POWER TRANSFORMERS P-8559, P-8560, P-8604 SPECIFICATIONS: ! WARNING ELECTROCUTION HAZARD Disconnect electric power to system at main fuse or circuit breaker box before servicing. Failure to do so could result in death or serious injury. FIRE HAZARD Do not exceed transformer ratings. Higher voltage may damage control and could cause personal injury or property damage. INPUT: 50/60Hz (SEE TABLE BELOW FOR PRIMARY VOLTAGE) OUTPUT: 20V CT, (SEE SECONDARY CURRENT RATING & VA CAPACITY IN TABLE) INSULATION RATING: CLASS A (105 C) TEMPERATURE RISE: 65 C RISE ABOVE 40 C AMBIENT DIELECTRIC STRENGTH: 1500 VRMS D MAX. D MAX. H MAX. .188 .015 DIA. (2 HOLES) MW 2.06 2 1 1 PRI 115V 50/60 Hz STANCOR H MAX. P-XXXX 2 .188 x .312 (4 PLACES) 1 W MAX. STYLE A 3 PRIMARY 50/60Hz (see table below) STYLE NV MW W MAX. 4 SECONDARY 20V CT 5 2 SCHEMATIC DIAGRAM STANCOR Part No. Pri. Volts Mtg. Style Sec. Curr. V.A. Cap. P-8604 P-8559 P-8560 117 115 115 A A NV 1.0A 2.0A 4.0A 20 40 80 Dimensions - Inches H W D MW 2.06 2.69 3.56 3.31 4.06 2.88 2.25 2.38 3.19 2.81 3.56 2.25 Wt. U.L. Lbs. Recog. 1.40 2.50 4.00 Yes* No No Pri. Leads Color AWG Lgth. #1 #2 BLK BLK BLK BLK BLK BLK #22 #22 #18 6" 6" 8" #3 Sec. Leads Color AWG Lgth. #4 (C.T.) #5 GRN GRN/YEL GRN BLU BLU/YEL BLU BLU BLU/YEL BLU #22 #22 #18 6" 6" 8" * Recognized to UL Standard 506, File No. E68100 PART NO. 37-6873A www.stancor.com 0730