■ Safety & EMC Compliance
CUL UL8750, UL1012, UL1310, CSA-C22.2 NO. 107.1, CSA-C22.2 NO. 223-M91
CE EN 61347-1, EN61347-2-13
Conducted emissions FCC Part15 / EN55015 Class B
Radiated emissions FCC Part15 / EN55015 Class B
Harmonic current emissions EN61000-3-2
Voltage fluctuations and flicker EN61000-3-3
Electrostatic discharge EN61000-4-2
RFE field susceptibility EN61000-4-3
Electrical fast transient EN61000-4-4
Surge immunity test EN61000-4-5(Surge: L-N, 4KV, L/N-Earth, 6KV)
Conducted radio frequency EN61000-4-6
Power frequency magnetic field test EN61000-4-8
Voltage dips EN61000-4-11
Electromagnetic immunity EN61547
MU100H Series
■ Features
• Input voltage:90-305VAC
• High efficiency:91% typical
• Active PFC:0.99 typical
• High surge immunity
• Low THD
• IP67 compliant
• Protections:OVP, OCP, OTP, SCP
• Constant Current / 0-10V Dimming / Clock Dimming(CLK) / Standby(STB)
• Compliance to worldwide safety regulations for lighting
• Suitable for dry/damp locations
• CUL / CE
• 5-year warranty
■ Electrical Specifications
Input voltage range 90~305VAC
Frequency 47~63Hz
Power factor 0.99(typical),>0.90 100~277VAC input,80%~100% load
Input current 1.2A at 110VAC, 0.6A at 220VAC
Inrush current 15A at 230VAC input
Leakage current 1mA MAX at 277Vac/50Hz input
Maximum output power 100W
Line regulation ±1%
Load regulation ±3%
Start-up time <3s at 110VAC, <1.5s at 220VAC
Protections over voltage, over current, over temperature, short circuit: auto recovery
THD <10%,220VAC,50Hz input,80%~100% load
<15%,110VAC/277VAC,60Hz input,80%~100% load
■ Environmental Specifications
Operating temperature -40℃ ~ +70℃
Operating humidity 10 ~ 100% RH
Storage temperature -40℃ ~ +80℃
Storage humidity 5 ~ 100% RH
Cooling method convection
Isolation voltage input / output 3750VAC
MTBF 300,000 hours full load at 25℃ ambient
Life time 50,000 hours, 75℃ TC
Reference dimension (L x W x H) 187 x 67.5 x 40 (mm)
Weight 0.85 kg
187 x 67.5 x 40mm