ADP 56WA/WB Series
ADP 56WA/WB Series
SPECIFICATIONS
INPUT VIBRATION
Input Voltage Universal, 90 to 265 V Frequency 5~100Hz
Input Frequency 47 to 63Hz Amplitude 25mm MAX
Input Current 1.4A or less Acceleration 0.5G
Inrush Current 100A or less at cold start Sweep Time 1 min
AC Turn-on Time 3 sec. or less at 90 V Direction X, Y, Z
Vibration Time 10 min
OUTPUT SHOCK
Output Power 56W Storage Passes lifting the unit and dropping it
Over-Current Protection Yes, Constant current from 1.5 meter high to an oak
Over-Voltage Protection Yes, 22V or less board
Leakage Current 250µA max (240V,50Hz) Operation Shock acceleration: 2.0G
Thermal Protection Yes, Shut down Sine wave: 10ms
Reset Time after Shutdown 20 sec. or less at 264V Direction of force: X,Y,Z
Output Rise-up Time 90 msec. or less Apply 10 Times in 1 sec. interval
EMI Regulations VCCI Class-II
ENVIRONMENTAL FCC Class-B (115 V)
Operating Temperature 5~40°CCISPR22 Class-B (230 V)
Storage Temperature -31~+60°CSafety Standards Dentori, Kou-Syu
Cooling Free air convection UL No.1950 2nd Edition, UL1310
Storage Humidity 8~80% CSA C22.2 No. 950
Operation Humidity 8~80% IEC-No. 950
Hi-Pot Test P-S 3 kv 1sec. (10 mA or less)
Insulation Resistance P-S DC 500 V. 50 MW or more