FILTER FAN
FF 018 | 136 CFM
Filter fans are used to provide an optimum climate in enclosures. The interior temperature of an enclosure can
be reduced by channeling cooler filtered outside air into the enclosure thus expelling heated internal air. The
resulting air flow prevents formation of localized heat pockets and protects the electronic components from
overheating. The plastic used for the hood of this filter fan series is impact and UV light resistant. These filter fans
are intended for indoor use.
> High air volume
> Functional design
> Time-saving installation
> UV resistant plastic
Filter fan
View from rear Exhaust filter
TECHNICAL DATA
Axial fan, ball bearing service life min. 50,000 h at 77 °F (25 °C) and 65 %RH
aluminum fan body, metal rotor
Connection 3-pole clamp, AWG 14 (2.5 mm²), clamping torque 0.8 Nm max.
Housing (filter fan and exhaust filter) plastic, UL 94V-0, light grey
Hood (filter fan and exhaust filter) plastic, UL 94V-0, light grey;
UV light resistant according to UL 746C (f1)
Mounting frame with double-sided industrial adhesive for mounting to the
outside of enclosure; certain operating circumstances may
make the additional use of screws necessary; cut-out
template included
Filter media rating G4 acc. to DIN EN 779, filtering degree 94%
Filter material synthetic fiber with progressive construction, temperature
resistant to 212 °F, self-extinguishing class F1;
moisture resistant to 100 %RH, reusable - can be cleaned by
washing or vacuuming
Operating / Storage temperature AC 120 V: -13 to +140 °F (-25 to +60 °C)
AC 230 V: -13 to +122 °F (-25 to +50 °C)
Operating / Storage humidity max. 90 %RH (non-condensing)
Protection class / Protection type I (grounded) / IP55 (according to VDE), UL Type 12
Approvals UL File No. E234324 (all), GOST TR (all), VDE (AC 230 V only)
Drilling template for mounting frame
EXHAUST FILTER EF 118
Part. No. Mounting depth Enclosure cut-out Weight (approx.) Filter mat Protection type
11802.0-00 0.6” (16 mm) 6.9 x 6.9” 1.3 lbs. (0.6 kg) G4 acc. to DIN EN 779, filtering degree 94% IP55²
FILTER MATS FM 086
Part. No. Mounting depth Enclosure cut-out Weight (approx.) Filter mat Protection type
11802.0-00 0.6” (16 mm) 6.9 x 6.9” 1.3 lbs. (0.6 kg) G4 acc. to DIN EN 779, filtering degree 94% IP55²
Part. No. Operating
voltage
Air volume,
free blowing
Air volume with
exhaust filter
Current
consumption
Power
consumption
Average noise level
(DIN EN ISO 4871)
Mounting
depth
Enclosure
cut-out
Weight (approx.)
01804.0-00 AC 230 V, 50 Hz¹ 118 cfm (200 m³/h) 74 cfm (125 m³/h) 320 mA 45 W 52 dB (A) 3.7” (95 mm) 6.9 x 6.9” 3.7 lbs. (1.7 kg)
01804.0-01 AC 120 V, 60 Hz 136 cfm (230 m³/h) 84 cfm (143 m³/h) 470 mA 39 W 52 dB (A) 3.7” (95 mm) 6.9 x 6.9” 3.7 lbs. (1.7 kg)
¹ air volume increases by 15% when operating AC 230 V filter fans at 60 Hz, ² according to VDE
www.stegousa.com08.08.2014 | Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/buyer in its final application.