H.V. Distribution Equipment Instrument transformers ZCT, EVT and special purpose CT Description FUJI can supply special purpose CTs, ZCTs (Zero-phase current transformers) and EVTs (Earthing voltage transformers) as well as standard FUJI instrument transformers. Some of the versions are described below. CP-619 Toroidal type ZCT ZCE2A CED and ZCED The CED and ZCED are splitconstruction types.They can be mounted in position without disconnecting the cables. CED: Epoxy-molded split-toroidal type CT ZCED: Epoxy-molded split-toroidal type ZCT CP-620 Earthing voltage transformer GVE1 Split-toroidal type CT CED2 CP-622 ZCE ZCE type is toroidal-type ZCTs and molded in epoxy resin. GVE and GPE GVE and GPE series are 3-phase earthing voltage transformers. GVE: Epoxy-molded type (3.3kV, 6.6kV) GPE: Epoxy-molded type (11 to 33kV) Type number nomenclature * Toroidal type ZCT * Earthing voltage transformer EVT Basic type GVE, GPE: Epoxy-molded type Basic type ZCE: Epoxy molded toroidal type ZCED: Epoxy molded split-toroidal type Hole diameter, mm 1: 65 4: 125 (ZCE type) 2: 80 (ZCE type) 130 (ZCED type) 90 (ZCED type) 5: 190 (ZCE type) 3: 100 150 (ZCED type) Note: All types are for indoor use only. GPE - F - ZCE A/ Rated primary current (Amps.): 200 to 1500 * Split-toroidal type CT Secondary rated burden GVE GPE: 1: 3 x 100VA 21: 3 x 200VA 2: 3 x 200VA 13: 3 x 200VA 12: 3 x 200VA 9: 3 x 200VA 8: 3 x 200VA 7: 3 x 200VA(400A) Rated primary voltage 3: 3.3kV 10: 11kV 20: 22kV 6: 6.6kV 15: 13.2kV 30: 33kV Rated secondary voltage ( CED / ) Available on request Basic type Hole diameter, mm 1: 65 2: 90 3, 3A, 3B: 100 4: 130 Rated primary current (Amps) 200 to 3000 Toroidal type ZCT Description Hole diameter (mm) Primary current (A) Rated zero-phase current (mA) burden Primary Secondary Rated constant () Overcurrent Indoor use 65 80 100 125 190 0-200 0-400 0-750 0-1200 0-3000 200 1.5 10 n0 > 2000 ZCE1A/200 ZCE2A/400 ZCE3A/750 ZCE4A/1200 ZCE5A/3000 65 90 100 130 150 0-200 0-400 0-600 0-750 0-1500 200 1.5 10 n0 > 2000 ZCED1/200 ZCED2/400 ZCED3/600 ZCED4/750 ZCED5/1500 Epoxy molded toroidal type Indoor use Epoxy molded split-toroidal type 11/46 Type (n0) Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice H.V. Distribution Equipment Instrument transformers Split-toroidal type CT Hole diameter (mm) Primary current (A) Single ratio Double ratio Secondary current (A) Rated burden (VA) Overcurrent constant (n) Type 65 200 300 400 500 600 750 - - - - - - 5 15 15 25 25 40 40 n > 10 CED1/200 CED1/300 CED1/400 CED1/500 CED1/600 CED1/750 90 200 300 400 500 600 750 - - - - - - 5 15 25 40 40 40 40 n > 10 CED2/200 CED2/300 CED2/400 CED2/500 CED2/600 CED2/750 1000 1200 1500 - - - 5 40 40 40 n > 20 CED2/1000 CED2/1200 CED2/1500 300 400 500 600 - - - - 5 25 40 40 40 n > 10 CED3/300 CED3/400 CED3/500 CED3/600 750 1000 1200 1500 2000 3000 - - - - - - 5 40 40 40 40 40 40 n > 20 CED3/750 CED3/1000 CED3/1200 CED3/1500 CED3/2000 CED3/3000 300-150 400-200 - 600-300 5 25 40 40 40 n > 20 CED3A/300 CED3A/400 CED3A/500 CED3A/600 100 300 400 500 600 130 300 300-150 5 40 n > 20 CED3B/300 400 500 600 400-200 - 600-300 5 40 40 40 n >10 CED4/400 CED4/500 CED4/600 750 - 1000 1200 1500 2000 3000 - 800-400 1000-500 1200-600 1500-750 2000-1000 3000-1500 5 40 40 40 40 40 40 40 n > 20 CED4/750 CED4/800 CED4/1000 CED4/1200 CED4/1500 CED4/2000 CED4/3000 11 Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 11/47 H.V. Distribution Equipment Instrument transformers Earthing voltage transformer EVT Rated voltage (V) Impulse*1 (kV) Type Fuse PTFA-6*2 Secondary Tertiary Dielectric strength (kV, 1minute) Primary Secondary 3300 110 110 3 3 x 100 3 x 200 3 x 500 3 x 500 2 2 2 2 45 45 GVE1-3FA-110/5G GVE2-3FA-110/5G 6600 110 110 3 3 x 100 3 x 200 3 x 500 3 x 500 2 2 2 2 60 60 GVE1-6FA-110/5G GVE2-6FA-110/5G 11000 110 110 3 3 x 200 3 x 200 3 x 200 3 x 200 3 x 200 3 x 200 2 2 2 2 2 2 90 75 90 GPE9-10 GPE8-10 GPE7-10 JR-10/5*3 JR-10/5*3 JR-10/5*3 13200 110 110 3 3 x 200 3 x 200 2 2 95 GPE7-15 JR-10N/5*3 22000 110 3 x 200 3 x 200 2 2 125 GPE12-20 JR-20/5*3 22000 110 3 x 200 3 x 200 2 2 150 GPE13-20 JR-20/5*3 33000 110 110 3 110 3 110 3 3 x 200 3 x 200 2 2 170 GPE21-30 - Primary Secondary Rated burden (VA) Tertiary Note: *1: 1.2 x 50s *2: Provided *3: Optional Dimensions, mm Toroidal-type ZCT ZCE1A, 2A, 3A,4A NP X Y L Type d X Y Z H W A B Mass (kg) ZCE1A/200 ZCE2A/400 ZCE3A/750 ZCE4A/1200 65 80 100 125 140 160 185 214 75 90 105 120 180 210 248 287 110 130 155 180 90 90 120 120 40 40 60 60 25 25 35 35 4.0 5.6 8.4 12.0 K Dimensions for reference only. Please confirm before construction begins. H Z od kt Secondary terminal 2-M5 Test terminal 2-M5 lt 3.2 B 20 k W 10 A 135 175 2-o15 20 ZCE5A/3000 o310 100 L K 200 Secondary terminal M5 Test terminal M5 3.2 180 355 o190 25 k kt Lt 25 160 200 40 2-o15 Mass: 14kg 11/48 Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Dimensions, mm Split-toroidal type CT/ZCED NP X Y K a L 4-k od Z Secondary terminal 2-M5 n Test terminal 2-M5 Lt m f e b k kt g h C i-oj Type X Y Z a b c d e f g h i j k m n Mass (kg) ZCED1 ZCED2 ZCED3 ZCED4 ZCED5 260 310 340 380 460 95 110 110 140 150 225 270 295 350 405 100 120 130 155 185 125 150 165 195 220 130 150 150 200 200 65 90 100 130 150 27 27 30 30 30 30 40 40 55 55 135 135 135 200 200 175 175 175 250 250 2 2 2 4 4 14 14 14 18 18 M10 M10 M10 M10 M12 3.2 4.5 4.5 6 6 27 27 27 30 30 15 20 25 30 52 100 ZCED4,5 Mounting hole Dimensions for reference only. Please confirm before construction begins. Split-toroidal type CT/CED 110 NP NP Y K X L 4-M10 d Z X Y Z d a1 a2 b1 b2 c E F n CED1 CED2 CED3 CED3A CED3B CED4 95 110 110 200 250 125 260 310 340 340 340 350 225 285 295 295 295 305 65 90 100 100 100 130 260 300 300 300 300 300 80 90 95 190 240 110 220 260 260 260 260 260 -- -- -- 120 120 70 125 165 165 165 165 165 27 27 27 50 50 50 57 82 67 65 65 50 2 2 2 4 4 4 Dimensions for reference only. Please confirm before construction begins. o 3.2 Secondary terminal M5 F C k l b1 a1 Type E Mounting hole n-o14 b2 a2 Earth voltage transformer VT/GVE1, GVE2 U NP (single-phase) (U) (V) U (U) (V) U (W) U (W) U U U V U uv ab V U uv ab 0 V uv ab 0 a NP (3-phase) b u w a b au bv v a b v c d X f 11 Primary terminal M6 Tertiary terminal M5 e z au bv v c Fuse Secondary terminal M5 u v v b c Primary neutral terminal M6 4-o12 f f+40 Y Type X Y Z a b c d e f Mass (kg) GVE1 GVE2 428 476 265 305 284 300 136 152 146 162 104 128 220 220 90 100 220 220 59 82 Dimensions for reference only. Please confirm before construction begins. Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 11/49 H.V. Distribution Equipment Instrument transformers Dimensions, mm Earthing voltage transformer VT (with fuse links) GPE12-20 GPE9-10 35 35 V o10 Mass: 76kg Mass: 125kg 20 o10 V 20 85 Earth terminal M8 V Name plate u u u u v U 295 U 773 160 u a u a b v b v b 98 a v 160 20 4-o12 220 u 126 M6 M8 6 b 315 95 v 385 b Primary neutral terminal M6 134 566 260 50 v 3 phase name plate 455 140 25 a 153 u 40 b a 143 v u 301 416 a 475 223 3 u U 275 6 95 275 6 135 160 183 226 226 530 452 410 770 300 350 4-o14 Lifting lug GPE13-20 o10 V V U Mass: 190kg U Fuse 500 170 170 290 135 160 W U U U 160 U U U 901 535 320 6 95 V U 35 o10 Mass: 75kg V U 75 Earth terminal M8 20 35 20 GPE8-10 320 225 v b v b Primary neutral terminal M6 a b 3 220 20 u v 4-o12 6 b a b u v a b u v 160 460 V 252 V V M8 148 v 510 a 95 u 25 a 415 u 310 160 195 a 40 u 377 M6 262 261 260 310 6 50 560 4-o14 350 Lifting lug GPE21-30 GPE7-10, GPE7-15 Mass: 140kg 35 2-M8, Depth 15 Mass: 160kg U U U Secondary and tertiary terminal M6 377 Fuse U U 900 360 135 u a b v b 452 680 320 320 20 6 260 310 4-o14 350 Primary neutral terminal M8 v a u a u b v b v V V 560 a b V o14 Secondary and tertiary terminal M6 11/50 350 225 u 163 30 a v 425 u b 50 a v 6 u 280 95 226 U 6 V 467 V 50 20 V 226 Lifting lug o10 310 350 Neutral terminal M8 Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice