New Product DIN Track Terminal Blocks with Screw Terminals XW5T Global-standard DIN Terminal Blocks for Control Panels * Wires held with screws. * Compatible with a wide range of wire sizes with a nominal cross section from 2.5 to 150 mm2. * Terminal Blocks with Fuses and Disconnect Terminal Blocks are available. Refer to your OMRON website for the most recent information on models that are certified for standards. Refer to Safety Precautions on page 20. Model Number Legend Feed Through Terminal Blocks Grounding Terminal Blocks XW5T - S@-@-@@ XW5G - S@-@-@ (1) (2) (3) (4) (1) (2) (3) (1) Nominal Cross Section 2.5: 2.5mm2 4.0: 4.0mm2 6.0: 6.0mm2 10: 10mm2 16: 16mm2 35: 35mm2 70: 70mm2 150: 150mm2 (2) Wiring 1.1:1:1 1.2:1:2 (3) Number of Tiers 1: 1 tier 2: 2 tiers (4) Color Blank: Dark gray BL: Blue V: Black (Vertical Connection) 2.2:2:2 1 XW5T Ordering Information Classification Product Type Standard terminals Feed Through Terminal blocks Multi tiers terminal Multi conductor terminals Standard terminals Grounding Terminal blocks Coler Flammability Insulating Rating according material to UL94 Model Pack Weight (pcs.) (gram) 2.5 1 2 Dark gray PA V0 XW5T-S2.5-1.1-1 100 8 2.5 1 2 Blue PA V0 XW5T-S2.5-1.1-1BL 100 8 4.0 1 2 Dark gray PA V0 XW5T-S4.0-1.1-1 100 9 4.0 1 2 Blue PA V0 XW5T-S4.0-1.1-1BL 100 9 6.0 1 2 Dark gray PA V0 XW5T-S6.0-1.1-1 100 14 14 6.0 1 2 Blue PA V0 XW5T-S6.0-1.1-1BL 100 10.0 1 2 Dark gray PA V0 XW5T-S10-1.1-1 50 17 10.0 1 2 Blue PA V0 XW5T-S10-1.1-1BL 50 17 16.0 1 2 Dark gray PA V0 XW5T-S16-1.1-1 50 37 16.0 1 2 Blue PA V0 XW5T-S16-1.1-1BL 50 37 35.0 1 2 Dark gray PA V0 XW5T-S35-1.1-1 20 74 35.0 1 2 Blue PA V0 XW5T-S35-1.1-1BL 20 74 70.0 1 2 Dark gray PA V0 XW5T-S70-1.1-1 20 177 70.0 1 2 Blue PA V0 XW5T-S70-1.1-1BL 20 177 150.0 1 2 Dark gray PA V0 XW5T-S150-1.1-1 10 281 150.0 1 2 Blue PA V0 XW5T-S150-1.1-1BL 10 282 13 2.5 2 2 Dark gray PA V0 XW5T-S2.5-1.1-2 100 2.5 2 2 Black PA V0 XW5T-S2.5-1.1-2V 100 15 4.0 2 2 Dark gray PA V0 XW5T-S4.0-1.1-2 100 19 Black 20 4.0 2 2 4.0 1 3 4.0 1 4 4.0 1 3 4.0 1 4 2.5 1 2 PA V0 XW5G-S2.5-1.1-1 100 10 4.0 1 2 PA V0 XW5G-S4.0-1.1-1 100 12 Dark gray Blue PA V0 XW5T-S4.0-1.1-2V 100 PA V0 XW5T-S4.0-1.2-1 100 13 PA V0 XW5T-S4.0-2.2-1 100 17 PA V0 XW5T-S4.0-1.2-1BL 100 13 PA V0 XW5T-S4.0-2.2-1BL 100 17 6.0 1 2 PA V0 XW5G-S6.0-1.1-1 100 20 10.0 1 2 PA V0 XW5G-S10-1.1-1 50 23 16.0 1 2 PA V0 XW5G-S16-1.1-1 50 47 35.0 1 2 PA V0 XW5G-S35-1.1-1 20 123 Green/ yellow 70.0 1 2 PA V0 XW5G-S70-1.1-1 20 240 Multi tiers terminal 4.0 2 2 PA V0 XW5G-S4.0-1.1-2 100 23 Multi conductor terminals 4.0 1 3 PA V0 XW5G-S4.0-1.2-1 100 16 4.0 1 4 PA V0 XW5G-S4.0-2.2-1 100 20 4.0 1 2 PA V0 XW5T-S4.0-FU5 50 19 4.0 1 2 PA V0 XW5T-S4.0-FU6 50 22 4.0 1 2 PA V0 XW5T-S4.0-KD 100 12 Fuse terminal Special terminals Knife edge disconnect block 2 Number of Nominal Cross Number cramp position Section (mm2) of levels per level Dark gray XW5T Accessories Short Bars Separator Plates For XW5-S2.5- No. of poles Applicable Terminal Blocks Color 2 Model Pack (pcs.) XW5S-S2.5-2 10 XW5S-S2.5-3 10 XW5S-S2.5-4 10 5 XW5S-S2.5-5 10 10 XW5S-S2.5-10 20 3 Yellow (YL) 4 For XW5-S4.0- No. of poles Yellow (YL) Labels Applicable Terminal Blocks 25 11-20 XW5Z-S2.5LB-11-20 25 21-30 XW5Z-S2.5LB-21-30 25 31-40 XW5Z-S2.5LB-31-40 25 41-50 XW5Z-S2.5LB-41-50 25 51-60 XW5Z-S2.5LB-51-60 25 61-70 XW5Z-S2.5LB-61-70 25 71-80 XW5Z-S2.5LB-71-80 25 Pack (pcs.) 81-90 XW5Z-S2.5LB-81-90 25 91-100 XW5Z-S2.5LB-91-100 25 XW5S-S6.0-2 10 1-100 XW5Z-S2.5LB-1-100 1* 10 10 5 XW5S-S4.0-5 10 10 XW5S-S4.0-10 20 XW5-S2.5- For XW5-S6.0- Color 3 Pack (pcs.) 25 10 2 Model XW5Z-S2.5LB-1-10 Pack (pcs.) XW5S-S4.0-4 No. of poles Marking XW5Z-S2.5LB XW5S-S4.0-3 4 10 1-10 Model XW5S-S4.0-2 3 XW5Z-S2.5PT Pack (pcs.) None Color 2 XW5-S2.5-1.1- XW5-S4.0-1.1- XW5-S6.0-1.1- XW5-S10-1.1- Model Model XW5S-S6.0-3 10 None XW5Z-S4.0LB 25 4 XW5S-S6.0-4 10 1-10 XW5Z-S4.0LB-1-10 25 5 XW5S-S6.0-5 10 11-20 XW5Z-S4.0LB-11-20 25 21-30 XW5Z-S4.0LB-21-30 25 31-40 XW5Z-S4.0LB-31-40 25 41-50 XW5Z-S4.0LB-41-50 25 51-60 XW5Z-S4.0LB-51-60 25 61-70 XW5Z-S4.0LB-61-70 25 71-80 XW5Z-S4.0LB-71-80 25 81-90 XW5Z-S4.0LB-81-90 25 91-100 XW5Z-S4.0LB-91-100 25 1-100 XW5Z-S4.0LB-1-100 1* Cross Connector with Screw None XW5Z-S6.0LB 25 For XW5-S2.5-1.1-2 1-10 XW5Z-S6.0LB-1-10 25 Pack (pcs.) 11-20 XW5Z-S6.0LB-11-20 25 21-30 XW5Z-S6.0LB-21-30 25 Yellow (YL) For XW5-S10- No. of poles 2 Color Yellow (YL) Model XW5S-S10-2 Pack (pcs.) XW5-S4.0- 10 For XW5-S16- No. of poles 2 Color Yellow (YL) No. of poles Color Model XW5S-S16-2 Model Pack (pcs.) 10 2 XW5S-S2.5-2N 10 31-40 XW5Z-S6.0LB-31-40 25 3 XW5S-S2.5-3N 10 41-50 XW5Z-S6.0LB-41-50 25 XW5S-S2.5-4N 10 51-60 XW5Z-S6.0LB-51-60 25 XW5S-S2.5-5N 10 61-70 XW5Z-S6.0LB-61-70 25 10 71-80 XW5Z-S6.0LB-71-80 25 81-90 XW5Z-S6.0LB-81-90 25 91-100 XW5Z-S6.0LB-91-100 25 1-100 XW5Z-S6.0LB-1-100 1* Yellow (YL) 4 5 10 XW5S-S2.5-10N End Covers Applicable Terminal Blocks Model Pack (pcs.) XW5-S6.0- * Box including 250 pcs. XW5-S2.5-1.1- XW5-S4.0-1.1- XW5-S6.0-1.1- XW5-S10-1.1- XW5E-S2.5 10 XW5T-S16-1.1- XW5E-S16 10 XW5T-S4.0-KD XW5-S4.0-1.2-1 XW5E-S4.0-1.2-1 10 XW5-S4.0-2.2-1 XW5E-S4.0-2.2-1 10 XW5-S4.0-1.1-2 XW5E-S4.0-1.1-2 10 XW5T-S2.5-1.1-2 XW5E-S2.5N 10 3 XW5T Ratings and Specifications Feed Through Terminal Blocks Model XW5T-S2.5-1.1-1(BL) XW5T-S4.0-1.1-1(BL) 1 tier, 1:1 XW5T-S6.0-1.1-1(BL) 1 tier, 1:1 XW5T-S10-1.1-1(BL) 1 tier, 1:1 1 tier, 1:1 Applicable wire sizes Appearance and internal wiring NOMINAL CROSS SECTION 2.5 mm2 4.0 mm2 6.0 mm2 10 mm2 Minimum conductor cross section solid 0.14 mm2 0.14 mm2 0.2 mm2 0.5 mm2 Maximum conductor cross section solid 4.0 mm2 6.0 mm2 10 mm2 16 mm2 Minimum conductor cross section fine stranded 0.14 mm2 0.14 mm2 0.2 mm2 0.5 mm2 Maximum conductor cross section fine stranded 4.0 mm2 6.0 mm2 10 mm2 16 mm2 Minimum conductor cross section (flex., stranded) with cable end sleeve 0.5 mm2 0.5 mm2 0.5 mm2 0.5 mm2 Maximum conductor cross section (flex., stranded) with cable end sleeve 2.5 mm2 4.0 mm2 6.0 mm2 10 mm2 Conductor cross section AWG AWG26 to AWG12 AWG26 to AWG10 AWG24 to AWG8 AWG20 to AWG6 Wire strip length 4 9 mm 9 mm 11 mm 13 mm Tightening torque 0.4 Nm 0.5 Nm 1.2 Nm 1.2 Nm Dimensions 5x48.2x56 6x48.2x56 8x48.2x56 10x48.2x56.2 Mounting rail TH35 TH35 TH35 TH35 IEC rated voltage 1,000 V 1,000 V 1,000 V 1,000 V IEC rated current 24 A 32 A 41 A 57 A Rated impulse voltage 8 kV 8 kV 8 kV 8 kV UL rated voltage 600 V 600 V 600 V 600 V UL rated current 20 A 30 A 50 A 65 A End Covers XW5E-S2.5-1.1-1 XW5E-S2.5-1.1-1 XW5E-S2.5-1.1-1 XW5E-S2.5-1.1-1 Applicable nameplates XW5Z-S2.5LB XW5Z-S4.0LB@ XW5Z-S6.0LB@ Applicable Short Bars XW5S-S4.0-@ (@: Poles = 2, 3, 4, 5 or 10) XW5S-S4.0-@ (@: Poles = 2, 3, 4, 5 or 10) XW5S-S6.0-@ (@: Poles = 2,3, 4, or 5) --XW5S-S10-@ (@: Poles = 2) XW5T Feed Through Terminal Blocks Model XW5T-S16-1.1-1(BL) XW5T-S35-1.1-1(BL) 1 tier, 1:1 XW5T-S70-1.1-1(BL) 1 tier, 1:1 XW5T-S150-1.1-1(BL) 1 tier, 1:1 1 tier, 1:1 Applicable wire sizes Appearance and internal wiring NOMINAL CROSS SECTION 16 mm2 35 mm2 Minimum conductor cross section solid 1.5 mm2 10 mm2 --- --- Maximum conductor cross section solid 16 mm2 10 mm2 --- --- Minimum conductor cross section fine stranded 4.0 mm2 10 mm2 10 mm2 35 mm2 Maximum conductor cross section fine stranded 25 mm2 35 mm2 70 mm2 150 mm2 Minimum conductor cross section (flex., stranded) with cable end sleeve 1.5 mm2 --- --- --- Maximum conductor cross section (flex., stranded) with cable end sleeve 16 mm2 --- --- --- Conductor cross section AWG AWG14 to AWG4 Wire strip length 70 mm2 AWG10 to AWG 1/0 150 mm2 AWG6 to AWG 2/0 AWG 2/0 to 350 kcmil 15 mm 18 mm 24 mm 30 mm Tightening torque 2 Nm 3 Nm 6 Nm 10 Nm Dimensions 12x58.5x62 16x63x75.1 24x75.2x88.7 28x96x106.1 Mounting rail TH35 TH35 TH35 TH35 IEC rated voltage 1,000 V 800 V 800 V 1,000 V IEC rated current 76 A 124 A 179 A 309 A Rated impulse voltage 8 kV 8 kV 8 kV 8 kV UL rated voltage 600 V 600 V 600 V 600 V UL rated current 85 A 150 A 175 A 335 A End Covers XW5E-S16 Applicable nameplates Applicable Short Bars --XW5S-S16-@ (@: Poles = 2) --- --- --- --- --- --- 5 XW5T Feed Through Terminal Blocks Model XW5T-S2.5-1.1-2 XW5T-S2.5-1.1-2V 2 tiers, 2:2 XW5T-S4.0-1.2-1(BL) 2 tiers, 2:2 1 tier, 1:2 Appearance and internal wiring NOMINAL CROSS SECTION Applicable wire sizes Minimum conductor cross section solid 6 2.5 mm2 2.5 mm2 2 0.2 mm 2 0.14 mm2 2 6.0 mm2 0.2 mm 2 4.0 mm2 Maximum conductor cross section solid 4.0 mm 4.0 mm Minimum conductor cross section fine stranded 0.14 mm2 0.14 mm2 0.14 mm2 Maximum conductor cross section fine stranded 2.5 mm2 2.5 mm2 6.0 mm2 Minimum conductor cross section (flex., stranded) with cable end sleeve --- --- 0.5 mm2 Maximum conductor cross section (flex., stranded) with cable end sleeve --- --- 4.0 mm2 Conductor cross section AWG AWG22 to AWG12 AWG22 to AWG12 AWG26 to AWG10 Wire strip length 8 mm 8 mm 9 mm Tightening torque 0.4 Nm 0.4 Nm 0.5 Nm Dimensions 5x65.8x71.4 5x65.8x71.4 6x58x56 Mounting rail TH35 TH35 TH35 IEC rated voltage 500 V 500 V 500 V IEC rated current 24 A 24 A 32 A Rated impulse voltage 6 kV 6 kV 6 kV UL rated voltage 600 V 600 V 300 V UL rated current 20 A 20 A 30 A End Covers XW5E-S2.5N XW5E-S2.5N XW5E-S4.0-1.2-1 Applicable nameplates XW5Z-2.5LB@ XW5Z-2.5LB@ XW5Z-4.0LB@ Applicable Short Bars XW5S-S2.5-@N (@: Poles = 2, 3, 4, 5, or 10) XW5S-S2.5-@N (@: Poles = 2, 3, 4, 5, or 10) XW5S-S4.0-@ (@: Poles = 2, 3, 4, 5, or 10) XW5T Feed Through Terminal Blocks Model XW5T-S4.0-2.2-1(BL) XW5T-S4.0-1.1-2 1 tier, 2:2 XW5T-S4.0-1.1-2V 2 tiers, 1:1 2 tiers, 1:1 Appearance and internal wiring 4.0 mm2 4.0 mm2 4.0 mm2 Minimum conductor cross section solid 0.14 mm2 0.14 mm2 0.14 mm2 Maximum conductor cross section solid 6.0 mm2 6.0 mm2 6.0 mm2 Minimum conductor cross section fine stranded 0.14 mm2 0.14 mm2 0.14 mm2 Maximum conductor cross section fine stranded 6.0 mm2 6.0 mm2 6.0 mm2 Minimum conductor cross section (flex., stranded) with cable end sleeve 0.5 mm2 0.5 mm2 0.5 mm2 Maximum conductor cross section (flex., stranded) with cable end sleeve 4.0 mm2 4.0 mm2 4.0 mm2 Conductor cross section AWG AWG26 to AWG10 AWG26 to AWG10 AWG26 to AWG10 Wire strip length 9 mm 9 mm 9 mm Tightening torque 0.5 Nm 0.5 Nm 0.5 Nm Dimensions 6x69x58 6x73x75 6x73x75 Mounting rail TH35 TH35 TH35 IEC rated voltage 500 V 800 V 800 V IEC rated current 32 A 32 A 32 A Rated impulse voltage 6 kV 8 kV 8 kV UL rated voltage 300 V 300 V 300 V UL rated current 30 A 30 A 30 A End Covers XW5E-S4.0-2.2-1 XW5E-S4.0-1.1-2 XW5E-S4.0-1.1-2 Applicable nameplates XW5Z-4.0LB@ XW5Z-4.0LB@ XW5Z-4.0LB@ Applicable Short Bars XW5S-S4.0-@ (@: Poles = 2, 3, 4, 5, or 10) XW5S-S4.0-@ (@: Poles = 2, 3, 4, 5, or 10) XW5S-S4.0-@ (@: Poles = 2, 3, 4, 5, or 10) Applicable wire sizes NOMINAL CROSS SECTION 7 XW5T Grounding Terminal Blocks Model XW5G-S2.5-1.1-1 XW5G-S4.0-1.1-1 XW5G-S6.0-1.1-1 XW5G-S10-1.1-1 1 tier, 1:1 1 tier, 1:1 1 tier, 1:1 1 tier, 1:1 Applicable wire sizes Appearance and internal wiring NOMINAL CROSS SECTION 2.5 mm2 Minimum conductor cross section solid 0.14 mm 0.14 mm Maximum conductor cross section solid 4.0 mm 6.0 mm Minimum conductor cross section fine stranded 0.14 mm2 0.14 mm2 0.2 mm2 0.5 mm2 Maximum conductor cross section fine stranded 4.0 mm2 6.0 mm2 10 mm2 16 mm2 Minimum conductor cross section (flex., stranded) with cable end sleeve 0.5 mm2 0.5 mm2 0.5 mm2 0.5 mm2 Maximum conductor cross section (flex., stranded) with cable end sleeve 2.5 mm2 4.0 mm2 6.0 mm2 10 mm2 Conductor cross section AWG AWG26 to AWG12 AWG26 to AWG10 AWG24 to AWG8 AWG20 to AWG6 Wire strip length 4.0 mm2 2 2 6.0 mm2 10 mm2 0.2 mm 0.5 mm2 10 mm 2 2 16 mm2 2 9 mm 9 mm 11 mm 13 mm Tightening torque 0.4 Nm 0.5 Nm 1.2 Nm 1.2 Nm Dimensions 5x48.2x56 6x48.2x56 8x48.2x56 10x48.2x56.2 Mounting rail TH35 TH35 TH35 TH35 IEC rated voltage 1,000 V 1,000 V 1,000 V 1,000 V IEC rated current --- --- --- --- Rated impulse voltage 8 kV 8 kV 8 kV 8 kV UL rated voltage 600 V 600 V 600 V 600 V UL rated current --- End Covers XW5E-S2.5 Applicable nameplates XW5Z-S2.5LB@ Applicable Short Bars 8 2 --XW5E-S2.5 --- --XW5E-S2.5 XW5Z-S4.0LB@ --- --XW5E-S2.5 XW5Z-S6.0LB@ --- ----- XW5T Grounding Terminal Blocks Model XW5G-S16-1.1-1 XW5G-S35-1.1-1 1 tier, 1:1 XW5G-S70-1.1-1 1 tier, 1:1 1 tier, 1:1 Appearance and internal wiring 16 mm2 35 mm2 Minimum conductor cross section solid 1.5 mm2 10 mm2 --- Maximum conductor cross section solid 16 mm2 35 mm2 --- Minimum conductor cross section fine stranded 4.0 mm2 10 mm2 10 mm2 Maximum conductor cross section fine stranded 25 mm2 35 mm2 70 mm2 Minimum conductor cross section (flex., stranded) with cable end sleeve 1.5 mm2 --- --- Maximum conductor cross section (flex., stranded) with cable end sleeve 16 mm2 --- --- Conductor cross section AWG AWG14 to AWG4 AWG10 to AWG2 AWG6 to AWG 2/0 Wire strip length 15 mm 20 mm 24 mm Tightening torque 2 Nm 3 Nm 6 Nm Dimensions 12x58.5x62 16x63x75.1 24x75.2x88.7 Mounting rail TH35 TH35 TH35 IEC rated voltage 1000 V 800 V 800 V Applicable wire sizes NOMINAL CROSS SECTION IEC rated current --- Rated impulse voltage 8 kV UL rated voltage 600 V UL rated current End Covers 70 mm2 --8 kV 600 V --XW5E-S16 --8 kV 600 V --- --- --- --- Applicable nameplates --- --- --- Applicable Short Bars --- --- --- 9 XW5T Grounding Terminal Blocks Model XW5G-S4.0-1.2-1 XW5G-S4.0-2.2-1 1 tier, 1:2 XW5G-S4.0-1.1-2 1 tier, 2:2 2 tiers, 1:1 Applicable wire sizes Appearance and internal wiring NOMINAL CROSS SECTION 4.0 mm2 4.0 mm2 Minimum conductor cross section solid 0.14 mm 2 4.0 mm2 0.14 mm2 2 2 6 mm2 Maximum conductor cross section solid 6 mm 6 mm Minimum conductor cross section fine stranded 0.14 mm2 0.14 mm2 0.14 mm2 Maximum conductor cross section fine stranded 6 mm2 6 mm2 6 mm2 Minimum conductor cross section (flex., stranded) with cable end sleeve 0.5 mm2 0.5 mm2 0.5 mm2 Maximum conductor cross section (flex., stranded) with cable end sleeve 4 mm2 4 mm2 4 mm2 Conductor cross section AWG AWG26 to AWG10 AWG26 to AWG10 AWG26 to AWG10 Wire strip length 9 mm 9 mm 9 mm Tightening torque 0.5 Nm 0.5 Nm 0.5 Nm Dimensions 6x58x56 6x69x58 6x73x75 Mounting rail TH35 TH35 TH35 IEC rated voltage 500 V 500 V IEC rated current --- 800 V --- --- Rated impulse voltage 6 kV 6 kV 8 kV UL rated voltage 300 V 300 V 300 V UL rated current --- --- --- End Covers XW5E-S4.0-1.2-1 XW5E-S4.0-2.2-1 XW5E-S4.0-1.1-2 Applicable nameplates XW5Z-4.0LB@ XW5Z-4.0LB@ XW5Z-4.0LB@ Applicable Short Bars 10 0.14 mm 2 --- --- --- XW5T Terminal Blocks with Fuses Model XW5T-S4.0-FU5 XW5T-S4.0-FU6 1 tier, 1:1 1 tier, 1:1 Applicable wire sizes Appearance and internal wiring NOMINAL CROSS SECTION 4.0 mm2 4.0 mm2 Minimum conductor cross section solid 0.5 mm2 0.5 mm2 Maximum conductor cross section solid 6 mm2 6 mm2 Minimum conductor cross section fine stranded 0.5 mm2 0.5 mm2 Maximum conductor cross section fine stranded 4 mm2 4 mm2 Minimum conductor cross section (flex., stranded) with cable end sleeve --- --- Maximum conductor cross section (flex., stranded) with cable end sleeve --- --- Conductor cross section AWG AWG22 to AWG10 Wire strip length 8 mm AWG22 to AWG10 8 mm Tightening torque 0.5 Nm 0.5 Nm Dimensions 8x77.2x62 10x77.2x62 Mounting rail TH35 TH35 IEC rated voltage 800 V 800 V IEC rated current 6.3 A 10 A Rated impulse voltage 8 kV 8 kV UL rated voltage 600 V 600 V UL rated current 15 A 15 A End Covers --- --- Applicable nameplates --- --- Applicable Short Bars --- --- Technical Information for XW5T-S4.0-FU5, XW5T-S4.0-FU6 The fuse blocks of this type have a flip top disconnect lever. It accepts miniature fuses of 5x20, 5x25 and 5x30 mm (terminal width: 8 mm) or 6.3x32 mm (terminal width: 10 mm). The hinged lever has latch points both in the open and in the closed position, and can be sealed. Depending on the application and the installation method, the circumstances for increased temperature must be checked in the closed fuse holders. Higher ambient temperatures are an additional load for the fuse inserts. Therefore, the reduction of the rated current must be considered accordingly in these applications. 11 XW5T Disconnect Terminal Blocks Model XW5T-S4.0-KD 1 tier, 1:1 Applicable wire sizes Appearance and internal wiring NOMINAL CROSS SECTION 4.0 mm2 Minimum conductor cross section solid 0.14 mm2 Maximum conductor cross section solid 6 mm2 Minimum conductor cross section fine stranded 0.14 mm2 Maximum conductor cross section fine stranded 6 mm2 Minimum conductor cross section (flex., stranded) with cable end sleeve 0.5 mm2 Maximum conductor cross section (flex., stranded) with cable end sleeve 4 mm2 Conductor cross section AWG AWG26 to AWG10 Wire strip length 9 mm Tightening torque 0.5 Nm Dimensions 6x58x58 Mounting rail TH35 IEC rated voltage 500 V IEC rated current 20 A Rated impulse voltage 6 kV UL rated voltage 300 V UL rated current 16 A End Covers XW5E-S4.0-1.2-1 Applicable nameplates XW5Z-S4.0LB@ Applicable Short Bars XW5S-S4.0-@ Short Bar Model XW5S-S2.5- IEC rated voltage 600 V IEC rated current 20 A UL rated voltage 600 V UL rated current 20 A Compliant standards XW5S-S4.0- XW5S-S6.0- XW5S-S10- 30 A 50 A 57 A 76 A 30 A 50 A 65 A 85 A UL IEC60947-7-1 Characteristics 12 XW5S-S16- 1,000 V Operating temperature range -40 to 60C (with no condensation or icing) Insulating material PA Flammability rating according to UL 94 V0 Operating humidity range 5% to 95% Compliant standards cULus (UL 1059), IEC 60947-7-1 and IEC 60947-7-2 Vibration resistance 5 to 150 Hz 0.964 (m/s2)2/Hz Shock resistance 50 m/s2 30 ms according EN 61373 XW5T Dimensions (Unit: mm) Feed Through Terminal Blocks XW5T-S2.5-1.1-1 XW5T-S4.0-1.1-1 5 6 48.2 48.2 44 44 41 56 41 56 46.8 48.6 46.8 48.6 47.8 47.8 42.2 Mounting rail EN 60715-35x7.5 42.2 Mounting rail EN 60715-35x7.5 Mounting rail EN 60715-35x15 Mounting rail EN 60715-35x15 XW5T-S6.0-1.1-1 XW5T-S10-1.1-1 8 10 48.2 48.2 44 44 41 56 46.8 48.6 48.6 56.2 56.2 48.6 47.8 47.8 42.2 Mounting rail EN 60715-35x7.5 42.2 Mounting rail EN 60715-35x15 Mounting rail EN 60715-35x15 XW5T-S16-1.1-1 Mounting rail EN 60715-35x7.5 XW5T-S35-1.1-1 12 16 58.5 63 57.5 47 62 52.8 54.5 53.7 75.1 69 67.6 27.9 29.3 35.4 47.25 Mounting rail EN 60715-35x15 Mounting rail EN 60715-35x7.5 13.85 Mounting rail EN 60715-35x7.5 Mounting rail EN 60715-35x15 G-rail EN 60715-G32 13 XW5T XW5T-S70-1.1-1 XW5T-S150-1.1-1 24 28 75.2 96 91.7 88.7 82.7 81.2 16.4 106.1 100.1 29.6 98.6 31.1 37.1 19.95 G-rail EN 60715-G32 25.8 Mounting rail EN 60715-35x15 27.3 33.3 G-rail EN 60715-G32 Mouting rail EN 60715-35x7.5 28.25 Mounting rail EN 60715-35x15 XW5T-S2.5-1.1-2 XW5T-S4.0-1.2-1 6 5 65.8 58 56 34 43 56 48.8 48 63.9 47.8 68.4 71.4 42.2 G-rail EN 60715-G32 Mounting rail EN 60715-35x7.5 Mounting rail EN 60715-35x7.5 Mounting rail EN 60715-35x15 Mounting rail EN 60715-35x15 XW5T-S4.0-2.2-1 XW5T-S4.0-1.1-2 6 6 69 73 68 72 37.7 58 50 75 67 52.4 Mounting rail EN 60715-35x7.5 Mounting rail EN 60715-35x15 54.5 Mounting rail EN 60715-35x15 14 Mounting rail EN 60715-35x7.5 XW5T XW5T-S4.0-FU5 XW5T-S4.0-FU6 10 8 77.2 77.2 54.5 54.5 59 59 62 56.6 Mounting rail EN 60715-35x15 Mounting rail EN 60715-35x7.5 G-rail EN 60715-G 32 56.6 Mounting rail EN 60715-35x15 62 Mounting rail EN 60715-35x7.5 G-rail EN 60715-G 32 XW5T-S4.0-KD 6 58 56 58 50 Mounting rail EN 60715-35x7.5 42.2 Mounting rail EN 60715-35x15 Grounding Terminal Blocks XW5G-S2.5-1.1-1 XW5G-S4.0-1.1-1 6 5 48.2 48.2 44 44 47.8 47.8 42.2 46.8 48.6 46.8 48.6 41 56 41 56 42.2 Mounting rail EN 60715-35x7.5 Mounting rail EN 60715-35x7.5 Mounting rail EN 60715-35x15 Mounting rail EN 60715-35x15 XW5G-S6.0-1.1-1 XW5G-S10-1.1-1 8 10 48.2 48.2 44 44 41 56 46.8 48.6 47.8 41 56 46.8 48.6 47.8 42.2 Mounting rail EN 60715-35x15 Mounting rail EN 60715-35x7.5 42.2 Mounting rail EN 60715-35x7.5 Mounting rail EN 60715-35x15 15 XW5T XW5G-S16-1.1-1 XW5G-S35-1.1-1 12 16 58.5 63 57.5 47 62 75.1 52.8 54.5 69 53.7 67.6 27.9 29.3 35.4 Mounting rail EN 60715-35x7.5 47.25 Mounting rail EN 60715-35x15 Mounting rail EN 60715-35x7.5 Mounting rail EN 60715-35x15 13.85 G-rail EN 60715-G32 XW5G-S70-1.1-1 XW5G-S4.0-1.2-1 6 24 58.6 56 75.2 43 56 48.8 48.6 47.8 88.7 82.7 81.2 16.4 42.2 Mounting rail EN 60715-35x7.5 Mounting rail EN 60715-35x15 29.6 31.1 37.1 G-rail EN 60715-G32 19.95 Mounting rail EN 60715-35x15 XW5G-S4.0-2.2-1 XW5G-S4.0-1.1-2 6 6 69 73 68 72 37.7 58 50 75 67 52.4 Mounting rail EN 60715-35x7.5 Mounting rail EN 60715-35x15 54.5 Mounting rail EN 60715-35x15 16 Mounting rail EN 60715-35x7.5 XW5T Short Bars XW5S-S2.5- For XW5 -S2.5Model (2.1) L (14) (23.9) (5) (1.65) l XW5S-S4.0- I (mm) L (mm) XW5S-S2.5-2 5 10 XW5S-S2.5-3 10 15 XW5S-S2.5-4 15 20 XW5S-S2.5-5 20 25 XW5S-S2.5-10 45 50 For XW5 -S4.02.4 L 14 23.9 6 1.75 l XW5S-S6.0- L (mm) 6 12 XW5S-S4.0-3 12 18 XW5S-S4.0-4 18 24 XW5S-S4.0-5 24 30 XW5S-S4.0-10 54 60 Model 9 29.6 1.6 l I (mm) For XW5 -S6.0- 3 L Model XW5S-S4.0-2 I (mm) L (mm) XW5S-S6.0-2 8.2 14.7 XW5S-S6.0-3 16.4 22.9 XW5S-S6.0-4 24.6 31.1 XW5S-S6.0-5 32.8 39.3 XW5S-S16-2 XW5S-S10-2 5.4 4 20.5 17.8 18.5 15.2 35 35.8 2.4 10.2 12.2 3.6 Cross Connector with Screw XW5S-S2.5- N For XW5 -S2.5-1.1-2 5 L 9.1 0.8 5 l M2.5 Model I (mm) L (mm) XW5S-S2.5-2N 5 8.9 XW5S-S2.5-3N 10 13.9 XW5S-S2.5-4N 15 18.9 XW5S-S2.5-5N 20 23.9 XW5S-S2.5-10N 45 48.9 17 XW5T End Covers XW5E-S2.5 XW5E-S16 44 57.5 40.6 46.6 47 XW5E-S4.0-1.2-1 XW5E-S4.0-2.2-1 57.4 67.8 55.9 42 42.6 42.7 40.7 XW5E-S4.0-1.1-2 40.6 XW5E-S2.5N 33.8 72 37.7 53.2 62.5 59.5 35.4 32.1 Separator Plates XW5Z-S2.5PT 50.5 49 52.7 18 46.1 33.7 XW5T Label XW5Z-S2.5 9x5=45 4.8 5 8.3 XW5Z-S4.0 59.5 9x6=54 5.75 6 8.3 XW5Z-S6.0 79.5 9x8=72 7.75 8 8.3 19 XW5T Safety Precautions Be sure to read the precautions for all models in the website at the following URL: http://www.ia.omron.com/. Signal Word Definitions Precautions for Safe Use Precautions for Correct Use Supplementary comments on what to do or avoid doing, to use the product safely. Supplementary comments on what to do or avoid doing, to prevent failure to operate, malfunction, or undesirable effects on product performance. 2. Connecting Wires to the Terminal Block Wiring * Double-check all wiring before turning ON the power supply. * After wiring, route the cable so that force is not applied directly to the connections. Wires for Terminal Blocks Precautions for Safe Use * Do not bend a wire past its natural bending radius or pull on it with * Do not damage the cores when stripping the insulation from them. * Always twist stranded wires together before connecting them. * Do not presolder wires. It may not be possible to connect them or remove them. excessive force. Screw Tightening Torque and Applicable Wires Doing so may cause the wire disconnection. When you connect wires to a Terminal Block, use the applicable wires and tightening torque given in the following table. * Do not insert more than one wire into each terminal insertion hole. * Before you start wiring, make sure that the Terminal Block is securely attached and mounted to a DIN Track. If the Terminal Block is not stable, it may fall and possibly injure a worker. * Do not install the Terminal Block upside down when mounting multiple Terminal Blocks. Doing so may cause short circuits with the adjacent Terminal Block. Precautions for Correct Use 1. Precautions for Correct Use * Do not drop the Terminal Block. Terminal Block functionality may be inhibited. * Always attach End Cover. Not doing so may cause electrical shock. * When you wire the Terminal Block, do not subject it or the wires to stress. Secure the wires so that they do not resonate with vibrations from the facilities in installation conditions. * Always turn OFF the power supply before wiring. Electrical shock may occur. Model Wiring method Tightening torque [N*m] (Use a flatblade screwdriver.) Applicable wire sizes Applicable wire sizes with ferrules attached XW5@-S2.5 M2.5 0.4 AWG26-AWG12 AWG20-AWG14 XW5@-S4.0 M3 0.5 AWG26-AWG10 AWG20-AWG12 XW5@-S6.0 M4 1.2 AWG24-AWG8 AWG20-AWG10 XW5@-S10 M4 1.2 AWG20-AWG6 AWG20-AWG8 XW5@-S16 M5 2 AWG12-AWG4 AWG12-AWG6 XW5@-S35 M6 2.5 AWG10-AWG1/0 AWG10-AWG2 XW5@-S70 M8 3.5 AWG6-AWG2/0 AWG6-AWG2/0 XW5@-S150 M10 4 AWG2/0-350kcmil AWG2/0-300kcmil Wire Stripping Lengths If you connect wires directly to the terminals, use the following stripping lengths. Model Stripping length [mm] XW5@-S2.5 9 XW5@-S4.0 9 XW5@-S6.0 11 XW5@-S10 13 XW5@-S16 15 XW5@-S35 18 XW5@-S70 24 XW5@-S150 30 3. Mounting to and Removing from DIN Track Removal Procedure Mounting Procedure (2) Press. (1) Hook. Hook the Unit on the DIN Track. 2. Press the Unit onto the DIN Track to secure it. 20 1. Insert a flat-blade screwdriver into the DIN Track lock. 2. Move the screwdriver like a lever to free the lock. Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron's exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron's sole obligation hereunder shall be, at Omron's election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron's analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer's application or use of the Product. At Buyer's request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer's application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user's programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron's test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron's Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron's representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON Corporation Industrial Automation Company Authorized Distributor: Kyoto, JAPAN Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69, 2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 OMRON ELECTRONICS LLC 2895 Greenspoint Parkway, Suite 200 Hoffman Estates, IL 60169 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 (c) OMRON Corporation 2016 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. CSM_1_4_1217 Cat. No. G125-E1-02 0916 (0316)