APC-25 25W Single Output Switching Power Supply series Features : Constant current mode power supply Universal AC input / Full range Withstand 300VAC Surge input for 5 seconds Protections:Short circuit / Over voltage Fully isolated plastic case Small and compact size Cooling by free air convection IP42 design 100% full load burn-in test Suitable for LED related fixture or appliance (such as LED Decoration or Advertisement devices) Low cost / High reliability 2 years warranty IS 15885(Part 2/Sec13) THOMAS SAMUEL THOMAS SAMUEL SPECIFICATION ( only for APC-25-500) R-41027766 APC-25-350 APC-25-500 APC-25-700 APC-25-1050 350mA 500mA 700mA 1050mA DC VOLTAGE RANGE RATED POWER 25~70V 24.5W 15~50V 25.2W 11~36V 25.2W 9~24V 25.2W 300mVp-p 300mVp-p 300mVp-p 83% 83% RIPPLE & NOISE (max.) Note.2 300mVp-p VOLTAGE TOLERANCE Note.3 5.0% 8.0% CURRENT ACCURACY LINE REGULATION 1.0% LOAD REGULATION 3.0% SETUP, RISE TIME 1500ms, 30ms / 230VAC HOLD UP TIME (Typ.) 20ms/230VAC VOLTAGE RANGE INPUT Note.4 127 ~ 370VDC EFFICIENCY(Typ.) 83% AC CURRENT INRUSH CURRENT(Typ.) 0.4A/230VAC;0.8A/115VAC COLD START 45A(twidth=310s measured at 50% Ipeak) at 230VAC MAX. No. of PSUs on 16A CIRCUIT BREAKER 9 units (circuit breaker of type B) / 15 units (circuit breaker of type C) at 230VAC 83% 0.25mA / 240VAC 55 ~ 68V 76 ~ 94V Protection type : Shut down o/p voltage, re-power on to recover WORKING TEMP. -30 ~ 70(Refer to "Derating Curve") WORKING HUMIDITY 20 ~ 90% RH non-condensing ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT 41 ~ 49V 27 ~ 35V -40 ~ +80, 10 ~ 95% RH 0.2%/ (0 ~ 50) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes SAFETY STANDARDS UL8750 (except for APC-25-350), CSA-C22.2 No. 250.0-13 (only for APC-25-700&1050), BIS IS15885, EAC TP TC 004, IP42 approved; design refer to EN60950-1 SAFETY & WITHSTAND VOLTAGE EMC ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY I/P-O/P:3KVAC I/P-O/P:>100M Ohms / 500VDC / 25/ 70% RH Compliance to EN55032,EN61000-3-2 Class A,EN61000-3-3, EAC TP TC 020 Compliance to EN55024,EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV), criteria A, EAC TP TC 020 MIL-HDBK-217F (25) MTBF 518.9K hrs min. DIMENSION 84*57*29.5(L*W*H) 0.13Kg; 72pcs/10.4Kg/0.92CUFT PACKING NOTE 90 ~ 264VAC 47 ~ 63Hz PROTECTION OVER VOLTAGE OTHERS 1500ms, 30ms / 115VAC at full load 12ms/115VAC at full load FREQUENCY RANGE LEAKAGE CURRENT (Note 5) IP42 LPS (except for APC-25-350) RATED CURRENT MODEL OUTPUT (only for APC-25-700&1050) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltage. Please check the static characteristic for more details. 5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 6. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit. 7. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft). 8. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf File Name: APC-25-SPEC 2018-09-29 APC-25 25W Single Output Switching Power Supply series Mechanical Specification Case No.PCD16A 3 Unit:mm 84 15010 15.3 UL1569 18AWG 57 7.3 15010 7.3 UL1569 18AWG AC/N(Blue) 3.6 2 - -8 .9 2 5 15.3 T case 5 AC/L(Brown) V-(BLACK) V+(RED) 3 1.9 29.5 T case: Max. Case Temperature. Block Diagram I/P fosc : 60KHz EMI FILTER POWER SWITCHING RECTIFIERS RECTIFIERS & FILTER +V -V DETECTION CIRCUIT PWM CONTROL Derating Curve Static Characteristics 100 100 90 80 80 70 50 LOAD (%) LOAD (%) 60 40 20 -30 0 10 20 30 40 50 AMBIENT TEMPERATURE () 60 70 (HORIZONTAL) 60 50 40 90 100 200 210 220 230 240 250 264 INPUT VOLTAGE (VAC) 60Hz File Name: APC-25-SPEC 2018-09-29