Environmental Specications
Operating temperature: -20 °C to 50 °C ambient, derate each output as 2.5% per degree from 50 °C to 70 °C;
-40 °C startup if Standby output ≤ 1A (any valid load on main output);
-30 °C startup if Standby output > 1A (any valid load on main output)
Storage temperature: -40 °C to +85 °C
Electromagnetic susceptibility: Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3
Humidity: Operating; non-condensing 10% to 95% RH
Vibration: IEC68-2-6 to the levels of IEC721-3-2
Ordering Information
Model
Number
Output
Voltage
Minimum
Load
Maximum Load with
Convection Cooling
Maximum Load
with Forced Air
Peak
Load Regulation2
Ripple
P/P (PARD)3
LPS363-M 12 V 0 A 20 A 30 A 39 A ±2% 120 mV
LPS364-M 15 V 0 A 16 A 24 A 31 A ±2% 150 mV
LPS365-M 24 V 0 A 10 A 15 A 19.5 A ±2% 240 mV
LPS368-M 48 V 0 A 5 A 7.5 A 9.75 A ±2% 480 mV
1. Peak current lasting <3 seconds.
2 . At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3 . Peak-to-peak with 20 mHz bandwidth and 10 µF (tantalum capacitor) in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
Pin Assignments
Connector LPS360-M
J4 Pin 1 Neutral
Pin 3 Line
Barr Barr-1 Main output +
Barr-2 Main output common
J5 Pin 1 +V1 Remote sense
Pin 2 -V1 Remote sense
Pin 3 +5 V Standby
Pin 4 5 V Standby return
Pin 5 +Power fail
Pin 6
**
Forced air operation
Pin 7 Inhibit
Pin 8 GND
Pin 9 SDA
Pin 10 SCL
J3 Pin 1 +12 V Fan
Pin 2 12 V fan Return (isolated)
** For forced air operation, connect pin 6 to pin 8 of J5.
Mating Connectors
J4 AC Input Molex 09-50-3031 (connector)
PINS: 08-52-0072
J6 AC Ground Molex 01-90020001
DC Output
(Barr)
Molex 19141-0058/0063 or 19099/0048
Spade lug based on Cable Ampacity/AWG
J5 Control Signals Molex 90142-0010 (USA)
PINS: 90119-2110 or
Amp: 87977-3
PINS: 87309-8
J3 Fan Output Molex 51065-0200
Pins: 50212-8100
The Artesyn Connector Kit #70-841-029, includes all of the above.
1. Specications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02”(±0.5 mm)
3. Mounting holes MH1 and MH2 should be grounded for EMI purposes.
4. Mounting hole MH1 is safety ground connection.
5. Specications are for convection rating at factory settings at 115 VAC input, 25 °C unless
otherwise stated.
6. This power supply requires mounting on metal standoffs 0.20” (5m) in height.
7. Warranty: 3 Years
8. Weight: 0.75 lb/0.34 kg
LPS360-M Series Data Sheet
Digital I2C Interface Accessories
73-769-001 USB to I2C Adapter with USB Cable
73-841-030 LPS360-M I2C Mating Connector
Artesyn Connector Kit #73-769-005 includes both of the above