D-4
1 of 4 Rev 05/09/12
Specications subject to change without notice
©2012 Deltrol Controls - A Division of Deltrol Corp.
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
Deltrol
CONTROLS
D
C
D-FRAME SOLENOID
Electrical Specications
Coil Voltages 6, 12, 24, 120, 240 VAC | 6, 12, 24, 110 VDC
Coil Power 10 VA Continuous, 59 VA Intermittent, 100 VA Pulse,
11.5 Watts Continuous, 47 Watts Intermittent, 105 Watts Pulse
Coil Termination
0.187” [4.7] Quick Connect Terminals (standard)
0.250” [6.4] Quick Connect Terminals (optional)
Wire leads optional with tape wrapped coil
Duty Cycle Continuous, Intermittent and pulse (see standard part numbers on page 4)
Coil Treatment Encapsulated (tape wrap optional)
Insulation Class Class A Rating - 105ºC (221ºF) Max. (standard)
Class F Rating - 155ºC (311ºF) Max. (optional)
Dielectric Strength 30 Volts and Under: 500 VRMS
Over 30 Volts: 1000 VRMS plus 2X rated voltage for 1 minute
Mechanical Specications
Size 1.996” [50.7] (L) x 1.437” [36.5] (W) x 1.625” [41.3] (H) (See dimensional drawing on page 2)
Forces See page 3 for force curves
Plunger Diameter Ø 0.4375” [11.1]
Plunger Guide Material Plastic
Mounting 8X #8-32 UNC-2B Mounting Holes
Weight Plunger - 1.6 oz [45.4 gms], Total - 12.0 oz [340.2 gms]
Life Expectancy 250,000 Cycles (Dependent on load conditions)
Agency Approval
UL File No. E57982 For Continuous Duty
UL File No. E74443 For Insulation Systems
S105, S130, S130D, S130D1, S155D
Two position linear solenoid with D-frame construction.
Features
• Balance of cost and performance
• AC solenoids and DC solenoids available
• Encapsulated coils on most models
• UL approval on many models
Dimensions: inches [mm]