CSM_VAQ_DS_E_4_1
1
Pushbutton Switch (Cylindrical 10.5-dia.)
VAQ
Built-in V-series Miniature Basic
Switch for Compatibility with
Business and Consumer Equipment
Momentary operation and lock.
Operation Unit available in six colors.
Improved sense of touch with built-in miniature basic switch.
Refer to Safety Precautions for All Pushbutton Switches
and Safety Precautions on page 4.
Ordering Information
*1. The Operation Unit can be inserted and removed.
*2. The Operation Unit is screwed in.
Specifications
Ratings
Note: 1. The above values are for steady-state currents.
2. Inductive load: Power factor = 0.4 (AC); time constant = 7 ms (DC).
3. The lamp load has an inrush current of 10 times the steady-state current.
4. The motor load has an inrush current of 6 times the steady-state current.
5. The rated values above are for testing conducted under the following conditions.
(1) Ambient temperature: 20 ± 2°C.
(2) Ambient humidity: 65% ± 5%RH
(3) Operating frequency: 20 times/min.
Classifica-
tion
Shape of
Operation Unit
Out-
put
Operation Unit color
Blue (-A) Black (-B) Green (-G) Red (-R) White (-W) Yellow (-Y)
Momentary
operation
*2
1 *1VAQ-4A-K VAQ-4B-K VAQ-4G-K VAQ-4R-K VAQ-4W-K VAQ-4Y-K
1 *2VAQ-4A-L VAQ-4B-L VAQ-4G-L VAQ-4R-L VAQ-4W-L VAQ-4Y-L
2 *22VAQ-4A 2VAQ-4B 2VAQ-4G 2VAQ-4R 2VAQ-4W 2VAQ-4Y
Lock 1 *2VAQR-4A VAQR-4B VAQR-4G VAQR-4R VAQR-4W
Item
Built-in Switch
Rated
voltage (V)
Non-inductive load (A) Inductive load (A)
Resistive
load Lamp load Inductive
load Motor load
V-15-1A5
125 VAC 15 2 10 3
250 VAC 15 2 10 3
8 VDC 15 4 10 6
30 VDC 10 4 10 4
125 VDC 0.6 0.1 0.6 0.1
250 VDC 0.3 0.05 0.3 0.05
11.4
13 dia.
VAQ
2
Specifications
Characteristics
* Malfunction within 1 ms
Operating Characteristics
Contact Form
Approved Standard Ratings
The built-in V-15-1A5 Switch is approved for UL and CSA.
Dimensions
Operating
frequency
Mechanical 120 operations/min
Electrical 20 operations/min
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance 30 mΩ max. (initial value)
Dielectric
strength
Between terminals of
same polarity
1,000 VAC, 50/60 Hz for 1
minute
Between current-
carrying metal part and
ground, and between
each terminal and non-
current-carrying metal
part
1,500 VAC, 50/60 Hz for 1
minute
Vibration
resistance
Malfunction 10 to 55 Hz, 1.5 mm
double amplitude *
Shock
resistance
Destruction 500 m/s2
Malfunction 200 m/s2 max. *
Durability Mechanical 3,000,000 operations min.
Electrical 100,000 operations min.
Weight Approx. 12 to 40 g
Inrush
current
NC 36 A max.
NO 36 A max.
Ambient operating temperature –25 to 80°C (with no icing or
condensation)
Ambient operating humidity 35% to 85%RH
Ambient storage temperature –25 to 80°C (with no icing or
condensation)
Degree of protection IP00
Electric shock protection class Class II
PTI (proof tracking index) 175
Pollution degree 3 (IEC947-5-1)
Output
Operating characteristics 1 2
Operating force OF max. 1.96 N 4.90 N
Releasing force RF min. 0.39 N 0.78 N
Pretravel PT max. 1.3 mm 1.6 mm
Name Contact form
Double-throw contacts NC
NO
COM
Insert one of the following letters into the box (@) in the model number. Refer to Ordering Information for color symbols.
(Unit: mm)
Note: The Operation Unit can be
inserted and removed.
*2 *3
*1
11.4 10 8.6 10.3
FP: 24.5 max.
21.9
25
13 dia.
22.2 28
38
15 dia. (lock washer)
One, M10
7
3
5.6 dia. 6 dia.
11 18
3 × 16 tapping screw
*4
Width across hexagonal nut flats: 14,
Thickness: 2.
Face nut thickness: 2, Diameter: 14.
*1. Unthreaded screw section: Approx. one thread
*2. Thermoplastic resin foam
*3. V-15-1A5 Miniature Basic Switch
*4. Three, #187 tab/solder terminals (t = 0.5)
VAQ-4@-K
VAQ
3
Panel Cutout (Unit: mm)
Note: The Operation Unit is
mounted with M3 screws.
11.4 10 8.6 10.3
21.9
25
22.2 28
38
7
3
11 18
*2 *3
*1
FP: 24.5 max.
13 dia.
15 dia. (lock washer)
One, M10
5.6 dia. 6 dia.
3 × 16 tapping screw
*4
Width across hexagonal nut flats: 14,
Thickness: 2.
Face nut thickness: 2, Diameter: 14.
*1. Unthreaded screw section: Approx. one thread
*2. Thermoplastic resin foam
*3. V-15-1A5 Miniature Basic Switch
*4. Three, #187 tab/solder terminals (t = 0.5)
VAQ-4@-L
Note: The Operation Unit is
mounted with M3 screws.
24.5
6.2 16 max.
2
25
22.2 283838
5.5
1.8
11.4 10 7.1 10.3
21.3
29
3
*3*2
*1
FP: 24.5 max.
13 dia.
15 dia. (lock washer)
One, M10
Two, M3 × 16 pan-head mounting screws
*4
Width across hexagonal nut flats: 14,
Thickness: 2.
Face nut thickness: 2, Diameter: 14.
*1. Unthreaded screw section: Approx. one thread
*2. V-15-1A5 Miniature Basic Switch
*3. Separator (t = 0.18 mm) (varnished Tetron cloth)
*4. Six, #187 tab/solder terminals (t = 0.5)
VAQR-4@
Note: The Operation Unit is
mounted with M3 screws.
2.7
0.8
4
10.38.1
2
6
25.3
22.2 39
29.2
38
11.4 10 21.4
29
*3
*2
*1
FP: 24.5 max.
13 dia.
*4
*1. Unthreaded screw section: Approx. one thread
*2. Two V-15-1A5 Miniature Basic Switches
*3. Separator (t = 0.18 mm) (varnished Tetron cloth)
*4. Six, #187 tab/solder terminals (t = 0.5)
15 dia. (lock washer)
One, M10
Two, M3 × 28 tapping screw
Width across hexagonal nut flats: 14,
Thickness: 2.
Face nut thickness: 2, Diameter: 14.
2VAQ-4@
10.5 ± 0.3 dia.
Note: Recommended panel
thickness: 1 to 4 mm.
VAQ
4
Safety Precautions
Refer to Safety Precautions for All Pushbutton Switches.
Operation Unit Mounting
VAQ-4@-K
The Operation Unit can be inserted and removed.
Mounting can be performed by inserting the slit of the Operation
Unit into the mounting screw of the Switch.
Mounting force: 39.2 N max.
Removing strength: 22.5 N min.
VAQ-4@-L
The Operation Unit is screwed in.
Mounting can be performed by inserting the M3 screw of the
Operation Unit into the flange of the Switch.
Tighten the Operation Unit to a torque of 0.20 to 0.39 N·m.
2VAQ-4@
VAQR-4@
The Operation Unit is screwed in.
Mounting can be performed by inserting the M3 screw of the
Operation Unit into the metal flange of the Switch.
Tighten the Operation Unit to a torque of 0.20 to 0.39 N·m.
Mounting
Tighten the nut to a torque of 0.49 to 0.78 N·m.
Do not perform wiring with power supplied to the Switch. Do not
touch the terminals or other charged parts of the Switch while
power is being supplied. Doing so may result in electric shock.
After wiring the Switch, ensure an appropriate insulating distance.
Wiring
Twist the conductors through the terminal holes before soldering.
To perform soldering on solder terminals, use a soldering iron with
a capacity of 60 W maximum and complete soldering within 5
seconds. Wait for one minute after soldering before exerting any
external force on the solder.
For connection with tab terminals, gently insert receptacles for
#187 tabs in the terminal push-out direction.
The Switch does not have a ground terminal.
Operation Unit Models
Panel Mounting and Operation Unit Mounting
Operation Unit Mounting
VAQ-4@-K
The Operation Unit can be inserted
and removed.
Mounting can be performed by
inserting the slit of the Operation Unit
into the mounting screw of the Switch.
Mounting force: 39.2 N max.
Removing strength: 22.5 N min.
VAQ-4@-L, 2VAQ-4@, VAQR-4@
The Operation Unit is screwed in.
Mounting can be performed by
inserting the M3 screw of the
Operation Unit into the flange of the
Switch.
Tighten the Operation Unit to a torque
of 0.20 to 0.39 N·m.
Panel Mounting
Tighten the hexagonal nut using a wrench while securing the Switch
by holding it with your fingers.
(Hexagonal nut tightening torque: 0.98 N·m)
Locking Method
VAQR-@@
To turn ON the lock, press the Operation Unit and turn it clockwise
as indicated at the top of the Operation Unit.
To release the lock, turn the Operation Unit counterclockwise.
Precautions for Correct Use
Method Insert/remove Screw-mounted
Operation Unit color
Blue (A) VAQ-BA HEAD VAQ-4A YO HEAD
Black (B) VAQ-BB HEAD VAQ-4B YO HEAD
Green (G) VAQ-BG HEAD VAQ-4G YO HEAD
Red (R) VAQ-BR HEAD VAQ-4R YO HEAD
White (W) VAQ-BW HEAD VAQ-4W YO HEAD
Yellow (Y) VAQ-BY HEAD VAQ-4Y YO HEAD
Operation Unit
Slit Insert/remove
Mounting screw
Operation Unit
M3 screws
Flange
Screw-mounted
Lock washer
Face nut
Panel
Hexagonal nut
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2010.10
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2010 All Right Reserved.