DC-DC Converters
50 to 200 Watts
VI-200
VE-200
VI-200 DC-DC Converters Rev 3.9
Page 1 of 7 08/2017
S
NRTL
CUS
CUS
®
Features & Benefits
Isolated output
Up to 50W/in3
cURus, cTÜVus
Up to 90% efficiency
Size: 4.6” x 2.4” x 0.5”
(116,8 x 61,0 x 12,7mm)
Remote sense and current limit
OVP, thermal shutdown
Logic disable
Wide range output adjust
Compatible power booster modules
ZCS power architecture
Low noise FM control
CE Marked
RoHS compliant (VE-200)
Product Highlights
The VI-200 family, with over 14 million units shipped, is Vicor’s broad series of
zero-current-switching” component-level DC-DC converters.
Operating at frequencies up to 2MHz, VI-200 family converters offer exceptional power
density, efficiency, noise performance, reliability and ease of use. Booster modules
(VI-Bxx) provide a simple, cost-effective, off-the-shelf solution for higher power output
requirements. One or more boosters may be used to create synchronous arrays capable
of supplying several kilowatts of output power.
The flexibility of Vicor’s power components is also available in half-size, half-power
VI-J00 MiniMods.
Part Numbering
Note: For additional
packaging options,
please see page 5.
VI 2 6 1 C W
Family Series Input Output Grade Power
VI = Non-RoHS 2 = 200 0 = 12V N = 48V Z = 2V M = 10V K = 40V E = –10 to 85°C ≥ 5V < 5V
VE = RoHS B = Booster V = 24V 4 = 72V Y = 3.3V 1 = 12V 4 = 48V C = –25 to 85°C U = 200W U = 40A
1 = 24V T = 110V 0 = 5V P = 13.8V H = 52V I = 40 to 85°C V = 150W V = 30A
W = 24V 5 = 150V X = 5.2V 2 = 15V F = 72V M = –55 to 85°C W = 100W W = 20A
2 = 36V 6 = 300 V W = 5.5V N = 18.5V D = 85V X = 75W X = 15A
3 = 48V 7 = 150/300V V = 5.8V 3 = 24V B = 95V Y = 50W Y = 10A
T = 6.5V L = 28V
R = 7.5V J = 36V
VI-200 DC-DC Converters Rev 3.9
Page 2 of 7 08/2017
VI-200, VE-200
Converter Specifications
(Typical at TBP = 25°C, nominal line and 75% load, unless otherwise specified.)
Input Specifications
Maximum Power Available for VI-2xx-xx [a]
Input Output
Voltage
Nom. (Range)
Low
Line
75%
Max
Power
Transient [b]
VIN
Designators
VOUT Designators
2
3.3
5
5.2
5.5
5.8
6.5
7.5
10
12
13.8
15
18.5
24
28
36
40
48
52
72
85
95
Z Y 0 X W V T R M 1 P 2 N 3 L J K 4 H F D B
12 (10 – 20) n/a 22 0XXXXXXXXXXXXXXXXXXXXXX
24 (10 – 36) n/a n/a V-- X Y Y Y Y Y X X X X X X X X X X X -- -- -- --
24 (21 – 32) 18 36 1UUUUUUVVUUUUUUUUUUUUUU
24 (18 – 36) n/a n/a WVVVVVVWWVVVVVVVVVVVVVV
36 (21 – 56) 18 60 2W V WWWWWWWWWWWWWWWWW-- -- --
48 (42 – 60) 36 72 3UUUUUUUUUUUUUUUUUUUUUU
48 (36 – 76) n/a n/a NUUUUUUUUUUUUUUUUUUUUUU
72 (55 – 100) 45 110 4vUUUUUVVUUUUUUUUUUUUUU
110 (66 – 160) n/a n/a TVVVVVVWWVVVVVVVVVVVV----
150 (100 – 200) 85 [c] 215 5U U V V V V V V U U U U U U U U U U U U U U
150 (100 – 375) n/a n/a 7WW Y Y Y Y WWWWWWWWWWWWW -- -- --
300 (200 – 400) 170 [d] 425 6UUUUUUVVUUUUUUUUUUUUUU
[a] For additional output power, “booster” modules are available. (VI-Bxx-xx).
[b] Transient voltage for 1 second.
[c] 12VOUT, 13.8VOUT, 15VOUT, 200W models are limited to 90VDC.
[d] 15VOUT, 200W models are limited to 185VDC.
VI-200 E-Grade VI-200 C-, I-, M-Grade
Parameter Min Typ Max Min Typ Max Units Test
Conditions
Inrush charge 120 x 10-6 120 x 10-6 200 x 10-6 Coulombs Nominal line
Input reflected
ripple current – pp 10% 10% IIN
Nominal line,
full load
Input ripple
rejection
25+20 Log 30+20 Log dB 120Hz,
nominal line
20+20 Log dB 2400Hz,
nominal line
No load power
dissipation 1.35 2 1.35 2 Watts
VIN
VOUT
( ) VIN
VOUT
( )
VIN
VOUT
( )