DC/DC Converter
CF0505XT-1WR3
2019.10.18-A/4 Page 1 of 4
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
1W isolated DC-DC converter
Fixed input voltage, unregulated single output
Patent Protection RoHS
FEATURES
Continuous short-circuit protection
Operating ambient temperature range: -40to
+105
Compact SMD package
I/O isolation test voltage 3.5k VDC
Industry standard pin-out
Meet AEC-Q100 standards
Production process meets IATF16949 system
EN62368 approved
The CF0505XT-1WR3 is designed for application where isolated output is required from a distributed power system. It can be used in
automobile motor control and drive system. Such as motor vehicle communication system controller, engine control system, the ignition
system, the motor voltage monitoring, the electronic accelerator pedal, automobile tire pressure detection system, doors and tail lights
controller, air conditioning control and battery management system (BMS), etc.
Selection Guide
Certification
Part No.
Input Voltage (VDC)
Output
Full Load
Efficiency (%)
Min./Typ.
Nominal
(Range)
Voltage
(VDC)
Current (mA)
Max./Min.
CE
CF0505XT-1WR3
5
(4.5-5.5)
5
200/20
78/82
Input Specifications
Item
Operating Conditions
Min.
Typ.
Max.
Unit
Input Current
(full load / no-load)
5VDC input
--
244/5
257/10
mA
Reflected Ripple Current*
--
15
--
mA
Surge Voltage (1sec. max.)
-0.7
--
9
VDC
Input Filter
Capacitance filter
Hot Plug
Unavailable
Note: * Reflected ripple current testing method please see DC-DC Converter Application Notes for specific operation.
Output Specifications
Item
Operating Conditions
Min.
Typ.
Max.
Unit
Voltage Accuracy
See output regulation curve(Fig. 1)
Linear Regulation
Input voltage change: ±1%
--
--
1.2
%/%
Load Regulation
10%-100% load
--
10
15
%
Ripple & Noise*
20MHz bandwidth
--
30
70
mVp-p
Temperature Coefficient
Full load
--
±0.02
--
%/
Short-circuit Protection
Continuous, self-recovery
Note:* The “parallel cable” method is used for Ripple and Noise test, please refer to DC-DC Converter Application Notes for specific information.
General Specifications
Item
Operating Conditions
Min.
Typ.
Max.
Unit
Isolation
Input-output Electric Strength Test for 1 minute with a
leakage current of 1mA max.
3500
--
--
VDC
Insulation Resistance
Input-output resistance at 500VDC
1000
--
--
MΩ
Isolation Capacitance
Input-output capacitance at 100kHz/0.1V
--
20
--
pF
Operating Temperature
Derating when operating temperature85, (see
Fig. 2)
-40
--
105
Storage Temperature
-55
--
125
Case Temperature Rise
Ta=25
--
15
--
Storage Humidity
Non-condensing
--
--
95
%RH
DC/DC Converter
CF0505XT-1WR3
2019.10.18-A/4 Page 2 of 4
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Reflow Soldering Temperature*
Peak temp.245, maximum duration time60s
over 217
Switching Frequency
Full load, nominal input voltage
--
270
--
KHz
MTBF
MIL-HDBK-217F@25
3500
--
--
K hours
Vibration
10-1000Hz, 1mm, 10G, along X, Y and Z (4 cycles)
Moisture Sensitivity Level (MSL)
IPC/JEDEC J-STD-020D.1
Level 1
Note: * For actual application, please refer to IPC/JEDEC J-STD-020D.1.
Mechanical Specifications
Case Material
Black plastic; flame-retardant and heat-resistant (UL94-V0)
Dimensions
13.20 x 11.40 x 7.25 mm
Weight
1.4g(Typ.)
Cooling Method
Free air convection
Electromagnetic Compatibility (EMC)
Emissions
CE
CISPR25/EN55025 CLASS 1 (see Fig. 4 for recommended circuit)
RE
CISPR25/EN55025 CLASS 1 (see Fig. 4 for recommended circuit)
Immunity
ESD
ISO10605 Air ±8kV , Contact ±4kV perf. Criteria B
Typical Characteristic Curves
Fig. 1
120
100
80
60
40
20
0
-40 040 85 105
Output Power Percentage(%)
Ambient Temperature( )
Safe Operating Area
Temperature Derating Graph
Fig. 2
Design Reference
1. Typical application circuit
Input and/or output ripple can be further reduced, by connecting a filter capacitor from the input and/or output terminals to ground as
shown in Fig.3.
Choosing suitable filter capacitor values is very important for a smooth operation of the modules, particularly to avoid start-up problems
caused by capacitor values that are too high. For recommended input and output capacitor values refer to Table 1.
DC/DC Converter
CF0505XT-1WR3
2019.10.18-A/4 Page 3 of 4
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Vin
GND
+Vo
0V
DC
Cin
DC
Cout
Fig.3
Recommended capacitive load value table (Table 1)
Vin(VDC)
Cin(µF)
Vo (VDC)
Cout(µF)
5
4.7
5
10
2. EMC solution-recommended circuit
Fig. 4
EMC recommended circuit value table (Table 2)
EMI
Input voltage(VDC)
5
C1/C2
4.7µF /25V
C3
10µF
LDM
6.8µH
3. Output load requirements
For a reliable and efficient operation of the converter, the minimum load should never be less than 10% of the rated output load. If the total
required output power is below 10%, a parallel bleeding resistor is required on the output (The sum of the efficient power and resistor
consumption power is not less than 10%).
4. For additional information, please refer to DC-DC converter application notes on
www.mornsun-power.com
Dimensions and Recommended Layout
DC/DC Converter
CF0505XT-1WR3
2019.10.18-A/4 Page 4 of 4
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Notes:
1. For additional information on Product Packaging please refer to www.mornsun-power.com. Tube Packaging bag number: 58210024, Roll
Packaging bag number: 58200054;
2. If the product is not operated within the required load range, the product performance cannot be guaranteed to comply with all
parameters in the datasheet;
3. The maximum capacitive load offered were tested at input voltage range and full load;
4. Unless otherwise specified, parameters in this datasheet were measured under the conditions of Ta=25, humidity<75%RH with nominal
input voltage and rated output load;
5. About the AEC-Q100 specific test project, please contact our technicians directly for specific information;
6. All index testing methods in this datasheet are based on our company corporate standards;
7. We can provide product customization service, please contact our technicians directly for specific information;
8. Products are related to laws and regulations: see "Features" and "EMC";
9. Our products shall be classified according to ISO14001 and related environmental laws and regulations, and shall be handled by
qualified units.
MORNSUN Guangzhou Science & Technology Co., Ltd.
Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Huangpu District, Guangzhou, P. R. China
Tel: 86-20-38601850 Fax: 86-20-38601272 E-mail: info@mornsun.cn www.mornsun-power.com