Specifications LCE
Options AC/DC24V AC90-250V
Rated Voltage AC/DC24V (50-60 Hz) AC90-250V (50-60 Hz)
Input Voltage Operating Voltage Rated Voltage + or - 10%
Operating temperature Range -25OC ~ +60OC
Relative Humidity Less than 90%
Flashing Cycle (“FB” styles only) 60 + or – 12 flashes per minute
Alarm Sound Level (“FB” styles only) Max: 85 + or – 4dB (at 1m) Min: 70 + or – 4dB (at 1m)
Alarm Sound Description (“FB” styles only) Intermittent, single-tone; Alarm 1: fast beep, Alarm 2: slow beep
Mounting Location Options Indoor use only
Mounting Direction Options Upright only
Protection Rating (LCE-W) IP-65
Protection Rating (LCE, LCE-FB, LCE-FBW) IP-54
Vibration 19.6m/s2 (30Hz) (2 hours each: front-back, right-left, up-down)
Insulation Resistance More than 1 Megohm between terminals and chassis at DC500V
Withstand Voltage (AC/DC24V) AC500V applied between terminals and chassis for 1 minute without breaking insulation
Dielectric Voltage (AC90-250V) AC1500V applied between terminals and chassis for 1 minute without breaking insulation
Red Amber Green Blue Clear
Luminous Intensity
(mcd = millicandela) 760mdc 830mcd 1290mcd 210mcd 400mcd
CE EN60958-1: 1993
UL UL Component Recognition per UL-508 (File No. E215660)
Applicable Standards RoHS RoHS Directive 2005/95/EC
Power Consumption Red Amber Green Blue Clear Steady Inrush Steady Inrush
Current (mA @ 24V) 28 28 22 23 23 40 250 40 250
AC/DC24V Watts 0.7 0.7 0.6 0.6 0.6 1.0 ----- 1.0 -----
Watts (@AC120V) 1.6 1.6 1.5 1.5 1.5 1.6 ----- 1.6 -----
Watts (@AC240V) 2.0 2.0 1.9 1.9 1.9 2.0 ----- 2.0 -----
AC90-250V Standby Power 0.8W @ AC120V 1.1W @ AC240V
Contact Capacity (IS = current capacity; VS = withstand voltage; VC = dielectric breakdown voltage; IL = leakage current)
Contact Capacity Transistor Capacity (NPN and PNP)
LED Light Module IS >= 100mA; VS >= AC35V IC >= 100mA; VC >= 35V
Alarm IS >= 300mA; VS >= AC35V IC >= 300mA; VC >= 35V
AC/DC24V
Power Supply IS >= 500mA; VS >= AC35V
Contact Capacity Transistor Capacity (NPN)
LED Light Module (Signal wire) IS >= 100mA; VS >= AC35V IC >= 100mA; VC >= 35V
Alarm (Signal wire) IS >= 10mA; VS >= AC35V IC >= 200mA; VC >= 35V
Power Supply IS >25A
AC90-250V
Power Supply Inrush IS >= 10A @ AC100; IS >= 25A @ AC250V (200µsec)
Leakage Current IL = 0.1mA or less
Fuse (not included) 1A (250V)