All specifications are subject to change without notice.
Conformity to RoHS Directive: This means that, in conformity with EU Directive 2002/95/EC, lead, cadmium, mercury, hexavalent chromium, and specific
bromine-based flame retardants, PBB and PBDE, have not been used, except for exempted applications.
Common Mode Filters
For automotive power line
ACM-V series
Type:
Issue date:
ACM70V
ACM90V
ACM12V
September 2011
(1/3)
001-02 / 20110928 / e9713_acm_v.fm
• All specifications are subject to change without notice.
Common Mode Filters
For Automotive Power Line
ACM-V Series ACM70V, ACM90V, ACM12V
FEATURES
Have achieved miniaturization while keeping characteristics by
adoption of exclusive square type closed magnetic cores.
Due to the low profile design, it is suitable for surface mount.
High impedance characteristic has been achieved a superior
effect for common mode noise suppression.
This products have serialized a large current product up to 8A
corresponding for various DC power lines.
Operating temperature range has covered widely from –40 to
+125°C.
APPLICATIONS
Common mode noise countermeasures for DC power lines of elec-
tronic control equipment, multi-media equipment for automotives
and various electronic equipment power supply lines.
TEMPERATURE RANGES
PACKAGING STYLE AND QUANTITIES
PRODUCT IDENTIFICATION
(1) Series name
(2) Dimensional code
(3) Impedance [at 100MHz]
701: 700
(4) Numbers of lines
2PL: 2-line
(5) Packaging style
TL: ø330mm reel taping
(6) TDK internal code
RECOMMENDED SOLDERING CONDITIONS
RECOMMENDED TEMPERATURE PROFILE
FOR LEAD-FREE SOLDER
REFLOW PROFILE FOR SOLDER HEAT RESISTANCE
Conformity to RoHS Directive
Operating –40 to +125°C
Storage(After mount) –40 to +125°C
Packaging style Type Quantity
Taping
ACM70V 1500 pieces/reel
ACM90V 800 pieces/reel
ACM12V 500 pieces/reel
ACM 90V - 701 - 2PL - TL -
(1) (2) (3) (4) (5) (6)
150˚C
180˚C
Peak 245˚C max.
230˚C
60 to 120s 10 to 30s
Natural
cooling
Time(s)
150˚C
180˚C
Peak 260˚C max.
230˚C
60 to 120s 40s max.
Natural
cooling
Time(s)
Conformity to RoHS Directive: This means that, in conformity with EU Directive 2002/95/EC, lead, cadmium, mercury, hexavalent chromium, and specific
bromine-based flame retardants, PBB and PBDE, have not been used, except for exempted applications.
(2/3)
001-02 / 20110928 / e9713_acm_v.fm
• All specifications are subject to change without notice.
SHAPES AND DIMENSIONS/CIRCUIT DIAGRAM/RECOMMENDED PC BOARD PATTERN
Dimensions in mm
ELECTRICAL CHARACTERISTICS
TYPICAL ELECTRICAL CHARACTERISTICS
IMPEDANCE vs. FREQUENCY CHARACTERISTICS
ACM70V-701-2PL ACM12V-701-2PL
Type L W T A B C D Weight
ACM70V 7.0±0.2 6.0±0.2 3.5max. 1.5±0.2 1.5±0.2 1.5±0.2 4.0typ. 0.35g
ACM90V 9.0±0.2 7.0±0.2 4.5max. 1.5±0.2 2.0±0.2 1.5±0.2 6.0typ. 0.82g
ACM12V 12.0±0.3 11.0±0.3 6.0max. 2.7±0.2 2.5±0.2 2.3±0.2 7.4typ. 2.30g
Part No.
Common mode
impedance
()typ.[at 100MHz]
DC resistance
(m)max.
Rated current
Idc
(A)max.
Rated voltage
Edc
(V)max.
Insulation
resistance
(M)min.
ACM70V-701-2PL-TL 700 15 4.0 80 10
ACM90V-701-2PL-TL 700 10 5.0 80 10
ACM12V-701-2PL-TL 700 6 8.0 80 10
L
WTABA
DCCCoplanarity: 0.1max.
1
2
4
3
1
2
4
3
• No polarity
d
b
a
c
Dimensions in mm
Ty p e a b c d
ACM70V 9.0 4.0 1.5 3.0
ACM90V 11.0 6.0 1.5 3.5
ACM12V 14.0 7.4 2.7 5.2
101
1
10000
1000
10
100
100 1000
Impedance()
Frequency(MHz)
Common mode
Differential mode
101
1
10000
1000
10
100
100 1000
Impedance()
Frequency(MHz)
Common mode
Differential mode
(3/3)
001-02 / 20110928 / e9713_acm_v.fm
• All specifications are subject to change without notice.
TYPICAL ELECTRICAL CHARACTERISTICS
IMPEDANCE vs. FREQUENCY CHARACTERISTICS
ACM90V-701-2PL
101
1
10000
1000
10
100
100 1000
Impedance()
Frequency(MHz)
Common mode