FR2
www.clare.com Rev. 2
Specifications
All parameters are at 25°C unless otherwise stated.
Absolute Maximum Ratings are stress ratings. Stresses
in excess of these ratings can cause permanent damage
to the device. Functional operation of the device at these
or any other conditions beyond those indicated in the
operational sections of this data sheet is not implied.
Exposure of the device to the absolute maximum ratings
for extended period may degrade the device and effect
its reliability.
Ratings (@ 25˚ C)
PARAMETER CONDITIONS SYMBOL MIN TYP MAX UNITS
Contact Ratings
Operate ampere turns range Full Blade Tolerance = ± 1.5NI AT 10 - 30 NI
Release ampere turns range Full Blade Tolerance = ± 1.5NI AT 5 - 30 NI
Switching Voltage Max DC/PeakAC Resistive VL- - 200 VDC
Switching Current Max DC/PeakAC Resistive IL- - 500 mAmps
Carry Current Max DC/PeakAC Resistive IC- - 1.5 Amps
Contact Rating Max DC/PeakAC Resistive - - - 10 VA
Life Expectancy 1V, 10mA Signal Level - - 1000 - x106 Ops
10V, 10mA Low Level - - 500 - x106 Ops
50V, 100mA Telecom Load - - 2 - x106Ops
100V, 100mA Rated Loads - - 2 - x106 Ops
Static Contact Resistance 50mV, 10mA(1) CR - 80 150 mΩ
Contact Material - - Ru - -
Switch Specifications
Insulation Resistance(2) 100V, 25°C, 40% RH IR 1091011 -Ω
Capacitance Across Open Contacts - - 0.3 - pF
Dielectric Strength(5) Between Contacts - 250 300 - VDC/Peak AC
Operate Time, At nominal coil voltage, TOP - - 0.5 ms
including bounce 10Hz Square Wave
Release Time Zener-Diode Suppression(3) TREL - - 0.2 ms
Environmental Ratings
Storage Temperature TA-40 - +125 °C
Operating Temperature TO-40 - +125 °C
Soldering Temperature - - - +240 °C
Vibration Resistance 5Hz - 200Hz G - - 20 Gs
Shock Resistance 11±1ms, 1/2 Sine Wave S - - 100 Gs
Weight - - 0.13 - grams/unit
Parameter Min Typ Max Units
Switching Voltage
FR2 - DYAD®200 Volts
Switching Current
FR2 - DYAD®0.5 Amps
Carry Current
FR2 - DYAD®1.5 Amps
Switching Frequency
FR2 - DYAD®500 Hz
Contact Resistance
FR2 - DYAD®150 mΩ
(See detailed specifications for more information.)
(1) Contact resistance measured with 4 terminal method, 1.1" between test leads
(2) >1012 Ω is available upon request
(3) A 24V zener in series with a diode across the coil
(4) Use caution not to exceed vibration resistance limits while ultrasonically cleaning. Contact Clare Engineering for more details/recommendations
(5) 15 ampere turn minimum
Dyad®
2