Sealed Miniature Basic Switch D2VW Sealed Miniature Basic Switch Conforms to IP67 (Molded Lead Wire Type Only) Use of epoxy resin assures stable sealing, making this switch ideal for places subject to water spray or excessive dust. V-series internal mechanism assures high preci- sion and long life. Ideal for automobiles, agricultural machines, large-scale home appliances, and industrial equipment, which require high environmental resistance. RoHS Compliant Ordering Information Model Number Legend D2VW-@@-@@ 1 2 3 4 1. Ratings 3. Contact Form 5: 5 A at 250 VAC 01: 0.1 A at 30 VDC 2. Actuator 1: SPDT 2: SPST-NC 3: SPST-NO 4. Terminals None: L1A: L1: L1B: L2A: L2: L3: Pin plunger Short hinge lever Hinge lever Long hinge lever Short hinge roller lever Hinge roller lever Simulated roller lever None, HS: Solder terminals (HS for UL and CSA approval.) M, MS: Molded lead wires (MS for UL and CSA approval) (300 mm length) 1 D2VW D2VW List of Models Actuator Pin plunger Terminals Solder terminals Molded lead wire terminals (300 mm) Short hinge lever Solder terminals Molded lead wire terminals (300 mm) Hinge Lever Solder terminals Molded lead wire terminals (300 mm) Long hinge lever Solder terminals Molded lead wire terminals (300 mm) Short hinge roller lever Solder terminals Molded lead wire terminals (300 mm) Hinge roller lever Solder terminals Molded lead wire terminals (300 mm) Simulated roller lever Solder terminals Molded lead wire terminals (300 mm) Note: 2 Rating Contact form 5A 0.1 A SPDT D2VW-5-1 D2VW-01-1 SPST-NC D2VW-5-2 D2VW-01-2 SPST-NO D2VW-5-3 D2VW-01-3 SPDT D2VW-5-1M D2VW-01-1M SPST-NC D2VW-5-2M D2VW-01-2M SPST-NO D2VW-5-3M D2VW-01-3M SPDT D2VW-5L1A-1 D2VW-01L1A-1 SPST-NC D2VW-5L1A-2 D2VW-01L1A-2 SPST-NO D2VW-5L1A-3 D2VW-01L1A-3 SPDT D2VW-5L1A-1M D2VW-01L1A-1M SPST-NC D2VW-5L1A-2M D2VW-01L1A-2M SPST-NO D2VW-5L1A-3M D2VW-01L1A-3M SPDT D2VW-5L1-1 D2VW-01L1-1 SPST-NC D2VW-5L1-2 D2VW-01L1-2 SPST-NO D2VW-5L1-3 D2VW-01L1-3 SPDT D2VW-5L1-1M D2VW-01L1-1M SPST-NC D2VW-5L1-2M D2VW-01L1-2M SPST-NO D2VW-5L1-3M D2VW-01L1-3M SPDT D2VW-5L1B-1 D2VW-01L1B-1 SPST-NC D2VW-5L1B-2 D2VW-01L1B-2 SPST-NO D2VW-5L1B-3 D2VW-01L1B-3 SPDT D2VW-5L1B-1M D2VW-01L1B-1M SPST-NC D2VW-5L1B-2M D2VW-01L1B-2M SPST-NO D2VW-5L1B-3M D2VW-01L1B-3M SPDT D2VW-5L2A-1 D2VW-01L2A-1 SPST-NC D2VW-5L2A-2 D2VW-01L2A-2 SPST-NO D2VW-5L2A-3 D2VW-01L2A-3 SPDT D2VW-5L2A-1M D2VW-01L2A-1M SPST-NC D2VW-5L2A-2M D2VW-01L2A-2M SPST-NO D2VW-5L2A-3M D2VW-01L2A-3M SPDT D2VW-5L2-1 D2VW-01L2-1 SPST-NC D2VW-5L2-2 D2VW-01L2-2 SPST-NO D2VW-5L2-3 D2VW-01L2-3 SPDT D2VW-5L2-1M D2VW-01L2-1M SPST-NC D2VW-5L2-2M D2VW-01L2-2M SPST-NO D2VW-5L2-3M D2VW-01L2-3M SPDT D2VW-5L3-1 D2VW-01L3-1 SPST-NC D2VW-5L3-2 D2VW-01L3-2 SPST-NO D2VW-5L3-3 D2VW-01L3-3 SPDT D2VW-5L3-1M D2VW-01L3-1M SPST-NC D2VW-5L3-2M D2VW-01L3-2M SPST-NO D2VW-5L3-3M D2VW-01L3-3M 1. The standard lengths of the molded lead wires (AV0.75f) of models incorporating them are 300 mm. 2. Add "HS" or "MS" to the end of the model number for the UL/CSA-approved version (e.g., D2VW-01-1 D2VW-01-1HS). Consult your OMRON sales representative for details. D2VW D2VW Specifications Ratings Item Model D2VW-5 D2VW-01 Note: Resisteve load Rated voltage 250 VAC 5A 125 VAC 5A 30 VDC 5A 125 VAC 0.1 A 30 VDC 0.1 A The ratings values apply under the following test conditions: Ambient temperature: 202C Ambient humidity: 655% Operating frequency: 30 operations/min Characteristics Operating speed 0.1 mm to 1 m/s (pin plunger models) Operating frequency Mechanical: Electrical: Insulation resistance 100 M min. (at 500 VDC) Contact resistance (initial value) 50 m max. (100 m max. for molded lead wire models) Dielectric strength (see note 2) 1,000 VAC, 50/60 Hz for 1 min between terminals of same polarity 1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground 1,500 VAC, 50/60 Hz for 1 min between each terminal and non-current-carrying metal parts Vibration resistance (see note 3) Malfunction: 10 to 55 Hz, 1.5-mm double amplitude Shock resistance (see note 3) Destruction: 1,000 m/s2 {approx. 100G} max. Malfunction: 300 m/s2 {approx. 30G} max. Durability (see note 4) Mechanical: Electrical: Degree of protection IEC IP67 (excluding the terminals on terminal models) Degree of protection against electric shock Class I Proof tracking index (PTI) 175 Ambient operating temperature (see note 5) -40C to 85C (at ambient humidity of 60% max.) (with no icing or condensation) Ambient operating humidity 95% max. (for 5C to 35C) Weight Approx. 7 g (pin plunger models with terminals) Note: 300 operations/min max. 30 operations/min max. 10,000,000 operations min. (60 operations/min) D2VW-5 models: 100,000 operations min. (30 operations/min) D2VW-01 models: 1,000,000 operations min. (30 operations/min) 1. The data given above are initial values. 2. The dielectric strength shown in the table indicates the value for models with a Separator. 3. For the pin plunger models, the above values apply for use at both the free position and total travel position. For the lever models, they apply at the total travel position. 4. For testing conditions, consult your OMRON sales representative. 3 D2VW D2VW Approved Standards Consult your OMRON sales representative for specific models with standard approvals. Contact Specifications Item Contact Rated voltage D2VW-5 D2VW-01 3A 3A Crossbar Material Silver alloy Gold alloy Gap (standard value) 0.5 mm NC 15 A max. --- NO 15 A max. --- Minimum applicable load (see note) 160 mA at 5 VDC 30 VDC 1 mA at 5 VDC Inrush current 0.1 A --- --- 0.1 A EN61058-1 (File No. 104068, VDE approval) Rated voltage D2VW-5 125 VAC 250 VAC Note: D2VW-01 --3A D2VW-01 Rivet UL1054 (File No. E41515)/ CSA C22.2 No.55 (File No. LR21642) 125 VAC 250 VAC D2VW-5 Specification For more information on the minimum applicable load, refer to Using Micro Loads on page 7. 0.1 A --- Testing conditions: 25E3 (25,000 operations), T55 (0C to 55C) for D2VW-5, 1E5 (100,000 operations), T85 (0C to 85C) for D2VW-01 Contact Form SPDT SPST-NC NC (red) NO (blue) COM (black) Note: SPST-NO NC (red) NO (blue) COM (black) COM (black) Colors in parentheses indicate lead wire colors. Dimensions Note: All units are in millimeters unless otherwise indicated. Terminals The pin plunger model is shown here as a typical example. Operating characteristics and dimensions of the actuator section are the same as for the molded lead wire models. Molded Lead Wires Solder/Quick Connect Terminals 2.4 dia. hole 1.3 dia. hole 10.3 AV 0.75f Lead wire (red)* AV 0.75f Lead wire (blue)* AV 0.75f Lead wire (black)* 4.8 1.2 5.2 8.4 0.5 2.5 5.2 5.2 t=0.5 Three, solder terminals 33 41.4 Mounting Holes Two, 3.1-dia. mounting holes or M3 screw holes 10.30.1 22.20.1 4 2.8 33 10.3 30010 * UL/CSA approved models use UL approved wiring (AWG20, UL1015) 22.20.1 2.8 (5) 22.20.1 D2VW D2VW Dimensions and Operating Characteristics Note: 1. All units are in millimeters unless otherwise indicated. 2. Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions. 3. The operating characteristics are for operation in the A direction ( ). 4. The following illustrations and drawing are for molded lead wires (M). Refer to kind of terminals on page 4 for terminals. Pin Plunger Models D2VW-5-1@ D2VW-01-1@ 2.8 A PT OP AV0.75f lead wire (red) * AV0.75f lead wire (blue) * +0.13 3.1-0.03 dia. hole AV0.75f lead wire (black) * 20.20.25 2.5 dia. 15.9 10.30.1 3.1+0.13 -0.03 2.8 3.20.1 dia. 22.20.1 33 OF max. 1.96 N {200 gf} RF min. 0.29 N {30 gf} PT max. 1.2 mm OT min. 1.0 mm MD max. 0.4 mm OP 14.70.4 mm 10.3 (5) *UL/CSA certified models: UL certified wire (AWG20, UL1015) L Wire length 300 mm L 30010 Short Hinge Lever Models D2VW-5L1A-1@ D2VW-01L1A-1@ OF max. 1.96 N {200 gf} RF min. 0.20 N {20 gf} PT max. 1.6 mm OT min. 0.8 mm MD max. 0.5 mm OP 15.20.5 mm OF max. 1.18 N {120 gf} RF min. 0.15 N {15 gf} PT max. 4.0 mm OT min. 1.6 mm MD max. 0.8 mm OP 15.21.2 mm OF max. 0.59 N {60 gf} RF min. 0.05 N {5 gf} PT max. 9.0 mm OT min. 3.2 mm MD max. 2.0 mm OP 15.22.6 mm 24.30.8 OF max. 2.25 N {230 gf} 20.10.8 A 5 RF min. 0.20 N {20 gf} PT max. 1.6 mm OT min. 0.8 mm MD max. 0.5 mm OP 20.70.6 mm 24.3+0.8 t=0.5* A 4.3 5 PT OP 15.9 *Stainless-steel lever 10.3 Hinge Lever Models D2VW-5L1-1@ D2VW-01L1-1@ 35.60.8 t=0.5* A 4.3 5 PT OP 15.9 *Stainless-steel lever 10.3 Long Hinge Lever Models D2VW-5L1B-1@ D2VW-01L1B-1@ 59.40.8 t=0.5* A 4.3 5 PT OP 15.9 *Stainless-steel lever Short Hinge Roller Lever Models D2VW-5L2A-1@ D2VW-01L2A-1@ 4.8 dia. 4.8 ** 10.3 7.2 t=0.5* PT OP 15.9 *Stainless-steel lever **Oil-less polyacetal resin roller 10.3 5 D2VW D2VW Hinge Roller Lever Models D2VW-5L2-1@ D2VW-01L2-1@ A 340.8 4.8 dia. 4.8 ** 7.2 5 t=0.5* PT OP 15.9 *Stainless-steel lever **Oil-less polyacetal resin roller A PT 32.60.8 3.5R t=0.5* 5 4.3 OP 15.9 *Stainless-steel lever 6 1.18 N {120 gf} RF min. 0.15 N {15 gf} PT max. 4.0 mm OT min. 1.6 mm MD max. 0.8 mm OP 20.71.2 mm OF max. 1.18 N {120 gf} RF min. 0.15 N {15 gf} PT max. 4.0 mm OT min. 1.6 mm MD max. 0.8 mm OP 18.71.2 mm 10.3 Simulated Roller Lever Models D2VW-5L3-1@ D2VW-01L3-1@ OF max. 10.3 D2VW D2VW Precautions Refer to General Information. Cautions Correct Use Degree of Protection Mounting Do not use the Switch underwater. The Switch was tested and found to meet the conditions necessary to meet the following standard. The test checks for water intrusion after immersion for a specified time period. The test does not check for switching operation underwater. Use M3 mounting screws with plane washers or spring washers to securely mount the Switch. Tighten the screws to a torque of 0.39 to 0.59 N*m {4 to 6 kgf*cm}. IEC Publication 529, degree of protection IP67. With the pin plunger models, set the Switch so that the plunger can be pushed in from directly above. Since the plunger is covered with a rubber cap, applying a force from lateral directions may cause damage to the plunger or reduction in the sealing capability. Protection Against Chemicals Prevent the Switch from coming into contact with oil and chemicals. Otherwise, damage to or deterioration of Switch materials may result. Operating Body Correct Incorrect Incorrect Handling Handle the Switch carefully so as not to break the sealing rubber of the plunger. Using Micro Loads Using a model for ordinary loads to open or close the contact of a micro load circuit may result in faulty contact. Use models that operate in the following range. However, even when using micro load models within the operating range shown below, if inrush current occurs when the contact is opened or closed, it may increase contact wear and so decrease durability. Therefore, insert a contact protection circuit where necessary. Voltage (V) The minimum applicable load is the N-level reference value. This value indicates the malfunction reference level for the reliability level of 60% ( 60). The equation, 60 = 0.5x10-6/operations indicates that the estimated malfunction rate is less than 1/ 2,000,000 operations with a reliability level of 60%. Operating range for micro load models D2VW-01 Operating range for general-load models D2VW-05 Inoperable range Current (mA) ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. C095-E1-04 7