203
MEDER electronic
www.meder.com
High Frequency SIL
Reed Relays
RELAY DATA
SIL RF Series
All Data
at 20° C
Switch Model →
Contact Form →
Switch 72
Form A
Contact Ratings Conditions Min. Typ. Max. Units
Switching Power
Any DC combination of V & A
not to exceed their individual
max.‘s 15 W
Switching Voltage DC or peak AC 200 V
Switching Current DC or peak AC 1.0 A
Carry Current DC or peak AC 1.25 A
Static Contact Resistance w/ 0.5 V & 10mA 150 mΩ
Dynamic Contact Resistance Measured w/ 0.5 V & 50mA ,
1.5 ms after closure 200 mΩ
Insulation Resistance across
Contacts
Across Contact
Coil - Contact
1012
1012 1013 Ω
Breakdown Voltage across
Contacts
Across Contact
Coil - Contact
250
1500 VDC
Operate Time incl. Bounce at nominal voltage 0.7 ms
Release Time with no coil suppression 0.1 ms
Capacitance Across Contact
Coil - Contact
0.2
2.0 pF
Life Expectance
Switch Voltage
5V - 10 mA DC <10 pF stray cap. 1000 106
Cycles
For other load requirements, see the life test section on P. 120.
Environmental Data
Shock Resistance 1/2 sinus wave for 11 ms 50 g
Vibration Resistance 10 - 2000 Hz 20 g
Ambient Temperature 10°C/ minute max. allowable -20 70 oC
Stock Temperature 10°C/ minute max. allowable -35 95 oC
Soldering Temperature 5 sec. 260 oC