CSM_D4C_DS_E_11_4
1
Enclosed Switch
D4C
Compact Limit Switch That's Also
Thin and Highly Sealed
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on
approved models.)
Sealing characteristics that meet IEC IP67 degree of
protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)
Be sure to read Safety Precautions on page 13 to 14 and
Safety Precautions for All Limit Switches.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Model Number Structure
Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.)
Standard Models
D4C-@@@
(1)(2)(3)
(1) Rated Current
1: 5 A at 250 VAC, 4 A at 30 VDC
2: 5 A at 125 VAC (with LED indicator)
3: 4 A 30 VDC (with LED indicator)
4: 0.1 A at 125 VAC, 0.1 A at 30 VDC
5: 0.1 A at 125 VAC (with LED indicator)
6: 0.1 A at 30 VDC (with LED indicator)
(2) Cable Specifications
2: VCTF oil-resistant cable (3 m)
3: VCTF oil-resistant cable (5 m)
4: VCTF (3 m)
5: VCTF (5 m)
6: SJT(O) (3 m)
7: SJT(O) (5 m)
(3) Actuator
01: Pin plunger
02: Roller plunger
03: Crossroller plunger
20: Roller lever
24: Roller lever (high-sensitivity model)
31: Sealed pin plunger
32: Sealed roller plunger
33: Sealed crossroller
50: Plastic rod
60: Center roller lever
Pre-wired Models
D4C-@0@@-@@@@@@
(1) (2) (3) (4)
(1) Rated Current
1: 1 A at 125 VAC, 1 A at 30 VDC
(Without operation indicator)
2: 1 A at 125 VAC (with operation indicator)
3: 1 A at 30 VDC (with operation indicator)
(2) Actuator
01: Pin plunger
02: Roller plunger
31: Sealed plunger
32: Sealed roller plunger
24: Roller lever (high-sensitivity model)
(3) Wiring Specifications
DK1EJ: Pre-wired models
(3 conductors: DC specification)
AK1EJ: Pre-wired models
(3 conductors: AC specification)
M1J: Connector models for ASI devices
(2 conductors: NO wiring)
(4) Cable length
03: 0.3 m
Wiring Specifications
Internal switch Connector
COM 3
NC 2
NO 4
Weather-resistant Models
D4C-@@@-P
(1)(2)(3) (4)
(1) Rated Current
1: 5 A at 250 VAC, 4 A at 30 VDC
2: 5 A at 125 VAC (with LED indicator)
3: 4 A at 30 VDC (with LED indicator)
4: 0.1 A at 125 VAC, 0.1 A at 30 VDC
(2) Cable Specifications
2: VCTF oil-resistant cable (3 m)
3: VCTF oil-resistant cable (5 m)
(3) Actuator
20: Roller lever
24: Roller lever (high-sensitivity model)
27: Adjustable roller lever
29: Adjustable rod lever
(4) Structure
P: Weather-resistant
2
D4C
Ordering Information
Switches
Standard Switches with No Operation Indicator
Note: 1. Models are available separately with resistance to viscous oils (oil drain holes are provided), but only with Plunger Models. Add “-M” to the model number
(example: D4C-1202 would be D4C-1202-M). Ask your nearest OMRON representative for details.
2. Switches with variable roller levers are also available. Ask your nearest OMRON representative for details.
*1. Oil-resistant vinyl cabtire cables; approved by EN and IEC.
*2. Ordinary vinyl cabtire cables.
*3. Switches with SJT(O) Cables (cables approved by UL and CSA) are approved by UL and CSA.
Actuator
Ratings
Cable
Cable
length
(m)
Standard load Microload
5 A at 250 VAC, 4 A at 30 VDC 0.1 A at 125 VAC, 0.1 A at 30 VDC
VCTF oil-resistant
cable *1VCTF cable *2SJT(O) cable *3VCTF oil-resistant
cable *1VCTF cable *2
Model
Pin plunger
3D4C-1201 D4C-1401 D4C-1601 D4C-4201 D4C-4401
5D4C-1301 D4C-1501 D4C-1701 D4C-4301 D4C-4501
Roller plunger
3D4C-1202 D4C-1402 D4C-1602 D4C-4202 D4C-4402
5D4C-1302 D4C-1502 D4C-1702 D4C-4302 D4C-4502
Crossroller
plunger
3D4C-1203 D4C-1403 D4C-1603 D4C-4203 D4C-4403
5D4C-1303 D4C-1503 D4C-1703 D4C-4303 D4C-4503
Roller lever
3D4C-1220 D4C-1420 D4C-1620 D4C-4220 D4C-4420
5D4C-1320 D4C-1520 D4C-1720 D4C-4320 D4C-4520
Roller lever,
high-
sensitivity
3D4C-1224 D4C-1424 D4C-1624 D4C-4224 D4C-4424
5D4C-1324 D4C-1524 D4C-1724 D4C-4324 D4C-4524
Sealed pin
plunger
3D4C-1231 D4C-1431 D4C-1631 D4C-4231 D4C-4431
5D4C-1331 D4C-1531 D4C-1731 D4C-4331 D4C-4531
Sealed roller
plunger
3D4C-1232 D4C-1432 D4C-1632 D4C-4232 D4C-4432
5D4C-1332 D4C-1532 D4C-1732 D4C-4332 D4C-4532
Sealed
crossroller
plunger
3D4C-1233 D4C-1433 D4C-1633 D4C-4233 D4C-4433
5D4C-1333 D4C-1533 D4C-1733 D4C-4333 D4C-4533
Plastic rod
3D4C-1250 D4C-1450 D4C-1650 D4C-4250 D4C-4450
5D4C-1350 D4C-1550 D4C-1750 D4C-4350 D4C-4550
Center roller
lever
3D4C-1260 D4C-1460 D4C-1660 D4C-4260 D4C-4460
5D4C-1360 D4C-1560 --- D4C-4360 D4C-4560
3
D4C
Standard Switches with Operation Indicator (Red)
Note: Ask your nearest OMRON representative for information on Switching with approved international standards.
*1. Oil-resistant vinyl cabtire cables; approved by EN and IEC.
*2. Ordinary vinyl cabtire cables.
Actuator
Ratings
Cable
Cable
length (m)
5 A at 125 VAC 4 A at 30 VDC
VCTF oil-resistant
cable *1VCTF cable *2VCTF oil-resistant
cable *1VCTF cable *2
Model
Pin plunger
3D4C-2201 D4C-2401 D4C-3201 D4C-3401
5D4C-2301 D4C-2501 D4C-3301 D4C-3501
Roller plunger
3D4C-2202 D4C-2402 D4C-3202 D4C-3402
5D4C-2302 D4C-2502 D4C-3302 D4C-3502
Crossroller
plunger
3D4C-2203 D4C-2403 D4C-3203 D4C-3403
5D4C-2303 D4C-2503 D4C-3303 D4C-3503
Roller lever
3D4C-2220 D4C-2420 D4C-3220 D4C-3420
5D4C-2320 D4C-2520 D4C-3320 D4C-3520
Roller lever,
high-
sensitivity
3D4C-2224 D4C-2424 D4C-3224 D4C-3424
5D4C-2324 D4C-2524 D4C-3324 D4C-3524
Sealed pin
plunger
3D4C-2231 D4C-2431 D4C-3231 D4C-3431
5D4C-2331 D4C-2531 D4C-3331 D4C-3531
Sealed roller
plunger
3D4C-2232 D4C-2432 D4C-3232 D4C-3432
5D4C-2332 D4C-2532 D4C-3332 D4C-3532
Sealed
crossroller
plunger
3D4C-2233 D4C-2433 D4C-3233 D4C-3433
5D4C-2333 D4C-2533 D4C-3333 D4C-3533
Plastic rod
3D4C-2250 D4C-2450 D4C-3250 D4C-3450
5D4C-2350 D4C-2550 D4C-3350 D4C-3550
Center roller
lever
3D4C-2260 D4C-2460 D4C-3260 D4C-3460
5D4C-2360 D4C-2560 D4C-3360 D4C-3560
4
D4C
Standard Switches with Operation Indicator
Note: Ask your nearest OMRON representative for information on Switching with approved international standards.
* Oil-resistant vinyl cabtire cables; approved by EN and IEC.
Pre-wired Models (Use VCTF Oil-resistant Cable)
Note: 1. The @ contains the length of the cable.
For example: 30 cm D4C-2002-AK1EJ03
2. M1J models are also available. Contact your OMRON sales representative for further information.
3. Of the above model numbers, some with special specifications are not registered.
Weather-resistant Models
* Vinyl cabtire cable with excellent oil resistance.
Note: Silicon rubber is used to increase resistance to the environment. Silicon rubber, however, can generate silicon gas. (This can occur at room temperature, but the
amount of silicon gas generated increases at higher temperatures.) Silicon gas will react as a result of arc energy and form silicon oxide (SiO2). If silicon oxide
accumulates on the contacts, contact interference can occur and can interfere with the device. Before using a Switch, test it under actual application conditions
(including the environment and operating frequency) to confirm that no problems will occur in actual.
Actuator
Ratings
Cable
Cable length (m)
0.1 A at 125 VAC 0.1 A at 30 VDC
VCTF oil-resistant cable*VCTF oil-resistant
cable*
Model
Pin plunger 3D4C-5201 D4C-6201
5--- D4C-6301
Roller plunger 3D4C-5202 D4C-6202
5D4C-5302 D4C-6302
Crossroller plunger 3D4C-5203 D4C-6203
5D4C-5303 D4C-6303
Roller lever 3D4C-5220 D4C-6220
5D4C-5320 D4C-6320
Roller lever, high-
sensitivity
3D4C-5224 D4C-6224
5D4C-5324 D4C-6324
Sealed pin plunger 3 --- D4C-6231
5 --- D4C-6331
Sealed roller plunger 3D4C-5232 D4C-6232
5D4C-5332 D4C-6332
Sealed
crossroller plunger
3 --- D4C-6233
5 --- D4C-6333
Plastic rod 3D4C-5250 D4C-6250
5D4C-5350 D4C-6350
Actuator
Ratings 1 A at 125 VAC 1 A at 30 VDC
Operation
indicator Without operation indicator With operation indicator Without operation indicator With operation indicator
Pin plunger --- --- --- D4C-3001-DK1EJ@
Roller plunger D4C-1002-AK1EJ@D4C-2002-AK1EJ@D4C-1002-DK1EJ@D4C-3002-DK1EJ@
Sealed plunger --- --- --- D4C-3031-DK1EJ@
Sealed roller plunger --- --- D4C-1032-DK1EJ@D4C-3032-DK1EJ@
Roller lever (high-
sensitivity model) --- D4C-2024-AK1EJ@D4C-1024-DK1EJ@D4C-3024-DK1EJ@
Actuator
Operation
indicator Without operating indication With operating indication
Standard load Microload Standard load
Ratings
Cable length (m)
5 A at 250 VAC
4 A at 30 VDC
0.1 A at 125 VAC
0.1 A at 30 VDC 5 A at 125 VAC 4 A at 30 VDC
VCTF oil-resistant cable*
Model
Roller lever 3D4C-1220-P D4C-4220-P D4C-2220-P D4C-3220-P
5D4C-1320-P --- --- ---
Roller lever (high-
sensitivity model)
3D4C-1224-P D4C-4224-P D4C-2224-P D4C-3224-P
5D4C-1324-P D4C-4324-P D4C-2324-P D4C-3324-P
Adjustable roller lever 3D4C-1227-P D4C-4227-P D4C-2227-P D4C-3227-P
5D4C-1327-P D4C-4327-P D4C-2327-P D4C-3327-P
Adjustable rod lever 3D4C-1229-P D4C-4229-P --- D4C-3229-P
5D4C-1329-P --- D4C-2329-P D4C-3329-P
5
D4C
Applicable Cables
Mounting Plates (Order Separately)
The WL/WL-N model incorporated by equipment can be replaced with the D4C together with the Mounting Plate without changing the
position of the dog or cam.
List of Replaceable Models
Note: The WL01@ is for micro loads.
Example of Replacement
Note: The position of the dog remains unchanged.
Individual Parts
Head/Actuator
Note: 1. The model numbers for heads are of the form D4C-00@@, with the numbers in the squares indicating the type of actuator.
2. Actuators for plunger models, plastic rod models, and center roller lever models cannot be ordered individually. They must be ordered together with the head.
Type For AC For DC
Appearance No. of
conductors Cable length Model Model
Straight
4
2 m
XS2F-A421-D90-F XS2F-D421-D80-F
5 m
XS2F-A421-G90-F XS2F-D421-G80-F
WL/WL-N model (Actuator) D4C model (Actuator)
Plate
WLD/WL01D/WLD18-N
(Top plunger)
D4C-@@01
(Plunger) D4C-P001
WLD2/WL01D2/WLD28-N
(Top roller plunger)
D4C-@@02
(Roller plunger) D4C-P002
WLCA2/WL01CA2/WLCA2-N
(Roller lever)
D4C-@@20
(Roller lever) D4C-P020
Dog Dog
Mounting
Plate
Actuator Head (with actuator) Actuator
Pin plunger D4C-0001 ---
Roller plunger D4C-0002 ---
Crossroller plunger D4C-0003 ---
Roller lever D4C-0020 WL-1A100
Roller lever (weather-resistant model) --- WL-1A100P1
Roller lever (high-sensitivity model) D4C-0024 WL-1A100
Variable roller lever D4C-0027 ---
Variable rod lever D4C-0029 HL-1HPA500
Sealed pin plunger D4C-0031 ---
Sealed roller plunger D4C-0032 ---
Sealed crossroller plunger D4C-0033 ---
Plastic rod D4C-0050 ---
Center roller lever D4C-0060 ---
6
D4C
Specifications
Approved Standards
Ratings
Standard Model
Pre-wired Model
Approved Standard Ratings
TÜV (EN60947-5-1), CCC (GB14048.5)
UL/CSA
B300 (D4C-16@@, -17@@)
B150 (D4C-26@@, -27@@)
B300
B150
Characteristics
Note: The above figures are initial values.
*1. The values are calculated at an operating temperature of +5°C to +35°C,
and an operating humidity of 40% to 70%RH. Contact your OMRON sales
representative for more detailed information on other operating
environments.
*2. Pre-wired Models: 1,000,000 operations min. (DC specifications, switching
current: 0.1 A)
*3. Outdoor specifications: 500,000 operations min.
*4. Excluding Plastic Rods.
*5. Pre-wired models: 250 V
*6. Pre-wired models: class III
Agency Standard File No.
TÜV Product
Service EN60947-5-1 *1, 3
UL UL508 E76675 *2
CSA CSA C22.2 No.14 LR45746 *2
CCC(CQC) GB14048.5 2003010305077626 *3
*1. Excluding weather-resistant models, only models with VCTF oil-resistant cables
and pre-wired models are certified.
(Contact your OMRON representative for the model numbers.)
Models with VCTF oil-resistant cables and pre-wired models (125 VAC) are
certified for CE Marking.
*2. SJT(O)-cable models only.
(Applicable only to models listed on pages 2 to 3.)
*3. Ask your OMRON representative for information on approved models.
Rated voltage
Non-inductive load (A) Inductive load (A)
Resistive load Lamp load Inductive load Motor load
NC NO NC NO NC NO NC NO
125 VAC
250 VAC
5 (0.1)
5
1.5
1
0.7
0.5
3
2
2.5
1.5
1.3
0.8
8 VDC 5 (0.1) 2 5 4 3
14 VDC 5 (0.1) 2 4 4 3
30 VDC 4 (0.1) 2 3 3 3
125 VDC 0.4 0.05 0.4 0.05
250 VDC 0.2 0.03 0.2 0.03
Inrush
current
NC 20 A max.
NO 10 A max.
Note: 1. The values given on the top are steady-state
currents.
2. Inductive loads have a power factor of 0.4 min.
(AC) and a time constant of 7 ms max. (DC).
3. Lamp loads have an inrush current of 10 times
the steady-state current.
4. Motor loads have an inrush current of 6 times
the steady-state current.
5. The values "0.1" given in parentheses are for
micro load models.
Rated voltage
Non-inductive load (A) Inductive load (A)
Resistive load Lamp load Inductive load Motor load
NC NO NC NO NC NO NC NO
125 VAC1110.71111
30 VDC 11111111
Model Applicable category and
ratings I the
D4C-1@@@ AC-15 2 A/250 V
DC-12 2 A/30 V
5 A
4 A
D4C-2@@@ AC-15 2 A/125 V 5 A
D4C-3@@@ DC-12 2 A/30 V 4 A
D4C-4@@@ AC-14 0.1 A/125 V
DC-12 0.1 A/30 V
0.5 A
0.5 A
D4C-5@@@ AC-14 0.1 A/125 V 0.5 A
D4C-6@@@ DC-12 0.1 A/30 V 0.5 A
Rated voltage Carry current Current (A)
Volt-amperes (VA)
Make Break Make Break
120 VAC
240 VAC 5 A 30
15
3
1.5
3,600
3,600
360
360
Rated voltage Carry current Current (A)
Volt-amperes (VA)
Make Break Make Break
120 VAC 5 A 30 3 3,600 360
Degree of protection IP67
Durability
*1
Mechanical *3 10,000,000 operations min.
Electrical *2
200,000 operations min. (5 A at 125 VAC, resistive load)
Operating speed 0.1 mm/s to 0.5 m/s (in case of plunger)
1 mm/s to 1 m/s (in case of roller lever)
Operating
frequency
Mechanical 120 operations/min
Electrical 30 operations/min
Rated frequency 50/60 Hz
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance (initial)
250 m
Ω
max. (initial value with 2-m VCTF cable)
300 m
Ω
max. (initial value with 3-m VCTF cable)
400 m
Ω
max. (initial value with 5-m VCTF cable)
Dielectric
strength
Between terminals of
the same polarity
1,000 VAC, 50/60 Hz for 1 min
Between current-
carrying metal
part and ground
1,500 VAC, 50/60 Hz for 1 min
Uimp: 2.5 kV (EN60947-5-1)
Between each terminal
and non-current-carry-
ing metal part,
1,500 VAC, 50/60 Hz for 1 min
Uimp: 2.5 kV(EN60947-5-1)
Rated insulation voltage (Ui)
300 V (EN60947-5-1) *5
Pollution degree (operating environment)
3 (EN60947-5-1)
Short-circuit protective device (SCPD)
10 A fuse type gI or gG (IEC60269)
Conditional short-circuit current
100 A (EN60947-5-1)
Conventional enclosed
thermal current (I the) 5 A, 4 A, 0.5 A (EN60947-5-1)
Protection against electric shock
Class I (with grounding wire) *6
Vibration re-
sistance
Malfunction 10 to 55 Hz, 1.5-mm double amplitude *4
Shock re-
sistance
Destruction 1,000 m/s2 max.
Malfunction 500 m/s2 max. *4
Ambient operating temperature
10°C to +70°C (with no icing)
Ambient operating humidity
35% to 95%RH
Weight (D4C-1202) With 3-m VCTF cable: 360 g
With 5-m VCTF cable: 540 g
7
D4C
Engineering Data
Leakage Current for LED-indicator Models
The leakage currents and resistances of LED-indicator models are given in the following table.
Structure and Nomenclature
Structure
Standard Models
Weather-resistant Models
Model Voltage Leakage current Resistance
D4C-2@@@ 125 VAC 1.7 mA 68 k
D4C-3@@@ 30 VDC 1.7 mA 15 k
D4C-5@@@ 125 VAC 1.7 mA 68 k
D4C-6@@@ 30 VDC 1.7 mA 15 k
1,000
300
100
30
10
110234567
125 VAC
250 VAC
3
5
50
Durability (x 104 operations)
Switching current (A)
Operating temperature: 20±2°C
Operating humidity: 65±5°C
Operating frequency: 30 operations/min
(cosΦ= 1, L/R = 0)
Operating temperature: 5°C to 35°C
Operating humidity: 40% to 70%
Operating frequency: 30 operations/min
(cosΦ=1, L/R = 0)
1,000
300
500
700
100
30
10
200 40 60 80 100 120
125 VAC
30 VDC
3
5
50
Durability (x 104 operations)
Switching current (mA)
Electrical Durability
D4C-1@@@, -2@@@, -3@@@ D4C-4@@@, -5@@@, -6@@@
O-ring
(NBR)
Built-in switch
Roller
Lever
Diaphragm (NBR)
O-ring
(NBR)
Protective cap
(NBR)
Ground terminal
Molded resin
Cable
Roller Lever Models Without Indicator
Shaft Section Seal
By fitting an O-ring to the rotary shaft and with
an appropriate interference of the screws,
high-sealing properties are maintained. The O-ring
is made of silicone rubber and is resistant to temperature
changes and adverse weather conditions.
Roller
The roller is made of self-lubricating sintered
stainless steel and boasts high resistance to
wear.
Head-mounting
Screw
Diaphragm
The diaphragm is made of silicone rubber
and is resistant to temperature changes
and adverse weather conditions.
Cable
Vinyl cabtire cable and is resistant
to adverse weather conditions.
Lever
The lever forged of anti-corrosive aluminium
alloy features high corrosion resistances
and outstanding ruggedness.
Built-in Switch
Both standard load and microload models available.
Rotary Shaft
The shaft is made of stainless steel
decreasing the likelihood of rusting.
Roller Lever Setscrew
This screw is made of stainless steel and has high
corrosion resistance.
Roller Lever Models Without Indicator
8
D4C
Contact Form
Standard Models/Weather-resistant Models
Without Operation Indicator
With Operation Indicator
(Lit when Not Actuated)
<24 VDC LED>
<100 VAC LED>
Connector Models for ASI Devices (-M1J)
Without Operation Indicator
With Operation Indicator
(Lit when Not Actuated)
Pre-wired Models (-AK1EJ@, -DK1EJ@)
Without Operation Indicator
With Operation Indicator
(Lit when Not Actuated)
<24 VDC LED>
<100 VAC LED>
*1. NO (white): VCTF oil-resistant cable or VCTF cable.
NO (blue): SJT (O) cable approved by UL and CSA.
*2. E (yellow/green): VCTF oil-resistant cable.
E (green): VCTF cable or SJT (O) cable approved by UL and CSA.
*3. E (ground) is not grounded.
*4. The position of the positioning piece is not fixed. Using an L-shaped
connector may result in failure. Use only a straight connector.
Note: 1. Lit when not Actuated” means that when the actuator is in the free
position, the indicator is lit, and when the actuator is turned or pushed and
the contact comes into contact with the NO side, the indicator turns OFF.
2. Leakage current from indicator circuit may cause load's malfunction.
Please check the load's OFF current before use the indicator-equipped
switch.
E
NC (red)
NO *1
(black)COM
*2
E
NC (red)
(black) COM
NO *1
15 k
*2
E
NC (red)
(black) COM
NO *1
68 k
*2
Pin No.3 COM
NO Pin No.4
R
Pin No.3 COM
NO Pin No.4
NO
COM
Positioning piece*4
For DC
E *3
NO Pin No.4
NC Pin No.2
Pin No.3 COM
E *3
NO Pin No.4
NC Pin No.2
Pin No.3 COM
15 k
E *3
NO Pin No.4
NC Pin No.2
Pin No.3 COM
68 k
NC
NO
COM
Positioning piece*4
NC
NO
COM
Positioning piece*
For AC For DC
9
D4C
Dimensions and Operating Characteristics
Switches
Standard Models
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Model
Operating
characteristics
D4C-@@01 D4C-@@02 D4C-@@03 D4C-@@20
D4C-@@20-P
D4C-@@24
D4C-@@24-P
Operating force OF max.
Release force RF min.
Pretravel PT max.
Overtravel OT min.
Movement Differential
MD max.
11.77 N
4.41 N
1.8 mm
3 mm
0.2 mm
11.77 N
4.41 N
1.8 mm
3 mm
0.2 mm
11.77 N
4.41 N
1.8 mm
3 mm
0.2 mm
5.69 N
1.47 N
25°
40°
3°
5.69 N
1.47 N
10°±3°
50°
3°
Operating Position
OP 15.7±1 mm 28.5±1 mm 28.5±1 mm --- ---
Models without LED indicators are shown in the illustrations and dimensions diagrams. Refer to page 11 for Models with LED Indicators.
The boxes in the model numbers are replaced with the rating and cable type. Refer to page 1 for the Model Number Structure.
OP
PT 16
2.8
2
1.4 1.5
7.5
4.5
8
23
2
34
10 dia. stainless
steel plunger
40 max.
54.2 max. 49 max.
Correct
setting
position
Two, 5.1 +0.2 dia.
holes
Spot facing
10.2 dia. Depth: 6
0
25±0.1
VCTF cable, VCTF oil-resistant cable: 0.75 mm
2
, 4 conductor, Finishing O.D. 7.6 dia.
SJT(O) cable: 0.83 mm
2
, 4 conductor, Finishing O.D. 8.6 dia.
Pin Plunger
D4C-@@01
65 max.
16
38R
7
2
11.4
1.4 1.5
7.5
8
23
2
34
D4C-@@20
VCTF cable, VCTF oil-resistant cable: 0.75 mm
2
, 4 conductor, Finishing O.D. 7.6 dia.
SJT(O) cable: 0.83 mm
2
, 4 conductor, Finishing O.D. 8.6 dia.
D4C-@@20-P (Weather-resistant Models)
VCTF oil-resistant cable* : 0.75 mm
2
, 4 conductor, Finishing O.D. 7.6 dia.
* VCTF oil-resistant cable only.
Two, 5.1 +0.2 dia.
holes
Spot facing
10.2 dia. Depth: 6
0
17.5 dia. x 7 stainless
sintered roller
102.7 max.
40 max.
50 max.
25±0.1
44±0.8
30.2±0.8
31.5±0.8
M5 (length: 12)
Allen-head
bolt
Roller Lever
D4C-@@20
D4C-@@20-P
OP
PT 16
2.8
2
1.4 1.5
7.5
7
8
23
2
34
12 dia. x 4.4 stainless sintered roller
40 max. Correct
setting
position
Two, 5.1
+0.2
dia.
holes
Spot facing
10.2 dia. Depth: 6
0
25±0.1
67 max.
51.5 max.
VCTF cable, VCTF oil-resistant cable: 0.75 mm
2
, 4 conductor, Finishing O.D. 7.6 dia.
SJT(O) cable: 0.83 mm
2
, 4 conductor, Finishing O.D. 8.6 dia.
Roller Plunger
D4C-@@02
OP
PT 16
2.8
2
1.4 1.5
7.5
7
8
23
2
34
12 dia. x 4.4 stainless sintered roller
40 max. Correct
setting
position
Two, 5.1 +0.2 dia.
holes
Spot facing
10.2 dia. Depth: 6
0
25±0.1
67 max.
51.5 max.
VCTF cable, VCTF oil-resistant cable: 0.75 mm
2
, 4 conductor, Finishing O.D. 7.6 dia.
SJT(O) cable: 0.83 mm
2
, 4 conductor, Finishing O.D. 8.6 dia.
Crossroller Plunger
D4C-@@03
16
38R
7
2
11.4
1.4 1.5
7.5
8
23
2
34
65 max.
D4C-@@24
VCTF cable, VCTF oil-resistant cable: 0.75 mm
2
, 4 conductor, Finishing O.D. 7.6 dia.
SJT(O) cable: 0.83 mm
2
, 4 conductor, Finishing O.D. 8.6 dia.
D4C-@@24-P (Weather-resistant Models)
VCTF oil-resistant cable* : 0.75 mm
2
, 4 conductor, Finishing O.D. 7.6 dia.
* VCTF oil-resistant cable only.
Two, 5.1 +0.2 dia.
holes
Spot facing
10.2 dia. Depth: 6
0
17.5 dia. x 7 stainless
sintered roller
102.7 max.
40 max.
50 max.
25±0.1
44±0.8
30.2±0.8
31.5±0.8
M5 (length: 12)
Allen-head
bolt
Roller Lever (High-Sensitivity Model)
D4C-@@24
D4C-@@24-P
10
D4C
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
* The TT is a reference value.
Operating
characteristics
Model D4C-@@31 D4C-@@32 D4C-@@33
Operating force OF max.
Release force RF min.
Pretravel PT max.
Overtravel OT min.
Movement Differential
MD max.
17.65 N
4.41 N
1.8 mm
3 mm
0.2 mm
17.65 N
4.41 N
1.8 mm
3 mm
0.2 mm
17.65 N
4.41 N
1.8 mm
3 mm
0.2 mm
Operating Position
OP
Total travel TT *
24.9±1 mm
(5) mm
34.3±1 mm
(5) mm
34.3±1 mm
(5) mm
OP
PT 16
2
1.4 1.5
7.5
4.0
8
23
2
34
Two, 5.1 +0.2 dia.
holes
Spot facing
10.2 dia. Depth: 6
40 max.
49 max.
10 dia. stainless
steel plunger
25±0.1
Rubber cap
0
VCTF cable, VCTF oil-resistant cable: 0.75 mm2, 4 conductor, Finishing O.D. 7.6 dia.
SJT(O) cable: 0.83 mm2, 4 conductor, Finishing O.D. 8.6 dia.
Sealed Plunger
D4C-@@31
OP
PT 16
2
1.4 1.5
7.5
4.0
8
23
2
34
Two, 5.1 +0.2 dia.
holes
Spot facing
10.2 dia. Depth: 6
0
Rubber cap
12 dia. x 4.4 stainless
sintered roller
40 max.
25±0.1
49 max.
VCTF cable, VCTF oil-resistant cable: 0.75 mm2, 4 conductor, Finishing O.D. 7.6 dia.
SJT(O) cable: 0.83 mm2, 4 conductor, Finishing O.D. 8.6 dia.
Sealed Roller Plunger
D4C-@@32
OP
PT 16
2
1.4 1.5
7.5
4.0
8
23
2
34
Two, 5.1 +0.2 dia.
holes
Spot facing
10.2 dia. Depth: 6
0
Rubber cap
12 dia. x 4.4 stainless
sintered roller
40 max.
25±0.1
49 max.
VCTF cable, VCTF oil-resistant cable: 0.75 mm
2
, 4 conductor, Finishing O.D. 7.6 dia.
SJT(O) cable: 0.83 mm
2
, 4 conductor, Finishing O.D. 8.6 dia.
Sealed Crossroller Plunger
D4C-@@33
11
D4C
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Models with LED Indicator
The dimensions of the LED
indicator for models equipped with
one are shown below.
Pre-wired Models
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
104±2.5
38 3.2 dia.
6.6 dia.
*2
42
16
2
1.4 1.5
7.5
4.5
8
23
2
34
*1
Two, 5.1 +0.2 dia.
holes
Spot facing
10.2 dia. Depth: 6
0
Rubber cap
Nylon rod
40 max.
25±0.1
49 max.
*1 Operation is possible in any direction except in parallel to the axis.
*2 The ideal range for operation is between the tip of the rod and 1/3 of
the length of the actuator.
VCTF cable, VCTF oil-resistant cable: 0.75 mm2, 4 conductor, Finishing O.D. 7.6 dia.
SJT(O) cable: 0.83 mm2, 4 conductor, Finishing O.D. 8.6 dia.
Plastic rod
D4C-@@50
56.9
38R
18.9
16
2
1.5
7.5
11.4
7
8
23
2
34
1.4
Two, 5.1 +0.2 dia.
holes
Spot facing
10.2 dia. Depth: 6
0
40 max.
25±0.1
102.7 max.
17.5 dia. x 7 stainless
sintered roller
VCTF cable, VCTF oil-resistant cable: 0.75 mm2, 4 conductor, Finishing O.D. 7.6 dia.
SJT(O) cable: 0.83 mm2, 4 conductor, Finishing O.D. 8.6 dia.
Center Roller Lever Plunger
D4C-@@60
Operating
characteristics
Model D4C-@@50 D4C-@@60
Operating force OF max.
Release force RF min.
Pretravel PT max.
Overtravel OT min.
Movement Differential
MD max.
1.47 N
---
15°
---
---
6.67 N
1.47 N
10°±3°
50°
3°
Operating Position
OP
Total travel TT
---
---
---
---
(4)
LED
OP
PT 16
2.8
2
1.4
1.5
7.5
4.5
8
23
XS2H-D421
2
34
Two, 5.1 +0.2 dia.
holes
Spot facing
10.2 dia. Depth: 6
0
40 max.
54.2 max. 49 max.
25±0.1
10 dia. stainless
steel plunger
Correct setting
position
6 dia.
Pin Plunger
D4C-@001-@K1EJ@
D4C-@001-M1J@
OP
PT 16
2.8
2
7.5
7
8
23
2
34 1.4
1.5
XS2H-D421
Two, 5.1 +0.2 dia.
holes
Spot facing
10.2 dia. Depth: 6
0
40 max.
25±0.1
12 dia. x 4.4 stainless
sintered roller
67 max.
51.5 max.
Correct setting
position
6 dia.
Roller Plunger
D4C-@002-@K1EJ@
D4C-@002-M1J@
Model
Operating
characteristics
D4C-@001
-@K1EJ@D4C-@002
-@K1EJ@
Operating force OF max.
Release force RF min.
Pretravel PT max.
Overtravel OT min.
Movement Differential
MD max.
11.77 N
4.41 N
1.8 mm
3 mm
0.2 mm
11.77 N
4.41 N
1.8 mm
3 mm
0.2 mm
Operating Position
OP 15.7±1 mm 28.5±1 mm Note: Specifications are the same for -M1J Switches.
12
D4C
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Note: Specifications are the same for -M1J Switches
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Model
Operating
characteristics
D4C-@031
-@K1EJ@
D4C-@032
-@K1EJ@
Operating force OF max.
Release force RF min.
Pretravel PT max.
Overtravel OT min.
Movement Differential
MD max.
17.65 N
4.41 N
1.8 mm
3 mm
0.2 mm
17.65 N
4.41 N
1.8 mm
3 mm
0.2 mm
Operating Position
OP 24.9±1 mm 34.3±1 mm
OP
PT 16
2
1.4
1.5
7.5
4.0
8
23
XS2H-D421
2
34
Two, 5.1
+0.2
dia.
holes
Spot facing
10.2 dia. Depth: 6
0
10 dia. stainless
steel plunger
40 max.
49 max.
25±0.1
6 dia.
Rubber cap
S
ealed Pin Plunger
D4C-@031-@K1EJ@
D4C-@031-M1J@
OP
PT 16
2
7.5
4.0
8
23
2
34 1.4
1.5
XS2H-D421
Two, 5.1 +0.2 dia.
holes
Spot facing
10.2 dia. Depth: 6
0
40 max.
25±0.1
12 dia. x 4.4 stainless
sintered roller
6 dia.
49 max.
Rubber cap
S
ealed Roller Plunger
D4C-@032-@K1EJ@
D4C-@032-M1J@
16
38R
7
2
11.4
7.5
8
23
1.4
1.5
XS2H-D421
2
34
Two, 5.1
+0.2
dia.
holes
Spot facing
10.2 dia. Depth: 6
0
40 max.
25±0.1
102.7 max.
17.5 dia. x 7 stainless
sintered roller 50 max.
44±0.8
30.2±0.8
31.5±0.8
65 max.
6 dia.
M5 (length: 12)
Allen-head bolt
Roller Lever (High-sensitivity Model)
D4C-@024-@K1EJ@
D4C-@024-M1J@
Note: Specifications are the same for -M1J Switches
Operating
characteristics Model D4C-@024-@K1EJ@
Operating force OF max.
Release force RF min.
Pretravel PT
Overtravel OT min.
Movement Differential
MD max.
5.69 N
1.47 N
10°±3°
50°
3°
Operating Position
OP ---
13
D4C
Weather-resistant Models
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
* Operation characteristics for the D4C-@@27-P and D4C- @@29-P are for a lever length of 38 mm.
Safety Precautions
Refer to Safety Precautions for All Limit Switches.
Operating Environment
Seal material may deteriorate if a Switch is used outdoor or where
subject to special cutting oils, solvents, or chemicals. Always
appraise performance under actual application conditions and set
suitable maintenance and replacement periods.
Install Switches where they will not be directly subject to cutting
chips, dust, or dirt. The Actuator and Switch must also be protected
from the accumulation of cutting chips or sludge.
Constantly subjecting a Switch to vibration or shock can result in
wear, which can lead to contact interference with contacts,
operation failure, reduced durability, and other problems.
Excessive vibration or shock can lead to false contact operation or
damage. Install Switches in locations not subject to shock and
vibration and in orientations that will not produce resonance.
The Switches have physical contacts. Using them in environments
containing silicon gas will result in the formation of silicon oxide
(SiO2) due to arc energy. If silicon oxide accumulates on the
contacts, contact interference can occur. If silicon oil, silicon filling
agents, silicon cables, or other silicon products are present near the
Switch, suppress arcing with contact protective circuits (surge
killers) or remove the source of silicon gas.
Handling
The bottom of the Switch at the cable outlet is resin-molded. Secure
the cable at a point 5 cm from the Switch bottom to prevent exertion
of excess force on the cable.
When bending the cable, provide a bending radius of 45 mm min. so
as not to damage the cable insulation or sheath. Excessive bending
may cause fire or leakage current.
Connections
Be sure to connect a fuse with a breaking current 1.5 to 2 times
larger than the rated current to the Limit Switch in series in order to
protect the Limit Switch from damage due to short-circuiting.
When using the Limit Switch for the EN ratings, use the gI or gG 10-
A fuse.
Operating
characteristics
Model D4C-@@27-P D4C-@@29-P *
Operating force OF max.
Release force RF min.
Pretravel PT max.
Overtravel OT min.
Movement Differential
MD max.
5.69 N
1.47 N
25°
40°
3°
5.69 N
1.47 N
25°
40°
3°
Precautions for Correct Use
16
7
2
11.4
1.4
2
1.5
7.5
8
23
2
34
VCTF oil-resistant cable, 0.75 mm
2
,
4 conductor Finishing O.D.: 7.6 dia.
Two, 5.1 +0.2 dia. holes
Spot facing 10.2 dia. Depth: 6
0
40 max.
25±0.1
52.3±0.8
31.5±0.8
17.5 dia. x 7 stainless
sintered roller
30R to 75R (variable)
M5 (length: 16)
Allen-head bolt
M5 (length: 12)
Allen-head bolt
57.7 max.
65 max.
Adjustable Roller Lever
D4C-@@27-P
44
16
31.5
5.4
7
2
11.4
1.4 1.5
7.5
8
23
2
34
40 max.
25±0.1
3 dia. x 160 stainless
sintered roller
M5 (length: 16)
Allen-head bolt
M5 (length: 12)
Allen-head bolt
55 max.
65 max.
Two, 5.1 +0.2 dia. holes
Spot facing 10.2 dia.
Depth: 6
0
VCTF oil-resistant cable, 0.75 mm
2
,
4 conductor Finishing O.D.: 7.6 dia.
Adjustable Rod Lever
D4C-@@29-P
Not Suitable Suitable
Secure
here
5 cm
Bending radius
(R45 mm min.)
14
D4C
Operation
Operation method, shapes of cam and dog, operating frequency,
and overtravel have a significant effect on the service life and
precision of a Limit Switch. For this reason, the dog angle must be
30° max., the surface roughness of the dog must be 6.3 S min. and
hardness must be Hv 400 to 500.
To allow the plunger-type actuator to travel properly, adjust the dog
and cam to the proper setting positions. The proper position is
where the plunger groove fits the bushing top.
To allow the roller lever-type actuator to travel properly, adjust the
dog and cam so that the arrow head is positioned between the two
convex markers as shown below.
Indicator
Indicator-equipped switch has contacts and indicator in parallel.
When contacts are open, leakage current flows through the
indicator circuit and may cause load's malfunction.
Please check the load's OFF current before use the indicator-
equipped switch.
Mounting
A maximum of 6 Switches may be group-mounted. In this case, pay
attention to the mounting direction so that the convex part of the
group-mounting guide on one Switch fits into the concave part of
the guide on the other Switch as shown in the figure below. For
group mounting, the mounting panel must have a thickness (t) of
6 mm min.
If the mounting panel is warped or has protruding parts, a
malfunction may result. Make sure that the mounting panel is not
warped and has even surfaces.
Use a Switch with a rubber cap when using the plunger type in an
environment where malfunction is possible due to environmental
conditions such as dust or cutting chips which may not allow
resetting.
Do not expose the Switch to water exceeding 70°C or use it in
steam.
When the D4C is used in a circuit of a device to be exported to
Europe, classified as Overvoltage Class III as specified in IEC664,
provide a contact protection circuit.
Tighten each screw to a torque according to the following table.
Micro-load Models (D4C-4, -5, -6)
Micro-load models
can be used for
switching in the range
shown below.
2.8 mm
Dog
Bushing top
Groove 2.8 mm
Arrow head
Not correct
Correct
Convex
markers
Not correc
t
Correct
No. Type
Appropriate tightening torque*
1 M5 Allen-head bolt 4.90 to 5.88 N·m
2 M3.5 head mounting screw 0.78 to 0.88 N·m
3 M5 Allen-head bolt 4.90 to 5.88 N·m
Group-mounting guide
(Front: convex
Rear: concave)
Mounting panel
16 mm
Group-mounting guide
(Front: convex Rear: concave) t
Group Mounting
Two, 5.2-dia. or M5 screw holes
25±0.1
Mounting Holes
* By removing the two screws from
the head, the head direction can
be rotated 180°. After changing the
head direction, re-tighten to the
torque specified above. Be careful
not to allow any foreign substance
to enter the Switch.
30
24
12
5
01 10 100 1,0000.1
1 mA
26 mA0.16 mA
800 mW5 mW
100 mA 160 mA
Switching
range for
micro-load
models
Switching
range for
standard-
load
models
Switching
not possible
in this range
Current (mA)
Voltage (V)
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omrons exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omrons sole obligation hereunder shall be, at
Omrons election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omrons analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyers application or use of the Product. At Buyers request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyers application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the users programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omrons test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omrons Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omrons representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2018.5
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2018 All Right Reserved.