My Links Home> Products > Piezoresistive Silicon > 170PC > Product Page 176PC28HD2 Order Product and Get Support U.S. Authorized Distributors Pressure Sensors: Measurement Type: Differential, Gage; Unamplified; Range: 28.0 in H2O Global Sales & Service Login to iCOM Login as Rep/AD Login as Guest Login to Digital University Keyword Search N. American Sales Reps Search for product and support information. Distributor Inventory Technical Assistance Actual product appearance may vary. White Papers All Sensing and Control Literature Request Test and Measurement Catalog RoHS Product List Customer Feedback Potential Applications Features Miniature package ? Low pressure measurement ? Calibrated null and span ? Temperature compensated for span over 0 C to 50 C [32 F to 122 F] ? ? ? ? ? ? ? ? ? Product Search Medical CPAP (Continuous Positive Airway Pressure) equipment Respirators and ventilators Blood glucose monitors Oxygen conservers Oxygen concentrators Nebulizers Blood cell separators Environmental Filter monitoring equipment Part number search: Use (*) to expand search Specification Search Description 170PC Series pressure sensors provide a millivolt output that is proportional to the pressure applied. They operate from 0 inches to 7.0 inches of water to 0 inches to 27.68 inches of water using a single, positive supply voltage ranging from 10.0 Vdc to 16.0 Vdc. When pressure is applied, a differential output voltage, proportional to that pressure, is produced. Supporting Documentation Engineering Drawing Product Specifications Terms & Conditions | Measurement Type Differential, Gage Signal Conditioning Unamplified Pressure Range 28.0 in H Maximum Overpressure 140.0 in H Supply Voltage 10.0 Vdc typ., 16.0 Vdc max. Compensated Yes Output Calibration Yes Response Time 1 ms max. Termination PCB Port Style Straight Package Style Honeywell Linearity 3.0% span max. (P2 > P1), 1.5% span max. (P2 < P1) Typical Sensitivity 1.5 mV/in H Full Scale Span 42 mVdc typ. Null Offset 0 mV typ. Null Shift over Temperature 3.0 % Span Shift Over Temperature 3.5% at 10 vdc Repeatability & Hysteresis Error 0.25 % span typ. Input Resistance 6.3 kOhm Shock Qualification tested to 150 g Vibration MIL - STD - 202 Method 204 (10 Hz to 2000 Hz at 10g) Weight 57 g [2 oz] Operating Temperature Range - 40 C to 85 C [ Compensated Temperature Range 0 C to 50 C [32 F to 122 F] Storage Temperature Range - 55 C to 125 C [ F] Media Compatibility Port 1: Dry gases only. Port 2: Wetted materials. Polyester housing, silicon and silicon adhesives. 2O 2O - 100PC 2O UNSPSC Code 411121 UNSPSC Commodity 411121 Transducers Availability Global Series Name 170PC Privacy Statement | Site Map - 40 F to 185 F] - 67 F to 257 - based