................................................7258 Wsec/cm2
Selection Guide
7C274-30 7C271-35
7C274-35 7C271-45
7C274-45 7C271-55 Unit
Maxi mu m A cc es s Time 30 35 45 55 ns
Maxi mu m Op er at ing
Current Com’l 120 120 120 120 mA
Military 130 130 130 mA
Standby Current Com’l 30 30 30 30 mA
Military 40 40 40 mA
Operating Range
Range Ambient
Temperature VCC
Commercial 0°C to +70°C 5V ±10%
Military[2] −55°C to +125°C 5V ±10%
Electrical Characteristi cs Ov er the Operating Ran ge [3]
7C271- 35, 45, 55
7C274-30, 35, 45,
Parameter Description Test Conditions Min. Max. Unit
VOH Output HIGH Voltage VCC = Min., IOH = −2.0 mA 2.4 V
VOL Output LOW Voltage VCC = Min., IOL = 8.0 mA[4] 0.4 V
VIH Input HIGH Level Guaranteed Input Logical HIGH Voltage for All
Inputs 2.0 VCC V
VIL Input LOW Level Guaranteed Input Logical LOW V oltage for All
Inputs 0.8 V
IIX Input Current GND < VIN < VCC −10 +10 µA
IOZ Output Leakage Current GND < VOUT < VCC, Output Disabled −40 +40 µA
IOS Output Short Circuit Current[5] VCC = Max., VOUT = GND −20 −90 mA
ICC Power Supply Current VCC = Max., VIN = 2.0V,
IOUT = 0 mA, CE=VIL Commercial 120 mA
Military 130
ISB Standby Supply Current VCC = Max., CE = VIH,
IOUT = 0 mA Commercial 30 mA
Military 40
VPP Programmi ng Supp ly Voltage 12 13 V
IPP Programmi ng Supp ly Curre nt 50 mA
VIHP Input HIGH Prog ramming
Voltage 3.0 V
VILP Input LOW Programming
Voltage 0.4 V
Notes:
1. The voltage on any input or I/O pin cannot exceed the power pin during power-up.
2. TA is the “instant on” case temperature.
3. See the last page of this specification for Group A subgroup testing information.
4. 6.0 mA military
5. For test purposes, not more than one output at a time should be shorted. Short circuit test duration should not exceed 30 seconds.