IMS-5 Vishay Dale Inductors, Commercial, Molded Shielded, Axial Leaded FEATURES * * * * INDUCTANCE RANGE AND MILITARY STANDARD INDUCTANCE RANGE MATERIAL FROM TO CORE SHIELD 0.10 H 0.82 H Phenolic Powd. Iron 1.0 H 12 H Powd. Iron Powd. Iron 15 H 8200 H Ferrite Ferrite ENVIRONMENTAL PERFORMANCE TEST CONDITIONS SPECIFICATIONS Barometric Pressure Test Condition C MIL-STD-202, Method 105 Thermal Shock Test Condition A-1 MIL-STD-202, Method 107 Flammability - MIL-STD-202, Method 111 Overload - MIL-PRF-15305 Low Temperature Storage - MIL-PRF-15305 Resistance to Soldering Heat Resistance to Solvents Test Condition A - Wide inductance range in small package Flame retardant coating Electromagnetic shield-finest shield available Epoxy molded construction provides superior moisture protection * Precision performance, excellent reliability, sturdy construction * Compliant to RoHS directive 2002/95/EC ELECTRICAL SPECIFICATIONS Inductance Tolerance: 10 % standard, 5 % available Insulation Resistance: 1000 M minimum per MIL-STD-202, method 302, test condition B Dielectric Withstanding Voltage: 1000 VAC per MIL-STD-202, method 301 (sea level) Percent Coupling: 3 % maximum per MIL-PRF-15305 Operating Temperature: - 55 C to + 105 C MECHANICAL SPECIFICATIONS Terminals: 5 pounds pull per MIL-STD-202, method 211, test condition A Weight: IMS-5 = 0.85 g maximum MATERIAL SPECIFICATIONS Encapsulant: Epoxy Standard Terminals: #22 AWG tinned copper DIMENSIONS in inches [millimeters] 1.44 0.188 [36.57 4.78] MIL-STD-202, Method 210 MIL-STD-202, Method 215 0.025 0.002 [0.635 0.051] 0.410 0.020 [10.41 0.508] 0.162 0.010 [4.11 0.254] STANDARD ELECTRICAL SPECIFICATIONS IND. Q TEST FREQ. SELF-RESONANT DCR AT 25 C RATED DC INCREMENTAL TOL. (H) MIN. L AND Q (MHz) FREQ MIN. (MHz) (1) MAX. () CURRENT (mA) (2) CURRENT (mA) (3) 0.10 10 % 50 25.0 250.0 0.025 1790 0.12 10 % 51 25.0 250.0 0.034 1530 0.15 10 % 51 25.0 250.0 0.037 1470 0.18 10 % 50 25.0 250.0 0.047 1300 0.22 10 % 49 25.0 250.0 0.067 1100 0.27 10 % 47 25.0 250.0 0.11 855 0.33 10 % 46 25.0 250.0 0.13 780 0.39 10 % 44 25.0 250.0 0.18 670 0.47 10 % 44 25.0 235.0 0.25 565 0.56 10 % 43 25.0 210.0 0.33 490 0.68 10 % 42 25.0 190.0 0.45 420 0.82 10 % 40 25.0 180.0 0.59 370 1.0 10 % 44 25.0 140.0 0.07 1070 1.2 10 % 44 7.9 130.0 0.10 895 1.5 10 % 44 7.9 115.0 0.12 815 1.8 10 % 44 7.9 105.0 0.14 775 2.2 10 % 44 7.9 100.0 0.19 650 2.7 10 % 44 7.9 92.0 0.28 535 3.3 10 % 44 7.9 85.0 0.35 480 Notes (1) Measured with full length lead (2) Rated DC Current: Based on maximum temperature rise not to exceed 15 C at + 90 C ambient (3) Incremental Current: The minimum typical current at which the inductance will be decreased by 5 % from its initial zero DC value www.vishay.com 24 For technical questions, contact: magnetics@vishay.com Document Number: 34048 Revision: 14-Sep-09 IMS-5 Inductors, Commercial, Molded Shielded, Axial Leaded Vishay Dale STANDARD ELECTRICAL SPECIFICATIONS IND. Q TEST FREQ. SELF-RESONANT DCR AT 25 C RATED DC INCREMENTAL TOL. (H) MIN. L AND Q (MHz) FREQ MIN. (MHz) (1) MAX. () CURRENT (mA) (2) CURRENT (mA) (3) 3.9 10 % 44 7.9 75.0 0.40 450 4.7 10 % 44 7.9 70.0 0.55 380 5.6 10 % 44 7.9 65.0 0.72 335 6.8 10 % 50 7.9 55.0 1.02 280 8.2 10 % 50 7.9 50.0 1.32 250 10 10 % 50 7.9 46.0 1.62 220 12 10 % 55 2.5 44.0 2.00 200 15 10 % 45 2.5 49.0 0.80 315 250.0 18 10 % 45 2.5 45.0 0.89 300 235.0 22 10 % 45 2.5 41.0 0.96 290 220.0 27 10 % 45 2.5 38.0 1.19 260 200.0 33 10 % 45 2.5 34.0 1.37 240 190.0 39 10 % 50 2.5 29.0 1.93 205 180.0 47 10 % 50 2.5 27.0 2.11 195 175.0 56 10 % 50 2.5 25.0 2.23 190 160.0 68 10 % 50 2.5 21.0 2.70 170 150.0 82 10 % 50 2.5 10.5 2.44 180 140.0 100 10 % 50 2.5 10.0 3.12 160 120.0 120 10 % 55 0.79 9.7 3.6 150 95.0 150 10 % 55 0.79 8.5 4.1 140 90.0 180 10 % 55 0.79 8.0 4.4 135 85.0 220 10 % 55 0.79 7.5 5.0 125 80.0 270 10 % 55 0.79 7.0 5.8 115 70.0 330 10 % 55 0.79 6.5 6.4 110 65.0 390 10 % 60 0.79 6.2 7.4 105 60.0 470 10 % 60 0.79 5.7 9.5 92 58.0 560 10 % 60 0.79 4.7 10.5 90 55.0 680 10 % 60 0.79 4.5 11.8 80 50.0 820 10 % 60 0.79 4.2 13.0 80 45.0 1000 10 % 60 0.79 3.8 17.5 70 40.0 1200 10 % 45 0.25 1.5 22.1 60 35.0 1500 10 % 45 0.25 1.2 26.5 55 33.0 1800 10 % 45 0.25 1.0 29.9 50 30.0 2200 10 % 45 0.25 0.97 33.8 50 27.0 2700 10 % 45 0.25 0.92 47.3 40 25.0 3300 10 % 45 0.25 0.84 53.0 40 22.0 3900 10 % 45 0.25 0.80 73.8 35 20.0 4700 10 % 45 0.25 0.74 81.6 31 19.0 5600 10 % 44 0.25 0.73 98.9 28 17.0 6800 10 % 40 0.25 0.66 111.0 27 16.0 8200 10 % 40 0.25 0.54 119.0 26 15.0 Notes (1) Measured with full length lead (2) Rated DC Current: Based on maximum temperature rise not to exceed 15 C at + 90 C ambient (3) Incremental Current: The minimum typical current at which the inductance will be decreased by 5 % from its initial zero DC value DESCRIPTION IMS-5 MODEL 10 H INDUCTANCE VALUE 10 % INDUCTANCE TOLERANCE ER PACKAGE CODE e2 JEDEC LEAD (Pb)-FREE STANDARD GLOBAL PART NUMBER INFORMATION I M S MODEL Document Number: 34048 Revision: 14-Sep-09 0 5 E R PACKING CODE 1 0 0 INDUCTANCE VALUE For technical questions, contact: magnetics@vishay.com K TOL. www.vishay.com 25 Legal Disclaimer Notice Vishay Disclaimer All product specifications and data are subject to change without notice. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, "Vishay"), disclaim any and all liability for any errors, inaccuracies or incompleteness contained herein or in any other disclosure relating to any product. Vishay disclaims any and all liability arising out of the use or application of any product described herein or of any information provided herein to the maximum extent permitted by law. The product specifications do not expand or otherwise modify Vishay's terms and conditions of purchase, including but not limited to the warranty expressed therein, which apply to these products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications unless otherwise expressly indicated. Customers using or selling Vishay products not expressly indicated for use in such applications do so entirely at their own risk and agree to fully indemnify Vishay for any damages arising or resulting from such use or sale. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. Product names and markings noted herein may be trademarks of their respective owners. Document Number: 91000 Revision: 18-Jul-08 www.vishay.com 1