International Power Sources, Inc. 200 WATT * AUTO-RANGING INPUT SWITCHING POWER SUPPLY DESCRIPTION The PU200 Series is comprised of single and multiple output models for 200 watts of continuous output power. Auto ranging input allows them to operate from any line voltage throughout the world without a selector strap. All auxiliary outputs have magnetic amplifier or linear regulators to maintain tight output tolerances. A cover-and-fan assembly are optional. All models meet VDE Class B and FCC Class B emission limits, and are approved to UL, CSA, and, TUV safety standards. FEATURES * Auto-ranging input * Built-in EMI filter * Short circuit protection with auto-recovery * Power fail detection * 100% burn-in at full rated load * Optional cover-and-fan assembly * Small size 9.0"x 5.0"x 2.55" OUTPUT VOLTAGE/CURRENT RATINGS CHART Output #1 Model PU200-10 PU200-12 PU200-13 PU200-14 PU200-16 PU200-18 PU200-23 PU200-24 PU200-25 PU200-30 PU200-31 PU200-32 PU200-40 PU200-41 PU200-42 PU200-44 PU200-45 NOTE: (1) (2) (3) Vnom Imin Imax 5V 3A 40A 12V 1.2A 16.7A 15V 1.0A 13.4A 24V 0.6A 8.4A 30V 0.5A 6.7A 48V 0.3A 4.2A +5V 3A 30A +5V 3A 30A +5V 3A 30A +5V 3A 30A +5V 3A 30A +5V 3A 30A +5V 3A 30A +5V 3A 30A +5V 3A 30A +5V 3A 30A +5V 3A 30A Tol. 2% 2% 2% 2% 2% 2% 2% 2% 2% 2% 2% 2% 2% 2% 2% 2% 2% Output #2 Output #3 Vnom Imin Imax N/A N/A N/A N/A N/A N/A +12V 0A 8A +15V 0A 6A +24V 0A 4A +12V 0A 8A +12V 0A 8A +15V 0A 6A +12V 0A 8A +15V 0A 6A +12V 0A 8A +12V 0A 8A +12V 0A 8A Ipeak Tol. Vnom Imin Imax N/A N/A N/A N/A N/A N/A 12A 4% N/A 9A 4% N/A 6A 4% N/A 12A 4% -5V 0A 6A 12A 4% -12V 0A 4A 9A 4% -15V 0A 4A 12A 4% -12V 0A 4A 9A 4% -15V 0A 4A 12A 4% -12V 0A 4A 12A 4% -15V 0A 4A 12A 4% -12V 0A 4A Output #42 Tol. Vnom Imin Imax N/A N/A N/A N/A N/A N/A N/A N/A N/A 4% N/A 4% N/A 4% N/A 4% F 5V 0A 6A 4% F 24V 0A 4A 4% F 12V 0A 4A 4% F 15V 0A 4A 4% F 24V 0A 4A Tol. 4% 4% 4% 4% 4% Maximum Output Power3 200W 200W 200W 200W 200W 200W 200W 200W 200W 200W 200W 200W 200W 200W 200W 200W 200W Add suffix "B" for U-bracket or "C" for enclosed i.e. PU200-45C. Output #4 is floating. It can be connected externally for positive or negative output. 200 watts for "C" version with a cover-and-fan assembly. 150 watts for "B" version without moving air (maximum current of output #1 & #2 derated to 70%), or 200 watts with 25 CFM forced air provided by user. 76 GENERAL SPECIFICATIONS INPUT SPECIFICATIONS All specifications are typical at nominal line, full load, and 25C. Efficiency: Hold-up time: Line regulation: Inrush current: Safety ground leakage current: Withstand voltage: Operating temperature: Storage temperature: Mean time between failure: EMI requirements: Safety requirements: Power Fail Detect (PFD SIGNAL) Input voltage: Input frequency: Input current: 70% typical at 200W output 20 msec minimum at 110 VAC input 0.5% maximum at full load 60A maximum at cold start 0.35mA max. @ 110VAC. 60Hz 0.63mA max. @ 240VAC. 50Hz 3000 VAC from input to output 1500 VAC from input to ground 0 to 70C* -40 to +85C 85,000 hours at full load at 25C ambient Meets conduction limits of a) FCC 20780 Level B b) CISPR 22 (EN 55022) Level B Meets or exceeds: a) UL 1950 b) CSA C22.2 No. 234 c) IEC 950 TTL logic high for normal operation and TTL logic low upon loss of input power. This signal appears at least 1mS prior to 5V output dropping 5% below its nominal value. This signal also provides a minimum delay of 100 mS after +5V is within regulation. 90 to 130 VAC, 180 to 264 VAC 47 to 440 Hz 4.5A (rms) for 115 VAC 2.6A (rms) for 230 VAC OUTPUT SPECIFICATIONS Output voltage: Output current: Output power range: Ripple and noise: Overvoltage protection: Overcurrent protection: Temperature coefficient: Transient response: Cooling: See Rating Chart See Rating Chart See Note#3 on front of data sheet 2% peak to peak maximum Provided on output #l only: set at 112-132% of its nominal output voltage All outputs protected to short circuit conditions All outputs 0.04%/C maximum Maximum excursion of 4% or better on all models recovering to 1% of final value within 500us after a 25% step load change 25 CFM forced air provided on "C" version to be provided by user on "B" version. * Derate linearly from 100% load at 50C to 50% load at 70C MECHANICAL SPECIFICATIONS NOTES: 1. Dimensions shown in inches [mm] 2. Tolerance 0.02 [0.5] maximum 3. Input connector P1 is Beau Inc. P/N 72-5-03C, output connector P2 is Beau Inc. P/N 72-5-09C. Screws are #6-32 on 0.375 inch centers. 4. Connector P3 mates with Molex housing 22-01-1043 and Molex 40445 series crimp terminal. 5. Weight: 1.25 Kgs (2.8 Lbs) approx. for "B" version. 1.50 Kgs (3.3 Lbs) approx. for "C" version. P1 1-Line 2-Neutral 3-Ground PIN CHART Model P2 PIN P3 1, 2 3, 4, 5 6 7 8 9 1 2 3 4 PU200-10, PU200-12 PU200-13, PU200-14 PU200-16, PU200-18 -SENSE RET. OUTPUT #1 OUTPUT #1 OUTPUT #1 +SENSE P.F.D. COM. RET. COM. RET. FAN PU200-23, PU200-24 PU200-25 OUTPUT #1 COM. RET. OUTPUT #2 N.C. N.C. N. C. P.F.D. COM. RET. COM. RET. FAN PU200-30, PU200-31 PU200-32 OUTPUT #1 COM. RET. OUTPUT #2 OUTPUT #3 N.C. N.C. P.F.D. COM. RET. COM. RET. PU200-40, PU200-41 PU200-42, PU200-44 PU200-45 OUTPUT #1 COM. RET. OUTPUT #2 OUTPUT #3 OUTPUT #4 RETURN OUTPUT #4 P.F.D. COM. RET. COM. RET. FAN FAN Your Source of Power ... International Power Sources, Inc. 77 260 Hopping Brook Road, Holliston, MA 01746 TEL: (508) 429-4440 FAX: (800) 226-2100 http://www.intlpower.com