DIMENSIONS ARE NOMINAL VALUES IN INCHES UNLESS OTHERWISE
DESIGNATED.
Users should evaluate the suitability of this product for their application. Specications are subject to change without notice. Tyco Electronics also
reserves the right to make changes in materials or processing, which do not affect compliance with any specication, without notication to Buyer.
Page 1 of 1 The TE logo, Tyco Electronics, Cheminax, Raychem and Rayolin are trademarks.
501 Oakside Avenue
Redwood City, California 94063-3800
1-800-227-8816 Fax: 1-650-361-6297
Raychem Wire & Cable
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS
REFERENCED HEREIN. REFERENCED DOCUMENTS SHALL BE OF THE
ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
© 2010 Tyco Electronics Corporation. All rights reserved.
Outer jacket color will be white (designated by a “-9" appended
to the part number, e.g. 2424A3631-9) unless otherwise
specied.
Designate outer jacket color with a dash number in accordance
with MIL-STD-681. Other codes and sufxes may be added to
the part number, as necessary, to capture any additional
requirements imposed by the purchase order.
SPECIFICATION CONTROL DRAWING 2424A3631
CHEMINAX 124 OHM, AWG 24, 7 STRANDS OF AWG 32, TWINAXIAL CABLE Date 8-9-10
Revision A
THIS SPECIFICATION SHEET FORMS A PART OF THE LATEST ISSUE OF RAYCHEM SPECIFICATION 1200.
CONSTRUCTION DETAILS ELECTRICAL CHARACTERISTICS
.223
CONDUCTORS
AWG 24, 7 strands of
AWG 32, Tin-Coated
Copper
DIELECTRICS
Rayolin F
Colors - White/Blue
FILLERS
Radiation Crosslinked,
Modied ETFE
.0240
.0815
.055
.184 1ST SHIELD
AWG 36,
Tin-Coated Copper
2ND SHIELD
AWG 36,
Tin-Coated Copper
.205
JACKET
Radiation Crosslinked,
Modied ETFE
CHARACTERISTIC IMPEDANCE 124 ± 4 ohms, Method C at 1 MHz
MUTUAL CAPACITANCE 12.0 pF/ft. (nominal)
VELOCITY OF PROPAGATION 66% (nominal)
ADDITIONAL REQUIREMENTS
ELECTRICAL
CONDUCTOR RESISTANCE 26.2 ohms/1000 ft. (nominal)
INSULATION RESISTANCE 10,000 megohms (minimum)
for 1000 ft.
JACKET FLAWS
SPARK TEST
IMPULSE TEST 1.0 kV (rms)
6.0 kV (peak)
VOLTAGE WITHSTAND (DIELECTRIC) 1000 volts (rms) (minimum)
ENVIRONMENTAL
FLAMMABILITY Method B
HEAT SHOCK 225°C
LOW TEMPERATURE-COLD BEND -55°C/6.00 inch mandrel
VOLTAGE WITHSTAND
(Post Environmental)
1000 volts (rms), 1 minute
PHYSICAL
INSULATION (DIELECTRIC)
(prior to cabling)
ELONGATION
TENSILE STRENGTH 200% (minimum)
1800 lbf/in2 (minimum)
JACKET
ELONGATION
TENSILE STRENGTH 50% (minimum)
5000 lbf/in2 (minimum)
JACKET THICKNESS .009 inch (nominal)
SHIELD COVERAGE (each) 90% (minimum)
CABLE IDENTIFICATION: Outer jacket shall be marked in contrasting color at
12 inch (nominal) intervals between marks as follows: “ 2424A3631 06090 “
WEIGHT 38.2 lbs/1000 ft. (nominal)
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
TE Connectivity:
2424A3631-6CS3338