SF4D
2ds_61407_en_sf4d: 130312D
COIL DATA
ELECTRICAL LIFE
REFERENCE DATA
Part number Coil nominal voltage
V DC
Operate voltage
V DC
Release voltage
V DC
Coil resistance
(10%, 20°C)
Coil inductance
(mH)
SF4D-DC5V 5 3.75 0.75 50 47
SF4D-DC9V 9 6.75 1.35 162 145
SF4D-DC12V 12 9.00 1.80 288 252
SF4D-DC18V 18 13.50 2.70 648 551
SF4D-DC21V 21 15.75 3.15 882 742
SF4D-DC24V 24 18.00 3.60 1152 959
SF4D-DC36V 36 27.00 5.40 2592 2097
SF4D-DC48V 48 36.00 7.20 4608 3654
SF4D-DC60V 60 45.00 9.00 7200 5612
Voltage Current Load type Frequency Duty cycle No. of contacts No. of ops.
230V AC 8A AC 1 0.25Hz 25% 4*2 85,000*5
250V AC 6A AC 1 0.33Hz 50% 4*2 / 8*3 100,000*5
230V AC 6A AC 1 0.33Hz 10% 2*3 200,000*4,*5
230V AC 30 / 3A AC 15*1 0.33Hz 10% 1*3 200,000*4,*5
24V DC 8A DC 1 0.33Hz 10% 2*3 200,000*4,*5
24V DC 3A DC 13*1 0.33Hz 10% 1*3 50,000*4,*5
24V DC 3A L/R = 40ms 0.33Hz 10% 1*3 100,000*4,*5
*1 EN 60947-5-1: 1997; table C.1
*2 Breathing hole closed
*3 Breathing hole open
*4 Ambient temperature +70°C
*5 Dielectric strength according to EN61810-1:2004.
Coil voltage characteristicsLoad limit curve
-50 -40 -30 -20 -10 0 10 20 807060504030 10090 110
Ambient temperature °C
0.1
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
1.0
1.7
1.6
1.5
1.4
1.3
1.2
1.1
Ucoil / Ucoil rated
Permissible coil
voltage without
contact load
(nominal coil
resistance)
Minor increase due to
temperature compensation
Average value of pick-up voltage
without previous coil heating
Permissible coil voltage
with contact load of 4 x 6A
(nominal coil resistance)
Average value of drop-out voltage
without previous coil heating
Loads in the range under the curve can be switched safely.
The arc will extinguish before the opposite contact makes.
Permissable coil voltages and pick-up and drop-out
characteristics at various ambient temperatures.