VES120 Series AC-DC Power Supplies 120 Watts * Energy Efficiency Level VI * European CoC Tier 2 * High Power Density * Single Outputs from 12 V to 24 V * <0.15 W Standby Power * China Compulsory Certification (CCC) Qualified * 0 C to 60 C Operation B R A N D * Optional Output Connector * Low Cost Dimensions: VES120: 6.61 x 2.80 x 1.48" (168.0 x 71.0 x 37.5 mm) Models & Ratings Output Power Output Voltage 12.0 V 19.0 V 24.0 V 120 W Output Current 10.00 A 6.32 A 5.00 A Total Regulation Efficiency(1) Model Number 5% 89% 89% 89% VES120PS12 VES120PS19(2) VES120PS24(2) Notes 1. Typical average of efficiencies measured at 25%, 50%, 75% and 100% load and 230 VAC input. 2. For optional Barrel Jack Connector, 2.5 mm inner positive, 5.5 mm outer negative, 11 mm length add suffix `-B' e.g. VES120PS24-B. Mechanical Details 47.240.79 (120020) 6.61 (168.0) 2.800.04 (71.01) 2.760.20 (705) 19V & 24V: UL 10748 16AWG*1C+S Black 12V: UL 10748 14AWG*1C+S Black 4 PINS DC POWER CONNECTOR Pin 1 2 3 4 Function Output + Output + Return Return Shell Connected to output return and input ground 1 3 2 4 2.360.79 (6020) 4.720.79 (12020) 2.360.79 (6020) 1.480.02 (37.50.5) IEC320-C14 CORE: o14.2*2*o7.0*L28.5 Notes 1. All dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except output cable length. 2. Output connector: Power Mini DIN, mates with Kycon KPJ-4S or equivalent. 1 3. Weight: 1.27 lbs (580 g) approx. www.xppower.com For optional barrel jack connector, outer sleeve (negative) is connected to input ground VES120 Series AC-DC Power Supplies Input Characteristic Minimum Notes & Conditions Maximum Units 264 VAC 63 130 Hz A A 0.15 A W Max. 24 2 Units VDC % 3 50 Full load and 115 VAC 0.5 5 s ms ms % % Transient Response 10 % Maximum deviation, recovering to less than 1% within 500 s for 50% step load Ripple and Noise 2/1 % pk-pk 200 180 % % % Input Voltage 90 Input Frequency Input Current Inrush Current Power Factor Earth Leakage Current No Load Input Power Input Protection 47 Typical 2/1 500 Measured at 115/230 VAC 230 VAC, cold start at 25 C EN61000-3-2 Class A 264 VAC, 60 Hz T3.15A/250 VAC internal fuse in line Output Characteristic Output Voltage Initial Set Accuracy Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Line Regulation Total Regulation Min. 12 Typ. 8 Overshoot Overload Protection Overvoltage Protection Short Circuit Protection Temperature Coefficient 2 120 Trip and restart (hiccup), auto resetting 0.04 Notes & Conditions See Models and Ratings table At 50% load No minimum load required 2% for 12 V, 1% for 19 & 24 V, 20 MHz bandwidth, measured with 20 MHz Bandwidth and 10 F electrolytic in parallel with 0.1 F ceramic capacitor. At turn on / turn off Recycle mains to reset %/C Environmental Characteristic Operating Temperature Cooling Operating Humidity Storage Temperature Operating Altitude Shock Vibration Minimum 0 Natural convection 10 -40 Typical Maximum +60 Units C Notes & Conditions Derate from 100% load at 40 C to 50% load at 60 C 90 %RH Non-condensing +70 C 5000 m IEC68-2-27, 30 g, 30 ms half sine, 3 times in each of 6 axes IEC68-2-6, 10-300 Hz, 2 g 15 mins/sweep, 60 mins for each of 3 axes, non operating 100% Output Power (%) Derating Curve 80% 60% 40% 20% 0 20 40 Ambient Temperature (C) www.xppower.com 60 2 VES120 Series AC-DC Power Supplies General Characteristic Minimum Typical Efficiency Maximum Units % 89 Isolation: Input to Output Input to Ground Output to Ground Notes & Conditions See Models and Ratings table and curves. VAC 3000 1500 VAC VDC Output return is connected to input ground At full load Switching Frequency 55 kHz Power Density 4.3 W/in3 Mean Time Between Failure Weight >200 kHrs 1.27 (580) lb (g) MIL-HDBK-217F at 25 C GB Efficiency Curves VES120PS12 100% 90% Efficiency 80% 115Vac 230Vac 70% 60% 50% 10 20 30 40 50 60 70 80 90 100 Load (%) VES120PS24 100% Efficiency 90% 80% 115Vac 230Vac 70% 60% 50% 10 20 30 40 50 60 70 80 90 100 Load (%) EMC: Emissions Phenomenon Emissions Harmonic Current Voltage Flicker Standard EN55032 EN61000-3-2 EN61000-3-3 Test Level Level B Class A www.xppower.com Notes & Conditions Conducted & Radiated 3 VES120 Series AC-DC Power Supplies EMC: Immunity Phenomenon Standard ESD Radiated EFT/Burst Surge Conducted Magnetic Fields EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-8 Dips and Interruptions EN61000-4-11 Test Level Criteria 8 kV Air, 4 kV contact 3 V/m 2 Installation Class 3 3V 3 A/m Dip: 30% 500 ms Dip: 60% 200 ms Dip: 100% 5000 ms Int: 100% 10 ms A A A A A A A/B A/B B A Notes & Conditions High Line/Low Line High Line/Low Line Safety Approvals Safety Agency Safety Standard UL Notes & Conditions UL60950-1 TUV EN60950-1 CB IEC60950-1 CCC China Compulsory Certification, GB4943 AU/NZ AU/NZ 60950.1 Mechanical Details 47.240.79 (120020) 6.61 (168.0) 2.800.04 (71.01) 2.760.20 (705) 19V & 24V: UL 10748 16AWG*1C+S Black 12V: UL 10748 14AWG*1C+S Black 4 PINS DC POWER CONNECTOR 1 3 2 4 2.360.79 (6020) 4.720.79 (12020) 2.360.79 (6020) 1.480.02 (37.50.5) IEC320-C14 CORE: o14.2*2*o7.0*L28.5 Pin 1 2 3 4 Function Output + Output + Return Return Shell Connected to output return and input ground For optional barrel jack connector, outer sleeve (negative) is connected to input ground Notes 1. All dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except output cable length. 2. Output connector: Power Mini DIN, mates with Kycon KPJ-4S or equivalent. 3. Weight: 1.27 lbs (580 g) approx. www.xppower.com 31 Jan 19