TH13*TH23 TH13*TH23 HOUR METER 52 2.047 Replacing the TH13/23 series unit with the TH14/24 series unit 52 2.047 mm inch TH13 (without reset function) TYPICAL APPLICATIONS Mounting frame (sold separately): TH1400020 Panel Maintenance management of machine tools, automated machines, control panels, forming machines, medical equipment, generators, compressors, water treatment facilities, presses, motors, etc. 45 1. High-performance compact sync motor The accurately turning motor is employed to provide for longer period of measurement. 2. Compact and stylish 3. Easier wiring The flat terminals (#187) are quick and easy to connect. 4. Rotary indicator The rotary indicator makes one turn every 2 minutes for quick monitoring. 5. CE marking The hour meters satisfy EMC directives (EN50081-2/EN50082-2) and low-voltage directives (EN61010-1). 47 FEATURES 48 TH23 (with reset function) 52 54 2.126 The TH13/TH23 series units are interchangeable with the TH14/24 series units. Use the specified mounting frame because of a different setup method. It is advisable to introduce the TH14/23 series units for the first time. DIN48 size and mounting frame setup Mounting flame SPECIFICATIONS Rated operating voltage Operating voltage range Rated frequency Counting range Minimum time display Rated power consumption Initial insulation resistance (At 500 V DC) Initial breakdown voltage Max. temperature rise Vibration resistance Functional Functional Shock resistance Destructive Ambient temperature Ambient humidity Weight 100V, 200V, 110V, 115 to 120V, 220V, 240V 85 to 115% of rated operating voltage 50 Hz, 60 Hz (other model) 0 to 99999.9 hours (TH13 series) 0 to 9999.9 hours (TH23 series) 0.1 hours (6 min) Approx. 1.5 W Min. 100 M Between live and dead metal parts 2,000 Vrms Between live and dead metal parts 55C 131F 10 to 55 Hz: 1 cycle/min double amplitude of 0.5 mm (10 min on 3 axes) Min. 98 m/s2 {10 G} (4 times on 3 axes) Min. 980 m/s2 {100 G} (5 times on 3 axes) -10 to +50C +14 to 122F Max. 85% RH 135 g 4.76 oz 130 g 4.59 oz PRODUCT TYPE Part No. 50Hz 60Hz 24V AC TH1325 TH1326 100V AC TH1345 TH1346 115V AC (115 to 120V AC) TH1375 TH1376 TH13 types (without reset) 200V AC TH1355 TH1356 220V AC TH1385 TH1386 110V AC TH1365 TH1366 240V AC TH1395 TH1396 24V AC TH2325 TH2326 100V AC TH2345 TH2346 115V AC (115 to 120V AC) TH2375 TH2376 TH23 types (with reset) 200V AC TH2355 TH2356 220V AC TH2385 TH2386 110V AC TH2365 TH2366 240V AC TH2395 TH2396 Notes: 1. The AC 115-120V, AC 220V and AC 240V types are UL-recognized and CSA-certified. For those products, specify "U" at the end of the part No. when ordering. 2. If you want the CE marking on your products, specify "CE" at the end of the part No. when ordering. 3. When ordering a UL-listed/CSA-certified, CE-marked product, specify "TH2376UCE" for example (in the case of TH13 series AC 115-120V, 60Hz type). Type Rated operating voltage Part No. 50Hz 60Hz Rated operating voltage 115 02/2003 TH13*TH23 DIMENSIONS General tolerance: 1.0 .039 mm inch Mounting bracket (supplied) Case * TH13 * TH23 Decorative nut Reset button (TH23 only) 46.8 1.843 RESET 52 2.047 6 .236 52 2.047 Rotary indicator WIRING DIAGRAM No.187 quick connect terminal (4.75 x 6.0 x 0.5) (.187 x .236 x .020) 4.75 .187 5 .197 54 2.126 72 2.835 Rotary indicator Panel mounting * Panel cutout Panel Case Mounting bracket (supplied) Decorative nut M +0.5 47 -0.1 +.020 1.850 -.004 Operating power supply 5 .197 67 2.638 116 02/2003 TH14*TH24 DIN48 SIZE HOUR METER TH14*TH24 FEATURES 80.5 3.169 1. High-performance compact sync motor The accurately turning motor is employed to provide for longer period of measurement. 2. Common for 50/60 Hz power frequency A lever is used to select 50 Hz or 60 Hz. There is no need to rearrange the control panel and other signal destinations. 3. Dimensions as per DIN 43700 standard The units are in the 48 x 48 DIN standard size. They can be fitted in panels and give refined metallic appearance. 4. Easier wiring The flat terminals (#187) are quick and easy to connect. 5. Rotary indicator The rotary indicator makes one turn every 2 minutes for quick monitoring. 6. CE marking The hour meters satisfy EMC directives (EN50081-2/ EN50082-2) and low-voltage directives (EN61010-1). 48 1.890 48 1.890 mm inch Silver panel Black panel TH24 (with reset function) TYPICAL APPLICATIONS Silver panel Maintenance management of machine tools, automated machines, control panels, forming machines, medical equipment, generators, compressors, water treatment facilities, presses, motors, etc. Black panel TH14 (without reset function) SPECIFICATIONS Rated operating voltage Operating voltage range Rated frequency Counting range Minimum time display Rated power consumption Initial insulation resistance (At 500 V DC) Initial breakdown voltage Max. temperature rise Vibration resistance Functional Functional Shock resistance Destructive Ambient temperature Ambient humidity Weight 12 V AC, 24 V AC, 48 V AC, 100 V AC, 110 V AC, 115 to 120 V AC, 200 V AC, 220 V AC, 240 V AC 85 to 115% of rated operating voltage 50/60 Hz (selectable by switch) 0 to 99999.9 hours (TH14 series) 0 to 9999.9 hours (TH24 series) 0.1 hours (6 min) Approx. 1.5 W Min. 100 M; Between live and dead metal parts 2,000 Vrms Between live and dead metal parts 55C 131F 10 to 55 Hz: 1 cycle/min double amplitude of 0.5 mm (10 min on 3 axes) Min 98 m/s2 {10 G} (4 times on 3 axes) Min 980 m/s2 {100 G} (5 times on 3 axes) -10 to +50C +14 to +122F Max. 85% RH 145 g 5.11 oz (TH14 series) 150 g 5.29 oz (TH24 series) PRODUCT TYPE Part No. Part No. Part No. Rated operating Rated operating Rated operating voltage voltage voltage Silver panel Black panel Silver panel Black panel Silver panel Black panel 100V AC TH141S TH141 24V AC TH144S TH144 115 to 120V AC TH147S TH147 TH14 types 200V AC TH142S TH142 48V AC TH145S TH145 220V AC TH148S TH148 (without reset) 12V AC TH143S TH143 110V AC TH146S TH146 240V AC TH149S TH149 100V AC TH241S TH241 24V AC TH244S TH244 115 to 120V AC TH247S TH247 TH24 types 200V AC TH242S TH242 48V AC TH245S TH245 220V AC TH248S TH248 (with reset) 12V AC TH243S TH243 110V AC TH246S TH246 240V AC TH249S TH249 Notes: 1. Only the black-panel type is UL-recognized and CSA-certified. For this type, specify "U" at the end of the part No. when ordering. 2. If you want the CE marking on your products, specify "CE" at the end of the part No. when ordering. 3. When ordering a UL-listed/CSA-certified, CE-marked product, specify "TH147UCE" for example (in the case of TH14 series, AC 115-120V type). Type 117 02/2003 TH14*TH24 DIMENSIONS General tolerance: 1.0 .039 mm inch Case Mounting bracket (supplied) No.187 quick connect terminal (4.7 x 6.0 x 0.5) Decorative (.185 x .236 x .020) nut 48 1.890 50 1.969 44.8 1.764 60Hz 50Hz Rotary indicator 5.5 .217 WIRING DIAGRAM 75 2.953 94 3.701 Hz setting switch mm inch Panel mounting * Panel cutout Panel Case Mounting bracket (supplied) Decorative nut M 50 1.969 Operating power supply 5.5 .217 88.5 3.484 118 02/2003 +0.6 45 0 +.024 1.772 0