https://www.phoenixcontact.com/us/products/2905348 Type 2 surge arrester - VAL-SEC-T2-1S-175-FM - 2905348 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Plug-in surge arrester, in accordance with Type 2/Class II, for 1-phase power supply networks with separate N and PE (3-conductor system: L1, N, PE), with remote indication contact. Why buy this product Varistor arrester with a low leakage current High-performance gas-filled surge arrester for N/PE protection Extremely narrow design, just 12 mm per position High continuous voltage of 175 V AC for 120 V AC networks with high voltage fluctuations Pluggable Low voltage protection level of 0.85 kV Optical, mechanical status indicator With floating remote indication contact Plugs can be checked with CHECKMASTER 2 Key Commercial Data Packing unit 1 STK GTIN GTIN 4046356948036 Weight per Piece (excluding packing) 200.000 g Custom tariff number 85363030 Country of origin Germany Technical data Dimensions 03/09/2017 Page 1 / 6 https://www.phoenixcontact.com/us/products/2905348 Type 2 surge arrester - VAL-SEC-T2-1S-175-FM - 2905348 Technical data Dimensions Height 97.9 mm Width 25.4 mm Horizontal pitch 1.4 Div. Ambient conditions Degree of protection IP20 Ambient temperature (operation) -40 C ... 80 C Ambient temperature (storage/transport) -40 C ... 80 C Altitude 2000 m (amsl (above mean sea level)) Permissible humidity (operation) 5 % ... 95 % Shock (operation) 30g (half sinus / 11 ms / 3x X, Y, Z) Vibration (operation) 5g (10 ... 500 Hz / 2.5 h / X, Y, Z) General IEC test classification II T2 EN type T2 IEC power supply system TN-S TT Mode of protection L-N L-PE N-PE Mounting type DIN rail: 35 mm Color light grey RAL 7035 traffic grey A RAL 7042 Housing material PA 6.6-FR 20% GF PBT-FR Degree of pollution 2 Flammability rating according to UL 94 V-0 Design DIN rail module, two-section, divisible Number of positions 2 Surge protection fault message Optical, remote indicator contact Protective circuit Nominal voltage UN 120 V AC (TN-S) 120 V AC (TT) Nominal frequency fN 50 Hz (60 Hz) Maximum continuous operating voltage UC (L-N) 175 V AC Maximum continuous operating voltage UC (L-PE) 175 V AC 03/09/2017 Page 2 / 6 https://www.phoenixcontact.com/us/products/2905348 Type 2 surge arrester - VAL-SEC-T2-1S-175-FM - 2905348 Technical data Protective circuit Maximum continuous voltage UC (N-PE) 150 V AC Rated load current IL 40 A (Biconnect M4 fork-type cable lug 6 mm) 63 A (TWIN ferrule 2 x 10 mm) Residual current IPE 1 A Nominal discharge current In (8/20) s 20 kA Maximum discharge current Imax (8/20) s 40 kA Follow current interrupt rating Ifi (N-PE) 100 A (150 V AC) Short-circuit current rating ISCCR 25 kA (in case of 315 A gG backup fuse) 50 kA (in case of 200 A gG backup fuse) Voltage protection level Up (L-N) 0.85 kV Voltage protection level Up (L-PE) 1.3 kV Voltage protection level Up (N-PE) 0.95 kV Residual voltage Ures (L-N) 0.85 kV (at In) 0.75 kV (at 10 kA) 0.65 kV (at 5 kA) 0.63 kV (at 4 kA) 0.57 kV (at 2 kA) Residual voltage Ures (N-PE) 0.4 kV (at In) 0.4 kV (at 10 kA) 0.4 kV (at 5 kA) 0.4 kV (at 4 kA) 0.4 kV (at 2 kA) TOV behavior at UT (L-N) 240 V AC (5 s / withstand mode) 240 V AC (120 min / safe failure mode) TOV behavior at UT (N-PE) 1200 V AC (200 ms / withstand mode) Response time tA (L-N) 25 ns Response time tA (N-PE) 100 ns Max. backup fuse with branch wiring 315 A (gG) Max. backup fuse with V-type through wiring 40 A (gG / Biconnect M4 fork-type cable lug, 6 mm) 63 A (gG / TWIN ferrule 2x 10mm) Indicator/remote signaling Switching function PDT contact Operating voltage 5 V AC ... 250 V AC 125 V DC (200 mA DC) Operating current 5 mA AC ... 1 A AC 1 A DC (30 V DC) 03/09/2017 Page 3 / 6 https://www.phoenixcontact.com/us/products/2905348 Type 2 surge arrester - VAL-SEC-T2-1S-175-FM - 2905348 Technical data Indicator/remote signaling Connection method Pluggable screw connection Screw thread M2 Tightening torque 0.25 Nm Stripping length 7 mm Conductor cross section flexible 0.14 mm ... 1.5 mm Conductor cross section solid 0.14 mm ... 1.5 mm Conductor cross section AWG 28 ... 16 Connection data Connection method Screw connection Screw thread M5 Tightening torque 4.5 Nm Stripping length 16 mm Conductor cross section flexible 2.5 mm ... 16 mm Conductor cross section solid 2.5 mm ... 25 mm Conductor cross section AWG 12 ... 4 UL specifications SPD Type 4CA Maximum continuous operating voltage MCOV (L-N) 175 V AC Maximum continuous operating voltage MCOV (L-G) 175 V AC Maximum continuous operating voltage MCOV (N-G) 150 V AC Nom. voltage 120 V AC Mode of protection L-N L-G N-G Power distribution system 1 Nominal frequency 50/60 Hz Measured limiting voltage MLV (L-N) 1510 V Measured limiting voltage MLV (L-G) 1630 V Measured limiting voltage MLV (N-G) 560 V Nominal discharge current In (L-N) 20 kA Nominal discharge current In (L-G) 20 kA Nominal discharge current In (N-G) 20 kA UL indicator/remote signaling Operating voltage 125 V AC Operating current 1 A AC Tightening torque 2 lbf-in. ... 4 lbf-in. 03/09/2017 Page 4 / 6 https://www.phoenixcontact.com/us/products/2905348 Type 2 surge arrester - VAL-SEC-T2-1S-175-FM - 2905348 Technical data UL indicator/remote signaling Conductor cross section AWG 30 ... 14 UL connection data Conductor cross section AWG 14 ... 2 (solid) 14 ... 4 (stranded) 40 lbf-in. ... 50 lbf-in. Tightening torque Standards and Regulations Standards/regulations IEC 61643-11 2011 EN 61643-11 2012 Approvals Approvals Approvals UL Recognized / KEMA-KEUR / cUL Recognized / CCA / IECEE CB Scheme / GL / EAC / cULus Recognized Ex Approvals Approval details UL Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 330181 KEMA-KEUR http://www.dekra-certification.com 2196453.01 cUL Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 330181 CCA NTR-NL 7347 03/09/2017 Page 5 / 6 https://www.phoenixcontact.com/us/products/2905348 Type 2 surge arrester - VAL-SEC-T2-1S-175-FM - 2905348 Approvals IECEE CB Scheme http://www.iecee.org/ NL-34356 GL http://exchange.dnv.com/tari/ 13947-15 HH EAC cULus Recognized RU CDE.A*30.B01561 http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm Phoenix Contact 2017 (c) - all rights reserved http://www.phoenixcontact.com 03/09/2017 Page 6 / 6