DK
3ds_61A03_en_dk: 201113D
2. Specifications
Notes:
*1.This value can change due to the switching frequency , environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
*2.Wave is standard shock voltage of 1.250s according to JEC-212-1981
*3.The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to “6. Usage, Storage and Transport
Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information.
Characteristics Item Specifications
Contact Arrangement 1 Form A 1 Form A 1 Form B 2 Form A
Contact resistance (Initial) Max. 30 m (By voltage drop 6 V DC 1A)
Contact material Au-flashed AgSnO2 type Au-flashed AgNi type
Rating
Nominal switching capacity (resistive load) 10 A 250 V AC, 10 A 30 V
DC 8 A 250 V AC,8 A 30 V DC 8 A 250 V AC,8 A 30 V DC
Max. switching power (resistive load) 2,500VA, 300 W 2,000 VA, 240 W 2,000 VA, 240 W
Max. switching voltage 250 V AC, 125 V DC 250 V AC, 125 V DC 250 V AC, 125 V DC
Max. switching current 10 A 8 A 8 A
Nominal operating power 200 mW
Min. switching capacity (Reference value)*110m A 5 V DC
Electrical
characteristics
Insulation resistance (Initial) Min. 1,000M (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Breakdown voltage
(Initial) Between open contacts 1,000 Vrms for 1min. (Detection current: 10mA.)
Between contact and coil 4,000 Vrms for 1min. (Detection current: 10mA.)
Surge breakdown
voltage*2 (Initial) between contacts and coil 10,000 V
Temperature rise (coil) (at 65C 149F) Max. 40C (By resistive method, nominal voltage applied to the coil; max. switching current)
Operate time [Set time] (at 20C 68F)Max. 10 ms (Approx. 5 ms) [10 ms (Approx. 5 ms)]
(Nominal coil voltage applied to the coil, excluding contact bounce time.)
Release time [Reset time] (at 20C 68F)Max. 8 ms (Approx. 3 ms) [10 ms (Approx. 3 ms)]
(Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode)
Mechanical
characteristics
Shock resistance Functional Min. 98 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10s.)
Destructive Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
Vibration resistance Functional 10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10s.)
Destructive 10 to 55 Hz at double amplitude of 3 mm
Expected life Mechanical Min. 5107 (at 300 times/min.)
Electrical Min. 105 (resistive load, at 20 times/min., at rated capacity)
Conditions Conditions for operation, transport and storage*3Ambient temperature: –40C to +65C –40F to +149F,
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed (at rated load) 20 times/min.
Unit weight Approx. 5 g .18 oz Approx. 6 g .21 oz Approx. 6 g .21 oz