General Purpose Relays
Industrial Relays
KUEP Series Panel Plug-in Relay
12-2016, Rev. 1216
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
1
Potter & Brumfield
Coil Data
Coil voltage range 5 to 125VDC
6 to 240VAC
Coil insulation system according UL Class B
Coil versions, DC coil
Coil Rated Operate Coil Rated coil
code voltage voltage resistance power
VDC VDC Ω±10% W
One pole versions
5 5 3.75 21 1.2
6 6 4.5 32 1.125
12 12 9.0 120 1.2
24 24 18.0 472 1.25
48 48 36.0 1800 1.3
110 110 82.5 10000 1.25
125 125 93.75 13000 1.2
Two pole versions
5 5 3.75 14 1.8
6 6 4.5 20 1.8
12 12 9.0 80 1.8
24 24 18.0 320 1.8
48 48 36.0 1250 1.85
110 110 82.5 6720 1.8
125 125 93.75 8680 1.8
All figures are given for coil without preenergization, at ambient temperature +23°C.
Coil versions, AC coil
Coil Rated Operate Coil Rated coil
code voltage voltage resistance power
VAC VAC Ω±15% VA
One pole versions
6 6 5.1 6 2.0
12 12 10.2 24 2.0
24 24 20.4 85 2.0
120 120 102.0 2250 2.1
240 240 204.0 9110 2.1
Two pole versions
6 6 5.1 4.2 2.8
12 12 10.2 18 2.8
24 24 20.4 72 2.8
120 120 102.0 1700 2.9
240 240 204.0 7200 2.9
All figures are given for coil without preenergization, at ambient temperature +23°C.
Insulation Data
Initial dielectric strength
between open contacts 1200Vrms
between contact and coil 2200Vrms
between adjacent contacts 2200Vrms
Initial insulation resistance
between insulated elements 100MΩ
n 1 Form X, 2 Form A and 2 Form C contact arrangements
n 10 amp current rating
n Magnetic blow-out
n Various mounting options
n Indicator lamp available
Typical applications
DC load switching in industrial controls
Approvals
UL E22575; CSA LR15734; CE (KUEP-11 only)
Technical data of approved types on request
Contact Data
Contact arrangement
1 form X (NO-DM), 2 form A (NO), 2 form C (CO)
Rated voltage 150VDC
Rated current 10A
Contact material AgCdO AgSnOInO
Min. recommended contact load 300mA, 12VDC
Frequency of operation 360 ops./hour 360 ops./hour
Operate/releases time max. 15/10ms
Bounce time max. 17ms
Contact ratings
Type Load Cycles
UL 508
KUEP, 1 form X, AgCdO
10A, 150VDC 100x103
1A, 300VDC 100x103
2.5 A, 170 VDC, resistive 100x103
KUEP, 2 form A, AgCdO
5 A, 150 VDC
2.5 A, 170 VDC, resistive 100x103
KUEP, 2 form C, AgCdO
3 A, 150 VDC
2.5 A, 170 VDC, resistive 100x103
10 A, 240 VAC
10 A, 32 VDC
5 FLA, 15 LRA, 250 VAC
1/3 HP, 120 VAC
5 A, 120 VAC, tungsten
1/2 HP, 250 VAC
10 FLA, 40 LRA, 125 VAC
3 A, 600 VAC
1/2 HP, 480 VAC
1/2 HP, 600 VAC
1 HP, 480 VAC, 3 phase
KUEP, 1 form X, AgSnOInO
10A, 150VDC, resistive 30x103
KUEP, 2 form A, AgSnOInO
5 A, 150 VDC, resistive 100x103
KUEP, 2 form C, AgSnOInO
3 A, 150 VDC, resistive 100x103
Mechanical endurance 10x106 ops.