ISOLATED DC/DC CONVERTERS 48 Vdc Input, 12 Vdc/8.35 A, 5 Vdc/20 A, 3.3 Vdc/25 A, 1.2-2.5 Vdc/30 A Outputs 0RQB-C0U Series RoHS Compliant PRELIMINARY Rev.A * Isolated * Output Over Voltage Shutdown * High Efficiency * OCP/SCP * High Power Density * Over Temperature Protection * Low Cost * Remote On/Off * Input Under Voltage Lockout * Output Voltage Trim * Fixed Frequency (285 kHz) * Positive/Negative Remote Sense * Input Over Voltage Lockout * Basic Isolation * Active Low/High (Option) * Safety Approval to UL60950-1 (UL/cUL) Description The 0RQB-C0U Series are isolated dc/dc converters that operate from a nominal 48 Vdc source. These units will provide up to 100 W of output power from a nominal 48 Vdc input. These units are designed to be highly efficient and low cost. Typical efficiency of 12 Vdc output at 48 Vdc input at full load is 91%. Features include remote on/off, over current protection and under-voltage lockout. These converters are provided in an industry standard quarter brick package. Part Selection Output Voltage Input Voltage Max. Output Current Max. Output Power Typical Efficiency Model Number Active High Model Number Active Low 12 Vdc 18 Vdc - 75 Vdc 8.35 A 100 W 91% 0RQB-C0U120 0RQB-C0U12L 5.0 Vdc 18 Vdc - 75 Vdc 20 A 100 W 90% 0RQB-C0U050 0RQB-C0U05L 3.3 Vdc 18 Vdc - 75 Vdc 25 A 82.5 W 90% 0RQB-C0U033 0RQB-C0U03L 2.5 Vdc 18 Vdc - 75 Vdc 30 A 75 W 89.5% 0RQB-C0U025 0RQB-C0U02L 1.8 Vdc 18 Vdc - 75 Vdc 30 A 54 W 85% 0RQB-C0UV80 0RQB-C0UV8L 1.5 Vdc 18 Vdc - 75 Vdc 30 A 45 W 83% 0RQB-C0UV50 0RQB-C0UV5L 1.2 Vdc 18 Vdc - 75 Vdc 30 A 36 W 80% 0RQB-C0UV20 0RQB-C0UV2L Notes: 1. Add "G" suffix at the end of the model number to indicate Tray Packaging. 2. All part numbers above indicate RoHS 6. Change the second letter "R" to "7" for RoHS 5 part numbers. Absolute Maximum Ratings Parameter Min Typ Max -0.3 V - 80 V No Operating - - 75 V Operating -0.3 V - 18 V - - 2000 V Ambient Temperature -40 C - 85 C Storage Temperature -55 C - 125 C Input Voltage (continuous) Remote On/Off I/O Isolation Voltage Notes Note: All specifications are typical at nominal input, full load at 25 C unless noted. Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 * Tel 201-432-0463 * Fax 201-432-9542 * www.belfuse.com ISOLATED DC/DC CONVERTERS 48 Vdc Input, 12 Vdc/8.35 A, 5 Vdc/20 A, 3.3 Vdc/25 A, 1.2-2.5 Vdc/30 A Outputs Input Specifications Parameter Input Voltage Input Current (full load) VO=12 V VO=5.0 V VO=3.3 V VO=2.5 V VO=1.8 V VO=1.5 V VO=1.2 V Input Current (no load) Min 18 V Typ 48 V Max 75 V - 100 mA 7.0 A 7.0 A 6.0 A 5.5 A 4.0 A 3.5 A 3.0 A 180 mA 10 mA 15 mA Remote Off Input Current Input Reflected Ripple Current (pk-pk) - 20 mA 40 mA Input Reflected Ripple Current (rms) - 5 mA 10 mA - 0.05 A s 2 0.1 A s Turn-on Voltage Threshold 16.5 V 17.0 V 17.5 V Turn-off Voltage Threshold 15.5 V 16.0 V 16.5 V Input over voltage Lockout 76 V 78 V 80 V 2 I t Inrush Current Transient Notes Tested with simulated source impedance of 10 uH, 5 Hz to 20 MHz BW; use a 0.47 uf/100 V ceramic cap and a 100 uF /100 V electrolytic cap with ESR = 1 ohm max. at 200 kHz at 25 C. 2 Note: All specifications are typical at nominal input, full load at 25 C unless noted. Output Specifications Parameter Output Voltage Set Point Min Typ Max 11.820 V 4.925 V 3.251 V 2.455 V 1.773 V 1.448 V 1.182 V 12.00 V 5.00 V 3.30 V 2.50 V 1.80 V 1.50 V 1.20 V 12.180 V 5.075 V 3.360 V 2.545 V 1.827 V 1.523 V 1.218 V VO=12 V VO=5.0 V VO=3.3 V VO=2.5 V VO=1.2 V-1.8 V - 24 mV 10 mV 4 mV 4 mV 3 mV 120 mV 25 mV 15 mV 10 mV 6 mV VO=12 V VO=5.0 V VO=3.3 V -2.5 V VO=1.2 V -1.8 V - 30 mV 10 mV 8 mV 5 mV 80 mV 25 mV 15 mV 10 mV VO=12 V VO=5.0 V VO=3.3 V VO=2.5 V VO=1.8 V-1.2 V - 60 mV 40 mV 30 mV 20 mV 15 mV 100 mV 65 mV 50 mV 50 mV 30 mV VO=12 V VO=5.0 V VO=3.3 V VO=2.5 V VO=1.8 V VO=1.5 V VO=1.2 V Line Regulation Load Regulation Regulation Over Temperature (-40 C to +85 C) Notes Vin=48 V, Io=50% full load Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 * Tel 201-432-0463 * Fax 201-432-9542 * www.belfuse.com ISOLATED DC/DC CONVERTERS 48 Vdc Input, 12 Vdc/8.35 A, 5 Vdc/20 A, 3.3 Vdc/25 A, 1.2-2.5 Vdc/30 A Outputs Output Specifications (continued) Parameter Output Current Range Min Typ Max VO=12 V VO=5.0 V VO=3.3 V VO=1.2 V -2.5 V 0A 0A 0A 0A - 8.35 A 20 A 25 A 30 A VO=12 V VO=5.0 V VO=3.3 V VO=2.5 V VO=1.2 V -1.8 V 9.2 A 24 A 27 A 35 A - 10.5 A 26 A 32 A 40 A 36 A 13 A 30 A 35 A 45 A - - 3A s 5A s - 30 mV 25 mV 20 mV 15 mV 50 mV 40 mV 40 mV 30 mV - 25 mV 20 mV 15 mV 10 mV 40 mV 30 mV 25 mV 20 mV - 100 mV 75 mV 50 mV 40 mV 150 mV 120 mV 100 mV 80 mV 10 mS 75 mV 50 mV 35 mV 30mV 25 mV - 120 mV 100 mV 70 mV 60 mV 50 mV 100 mS - 0% 5% 0 uF 0 uF 0 uF 0 uF - 1200 uF 6800 uF 15000 uF 20000 uF - 360 mV 100 uS 360 mV 150 uS 200 mV 100 uS 200 mV 100 uS 150 mV 100 uS 150 mV 100 uS 480 mV 250 uS 480mV 250 uS 300 mV 150 uS 300 mV 150 uS 200 mV 100 uS 200 mV 100 uS Notes Current Limit Threshold Short Circuit Surge Transient 2 2 Vin=48 V ; Ripple and Noise (rms) VO=12 V VO=5.0 V VO=3.3 V -2.5 V VO=1.2 V -1.8 V Vin=24 V ; Ripple and Noise (rms) VO=12 V VO=5.0 V VO=3.3 V VO=1.2 V -2.5 V Vin=48 V ; Ripple and Noise (pk-pk) VO=12 V VO=5.0 V VO=3.3 V-2.5 V VO=1.2 V-1.8 V Vin=24 V ; Ripple and Noise (pk-pk) VO=12 V VO=5.0 V VO=3.3 V VO=2.5 V VO=1.2 V-1.8 V Turn on Time Overshoot at Turn on Output Capacitance VO=12.0 V VO=5.0 V VO=3.3 V VO=1.2 V-2.5 V Test conditions: 0-20 MHz BW, with a 1 uF ceramic capacitor and a 10 uF Tantalum capacitor at the output. Transient Response 50% ~ 75% Max Load 75% ~ 50% Max Load 50% ~ 75% Max Load 75% ~ 50% Max Load 50% ~ 75% Max Load 75% ~ 50% Max Load Overshoot Settling Time Overshoot Settling Time Overshoot Settling Time Overshoot Settling Time Overshoot Settling Time Overshoot Settling Time VO=12.0 V VO=5.0 V VO=3.3 V Test conditions: di/dt = 0.1 A/uS, Vin=48 V, with a 1 uF ceramic capacitor and a 10 uF Tantalum capacitor at the output. Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 * Tel 201-432-0463 * Fax 201-432-9542 * www.belfuse.com ISOLATED DC/DC CONVERTERS 48 Vdc Input, 12 Vdc/8.35 A, 5 Vdc/20 A, 3.3 Vdc/25 A, 1.2-2.5 Vdc/30 A Outputs Output Specifications (continued) Parameter Transient Response Overshoot 50% ~ 75% Max Load Settling Time Overshoot 75% ~ 50% Max Load Settling Time Overshoot 50% ~ 75% Max Load Settling Time Overshoot 75% ~ 50% Max Load Settling Time VO=2.5 V, VO=1.2 V-1.8 V Min Typ Max Notes - 150 mV 85 uS 150 mV 85 uS 50 mV 100 uS 50 mV 100 uS 200 mV 100 uS 200 mV 100 uS 80 mV 150 uS 80 mV 150 uS Test conditions: di/dt = 0.1 A/uS, Vin=48 V, with a 1 uF ceramic capacitor and a 10 uF Tantalum capacitor at the output. Note: All specifications are typical at nominal input, full load at 25 C unless noted. General Specifications Parameter Min Typ Max VO=12 V VO=5.0 V VO=3.3 V VO=2.5 V VO=1.8 V VO=1.5 V VO=1.2 V 88% 88% 88% 88% - 91% 90% 90% 89.5% 85% 83% 80% - VO=12 V VO=5.0 V VO=3.3 V VO=2.5 V VO=1.8 V VO=1.5 V VO=1.2 V 89% 240 kHz 92% 91% 91% 87% 85% 83% 80% 285 kHz 320 kHz Isolation capacitance - 1500 pF - Input to Output Isolation Voltage - - 2000 V Remote Sense Compesation - - 10% Vo Output Voltage Trim Range 80% Vo - 110% Vo Notes Efficiency Vin=48 V, full load , Ta=25 C Efficiency Switching Frequency Over Temperature Protection - 125 C - Over Voltage Protection - 130% Vo - MTBF Vin=24 V, full load , Ta=25 C The total voltage increased by trim and remote sense should not exceed 10%Vo. Vin=48V, full load, Hiccup mode Calculated Per Bell Core SR-332 (IO = Nominal; Ta = 25 C) TBD Dimensions Inches millimeters Weight - 2.30 x 1.45 x 0.395 58.42 x 36.83 x 10.03 40 g - Note: All specifications are typical at nominal input, full load at 25 C unless noted. Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 * Tel 201-432-0463 * Fax 201-432-9542 * www.belfuse.com ISOLATED DC/DC CONVERTERS 48 Vdc Input, 12 Vdc/8.35 A, 5 Vdc/20 A, 3.3 Vdc/25 A, 1.2-2.5 Vdc/30 A Outputs Control Specifications Parameter Min Typ Max Notes -0.3 V - 0.8 V 2.4 V - 18 V -0.3 V - 0.8 V 2.4 V - 18 V 0 mA - 0.75 mA Remote On/Off Signal Low (Unit On) Signal High (Unit Off) Signal Low (Unit Off) Signal High (Unit On) Active Low Active High Current Sink 0RQB-C0UxxL. The remote on/off pin open, Unit off. 0RQB-C0Uxx0. The remote on/off pin open, Unit on. Output Trim Equations Equations for calculating the trim resistor are shown below (Unit: k). The Trim Down resistor should be connected between the Trim pin and Ground pin. The Trim Up resistor should be connected between the Trim pin and the Vout. Only one of the resistors should be used for any given application. 1) For Vo=1.5 V - 12 V: Rtrimdown = Rtrimup = 511 - 10.22 delta Vout Module Trim GND (100 + delta ) Vo 5.11 - 626 - 10.22 1.225 delta Rtrimdown Vout Module Trim Rtrimup 2) For Vo=1.2 V: GND 511 Rtrimdown = - 10.22 delta Rtrimup = Notes: delta = (100 + delta ) Vo 5.11 - 313 - 10.22 0.6125 delta (Vo _ req - Vo) x100[%] Vo Vo_req=Desired (trimmed) output voltage [V]; Vo=output voltage Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 * Tel 201-432-0463 * Fax 201-432-9542 * www.belfuse.com ISOLATED DC/DC CONVERTERS 48 Vdc Input, 12 Vdc/8.35 A, 5 Vdc/20 A, 3.3 Vdc/25 A, 1.2-2.5 Vdc/30 A Outputs Efficiency Data 95% 18 V EFFICIENCY 85% 24V 75% 48 V 75 V 65% 1 EFFICIENCY 95.0% 55% 85.0% 18 V 24V 48 V 75 V 75.0% 65.0% 55.0% 45.0% 45% 3A 7.5A 15A 22.5A 2.5 30A 6.25 18.75 25 OUTPUT CURRENT (A) OUTPUT CURRENT (A) Vo=2.5 V Vo=3.3 V 95% 95% 90% 18 V 24V 48 V 75 V 85% 80% EFFICIENCY 90% EFFICIENCY 12.5 18 V 24V 48 V 75 V 85% 80% 75% 75% 70% 2A 5A 10A 15A OUTPUT CURRENT (A) Vo=5.0 V 20A 70% 0.83A 2.075A 4.15A 6.225A 8.3A OUTPUT CURRENT (A) Vo=12 V Thermal Derating Curves Vo=2.5 V, Vin=48 V Vo=3.3 V, Vin=48 V Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 * Tel 201-432-0463 * Fax 201-432-9542 * www.belfuse.com ISOLATED DC/DC CONVERTERS 48 Vdc Input, 12 Vdc/8.35 A, 5 Vdc/20 A, 3.3 Vdc/25 A, 1.2-2.5 Vdc/30 A Outputs Thermal Derating Curves (continued) Vo=5.0 V, Vin=48 V Vo=12 V, Vin=48 V Ripple and Noise Waveforms 2.5 V/30 A output 3.3 V/25 A output Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 * Tel 201-432-0463 * Fax 201-432-9542 * www.belfuse.com ISOLATED DC/DC CONVERTERS 48 Vdc Input, 12 Vdc/8.35 A, 5 Vdc/20 A, 3.3 Vdc/25 A, 1.2-2.5 Vdc/30 A Outputs Ripple and Noise Waveforms (continued) 5.0 V/20 A output 12 V/8.35 A output Note: Ripple and noise at full load, 48 V input, with a 1 uF ceramic capacitor and a 10 uF tantalum capacitor at the output, and Ta=25 deg C. Transient Response Waveforms Vout= 2.5 V 50%-75% Load Transients at Vin=48 V Vout= 2.5 V 75%-50% Load Transients at Vin=48 V Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 * Tel 201-432-0463 * Fax 201-432-9542 * www.belfuse.com ISOLATED DC/DC CONVERTERS 48 Vdc Input, 12 Vdc/8.35 A, 5 Vdc/20 A, 3.3 Vdc/25 A, 1.2-2.5 Vdc/30 A Outputs Transient Response Waveforms (continued) Vout= 3.3 V 50%-75% Load Transients at Vin=48 V Vout= 3.3 V 75%-50% Load Transients at Vin=48 V Vout= 5.0 V 50%-75% Load Transients at Vin=48 V Vout= 5.0 V 75%-50% Load Transients at Vin=48 V Vout= 12 V 50%-75% Load Transients at Vin=48 V Vout= 12 V 75%-50% Load Transients at Vin=48 V Note: Transients at di/dt = 0.1 A/uS, Vin=48 V, with a 1 uF ceramic capacitor and a 10 uF Tantalum capacitor at the output, Ta=25 deg C. Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 * Tel 201-432-0463 * Fax 201-432-9542 * www.belfuse.com ISOLATED DC/DC CONVERTERS 48 Vdc Input, 12 Vdc/8.35 A, 5 Vdc/20 A, 3.3 Vdc/25 A, 1.2-2.5 Vdc/30 A Outputs Mechanical Outline Pin Connections Pin 1 2 3 4 5 6 7 8 Function Vin (+) Remote On/Off Vin (-) Vout (-) Remote Sense (-) Trim Remote Sense (+) Vout (+) Pin Size 0.04" 0.04" 0.04" 0.062" 0.04" 0.04" 0.04" 0.062" RoHS Compliance Complies with the European Directive 2002/95/EC, calling for the elimination of lead and other hazardous substances from electronic products. (c)2007 Bel Fuse Inc. Specifications subject to change without notice. 030307 CORPORATE FAR EAST EUROPE Bel Fuse Inc. 206 Van Vorst Street Jersey City, NJ 07302 Tel 201-432-0463 Fax 201-432-9542 www.belfuse.com Bel Fuse Ltd. 8F/ 8 Luk Hop Street San Po Kong Kowloon, Hong Kong Tel 852-2328-5515 Fax 852-2352-3706 www.belfuse.com Bel Fuse Europe Ltd. Preston Technology Management Centre Marsh Lane, Suite G7, Preston Lancashire, PR1 8UD, U.K. Tel 44-1772-556601 Fax 44-1772-888366 www.belfuse.com