10-2018, Rev. 1018
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
1
SCHRACK
General Purpose Relays
PCB Relays
n 1 pole 7A, mono or bistable
n 1 form C (CO) or 1 form A (NO) or 1 form B (NC contact)
n Bistable and DC version
n Wash tight version
n Version for 10A on request
Typical applications
Heating control, installation, battery powered equipment
Approvals
UL E214024
Technical data of approved types on request
Contact Data Standard Bistable Sensitive
Contact arrangement 1 form C (CO) or
1 form A (NO) or
1 form B (NC)
Rated voltage 250VAC
Max. switching voltage 400VAC
Rated current 7A 7A 5A
Limiting making current,
max 4 s, duty factor 10% 12A 12A 12A
Breaking capacity max. 1750VA 1750VA 1250VA
Contact material AgNI 90/10 AgNI 90/10 AgNI 90/10
Frequency of operation,
with/without load 600/18000h-1
Operate/release time typ. 5/3ms - 7/3 ms
Set/reset time typ. - 5/3 ms -
Bounce time typ., form A/form B 2/10 ms 2/10 ms 2/10 ms
Mechanical endurance >20x106 operations
Contact ratings
Type Contact Load Cycles
UL508
U/UB C/A/B (CO/NO/NC) 7A, 250VAC,general purpose, 40°C 6.000
Coil Data Standard Bistable Sensitive
Coil voltage range 5 to 48 VDC 3 to 48 VDC 5 to 48 VDC
Operative range IEC 61810 2 2 2
Reset voltage min.,
% of rated coil voltage - 25% -
Reset voltage max.,
% of rated coil voltage - 45% -
Rated operate power - 900 to 1300mW/20ms -
Coil versions, DC coil
Coil Rated Operate Release Coil Rated coil
code voltage voltage voltage resistance power
VDC VDC VDC Ω±10% mW
Standard coil
002 5 3.5 0.5 56 446
003 6 4.2 0.6 80 450
005 12 8.4 1.2 320 450
007 24 16.8 2.4 1280 450
008 48 33.6 4.8 3800 606
Sensitive coil
102 5 3.7 0.5 80 313
103 6 4.4 0.6 110 327
105 12 8.8 1.2 440 327
107 24 17.5 2.4 1780 324
108 48 35.0 4.8 4000 576
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Other coil voltages on request.
Power PCB Relay U/UB (V23148)
Z
10-2018, Rev. 1018
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
2
SCHRACK
General Purpose Relays
PCB Relays
Power PCB Relay U/UB (V23148) (Continued)
Coil versions, bistable 1 coil
Coil Rated Set Reset Coil Rated coil
code voltage voltage voltage resistance power
VDC VDC VDC Ω±10% mW
001 3 2.3 0.75 8 1125
002 5 3.9 1.25 22 1136
003 6 4.7 1.5 33 1091
005 12 9.4 3.0 119 1210
007 24 18.7 6.0 475 1213
008 48 37.4 12.0 1750 1317
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Other coil voltages on request.
Insulation Data 2kVrms 4kVrms
Version Version
V23148-*0*** V23148-*1***
Initial dielectric strength
between open contacts 1000Vrms 1000Vrms
between contact and coil 2000Vrms 4000Vrms
Clearance/creepage
between contact and coil ≥2.5/2.5mm ≥3.5/3.5mm
Material group of insulation parts ≥IIIa ≥IIIa
Other Data
Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content
refer to the Product Compliance Support Center at
www.te.com/customersupport/rohssupportcenter
Ambient temperature -25 to +70°C
Category of environmental protection
IEC 61810 RTIII - wash tight
Terminal type PCB-THT
Weight 8.7g
Vibration resistance (functional), form A/form B 10/10g
Shock resistance (functional), form A/form B 10/10g
Resistance to soldering heat THT
IEC 60068-2-20 260°C/5s
Packaging/unit 25 pcs.
PCB layout / terminal assignment
Bottom view on solder pins
Dimensions
Monostable and bistable 1 coil
Form A contact (NO)
Form C contact (CO)
Form B contact (NC)
10-2018, Rev. 1018
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
3
SCHRACK
General Purpose Relays
PCB Relays
Power PCB Relay U/UB (V23148) (Continued)
Product code structure Typical product code V23148 -A 0 0 07 -A 101
Type
V23148 Power PCB Relay U/UB
Version
A Monostable (Miniature power relay U)
B Bistable (Miniature power relay UB, remanence version)
Dielectric strength coil-contact
0 2kVrms 1 4KVrms
Version
Monostable Bistable
0 Standard 0 Standard
1 Sensitive
Coil
Coil code: please refer to coil versions table
Contact configuration
A 1 form C contact (1 CO) C 1 form B contact (1NC)
B 1 form A contact (1 NO)
Contact configuration
101 AGNI10
Other types on request
Product code Version Dielectric Version Arrangement Part Number
V23148-A0005-C101 Monostable 2000 Vrms Standard 1 form B (NC) 1-1393203-0
V23148-A0007-A101 relay ‚U contact-coil 1 form C (CO) 1-1393203-1
V23148-A0007-B101 1 form A (NO) 1-1393203-2
V23148-A0007-C101 1 form B (NC) 1-1393203-3
V23148-A0008-A101 1 form C (CO) 1-1393203-4
V23148-A0002-A101 1 form C (CO) 1393203-1
V23148-A0002-B101 1 form A (NO) 1393203-2
V23148-A0002-C101 1 form B (NC) 1393203-3
V23148-A0003-A101 1 form C (CO) 1393203-4
V23148-A0003-B101 1 form A (NO) 1393203-5
V23148-A0004-A101 1 form C (CO) 1393203-7
V23148-A0005-A101 1 form C (CO) 1393203-8
V23148-A0005-B101 1 form A (NO) 1393203-9
V23148-A0102-A101 Sensitive 1 form C (CO) 1-1393203-5
V23148-A0102-B101 1 form A (NO) 1-1393203-6
V23148-A0102-C101 1 form B (NC) 1-1393203-7
V23148-A0103-A101 1 form C (CO) 1-1393203-8
V23148-A0103-B101 1 form A (NO) 1-1393203-9
V23148-A0103-C101 1 form B (NC) 2-1393203-0
V23148-A0105-A101 1 form C (CO) 2-1393203-1
V23148-A0105-B101 1 form A (NO) 2-1393203-2
V23148-A0105-C101 1 form B (NC) 2-1393203-3
V23148-A0107-A101 1 form C (CO) 2-1393203-4
V23148-A0107-B101 1 form A (NO) 2-1393203-5
V23148-A0107-C101 1 form B (NC) 2-1393203-6
V23148-A1005-A101 4000 Vrms Standard 1 form C (CO) 2-1393203-7
V23148-A1007-A101 contact-coil 1 form C (CO) 2-1393203-8
V23148-A1105-A101 1 form C (CO) 2-1393203-9
V23148-A1105-B101 1 form A (NO) 3-1393203-0
V23148-A1107-A101 1 form C (CO) 3-1393203-1
V23148-B0007-A101 Bistable 2000 Vrms 1 form C (CO) 1-1393204-0
V23148-B0007-B101 relay ‚UB contact-coil 1 form A (NO) 1-1393204-1
V23148-B0007-C101 1 form B (NC) 1-1393204-2
V23148-B0008-A101 1 form C (CO) 1-1393204-3
V23148-B1001-A101 1 form C (CO) 1-1393204-5
V23148-B0001-A101 1 form C (CO) 1393204-1
V23148-B0002-A101 1 form C (CO) 1393204-2
V23148-B0002-B101 1 form A (NO) 1393204-3
V23148-B0003-B101 1 form A (NO) 1393204-5
V23148-B0003-C101 1 form B (NC) 1393204-6
V23148-B0005-A101 1 form C (CO) 1393204-7
V23148-B0005-B101 1 form A (NO) 1393204-8
V23148-B0005-C101 1 form B (NC) 1393204-9
This list represents the most common types and does not show all variants covered by this data sheet.
Other types on request